    Have a look at the manual Panasonic Protocol Converter Aw If400g Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
    - 10 (E) -
    ENGLISH
    
    Connections
    CONTROL OUT  
    TO PAN/TILT HEAD
    Main unit
    Control panel (max. 1000 m)
    (max. 500 m)
    Multi-function controller AW-RP605A 10BASE-T (UTP category 5) 
    straight cable
    AC adapter
    AW-PS505A Convertible 
    camera
    Camera cable supplied with 
    AW-PH400
    AC power cable supplied with 
    AW-PH400
    Protocol converter
    AW-IF400G
    AC adapter
    AW-PS505A
    Zoom lens
    IP/RP
    Indoor pan/tilt head
    AW-PH400
    When controlling AW-PH400 from AW-RP605A (AW-RP605)
    • Switch settings
    SW1SW2SET UP
    1234
    OFFOFFONOFFON(300 deg)OFF(190 deg)OFF 
    						
    							
    - 11 (E) -
    
    Connections
    (max. 1000 m)(max. 500 m)
    Multi hybrid control panel AW-RP555 10BASE-T (UTP category 5) 
    straight cable
    AC adapter
    AW-PS505A Convertible 
    camera
    Camera cable supplied with 
    AW-PH400
    AC power cable supplied with 
    AW-PH400
    Protocol converter
    AW-IF400G
    AC adapter
    AW-PS505A
    Zoom lens
    IP/RP
    Indoor pan/tilt head
    AW-PH400
    When controlling AW-PH400 from AW-RP555
    • Switch settings
    SW1SW2SET UP
    1234
    OFFOFFONOFFON(300 deg)OFF(190 deg)OFF 
    						
    							
    - 12 (E) -
    ENGLISH
    
    Connections
    (max. 1000 m)(max. 500 m)
    Multi-function controller AW-RP655 10BASE-T (UTP category 5) 
    straight cable
    AC adapter
    AW-PS505A Convertible 
    camera
    Camera cable 
    supplied with 
    AW-PH400
    AC power cable 
    supplied with 
    AW-PH400
    Protocol converter
    AW-IF400G
    AC adapter
    AW-PS505A
    Zoom lens
    IP/RP
    Indoor pan/tilt head AW-PH400
    When controlling AW-PH400 from AW-RP655
    • Switch settings
    SW1SW2SET UP
    1234
    OFFOFFONOFFON(300 deg)OFF(190 deg)OFF 
    						
    							
    - 13 (E) -
    
    Connections
    When controlling AW-PH350 from AW-RP400
    CONTROL IN IP/RP
    Indoor pan/tilt headAW-PH350
    Pan/tilt control panel AW-RP400 CONTROL OUT 
     
    TO PAN/TILT 
    HEAD 10BASE-T (UTP category 5) 
    straight cable
    Protocol converter
    AW-IF400G
    Remote operation panel
    AW-CB400
    AC adapter
    AW-PS505A
    Convertible 
    camera
    Camera cable 
    AW-CA50T29
    AW-CA50C29
    AC adapter
    AW-PS300A
    Zoom lens
    AC adapter
    AW-PS505A
    (max. 500 m)
    (max. 1000 m)
    • Switch settings
    SW1SW2SET UP
    1234
    OFFONOFFONOFFOFF 
    						
    							
    - 14 (E) -
    ENGLISH
    
    Connections
    When controlling AW-PH360 from AW-RP400
    (The tracing memory function is not available.)
      Set the SW1 switch on the CPU circuit board of AW-PH360 to “For RP605”. 
    (For details, refer to the operating instructions for the AW-PH360.)
    CONTROL IN IP/RP
    Indoor pan/tilt head AW-PH360
    Pan/tilt control panel AW-RP400 CONTROL OUT 
     
    TO PAN/TILT 
    HEAD 10BASE-T (UTP category 5) 
    straight cable
    Protocol converter
    AW-IF400G
    Remote operation panel
    AW-CB400
    AC adapter
    AW-PS505A
    Convertible 
    camera
    Camera cable 
    supplied with 
    AW-PH360
    AC adapter
    AW-PS300A
    Zoom lens
    AC adapter
    AW-PS505A
    (max. 500 m)
    (max. 1000 m)
    • Switch settings
    SW1SW2SET UP
    1234
    OFFONOFFONOFFOFF 
    						
    							
    - 15 (E) -
    
    Connections
    When controlling AW-PH650 from AW-RP400
    ( For the connections of the AW-PH650 pan/tilt head, camera housing, and camera, refer to the operating instructions for the AW-PH650.)
    Pan/tilt control panel AW-RP400 CONTROL OUT 
     
    TO PAN/TILT 
    HEAD 10BASE-T (UTP category 5) 
    straight cable
    Protocol converter
    AW-IF400G
    Remote operation panel
    AW-CB400
    AC adapter
    AW-PS505A
    AC adapter
    AW-PS505A
    (max. 500 m)
    (max. 1000 m)• Switch settings
    SW1SW2SET UP
    1234
    OFFONOFFONOFFOFF
    Outdoor  pan/tilt head
    AW-PH650
    To be locally 
    purchased
    RJ-45 relay adapter
    REMOTE
    POWER 
    						
    							
    - 16 (E) -
    ENGLISH
    
    Connections
    Pan/tilt control panelAW-RP400Remote operation panel
    AW-CB400
    CONTROL OUT 
     
    TO PAN/TILT 
    HEAD 10BASE-T (UTP category 5) 
    straight cable
    Protocol converter
    AW-IF400G
    IP/RP
    Indoor pan/tilt head
    AW-PH400
     When using the extended distance transmission function  
    of AW-RP400 and AW-PH400
    AC adapter
    AW-PS505A
    Convertible 
    camera
    Camera cable supplied with 
    AW-PH400
    AC power cable supplied with 
    AW-PH400
    Zoom lens
    AC adapter
    AW-PS505A
    (max. 500 m)
    (max. 500 m)
    • Switch settings
    SW1SW2SET UP
    1234
    ONONOFFOFFOFFOFF 
    						
    							
    - 17 (E) -
    
    Indoor pan/tilt headAW-PH360
    Pan/tilt control panel AW-RP400 CONTROL OUT 
     
    TO PAN/TILT 
    HEAD 10BASE-T (UTP category 5) 
    straight cable
    Protocol converter
    AW-IF400G
    Remote operation panel
    AW-CB400
    AC adapter
    AW-PS505A
    Convertible 
    camera
    Camera cable 
    supplied with 
    AW-PH360
    AC adapter
    AW-PS300A
    Zoom lens
    AC adapter
    AW-PS505A
    (max. 500 m)
    (max. 500 m)
    Connections
     When using the extended distance transmission function of AW-RP400 and AW-PH360
    (The tracing memory function is available.)
    • Switch settings
    SW1SW2SET UP
    1234
    ONONOFFOFFOFFOFF 
    						
    							
    - 18 (E) -
    ENGLISH
    
    1/4(6)
    1-15/16(50)
    9/16(15)
    5-11/16(145)
    3-3/8(85)
    1-3/16(30)
    Appearance
       For mounting and other applications, use the screw  
    (M3 screw) holes in the side panels.
     
    Do not use screws longer than 10 mm.
    Unit: inch (mm)
    M3 screw hole (in 4 locations)
    ( Located in the 
    same positions on both sides) 
    						
    							
    - 19 (E) -
    
    Specifications
    Controller supported: AW-RP400, AW-RP555, AW-RP605, AW-RP605A, AW-RP655
    Pan/tilt head supported:  AW-PH350, AW-PH360, AW-PH400, AW-PH650
    Input connectors
     
      DC 12 V IN socket:   Supply DC 12 V from the general-purpose AC adapter.
     
    (Recommended AC adapter: AW-PS505A)
    Input/Output connector
      CONTROLLER:   RJ45, modular jack
     
    10BASE-T straight cable (UTP category 5)
      PAN-TILT HEAD:   RJ45, modular jack
     
    10BASE-T straight cable (UTP category 5)
    Switch functions:  Controller / Pan/Tilt Head selector switch (SW1, SW2, SET UP)
    Indicator:  POWER, COMMUNICATE, EXTENSION
    Allowable operating temperature:
     
       
    14°F to 113°F (–10°C to +45°C)
    Ambient operating humidity: 
    30% to 90% (no condensation)
    Dimensions (WHD): 5-11/16”1-3/16”3-3/8” (1453085 mm)  (excluding rubber feet)
    Weight:  Approx. 0.9 lbs. (0.4 kg)
    Finish:  AV ivory paint (color resembling Munsell 7.9Y 6.8/0.8)
    Weight and dimensions indicated are approximate.
    Specifications are subject to change without notice. Source voltage:  DC 10.8 V to DC 16.0 V
    Power consumption:  1.5 W
     indicates safety information. 
    						
    All Panasonic manuals Comments (0)