    [For assistance, please call: 1-800-272-7033]                                 91
    4.2 Interfacing to the External I/O
    The Alarm mode in the Image Transfer feature requires the external sensors/
    devices to be connected to the External Sensor Input of the External I/O. Certain 
    features of this Network Camera can be activated by an external sensor that 
    senses physical changes in the area Network Camera is monitoring. These 
    changes can include motion detection or a physical change in the monitored area. 
    The external sensor can also be a door switch or an infrared motion detector. 
    These devices are customer provided, and are available from dealers who carry 
    surveillance and security products. Electrically, they must be able to provide a 
    momentary contact closure.
    Explanation of External I/O
    Pin Function
    1GND
    2DC Power Output Terminal
    8—12 V DC
    Maximum of 50 mA load drive is possible.
    3 External Sensor Input
    External Sensor Input receives the signal produced by the alarm 
    sensors, (e.g., door sensor, infrared ray sensor). Those signals can 
    activate Image Transfer in the Alarm mode feature on page 64.
    Use it by opening or GND short-circuit.
    4 External Device Control Output
    External Device Control Output sends the electric current to activate 
    the external devices, (e.g., light, buzzer).
    External Output Control window can set the External Device Control 
    Output. Refer to page 78.
    It is an open collector circuit, and the maximum drawing-in current is 50 
    mA. Prevent the maximum voltage from exceeding DC Power Output 
    voltage of pin 2. 
    						
    							Operating Instructions
    92
    Circuit Diagram Example
    CAUTION
    THE EXTERNAL I/O IS NOT CAPABLE OF CONNECTING DIRECTLY 
    TO DEVICES THAT REQUIRE LARGE AMOUNTS OF CURRENT. IN 
    SOME CASES, A CUSTOM INTERFACE CIRCUIT (CUSTOMER 
    PROVIDED) MAY HAVE TO BE USED. SERIOUS DAMAGE TO 
    NETWORK CAMERA MAY RESULT IF A DEVICE IS CONNECTED 
    TO THE EXTERNAL I/O THAT EXCEEDS ITS ELECTRICAL 
    CAPABILITY.
    THE LOW VOLTAGE/CURRENT CIRCUITS AND HIGH VOLTAGE/
    CURRENT CIRCUITS ARE IN THE NETWORK CAMERA CIRCUIT. 
    THE QUALIFIED ELECTRICIAN SHOULD DO THE WIRING NOT BY 
    YOURSELF. INCORRECT WIRING COULD DAMAGE NETWORK 
    CAMERA. YOU COULD RECEIVE THE FATAL ELECTRIC SHOCK.
    External I/O (Input/Output) are independent. Output terminal is 
    controlled only by External Output Control window on page 78.
    Light
    Door Sensor Relay
    Network Camera
    8  12 VDC4
    3
    2
    1 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033]                                 93
    4.3 ASCII and ISO-8859-1 Character Table
    The characters of the ASCII character table are available for use in the various 
    setup windows.
    IP addressing (Assignment of the IP address)
    Address consists of one to four numbers (0—255). By far most common form 
    is four decimal numbers, (e.g., 192.168.0.253). 
    (0.0.0.0 and 255.255.255.255 are not available.)
    Unavailable character set 1
    [Space], [], [], [#], [&], [%], [=], [+], [?], [] and [:] are not available.
    Unavailable character set 2
    [Space], [], [], [#], [&], [%], [=], [+], [?], [] and [:] are not available. 
    Character set is like [text] + [@] + [text] + [.] + [text].
    (space)
    !
    
    #
    $
    %
    &
    
    (
    )
    *
    +
    ,
    -
    .
    /0
    1
    2
    3
    4
    5
    6
    7
    8
    9
    :
    ;
    <
    =
    >
    ?
    ASCII Character Table
    @
    A
    B
    C
    D
    E
    F
    G
    H
    I
    J
    K
    L
    M
    N
    OP
    Q
    R
    S
    T
    U
    V
    W
    X
    Y
    Z
    [
    \
    ]
    ^
    _`
    a
    b
    c
    d
    e
    f
    g
    h
    i
    j
    k
    l
    m
    n
    op
    q
    r
    s
    t
    u
    v
    w
    x
    y
    z
    {
    |
    }
    ~ 
    						
    							Operating Instructions
    94
    Displayable character set
    Network Camera can display ISO-8859-1 character set for West European 
    languages and the Shift-JIS character set for Japanese. Network Camera 
    screen may display the unreadable characters if the operating system or the 
    entered character set is different from the language selected on Top View 
    Image Setting window.
    ¡
    ¢
    £
    ¤
    ¥
    ¦
    §
    ¨
    ©
    ª
    «
    ¬
    -
    ®
    ¯
    ±
    ²
    ³
    ´
    µ
    ¶
    ·
    ¸
    ¹
    º
    »
    ¼
    ½
    ¾
    ¿
    ISO-8859-1 Character Table
    À
    Á
    Â
    Ã
    Ä
    Å
    Æ
    Ç
    È
    É
    Ê
    Ë
    Ì
    Í
    Î
    ÏÐ
    Ñ
    Ò
    Ó
    Ô
    Õ
    Ö
    ×
    Ø
    Ù
    Ú
    Û
    Ü
    Ý
    Þ
    ßà
    á
    â
    ã
    ä
    å
    æ
    ç
    è
    é
    ê
    ë
    ì
    í
    î
    ïð
    ñ
    ò
    ó
    ô
    õ
    ö
    ÷
    ø
    ù
    ú
    û
    ü
    ý
    þ
    ÿ 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033]                                 95
    4.4 Maintenance
    To keep Network Camera functioning in good condition, maintenance plays an 
    important part. Keep maintenance when using Network Camera. After removing 
    dust from the Fixed Focus Lens, wipe the Fixed Focus Lens with lens cleaning 
    paper.
    Fixed Focus Lens
    Do not forcedly move the lens part around the Fixed Focus Lens. Touching 
    it may damage the Pan/Tilt motor.
    Do not touch the Fixed Focus Lens. Touching it may leave a fingerprint and 
    can cause the image to be out of focus, and may also remove the protective 
    coating from the Fixed Focus Lens.
    Clean the Fixed Focus Lens with lens cleaning paper.
    Fixed Focus Lens Lens cleaning 
    paper 
    						
    							Operating Instructions
    96
    Section 5
    Specification and Troubleshooting 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033]                                 97
    5.1 Network Camera Reset Procedure—Default 
    Settings
    If the user forgets settings or passwords, Network Camera can be easily reset to 
    the default settings. The CLEAR SETTING button initializes all the parameters 
    except Date and Time setting.
    With power on
    , press the CLEAR SETTING button for about one second. 
    Note
    When pressing the CLEAR SETTING button, all buffered images are cleared.
    CLEAR SETTING button
    (Press the button with a 
    pointed object) 
    						
    							Operating Instructions
    98
    5.2 Default Settings List
    No ItemsFactory Default
    valueIndispensable setting Note1 Network1. Network Configuration Checked - -
    2. Port No. 80 - 1–65535
    Static : IP Address 192.168.0.253 If necessary
    If necessary
    If necessary(*1)
    (*1)
    (*1)
    (*1)Static : Subnet Mask 255.255.255.0DHCP : Host Name [Blank] (*3) 0 to 63 Characters
    3. Default Gateway [Blank] Required when using Gateway4. DNS Server1 & DNS server 2 [Blank] Required when using DNS
    Required when using DDNS5. DDNS No check - -
    Your e-mail address [Blank] (*4) 5 to 255 Characters
    6. Max Bandwidth usage (Mbps) Unlimited - 0.1, 0.2, 0.3, 0.5, 1.0,Unlimited
    2 Name/Time1. Camera Name NetworkCamera - (*3) and (*7) 1 to 15 Characters
    2. Date and Time
    (AM/PM, 24H)AM/PM - -2. Date and Time
    (Year/Month/Day/Hour/Minute)No changing - -3.
    Auto Adjustment
    No check - -
    3
    NTP Server Address or Host Name
    [Blank] - (*1) or (*3) 1 to 255 Characters
    Time Zone GMT-05:00 - -
    1. Authentication Enable None - -
    Security:
    Administrator
    2. ID [Blank] Required when setting Authentication
    Required when setting Authentication
    Required when setting Authentication(*3) 4 to 15 Characters
    Password [Blank] (*3) 4 to 15 CharactersRetype Password [Blank] (*3) 4 to 15 Characters
    4(1.) User ID List No entry - -
    Security:
    General User
    5
    Top View Image 
    Setting(2.) New User: ID [Blank] Required when setting General User
    Required when setting General User
    Required when setting General User(*3) 4 to 15 Characters
    New User: Password [Blank] (*3) 4 to 15 CharactersNew User: Retype Password [Blank] (*3) 4 to 15 Characters
    1. Language English (US) -French, German, Italian, 
    Spanish, Japanese, etc.
    2. Top Page title [Blank] -
    -
    -
    (*6) and (*7) 0 to 63 Characters
    Image URL [Blank] (*8) 0 to 127 Characters
    Link URL [Blank] (*8) 0 to 127 Characters 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033]                                 99
    No ItemsFactory Default
    valueIndispensable setting Note5 Top View Image320 x 240 - 160 x 120, 320 x 240, 640 x 480
    SettingImage Quality Standard -Favor Clarity, Standard,
    Favor Motion
    Refresh Interval
    30 s-10, 15, 20, 25, 30,45 s,
    1, 2, 3, 5 min
    320 x 240 - 160 x 120,320 x 240
    Image Quality Standard -Favor Clarity, Standard,
    Favor Motion
    5. Limit time of Continuous Motion JPEG
    Unlimited - 10 s—Unlimited
    6. Always/Operational betweenAlways - -
    0h 0min — 0h 0min - -
    All checked - -
    Time 1 — 4
    Day-of-the-week setting Refresh Interval
    30 s-10, 15, 20, 25, 30,45 s,
    1, 2, 3, 5 min
    3. Single Camera Image Resolution
    4. Multi-Camera Image Resolution
    6 Image Transfer
    1. Trigger SettingNon transfer - -
    1. Non transferEnable - -
    Always - -
    1. Alarm
    Start time 00:00:00 - -
    Stop time 23:59:59 - -Day-of-the-week setting All checked - -Alarm enable condition Rising - -(2)Secondary Time No check - -Alarm enable condition, Rising - -
    320 x 240 - 160 x 120, 320 x 240, 640 x 480
    (2) Image Quality Standard -Favor Clarity, Standard,
    Favor Motion
    2. Capture Control
    2. (1) Always/Operational between
    3. (1) Image Resolution
    4. (1)Pre-alarm Image Buffer No check - -
    Image Frequency 1 Image/Hour -
    --Maximum number of image per
    each trigger11—400(2)Post-alarm Image Buffer Checked - -Image Frequency 1 Image/Hour -
    --Maximum number of image per
    each trigger1
    1—400 
    						
    							Operating Instructions
    100
    No ItemsFactory Default
    valueIndispensable setting Note6 1. Alarm5.
    Non Transfer without Memory Over Write
    Non Transfer with Memory Over Write
    Selected - -Not-selected - -
    FTP Not-selected - -
    Server Address or
    Host Name[Blank] Required when using FTP
    Required when using FTP
    Required when using FTP(*1) or (*3) 1 to 255 CharactersPort No. (Usually Use 21) 21Login ID [Blank] If necessary
    If necessary(*3) 0 to 63 CharactersPassword [Blank] (*3) 0 to 63 CharactersUpload File Name [Blank] (*3) 1 to 234 Characters
    -
    Login timing Every Time Every Time, One Time
    Over write settingOver Write to Fixed
    Upload File Name-Mail Not-selected - - Data transfer method Passive Mode Passive Mode, Active Mode--SMTP Server Address or Host Name [Blank] Required when using Mail
    Required when using POP authentication
    Required when using POP authentication
    POP3 Server Address or Host Name [Blank] (*1) or (*3) 1 to 255 CharactersLogin ID [Blank] (*3) 0 to 63 CharactersPassword [Blank] (*3) 0 to 63 Characters
    Required when using POP authentication
    (*1) or (*3) 1 to 255 Characters
    Required when using POP authentication
    Required when using POP authentication
    POP3 Server Address or Host Name [Blank] (*1) or (*3) 1 to 255 CharactersLogin ID [Blank] (*3) 0 to 63 CharactersPassword [Blank] (*3) 0 to 63 Characters
    Required when using POP authentication
    Required when using Mail
    Required when using Mail
    Required when using Mail From (Reply) [Blank] (*4) 5 to 63 Characters
    To [Blank] (*4) 5 to 63 CharactersSubject [Blank] (*2) and (*7) 0 to 44 CharactersText [Blank] (*2) and (*7) 0 to 63 Characters6. No Message Selected --
    -
    -Mail Not-selected - -SMTP Server Address or Host Name [Blank] (*1) or (*3) 1 to 255 Characters
    Required when using Mail
    Required when using Mail
    -
    - From (Reply) [Blank] (*4) 5 to 63 Characters
    To [Blank] (*4) 5 to 63 CharactersSubject [Blank] (*2) and (*7) 0 to 63 CharactersText [Blank] (*2) and (*7) 0 to 63 Characters