Home > Panasonic > Security Camera > Panasonic Network Camera Wv Sw558 Wv Sw559 Installation Guide

Panasonic Network Camera Wv Sw558 Wv Sw559 Installation Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Network Camera Wv Sw558 Wv Sw559 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							31
     w  Engage the camera attachment fixing screws of 
    the camera with the screw hole of the camera 
    attachment (accessory) and rotate the camera 
    in the direction of the arrow to secure the cam-
    era to the camera attachment (accessory).
        Rotate the camera until a click is heard so that 
    the projection of the camera attachment (acces-
    sory) will be set to the LOCK position.
     e  Connect the cables on the side of the mount 
    bracket. (
    ☞ Page 24)
       Waterproof the connecting portion. (
    ☞ Page 
    27)
    IMPORTANT:
      • Disconnect the 12 V power source and PoE 
    power source to prevent power from being sup-
    plied during mounting work. 
     r  Accommodate the connected cables inside the 
    cable guide of the camera mount bracket.
    IMPORTANT: 
      •  To prevent the cables from being caught when 
    the base cover (accessory) is attached, keep 
    the cables inside the cable guide.
       
    LOCKOPEN
    LOCKOPEN
    Projection
    Make cable connection and 
    waterproof the connected section.
    Cable
    guideCable 
    guide Connected 
    cable 
    						
    							32
     t Attach the base cover (accessory) that was 
    removed according the steps in page 19.
     y  Use the bit for tamperproof screw (accessory) 
    to tighten the fixing screws provided on both 
    sides of the base cover (accessory). 
    (Recommended tightening torque: 
    0.78 N·m {0.58 lbf·ft})
    x  Detach the enclosure from the main 
    body by loosening the three fixing 
    screws. 
        Loosen the three fixing screws by using the bit 
    for tamperproof screw (accessory). 
      
    IMPORTANT: 
      •  Do not hold the inner dome when carrying the 
    camera. Otherwise, the camera part may fall 
    and it may damage the camera. 
      •  Because the inner dome is non-detachable, do 
    not detach it when installing this product.
      •  Remove the cover film from the transparent part 
    of the dome cover after the installation is com-
    plete. Do not touch the dome cover by hand 
    directly after removing the cover film. 
    %DVHFRYHU„[LQJVFUHZ
    Base cover
    (accessory) 
    						
    							33
    &DPHUD
    						
    							34
    z  Adjust the camera angle.
    When determining the camera angle, repeat fine adjustments by gradually moving the panning 
    table, tilting table, and azimuth adjustment ring. 
    Horizontal position (Panning)
    Loosen the panning lock screw, rotate the panning table to adjust the pan direction. (Adjustable 
    range: 340 °)
    Panning is possible within the range of 180 ° (when panning clockwise) and 160 ° (when panning 
    counterclockwise). 
    After adjustment, tighten the panning lock screw to fix the panning table. 
    (Recommended tightening torque: 0.59 N·m {0.44 lbf·ft})
    Vertical position (Tilting)
    Loosen the tilting lock screws (x2), and rotate the tilting 
    table to adjust the tilting direction. (Adjustable range: 
    ±75 °) Since a variable focal lens is used, it is possible to 
    change the angular field of view. This lens can also be 
    rotated in the reverse direction, but the image azimuth is 
    reversed. In this case, the image azimuth can be modified 
    when the panning table is rotated to the direction of clock-
    wise panning (180 °). 
    Adjustment
    Tilting lock screw (x2)
    +75 °
    –75 °
    Adjustable range Home position
    Panning lock screw
    Panning table
    180 ° 
    (clockwise) 160 ° 
    (counterclockwise)  
    						
    							35
        
    Horizontal: 24.20° (TELE) to 86.60° (WIDE)
        After adjustment, tighten the tilting lock screws (x2) to fix the tilting table. 
        (Recommended tightening torque: 0.59 N·m {0.44 lbf·ft})
    Note:
      •  When the tilting table is turned to the edge of the adjustable range (±75°), it must be noted that 
    the shadow of the enclosure may be projected.
      •  When the camera is installed to a wall, the image is reversed in the default settings. To correct 
    the way the image is displayed, rotate the panning table 180° clockwise, or select On for 
    Upside-down from the setup menu. For information about performing the Upside-down set-
    ting from the setup menu, refer to the Operating Instructions (included in the CD-ROM).
    Image tilt adjustment
    Rotate the azimuth adjustment ring to adjust the azimuth angle of the image. (Adjustable range: 
    ±100 °) 
    Adjustable range
    –100 °
    +100 °
    Azimuth adjustment ring
        
    						
    							36
    x  Adjust the angular field of view and the focus. 
        Adjust the angular field of view in accordance with the distance between the camera lens and a 
    photographic subject. These adjustments shall be performed together with the camera angle 
    adjustment.
     q  Loosen the zoom lock knob and move the knob between TELE and WIDE to obtain the appro-
    priate angle of view. 
     w  Press the auto focus (AF) button twice quickly to perform basic adjustments. The lamp blinks 
    during auto focus (AF) adjusting. When the adjustment is completed, adjust the viewing angle 
    while watching the screen.
    Note:
      •  The focus may not be adjusted appropriately when the zoom lock knob is positioned at the 
    W (or T) end. In this case, adjust the focus again by slightly turning the zoom lock knob to 
    the direction of T (or W).
      •  With basic adjustments, the focus can be adjusted quickly. For more accurate adjustments use 
    the detailed adjustments.
     e  To adjust the angular field of view with a higher zooming effect even after turning the zoom lock 
    knob almost fully in the T direction, hold down the auto focus (AF) button/extra optical zoom 
    button for 5 seconds or more. 2x extra optical zoom will be applied. When the image capture 
    size under VGA is applied, the zoom factor can be adjusted up to 2x without deterioration of 
    image quality. When holding down the auto focus (AF) button/extra optical zoom button again 
    for 5 seconds or more, 1x extra optical zoom will be applied. 
     r  Tighten the zoom lock knob. 
     t  After fixing the viewing angle, press the auto focus (AF) button once. The auto focus lamp lights 
    for about 10 seconds, and a detailed adjustment for the focus is automatically performed. 
    Loosen Tighten
    Auto focus (AF) button/
    Extra optical zoom button
    Zoom lock knob
    Focus ring
    * Do not move the focus ring. 
    						
    							37
    IMPORTANT: 
      •  Do not move the focus ring.
      •  Defocus may be caused by the reinstalled enclosure. In this case, perform the auto focus func-
    tion from the setup menu. 
      •  After performing basic adjustments, make sure to press the auto focus (AF) button once to per-
    form detailed adjustments.
    Note:
      •  If the zoom lock knob is fully turned in the W direction, the periphery may become dark. In 
    such a case, turn the zoom lock knob in the T direction for readjustment.
      •  If the zoom lock knob is slightly tightened before the zoom is adjusted, the knob will become 
    stable, making fine adjustments easier to perform.
      • When shooting in the following place or the following subjects, focus may not be adjusted 
    automatically. In this case, adjust the focus manually from the setup menu. Refer to the 
    Operating Instructions (included in the CD-ROM) for how to perform the manual focus adjust-
    ment from the setup menu. 
      •  Subj. moving frequently
      •  Subj. with large illuminance change
      •  Subj. with low illuminance
      •  Subj. with reflection or extra brightness
      •  Subj. through a window
      •  Place where the dome cover easily becomes dirty
      •  Subj. with less contrast such as white wall
      •  Subj. with heavy flicker
      • If the 2x extra optical zoom is applied when 2048×1536, 1920×1080, 1280x960, 
    1280x720 is selected for the image capture size, the image quality will be deteriorated 
    because the effect of Extra Optical Zoom is not provided. 
      •  When images in the near-infrared light area change from color to black & white, out-of-focus 
    may be occurred according to the nature of optical property. In this case, the focus can auto-
    matically be corrected by selecting Auto or Preset for Adjusting method on the setup 
    menu (The focus will not automatically be adjusted according to the illumination level change 
    once the focus is corrected.) Refer to the Operating Instructions (included in the CD-ROM) for 
    how to set Adjusting method on the setup menu. 
    						
    							38
    c  Attach the enclosure to the camera.
        Attach the cutout part of the main unit to the grooved part of the enclosure.
    IMPORTANT: 
      •  Securely tighten all the fixing screws (x3) of enclosure. Otherwise, water exposure may cause 
    damage or malfunction of camera, or camera dropping may result in injury. 
    (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft})
      •  Remove the protection sheet from the outside of the dome. 
    Groove for 
    mounting
    Cutout for 
    mounting 
    						
    							39
    Configure the network settings
    Configuring the camera so that it can be accessed from a PC
    The following are descriptions for when the camera with default settings is configured. If you 
    are using firewall software on your PC, the Setup Program may not be able to find any 
    cameras on your network. Configure the setting of the camera after temporarily invalidating 
    the firewall software. Contact the network administrator or your Internet service provider for 
    information about configuring the settings of the network.
    z Insert the provided CD-ROM into the CD-ROM drive of your PC.
      •  The License Agreement will be displayed. Read the Agreement and choose “I accept the 
    term in the license agreement”, and click [OK].
      •  The launcher window will be displayed. If the launcher window is not displayed, double 
    click the “CDLauncher.exe” file on the CD-ROM.
    Note: 
     •  Refer to “Using the CD-ROM” in the Operating Instructions on the provided CD-ROM for 
    further information about CDLauncher.
    x  Click the [Run] button next to [IP Setting Software].
      [Panasonic IP Setting] screen will be displayed. Click the [Network Settings] button after select-
    ing the MAC address/IP address of the camera to be configured. 
    						
    							40
    c  Select the camera you want to configure, and click [Access Camera].
    Note: 
     • When cameras are displayed in [Panasonic IP Setting] screen, click the camera with same 
    MAC address as the MAC address printed on the camera that you want to configure.
    v  If the installation screen of the viewer software “Network Camera View 4S” is displayed, follow 
    the instructions of the wizard to start the installation. (The viewer software is installed from the 
    camera.)
      •  The “Live” page will be displayed.
      •  If you cannot install the viewer software “Network Camera View 4S” or if images are not 
    displayed, click the [Install] button next to [Viewer Software] on the launcher window to 
    install the software.
      •  Perform the [Time & date] settings in the “Setup” - “Basic” page before using the camera.
    Note: 
     •  When no image is displayed on the “Live” page, refer to the Troubleshooting in the Operating 
    Instructions on the provided CD-ROM.
     •  It is possible to enhance the network security by encrypting the access to cameras using the 
    HTTPS function. Refer to the Operating instructions on the provided CD-ROM for how to con-
    figure the HTTPS settings.
      •  Click the [Setup] button on the “Live” page, the user authentication window will be displayed. 
    Enter the default user name and password as follows, and log in.
        User name: admin
      Password: 12345
      •  When changing settings related to the network settings, such as connection mode, IP address, 
    and subnet mask, click the [Network Settings] button in [IP Setting Software] screen as shown 
    in step 3, then change each setting.
      •  Due to security enhancements in “IP Setting Software”, “Network settings” of the camera to be 
    configured cannot be changed when around 20 minutes have passed after turning on the 
    power of the camera. (When the effective period is set to “20 min” in the “Easy IP Setup 
    accommodate period”.) 
        However, settings can be changed after 20 minutes for cameras in the initial set mode.
      • “Network Camera Recorder with Viewer Software Lite” which supports live monitoring and 
    recording images from multiple cameras is available. For further information, refer to our web-
    site (http://security.panasonic.com/pss/security/support/info.html). 
    						
    All Panasonic manuals Comments (0)