Page 71
Operating Instructions [For assistance, please call: 1-800-272-7033] 71 Instructions for the data fields a.Buffers or transfers by the timer trigger. b.Active Time of Trigger Always: always activates the timer trigger. The timer trigger interval can be set in e. Image Buffer Frequency Setting. Operational between: Sets the start and stop time of the primary time. The day of the week can be set by checking. If the setting time passes over midnight, check the check box...
Page 72
Operating Instructions 72 a.Selects Transfer Method. Non Transfer without Memory Over Write: Image buffering will stop when the internal memory is full. Non Transfer with Memory Over Write: Buffered image will overwrite the older image data when the internal memory is full. [Primary] or [Secondary] on the operation bar can be displayed to view the Buffered Image screen in Non Transfer setting. FTP: Enters the server address* 1 or Host Name*2, Port Number (1— 65535), Login ID*2 and password*2 to...
Page 73
Operating Instructions [For assistance, please call: 1-800-272-7033] 73 Over write setting: Selects [Over Write...] to overwrite the transferred image or [Add time...] to save each transferred image. Data transfer method: Use [Passive Mode] normally. If FTP does not work properly, ask your ISP or network administrator about the transferring mode of FTP server. [Passive Mode] or [Active Mode] is available. b.Mail: Sets the SMTP and POP3 server address*1 or Host Name*2,...
Page 74
Operating Instructions 74 3.5.8 Camera Setup Camera Setup window sets White Balance and Power Line Frequency. You can lock the Brightness feature. 1.Click [Camera Setup] on Setup Page. 2.Select the each parameter in the proper data field. Click [Save] when finished. Click [Cancel] to quit the current settings. The window returns to the Setup Page without saving the parameters.
Page 75
Operating Instructions [For assistance, please call: 1-800-272-7033] 75 Instructions for the data fields White Balance Auto (default)—Auto White Balance Fixed Indoor—Color Temperature: 2800K, Electric Bulb Fixed Fluorescent_1—Color Temperature: 3600K, Natural fluorescent light Fixed Fluorescent_2—Color Temperature: 4000K, Natural fluorescent light Fixed Outdoor—Color Temperature: 6000K, Solar light Hold—Holds the current White Balance Notes The wrong White Balance...
Page 76
Operating Instructions 76 3.5.9 Multi-Camera Multi-Camera window enables the setting of Multi-Camera screen. Camera Name and IP address of each Network Camera must be entered to view the Multi- Camera screen. Registering IP addresses of the other Network Camera enables you to view on the Multi-Camera screen. Clicking Camera Name of Network Camera on the Multi-Camera screen accesses the Single Camera screen to control the image. First Network Camera is named on Name/Time window on page 54. 2nd to 4th...
Page 77
Operating Instructions [For assistance, please call: 1-800-272-7033] 77 2.Select/Enter the each parameter. Click [Save] when finished. Click [Cancel] to quit the current settings. The window returns to Setup Page without saving the parameters. * 1 Refer to IP addressing on page 93. * 2 Refer to unavailable character set 1 on page 93 but [:] is available. * 3 Refer to unavailable character set 1 on page 93 and refer to displayable character set on page 94.Instructions for...
Page 78
Operating Instructions 78 3.5.10 External Output Control External Output Control window enables the External Device Control Output signal to activate the external sensors/devices. (Open or Short to GND) The network administrator should set up this setting. Note Refer to page 91 for Interfacing to the External I/O. 1.Click [External Output Control] on Setup Page. 2.Check [Open] means the External Device Control Output becomes high impedance (open collector). Check [Short to GND] means the External...
Page 79
Operating Instructions [For assistance, please call: 1-800-272-7033] 79 3.5.11 Indicator Control Indicator Control window allows you to select Power Indicator operation. Power Indicator operation has three patterns. Always on Turns on when accessing Network Camera Always off Notes Power Indicator can be controlled in case the administrator does not want to draw attention to Network Camera. This may be desirable when used for security applications. Indicator Control...
Page 80
Operating Instructions 80 3.5.12 Status Status displays general information about Network Camera. Note When some trouble occurs, the information is useful.