    Have a look at the manual Panasonic Network Camera Wv Sw314 Wv Sw316 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							31
    Note:
    	 •	 When	 shooting	 in	 the	 following	 place	 or	 the	 following	 subjects,	 focus	 may	 not	 be	 adjusted	 automatically. In this case, adjust the focus manually from the setup menu. Refer to the 
    Operating Instructions (included in the CD-ROM) for how to perform the manual focus adjust-
    ment from the setup menu. 
    	 •	 Subj.	with	large	illuminance	change	 •	 Subj.	moving	frequently
    	 •	 Subj.	with	reflection	or	extra	brightness	 •	 Subj.	with	low	illuminance
    	 •	 Place	where	the	front	cover	easily	becomes	dirty	 •	 Subj.	through	a	window
    	 •	 Subj.	with	less	contrast	such	as	white	wall	 •	 Subj.	with	heavy	flicker
    	 •	
    If the 2x extra optical zoom is applied when "1280x960", "1280x720" is s\
    elected for the image capture 
    size, the image quality will be deteriorated because the effect of Extra Optical Zoom is not provided. 
    	 •	 When	 images	 in	 the	 near-infrared	 light	 area	 change	 from	 color	 to	 black	 &	 white,	 out-of-focus	 may be occurred according to the nature of optical property. In this case, the focus can auto-
    matically be corrected by selecting "Auto" or "Preset" for "Adjusting method" on the setup 
    menu (The focus will not automatically be adjusted according to the illumination level change 
    once the focus is corrected.) Refer to the Operating Instructions (included in the CD-ROM) \
    for 
    how to set "Adjusting method" on the setup menu.
    
        FOCUS ADJUSTMENT    
       
     LOW       HIGH
      .......
    |............
    INDICATOR   775   BEST
     
    PEAK HOLD   780   FOCUSFocus ringZoom ring
    Focus lock knob Zoom lock knob
    Focus assist button (F.A.)/
    Extra optical zoom button
     
    q  Loosen the zoom lock knob and the focus lock knob, then move them to adj\
    ust for the appro-
    priate viewing angle of the target.
    Note:
    	 •	
    The focus may not be adjusted appropriately when the zoom ring is positioned at the "W"   
    (or "T") end. In this case, adjust the focus again by slightly moving \
    the zoom ring to the direction of "T" (or "W"). 
    						
    							32
     w  To adjust the angular field of view with a higher zooming effect even after adjusting the angular 
    field of view almost fully in the "T" direction, hold down the focus assist button (F.A.)/extra opti-
    cal zoom button for 5 seconds or more. 2x extra optical zoom will be applied. When the image 
    capture size under "VGA" is applied, the zoom factor can be adjusted up to 2x \
    without deterio-
    ration of image quality. When holding down the focus assist button (F.A.)/extra optical zoom 
    button again for 5 seconds or more, 1x extra optical zoom will be applied.
     e Tighten the zoom lock knob.
     r Press the focus assist (F.A.) button.
      
    →	 "FOCUS ADJUSTMENT" menu will be displayed.
         The focus assist function will be activated to perform the optimum adjus\
    tment.
     t When the focus lock knob is positioned near the best focus position, the\
     position will automati- cally be memorized as the "PEAK HOLD" position. (The closer the focus r\
    ing is positioned to 
    the best focus position, the greater the "PEAK HOLD" value becomes.)
     y When the focus lock knob is moved, the current focus position will be indicated on  "INDICATOR". Adjust the focus position so that the indicator value goes close t\
    o the "PEAK 
    HOLD" position.
     u When the indicator value goes to the best focus position, "BEST FOCUS" w\
    ill be displayed in  reverse at the lower right corner of the screen.
     i Tighten the focus lock knob so as to fix the best focus position.
     o Press the focus assist (F.A.) button again to close the "FOCUS ADJUSTMENT" menu.   (No operation for 3 minutes also closes the menu.)
    IMPORTANT:
    	 •	
    When using a model equipped with the focus assist (F. A.) function, defocus may be caused by the 
    dome cover attached. 
    In this case, the focus adjustment will be easier by detaching the dome \
    cover and moving the 
    focus ring to the "N" direction.
    	 •	 Before	attaching	the	dome	cover,	make	sure	that	the	subject	is	present.
    Note:
    	 •	 	If	 the	 zoom	 lock	 knob	 is	 fully	 rotated	 in	 the	 "W"	 direction,	 the	 periphery	 may	 become	 dark.	 In	 such a case, rotate the zoom lock knob in the "T" direction for readjustment.
    	 •	 	When	 shooting	 the	 following	 subjects,	 close	 the	 "FOCUS	 ADJUSTMENT"	 menu	 by	 pressing	 the focus assist (F.A.) button again, or adjust the focus to obtain the best focus positio\
    n while 
    monitoring images from the camera.
    		 		•	Place	where	the	front	cover	easily	becomes	dirty	 •	Subj.	moving	frequently
    		 		•	Subj.	with	large	illuminance	change	 •	Subj.	with	low	illuminance
    		 		•	Subj.	with	reflection	or	extra	brightness	 •	Subj.	through	a	window
    		 		•	Subj.	with	less	contrast	such	as	white	wall	 •	Subj.	with	heavy	flicker
    	 •	 	If	 the	 zoom	 lock	 knob	 is	 slightly	 tightened	 before	 the	 zoom	 is	 adjusted,	 the	 ring	 will	 become	 stable, making fine adjustments easier to perform.
    	 •	 	If	 the	 focus	 lock	 knob	 is	 slightly	 tightened	 before	 the	 focus	 is	 adjusted,	 the	 ring	 will	 become	 stable, making fine adjustments easier to perform.
    	 •	 	In	 case	 the	 angular	 field	 of	 view	 has	 changed	 during	 adjustment,	 close	 the	 "FOCUS	 ADJUSTMENT" menu once by pressing the focus assist (F.A.) button. (When the angular field 
    of view changes, the indicator values of "PEAK HOLD" and "INDICATOR" also change.) After 
    fixing the angular field of view, retry Step 3.
    	 •	
      If the 2x extra optical zoom is applied when "1280x960", "1280x720" is s\
    elected for the image capture 
    size, the image quality will be deteriorated because the effect of Extra Optical Zoom is not provided
    . 
    						
    							33
    Mount the front cover.
    Attach the desiccant (accessory) to the inner bottom side of the front cover along the guide rib, and 
    mount the front cover.
    Desiccant (accessory)Guide rib   Fixing screw x4
    (3)
    (1)
    (2) (4)
    IMPORTANT: 
    	 •	 Be	sure	to	attach	the	desiccant	(accessory).	Refer	to	the	instructions	for	the	desiccant	for	how	 to attach it. 
    SW314
    	 •	 The	tightening	torque	described	below	shall	be	followed	for	the	4	fixing	screws	of	front	cover.
      Recommended tightening torque: 0.59 N·m {0.44 lbf·ft}
    	 •	 The	tightening	sequence	of	the	4	fixing	screws	of	the	front	cover	shall	be	observed	and	repeat- ed twice as described in the illustration above.
       ((1) 
    →	(2) →	(3) →	(4), twice)
    	 •	 Make	 sure	 the	 packing	 has	 not	 come	 off	 or	 become	 askew.	 If	 this	 happens	 put	 it	 back	 into	
    place.
    	 •	 Make	sure	the	packing	has	no	dust	or	other	contaminants	on	it.	Remove	any	dust	or	contami- nants on the packing.
    	 •	
    Remove the cover film from the clear part of the front cover section after the installation is complete. 
    Do not touch the clear part of the front cover section by hand directly after removing the cover film.
    Mounting the front cover
    Fixing screw x4
    (3)(1)
    (2) (4) 
    						
    							34
    Attaching the mounting surface on the top surface of the camera body
    When the mounting surface is changed to the top surface of the camera bo\
    dy
    z Remove the 4 sunshield fixing screws from the camera body and remove the sunshield.
    x Remove the 4 tripod head fixing screws from the camera body and remove the tripod head.
    c Loosen the fixing screw x1 and remove the rear cover, and remove the cap.
    v Rotate each cable in the direction of the arrow (clockwise) as illustrated and pass them between 
    opening in the upper groove of the main body.
      Then, attach the cap to the lower groove, and secure the rear cover with the fixing screw x1.
    Attach the rear cover to the front cover by hooking attachment hole 1 of the rear cover to the tab on the 
    front cover while passing the protrusion of the front cover through attachment hole 2 of the rear cover.
    Upper groove
    Ta
    b
    Protrusion
    Cap
    Attachment hole 1 Attachment 
    hole 2
    Tripod head fixing screw x4 Tripod head
    (This illustration represents WV-SW316.) (This illustration represents WV-SW316.)
    Rear coverF
    ixing screw x1 
    						
    							35
    b  Mount the tripod head on the top of the camera body with the 4 tripod he\
    ad mounting screws 
    that were removed in the step 2.
    IMPORTANT: 
    	 •	 Caution	shall	be	taken	to	prevent	each	cable	from	being	caught	between	the	camera	body	and	 tripod head.
    	 •	 Be	sure	to	use	the	screws	that	were	removed	from	the	tripod	head.
       Recommended tightening torque: 0.59 N·m {0.44 lbf·ft}
    n  Secure the camera to the camera mount bracket with the camera fixing screws x3 (accessory). 
    Pass each cable and the safety wire through the camera mount bracket, and connect the safe-
    ty wire to the camera mount bracket. Then, bundle the wire and the cable using the cable 
    clamp and secure them with each screw from the mounting boss to the camera mount bracket 
    (
    ☞ page 20-21).
    Camera main body
    Tripod head fixing screw x4
    (M3x10)
    Camera fixing screw x3 (M4 x 8) 
    (accessories)
    Camera mount bracket
    IMPORTANT: 
    	 •	 Be	sure	to	use	the	screws	that	were	removed	from	the	camera	mount	bracket.	
       Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}
    	 •	 Be	sure	to	use	the	screws	that	were	removed	from	the	safety	wire.
       Recommended tightening torque: 0.59 N·m {0.44 lbf·ft}
    (This illustration represents WV-SW316.) 
    						
    							36
    m  Remove the sunshield backside.
    As illustrated, opening up the sunshield in both directions makes it easier to remove the rear 
    part of the sunshield.
    •	When installing the camera to a ceiling, the rear part of the sunshield and the fixing screws  are not used.
    Rear part of sunshield
    Fixing screw x2
    ,  
    Mount the sunshield on the camera body with the 4 sunshield mounting scr\
    ews after removing 
    the sunshield backside.
    •	The sunshield is attached to the camera by inserting the protrusions on the rear cover of the  camera into the attachment holes on the rear part of the sunshield.
    Rear part of sunshield ProtrusionAttachment hole
    IMPORTANT: 
    	 •	 Be	sure	to	use	the	screws	that	were	removed	from	the	sunshield.
       Recommended tightening torque: 0.59 N·m {0.44 lbf·ft}
    (This illustration represents WV-SW316.) 
    						
    							37
    Using the CD-ROM
    About the CD launcher
    Insert the provided CD-ROM into the CD-ROM drive of your PC to start up the CD launch\
    er. Then the 
    License Agreement will be displayed.
    	 •	 Read  the Agreement and choose "I accept the term in the license agreement", and click [OK]. 
    Then the launcher window will be displayed.
    	 •	 If	 the	launcher	 window	is	not	 displayed,	 double	click	the	"CDLauncher.exe"	 file	on	the	 CD-ROM.
    q
    e
    t w
    r
    Using	the	supplied	CD-ROM,	the	following	actions	can	be	performed.
     
    q	 The	Panasonic	IP	setting	software	can	be	installed	on	the	PC.
           → Refer	to	"Installing	Panasonic	IP	setting	software".	(
    ☞ Page 38)
     w Settings	related	to	the	camera's	network	can	be	set	from	the	Panasonic	IP	setting	software.
           → Refer	to	"Configure	the	network	settings".	(
    ☞ Page 40)
     e The	manuals	can	be	installed	on	the	PC.
           → Refer	to	"Installing	the	manuals".	(
    ☞ Page 39)
     r Yo u 	can	also	view	the	manuals	without	installing	them	to	the	PC	by	clicking	the	[Open]	button. 
    Yo u 	can	select	to	view	the	manuals	or	"Notes	on	Windows
    ® / Internet Explorer®	versions"	from	
    the	displayed	menu.
     t The	Viewer		software	can	be	installed	on	the	PC.
           → Refer	to	"Installing	the	Viewer		software".	(
    ☞ Page 39)
    Make	sure	to	read	the	readme	file	on	the	provided	CD-ROM	before	using	the	software.		 
    						
    							38
    Installing Panasonic IP setting software
    On	the	 CD	 launcher	 window,	click	the	[Install]	 button	next	to	[IP	 Setting	 Software]	 to	display	 the	
    Panasonic	 IP	setting	 software	 installation	 window.	Confirm	the	following	 settings	before	starting	 the	installation.
    q
    e w
    r
     q Select	 the	Panasonic	 IP	setting	 software	 to	install.
     w Select	 where	to	create	 the	Panasonic	 IP	setting	 shortcut	 icon	when	 the	Panasonic	 IP	setting	 software	 is	installed. e Specify	 which	folder	on	the	 PC	to	install	 the	Panasonic	 IP	setting	 software	 to.
     r Click	 the	[Install]	 button	to	start	 the	installation.
    Note:
    	 • 	 To 	uninstall	the	Panasonic	IP	setting	software	delete	the	shortcut	icon	from	where	you	specified	
    it to be installed (the default is on the desktop) during installation\
     and the [EasyIPConfig] folder 
    from the folder you specified during Panasonic IP setting software installation.
             
    						
    							39
    Installing the manuals
    On	the	CD	launcher	window,	click	the	[Install]	button	next	to	[Manual]	to	display	the	Manual	installa-tion	window.	Confirm	the	following	settings	before	starting	the	installation.
     q Select	which	manuals	to	install.	The	camera	models	that	the	manuals	support	 are	displayed	in	
    w	"Model	List".
     w The	camera	models	that	are 	supported	by	the	manuals	selected	in	q	are 	displayed	here.
     e Select	where	to	create	the	manuals	shortcut	icon	when	the	manuals	are 	installed.
     r Specify	which	folder	on	the	PC	to	install	the	manuals	to.
     t Click	the	[Install]	button	to	start	the	installation.	
    Note:
    	 • 	 To 	uninstall	the	manuals	delete	the	shortcut	icon	from	where	you	specified	it	to	be	installed	(the	
    default is on the desktop) during installation and the [Manual] folder \
    from the folder you 
    specified during the manuals installation.
    Installing the Viewer software
    The	 Viewer	 software	 (Network	 Camera	 View4S)	 must	 be	 installed	 on	 the	 PC	 in	 order	 to	 display	
    camera	images.	On	the	CD	launcher	window,	click	the	[Install]	button	next	to	[Viewer	Software],	and	
    follow	 the	 instructions	 displayed	 on	 the	 window	 to	 install	 the	 software.	 A	 message	 is	 displayed	 if	 a	 PC	that	does	not	have	the	Viewer	software	installed	tries	to	access	the	camera.	Install	the	software	by	 following	 the	 instructions	 displayed	 on	 the	 window.	 Refer	 to	 "Viewer	 software"	 in	 the	 Operating	
    Instructions	for	further	information.
    Note:
    	 • 	 To 	uninstall	the	Viewer	software,	follow	the	steps	below	for	depending	on	the	OS	used	on	your	
    PC.
    Windows XP: Delete [Network Camera View 4S] from [Control Panel]-[Add or Remove Programs].
    Windows Vista/Windows 7: Delete [Network Camera View 4S] from [Control Panel]-[Programs]-[Uninstall a program].
    q
    r e
    w
    t 
    						
    							40
    Configure the network settings of the camera using the 
    Panasonic IP setting software
    It	is	possible	to	perform	the	network	settings	of	the	camera	using	the	IP	setup	software	on	the	pro-
    vided	 CD-ROM.	 When	 using	 multiple	 cameras,	 it	 is	 necessary	 to	 configure	 the	 network	 settings	 of	 each	camera	independently.	
    If	 the	 Panasonic	 IP	 setting	 software	 does	 not	 work,	 configure	 the	 network	 settings	 of	 the	 camera	and	 the	 PC	 individually	 on	 the	 "Network"	 page	 of	 the	 setup	 menu.	 Refer	 to	 the	 Operating	
    Instructions	(included	in	the	CD-ROM)	for	further	information.
    IMPORTANT: 
    	 •	 When	 using	 Microsoft	 Windows	 7	 or	 Microsoft	 Windows	 Vista,	 the	 "Windows	 Security	 Alert"	 window	 may	 be	 displayed	 when	 starting	 the	 IP	 setup	 software.	 In	 this	 case,	 disable	 "User	Account	Control"	from	the	control	panel.
    	 •	 For	the	security	enhancement,	the	MAC	address/IP	address	of	the	camera	to	be	configured	will	 not	be	displayed	when	around	20	minutes	have	passed	after	turning	on	the	power	of	the	cam-era.	(When	the	effective	period	is	set	to	"20min"	in	the	IP	setup)
    	 	 However	cameras	in	the	initial	set	mode	are 	still	displayed	even	after	20	minutes.
    	 •	 Panasonic	IP	setting	software	is	inoperable	in	other	subnets	via	the	same	router.
    	 •	 This	 camera	cannot	be	displayed	 or	set	 with	 an	older	 version	 of	the	 IP	setup	 software	 (version	2.xx).
    z	 	To 	 start	 the	 Panasonic	 IP	 setting	 software,	 click	 the	 [Run]	 button	 next	 to	 [IP	 Setting	 Software]	
    from	 the	 CD	 launcher	 menu	 window,	 or	 double-click	 on	 the	 shortcut	 icon	 created	 after	 install-
    ing	the	software	on	the	PC.
    	 •	 The	License	Agreement	will	be	displayed.	Read	 the Agreement and choose "I accept the term 
    in the license agreement", and click [OK].
    x	 	Click	the	[Network	Settings]	button	after	select-ing	the	MAC	address/IP	address	of	the	camera	
    to	be	configured.	
    Note:
    	 •	 When	 using	a	DHCP	server,	 the	IP	address	 assigned	 to	the	 camera	 can	be	displayed	 by	clicking	 the	
    [Search]	 button	of	the	 IP	setting	 software. 	
    	 •	 When	a	 duplicate	IP	address	 is	used,	 the	corresponding	 camera	number	 will	be	displayed	 shaded.	
    	 •	 When	 the	[Access	 Camera]	 button	is	clicked,	 live	images	 of	the	 selected	 camera	will	be	displayed.
    	 •	 It	 is	possible	 to	change	 the	"Camera	 list"	display	 between	 IPv4	addresses	 and	IPv6	 addresses	 in	
    accordance	 with	the	protocol	 in	use.
    	 •	 The	 information	 displayed	can	be	sorted	 by	clicking	 the	title	 of	each	 displayed	 item.
    Configure the network settings 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Network Camera Wv Sw314 Wv Sw316 Installation Guide