Have a look at the manual Panasonic Network Camera Recorder Single Camera Version Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Operating Instructions 71 7.Select the location, and click [OK]. JPEG conversion is started. If JPEG conversion is complete, the following window is displayed. JPEG-converted images are saved into the created folder in the location. The folder is created for each 1,000 images. Notes If you do not set the time, all selected images are converted to JPEG files. If it is canceled, images are saved till it is canceled.
Operating Instructions 72 2.13 Other Features 2.13.1 Importing the Camera Information This software can import the camera information. The camera information can be imported to this software on another PC. 1.Select [Tools] [Import Camera Settings] on the menu bar. The import file selection window is displayed. To import the camera information from BB-HNP60, select [BB-HNP60 Camera Definition File] at the file type. To import from this software, select [Camera Definition File]. 2.Select a file and click [Open]. The camera information is imported. Notes This software can import camera information from BB-HNP60 or this software. Setting information cannot be imported if you cannot access the target camera for the setting information. 2.13.2 Exporting the Camera Information This software can export the camera information. The camera information can be exported for this software on another PC. 1.Select [Tools] [Export Camera Settings] on the menu bar. The export file save window is displayed. 2.Select the location, and click [Save]. The camera information is exported.This software: All camera information can be imported. BB-HNP60: Basic settings and image settings can be imported. BB-HNP60 setting information file is saved in the destination folder.
Operating Instructions 73 2.13.3 Copying the Recorded Images This software can copy the monitoring image to the clipboard. 1.Right-click the image on the monitoring page. The copy menu is displayed. 2.Click [Copy]. This software copies the image to the clipboard. Notes The clipboard is a place to temporarily save in copying or pasting data. The copied image can be used in the program such as Paint. You can copy the image by selecting [Edit] [Copy] on the menu bar. 2.13.4 Changing the Keyword of the Recorded Images You can change the keyword set to the recorded images. 1.Select a camera preview on the camera list. Selected camera is displayed in a blue frame (see page 66). 2.Select an image to change the keyword on the recorded image page. 3.Select [Recorded Images] [Edit Keyword] on the menu bar. You can select [Edit Keyword] from the menu displayed by right-clicking recorded image. The keyword change window is displayed. 4.Change the keyword, and click [OK]. The keyword is changed.
Operating Instructions 74 2.13.5 Deleting the Recorded Images 1.Select a camera preview on the camera list. Selected camera is displayed in a blue frame (see page 66). 2.Select the recorded images to delete on the recorded image page. You can select multiple images. 3.Select [Recorded Images] [Delete] on the menu bar. You can select [Delete] on the menu displayed by right-clicking the recorded image. The confirmation window is displayed. 4.Click [OK]. The selected images are deleted. Note This software can delete 100 images at a time. If images to delete exceeds 100, repeat the deletion.
Operating Instructions 75 2.14 Error Message List Message Cause and Remedy Basic Setting Enter Camera Name. The Camera Name space was blank. Follow the instruction message. Enter Camera Address. The Camera Address space was blank. Follow the instruction message. Port should be between 1 and 65535. A number not between 1 and 65535 was entered in the Port blank. Follow the instruction message. Camera Name should be 250 characters or less. The Camera Name was more than 250 characters. Follow the instruction message. Comment should be 128 characters or less. The Comment was more than 128 characters. Follow the instruction message. Image Settings Specify Recorded Frequency and Sound Recording cannot be selected simultaneously. Either set Recorded Frequency to [Not Specify] or set the recording settings to [Image Only]. Image settings are set to [Recorded Frequency Specify], and [Audio and Image] are selected simultaneously. Or if another tab or OK is pressed in this state. Follow the instruction message. Recording Capacity Enter Recording Capacity. The Recording Capacity space was blank. Follow the instruction message. Recording Capacity should be between 100 and 500000. A number not between 100 and 50000 was entered in the Recording Capacity blank. Follow the instruction message.
Operating Instructions 76 Message Cause and Remedy Keyword Keyword 1 should be 40 characters or less. Keyword 1 was more than 40 characters. Follow the instruction message. Keyword 2 should be 40 characters or less. Keyword 2 was more than 40 characters. Follow the instruction message.
Operating Instructions 77 Message Cause and Remedy Parameter Error An error has occurred in the XXXX parameter in Create New Camera (Camera Registration Information). Try again. XXXX = Camera ID Camera Name Comment Camera Address Camera Address Port User Name Password Using Proxy Resolution Image Quality Recorded Frequency Audio Recording Settings Limit the Recording Capacity Recording Capacity Motion when Reaching the Recording Capacity Recording Flag before Motion Detection Number of Seconds before Motion Detection Recording Flag after Motion Detection Number of Seconds after Motion Detection Sensitivity Threshold Keyword 1 Keyword 2 Camera Type This is a software error. If same error message appears after trying again, restart your PC.
Operating Instructions 78 Timer Setting Message Cause and Remedy Basic Setting Enter Timer Name. Timer Name space was blank. Follow the instruction message. Select a day of the week. There is a check in the Day Specification Radio Button but no check in any of the Day Buttons. One day or more must be selected. Timer Name should be 24 characters or less. Timer Name was more than 24 characters. Follow the instruction message. Keyword Keyword 1 should be 40 characters or less. Keyword 1 was more than 40 characters. Follow the instruction message. Keyword 2 should be 40 characters or less. Keyword 2 was more than 40 characters. Follow the instruction message.
Operating Instructions 79 Preferences Message Cause and Remedy Parameter Error An error has occurred in the XXXX parameter in Create New Timer (Timer Registration Information). Try again. XXXX = Camera ID Timer ID Timer Name Daily/Weekly Setting Day of the Week Start Time End Time Recording Method Recording Flag before Motion Detection Number of Seconds before Motion Detection Recording Flag after Motion Detection Number of Seconds after Motion Detection Keyword 1 Keyword 2 This is a software error. Check that the correct information is inputted into each error heading. Message Cause and Remedy Destination Enter Minimum Free Disk Space. Hard Disk Capacity space was blank. Follow the instruction message. Minimum Free Disk Space should be between 100 and 50000. A number not between 100 and 50000 was entered in the Hard Disk Capacity blank. Follow the instruction message.
Operating Instructions 80 Minimum Free Disk Space should be less than the current free space (*** MB). The free space on the disk is larger than the free space on the drive. Follow the instruction message. Select Save Destination Folder. Save Destination Folder Path space was blank. Follow the instruction message. Backup Enter Minimum Free Disk Space. Minimum Free Disk Space field was blank. Follow the instruction message. Minimum Free Disk Space should be between 100 and 50000. A number not between 100 and 50000 was entered in the Minimum Free Disk Space blank. Follow the instruction message. Minimum Free Disk Space should be less than the current free space (XXX MB). The free space on the disk is larger than the free space on the drive. Follow the instruction message. Select Backup Folder. The Backup Destination Folder Path space was blank. Follow the instruction message. Network Enter Proxy Server Address. [Use a proxy server] is checked and the Address space was blank. Follow the instruction message. Port should be between 1 and 65535. A number not between 1 and 65535 was entered in the Port blank. Follow the instruction message. Message Cause and Remedy