    							Chapter 4 Settings — [NETWORK] menu
    ENGLISH - 131
    [Network config] page
    Click [Detailed set up] → [Network config].
     fClick [Network config] to display the  [CAUTION!]
    
     screen.
     fThe current settings are displayed by pressing the [Next] button.
     fClick [Change] to display the setting change screen.
    1
    2
    3
    4
    5
    6
    7
    8
    1 [PROJECT OR NAME]
    Enter the name of the projector. Enter the host name if it is 
    required when using a DHCP server etc.
    2
     
    [DHCP
      ON], [DHCP OFF]
    To enable the DHCP client function, set to [DHCP ON].
    3
     
    [IP
      ADDRESS]
    Enter the IP address when not using a DHCP server.
    4
     
    [SUBNET MASK]
    Enter the subnet mask when not using a DHCP
    
     server.
    5
     
    [DEF
     AULT GATEWAY]
    Enter the default gateway address when not using a DHCP 
    server. 6
     [DNS1]
    Enter the DNS1 server address.
    Permissible characters for the entry of DNS1 server address 
    (primary):
    Numbers (0 - 9), period (.)
    (Example: 192.168.0.253)
    7
     
    [DNS2]
    Enter the DNS2 server address.
    A
    
    vailable characters for the entry of DNS2 server address 
    (secondary):
    Numbers (0 - 9), period (.)
    (Example: 192.168.0.254)
    8
     
    [Back], [Next]
    Click the [Back] button to return to the original screen. 
    
    The 
    current settings are displayed by pressing the [Next] button. 
    Click the [Submit] button to update the settings.
    Note
     f When you use the “Forward” and “Back” functions of your browser , a warning message “Page has Expired” may appear. In that case, click 
    [Network config] again since the following operation will not be guaranteed.
     f Changing LAN settings while connected to the LAN may cause the connection to cut out.   
    						
    							Chapter 4 Settings — [NETWORK] menu
    132 - ENGLISH
    [Adjust clock] page
    Click [Detailed set up] → [Adjust clock].
    1
    2
    3
    4
    5
    6
    7
    1 [Time Zone]
    Select the time zone.
    2
     
    [Set time zone]
    Updates the time zone setting.
    3
    
     
    [NTP
      SYNCHRONIZATION]
    Set to [ON] to adjust the date and time automatically.
    4
     
    [NTP
      SERVER NAME]
    Enter the IP address or server name of the NTP server when 
    you set to adjust the date and time manually.
    (To enter the server name, the DNS server needs to be set up.) 5
     [Date]
    Enter the date to be changed.
    6
     
    [T
     ime]
    Enter the time to be changed.
    7
     
    [Set date and time]
    Updates the date and time settings.
    Note
     fThe replacement of the battery inside the projector is required when the time goes out of alignment right after correcting the time. Consult 
    your dealer
    .
    [Ping test] page
    Check whether the network is connected to the E-mail server, POP server, DNS server, etc.
    Click [Detailed set up]  → [Ping test].
    1
    2
    3
    4
    1 [Input IP  address]
    Enter the IP address of the server to be tested.
    2
     
    [Submit]
    Executes the connection test. 3
    
     Example of display when the connection has succeeded
    4  
    Example of display when the connection has failed   
    						
    							Chapter 4 Settings — [NETWORK] menu
    ENGLISH - 133
    [E-mail set up] page
    When there is a problem or the runtime of a lamp reaches a set value, an E-mail can be sent to preset E-mail addresses (up to two 
    addresses).
    Click [Detailed set up] → [E-mail set up].
    1
    2
    3
    4
    5
    6
    1 [ENABLE]
    Select [Enable] to use the E-mail function.
    2
     
    [SMTP
      SERVER NAME]
    Enter the IP address or the server name of the E-mail server 
    (SMTP). To enter the server name, the DNS server needs to be 
    set up.
    3
     
    [MAIL
      FROM]
    Enter the E-mail address of the projector. (Up to 63 characters 
    in single byte)
    4
     
    [MEMO]
    Enter information such as the location of the projector that 
    notifies the sender of the E-mail. (Up to 63 characters in single 
    byte) 5
    
     [MINIMUM TIME]
    Change the minimum interval for the temperature warning 
    E-mail. 
    The default value is 60 minutes. In this case, another 
    E-mail will not be sent for 60 minutes after sending the 
    temperature warning E-mail even if it reaches the warning 
    temperature.
    6
     
    [INT
     AKE AIR TEMPERATURE]
    Change the temperature setting for the temperature warning 
    mail. A temperature warning E-mail is sent when the 
    temperature exceeds this value.   
    						
    							Chapter 4 Settings — [NETWORK] menu
    134 - ENGLISH
    8
    7
    9
    8
    7
    7 [E‑ MAIL ADDRESS 1], [E ‑ MAIL ADDRESS 2]
    Enter the E-mail address to be sent. Leave [E-MAIL ADDRESS 
    2] blank when two E-mail addresses are not to be used. 8
     Settings of the conditions to send E-mail
    Select the conditions to send E-mail.
    [MAIL
     CONTENTS]: 
    Select either [NORMAL] or [SIMPLE].
    [ERROR]: 
    Send an E-mail when an error occurred in the self-diagnosis.
    [LAMP1 RUNTIME]:
    Send an E-mail when the remaining lamp runtime for the lamp 1 
    has reached the value set at the right field.
    [LAMP2 RUNTIME]:
    Send an E-mail when the remaining lamp runtime for the lamp 2 
    has reached the value set at the right field.
    [LAMP3 RUNTIME]: 
    Send an E-mail when the remaining lamp runtime for the lamp 3 
    has reached the value set at the right field.
    [LAMP4 RUNTIME]: 
    Send an E-mail when the remaining lamp runtime for the lamp 4 
    has reached the value set at the right field.
    [INTAKE AIR TEMPERATURE]: 
    Send an E-mail when the air intake temperature has reached 
    the value set at the above field.
    [PERIODIC REPORT]: 
    Place a check mark on this to send an E-mail periodically.
    It will be sent on the days and time with the check mark.
    9
     
    [Submit]
    Update the settings.   
    						
    							Chapter 4 Settings — [NETWORK] menu
    ENGLISH - 135
    [Authentication set up] page
    Set the authentication items when POP authentication or SMTP authentication is necessary to send an E-mail.
    Click [Detailed set up] → [Authentication set up].
    1
    2
    3
    4
    5
    6
    7
    8
    1 [Auth]
    Select the authentication method specified by your Internet 
    service provider
    .
    2
     
    [SMTP
      Auth]
    Set when the SMTP authentication is selected.
    3
     
    [POP
      server name]
    Enter the POP server name.
    Allowed characters:
    Alphanumerics (A - Z, a - z, 0 - 9)
    Minus sign (-) and period (.)
    4
     
    [User name]
    Enter the user name for the POP
    
     server or the SMTP server. 5
     [Password]
    Enter the password for the POP
     server or the SMTP server.
    6
     
    [SMTP
      server port]
    Enter the port number of the SMTP server.
    (Normally 25)
    7
     
    [POP
      server port]
    Enter the port number of the POP server.
    (Normally 110)
    8
     
    [Submit]
    Update the settings.   
    						
    							Chapter 4 Settings — [NETWORK] menu
    136 - ENGLISH
    Contents of E-mail sent
    Example of the E-mail sent when E-mail is set
    The following E-mail is sent when the E-mail settings have been established.
    === P anas onic  pr ojec t or  r epor t ( CO NF I G URE )  ===
    P r ojec t or  T y pe  :  DZ 16K
    S er ial No  :  S W1234567
    -----  E-mail set up dat a -----
    T EMPERAT URE WARNING  SET UP 
    M I NI M UM  T I M E   at  [  60]  m inut es  int er v al 
    I NT A K E  A I R T E M P E RA T URE   O v er  [  46degC /  114degF  ]  
    E RRO R  [  O F F  ]  
    LAMP1 RUNTIME  [ OFF ]   at REMAIN [ 400] H 
    LAMP1 RUNTIME  [ OFF ]   at REMAIN [ 200] H 
    LAMP2 RUNTIME  [ OFF ]   at REMAIN [ 400] H 
    LAMP2 RUNTIME  [ OFF ]   at REMAIN [ 200] H 
    LAMP3 RUNTIME  [ OFF ]   at REMAIN [ 400] H 
    LAMP3 RUNTIME  [ OFF ]   at REMAIN [ 200] H 
    LAMP4 RUNTIME  [ OFF ]   at REMAIN [ 400] H 
    LAMP4 RUNTIME  [ OFF ]   at REMAIN [ 200] H 
    INT AKE AIR T EMPERAT URE  [ O F F  ] 
    P E RI O DI C RE P O RT  
    S unday   [  O F F  ]   M onday   [  O F F  ]   T ues day   [  O F F  ]   Wednes day   [  O F F  ]  
    T hur s day   [  O N  ]   F r iday   [  O F F  ]   S at ur day   [  O F F  ]  
    00: 00  [  O F F  ]     01: 00  [  O F F  ]     02: 00  [  O F F  ]     03: 00  [  O F F  ]  
    04: 00  [  O F F  ]     05: 00  [  O F F  ]     06: 00  [  O F F  ]     07: 00  [  O F F  ]  
    08: 00  [  O F F  ]     09: 00  [  O F F  ]     10: 00  [  O F F  ]     11: 00  [  O F F  ]  
    12: 00  [  O F F  ]     13: 00  [  O F F  ]     14: 00  [  O F F  ]     15: 00  [  O F F  ]  
    16: 00  [  O F F  ]     17: 00  [  O F F  ]     18: 00  [  O F F  ]     19: 00  [  O F F  ]  
    20: 00  [  O F F  ]     21: 00  [  O F F  ]     22: 00  [  O F F  ]     23: 00  [  O F F  ]  
    -----  check syst em -----
    M A I N CP U B US  [   O K   ]
    F A N  [   O K   ]
    INT AKE AIR T EMPERAT URE  [   O K   ]
    O PT ICS MO DULE T EMPERAT URE  [   O K   ]
    ARO UND LAMP T EMPERAT URE  [   O K   ]
    LAMP1 REMAIN T IME  [   O K   ]
    LAMP2 REMAIN T IME  [   O K   ]
    LAMP3 REMAIN T IME  [   O K   ]
    LAMP4 REMAIN T IME  [   O K   ]
    LAMP1 ST AT US  [   O K   ]
    LAMP2 ST AT US  [   O K   ]
    LAMP3 ST AT US  [   O K   ]
    LAMP4 ST AT US  [   O K   ]
    A P E RT URE (CO NT RA S T -S HUT T E R)  [    O K    ]
    S HUT T E R(M UT E -S HUT T E R)  [   O K   ]
    INT AKE AIR T EMP.SENSO R  [   O K   ]
    O PT ICS MO DULE T EMP.SENSO R  [   O K   ]
    ARO UND LAMP T EMP.SENSO R  [   O K   ]
    BAT T ERY  [   O K   ]
    LE NS  M O UNT E R  [   O K   ]
    BRIG HT NESS SENSO R  [   O K   ]
    ANG LE SENSO R  [   O K   ]
    F I LT E R UNI T   [   O K   ]
    A I R F I LT E R  [   O K   ]
    AC PO WER  [   O K   ]
    ( E r r or  c ode 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00)
    I nt ak e air  t em per at ur e  :  27 degC /   80 degF
    O pt ic s  m odule t em per at ur e :  33 degC /   91 degF
    A r ound lam p t em per at ur e  :  32 degC /   89 degF
    P RO JE CT O R RUNT I M E   0 H
    P O WE R O N  0 t im es
    LA M P 1 O N  0 t im es
    LA M P 1  0 H
    LA M P 1 RE M A I N  3000 H
    LA M P 2 O N  0 t im es
    LA M P 2  0 H 
    LA M P 2 RE M A I N  3000 H
    LA M P 3 O N  0 t im es
    LA M P 3  0 H 
    LA M P 3 RE M A I N  3000 H
    LA M P 4 O N  0 t im es
    LA M P 4  0 H 
    LA M P 4 RE M A I N  3000 H
    -------- Current  st at us ---------
    MAIN VERSIO N  1.00 
    NET WO RK VERSIO N  1.00 
    SUB VERSIO N  1. 00 
    LAMP ST AT US  LA M P 1=O F F  LA M P 2=O F F  LA M P 3=O F F  LA M P 4=O F F  
    I NP UT   RG B 1
    REMO T E2 ST AT US  DISABLE 
    ----- Wired Net work conf igurat ion -----
    DHCP  Client   O F F  
    I P  addr es s   192. 168. 0. 8
    M A C addr es s   00: 40: 63: 00: 01: 24
    T ue J an 07 17: 20: 39 2014
    ----- Memo -----   
    						
    							Chapter 4 Settings — [NETWORK] menu
    ENGLISH - 137
    Example of the E-mail sent for an error
    The following E-mail is sent when an error has occurred.
    === P anas onic  pr ojec t or  r epor t(E RRO R) ===
    P r ojec t or  T y pe  :  DZ 16K
    S er ial No  :  S W1234567
    -----  check syst em -----
    M A I N CP U B US   [   O K   ]
    F A N  [   O K   ]
    INT AKE AIR T EMPERAT URE  [   O K   ]
    O PT ICS MO DULE T EMPERAT URE  [   O K   ]
    ARO UND LAMP T EMPERAT URE  [   O K   ]
    LAMP1 REMAIN T IME  [ F AILED ]
    LAMP2 REMAIN T IME  [   O K   ]
    LAMP3 REMAIN T IME  [   O K   ]
    LAMP4 REMAIN T IME  [   O K   ]
    LAMP1 ST AT US  [   O K   ]
    LAMP2 ST AT US  [   O K   ]
    LAMP3 ST AT US  [   O K   ]
    LAMP4 ST AT US  [   O K   ]
    A P E RT URE (CO NT RA S T -S HUT T E R)  [    O K    ]
    S HUT T E R(M UT E -S HUT T E R)  [    O K    ]
    INT AKE AIR T EMP.SENSO R  [   O K   ]
    O PT ICS MO DULE T EMP.SENSO R  [   O K   ]
    ARO UND LAMP T EMP.SENSO R  [   O K   ]
    BAT T ERY  [   O K   ]
    LE NS  M O UNT E R  [   O K   ]
    BRIG HT NESS SENSO R  [   O K   ]
    ANG LE SENSO R  [   O K   ]
    F I LT E R UNI T   [   O K   ]
    A I R F I LT E R  [   O K   ]
    AC PO WER  [   O K   ]
    ( E r r or  c ode 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00)
    I nt ak e air  t em per at ur e  :  27 degC /   80 degF
    O pt ic s  m odule t em per at ur e :  33 degC /   91 degF
    A r ound lam p t em per at ur e  :  32 degC /   89 degF
    P RO JE CT O R RUNT I M E   0 H
    P O WE R O N  100 t im es
    LA M P 1 O N  100 t im es
    LA M P 1  3000 H
    LAMP1 REMAIN  0 H
    LA M P 2 O N  0 t im es
    LA M P 2  0 H 
    LA M P 2 RE M A I N  3000 H
    LA M P 3 O N  0 t im es
    LA M P 3  0 H 
    LA M P 3 RE M A I N  3000 H
    LA M P 4 O N  0 t im es
    LA M P 4  0 H 
    LA M P 4 RE M A I N  3000 H
    -------- Current  st at us ---------
    MAIN VERSIO N  1.00 
    NET WO RK VERSIO N  1.00 
    SUB VERSIO N  1.00 
    LAMP ST AT US  LAMP1=O F F  LAMP2=O F F  LAMP3=O F F  LAMP4=O F F  
    I NP UT   RG B 1
    REMO T E2 ST AT US  DISABLE 
    ----- Wired Net work conf igurat ion -----
    DHCP  Client   O F F  
    I P  addr es s   192. 168. 0. 8
    M A C addr es s   00: 40: 63: 00: 01: 24
    T ue J an 07 17: 22: 32 2014
    ----- Memo -----   
    						
    							Chapter 4 Settings — [NETWORK] menu
    138 - ENGLISH
    [Change password] page
    Click [Change password].
    1
    2
    3
    1 [Administrator]
    Used to change the setting of the [Administrator].
    2
     
    [User]
    Used to change the setting of the [User]. 3
    
     [Next]
    Used to change the setting of the password.
    [Administrator] account
    1
    3
    2
    4
    1 [Account]
    Displays the account to change.
    2
     
    [Current]
    [User name]: 
    Enter the user name before the change.
    [Password]: 
    Enter the current password. 3
    
     [New]
    [User name]: 
    Enter the desired new user name. (Up to 16 characters in single 
    byte)
    [Password]: 
    Enter the desired new password. (Up to 16 characters in single 
    byte)
    [Password(Retype)]: 
    Enter the desired new password again.
    4
     
    [OK]
    Determines the change of password.   
    						
    							Chapter 4 Settings — [NETWORK] menu
    ENGLISH - 139
    [User] account
    1
    2
    3
    1 [Account]
    Displays the account to change.
    2
     
    [New]
    [User name]: 
    Enter the desired new user name. (Up to 16 characters in single 
    byte)
    [Password]: 
    Enter the desired new password. (Up to 16 characters in single 
    byte)
    [Password(Retype)]: 
    Enter the desired new password again. 3
    
     [OK]
    Determines the change of password.
    [Change password] (For user rights)
    Only the change of password is enabled under the user rights.
    1
    2
    4 3
    1 [Old Password]
    Enter the current password.
    2
     
    [New Password]
    Enter the desired new password. (Up to 16 characters in single 
    byte) 3
    
     [Retype]
    Enter the desired new password again.
    4
     
    [OK]
    Determines the change of password.
    Note