Information ENGLISH – 111 Procedure of lamp unit replacement 1. Be sure to observe the procedure “Powering up the projector” (p. 35) and “Powering off the projector” (p. 36), remove the power plug and confirm that the surroundings of the lamp unit have cooled off. 2. Use a Phillips screwdriver to loosen the lamp unit cover screw at the rear of the projector until the screw turns freely. 3. Open the lamp unit cover and remove it from the projector. 4. Use a Phillips screwdriver to loosen the...
Page 112
112 – ENGLISH When installing the ceiling mount bracket to the projector, install the accessory eye bolts and wires to the projector. (The projector will still be safe if they are not used, however they will help prevent the possibility of accidents caused by the projector falling down if the screws happen to become loose.) Installation should be carried out by a qualified technician by following the procedure given below. Panasonic takes no responsibility for any losses or damage occurring as a result...
Page 113
Information ENGLISH – 113 Before asking for service … try to check the following points again. Symptoms Check point Page Power does not turn on Is the power cord securely plugged in the receptacle? •34 Is the MAIN POWER switch put to the “O” position? •35, 36 Is power supply live at the receptacle? •34 Is the temperature monitor (TEMP) lamp on the projector front lighting or blinking? •107 Is the lamp monitor (LAMP) lamp on the projector front lighting or blinking? •107 Is the lamp unit cover...
Page 114
114 – ENGLISH There is a self-diagnosis display located at the side of the projector (p. 15) which automatically displays error details when an error occurs. Self-diagnosis display Self- diagnosis displayDetails Remedy U04 Air filter is blocked Clean the air filter unit.• U11 Intake air temperature warning Ambient air temperature is too high. • U12 Optical module temperature warning U13 Lamp ambient temperature warning U14 Low temperature warning U21 Intake air temperature error U22 Optical module...
Page 115
Information ENGLISH – 115 Self- diagnosis displayDetails Remedy F41 Lamp 1 memory error Problem with lamp. Consult your dealer. • F42 Lamp 2 memory error F43 Lamp 3 memory error F44 Lamp 4 memory error F91 FPGA1 configuration error If turning the main power off and back on again does not clear the error display, consult your dealer. • F92 FPGA2 configuration error F93 Flash ROM error F94 RAM error F95 FPGA expansion error F96 Lens shift error FE1 Power supply fan error FE2 Lamp 1 fan error FE3 Lamp 2...
Page 116
116 – ENGLISH Specifications Model No. PT-D10000E PT-DW10000E Power supply220 V – 240 V, 50 Hz/60 Hz Power consumption1 450 W (about 25 W in standby) Amps8 A DLP ® panelPanel size0.95 inch (aspect ratio 4:3) 0.95 inch (aspect ratio 16:9) Display systemThree-unit DLP® chip, DLP® type Number of pixels3 × 1 470 000 pixels (1 400 × 1 050 dots) 3 × 2 073 600 pixels (1 920 × 1 080 dots) Lens (Powered zoom/ Powered focus control)Option Projection lamp4 bulbs × 250 W UHM lamp Optical output *110 000 lm...
Page 117
Information ENGLISH – 117 Model No. PT-D10000E PT-DW10000E Interface portsRGB2 input terminal1 set of high-density, D-sub 15p (female) [For YP BPR input] Y: 1.0 V [p-p] synchronization signal included, PBPR: 0.7 V [p-p] 75 Ω [For RGB input] 0.7 V [p-p] 75 Ω For G-SYNC: 1.0 V [p-p] 75 Ω HD/SYNC: TTL, high-impedance, positive/negative polarity automatically adjusted VD: TTL, high-impedance, positive/negative polarity automatically adjusted HD/SYNC, and VD terminals are not compliant with 3-value...
Page 118
118 – ENGLISH Compatible RGB/YPBPR/DVI-D Signals The following table specifies the types of RGB/ YPBPR/DVI-D signals compatible with the projector. RGB signals can also be input within the range of fH=15 kHz–100 kHz, fV=24 Hz–120 Hz, dot clock=20 MHz–162 MHz. Note The number of display dots of the PT-D10000E is 1 400 × 1 050. If signals with a number of display dots differing from the data listed above are supplied, they will be converted into signals with 1 400 × 1 050 dots and displayed. The number...
Page 119
Information ENGLISH – 119 List of P IN P ○: P IN P (Picture in Picture) combinations are enabled ×: P IN P (Picture in Picture) combinations are disabled *1 480i, 576i, 720/60p, 720/50p, 1 035/60i, 1 080/60i, 1 080/50i, 1 080/24sF, 1 080/30p, 1 080/25p, 1 080/24p *2 480p, 576p, 720/60p, 720/50p, 1 080/60i, 1 080/50i, 1 080/24sF, 1 080/30p, 1 080/25p, 1 080/24p, 1 080/60p, 1 080/50p Note Noise reduction cannot be used with analogue RGB input, DVI input (EDID1 setting) or AUX input (EDID1 setting)....
Page 120
120 – ENGLISH Dimensions Outside dimensions Installation dimensions diagram Attention Leave a clearance of at least 50 cm so that the ventilation opening on the rear panel will not be blocked. Set up the projector so that air can flow freely around the rear of the projector without staying still. In addition, leave a space of 30 cm or more at the sides so that the hot air coming out from the air outlet vents does not get drawn in through the air intake vents. Set up the projector with a space of 40...