Panasonic Network Camera Kx Hcm280 Operating Instructions
Have a look at the manual Panasonic Network Camera Kx Hcm280 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Operating Instructions [For assistance, please call: 1-800-272-7033] 71 Instructions for the data fields Top Page•Top Page title can be changed. Enter the new title. •Refer to unavailable character set 1 on page 105 but [space] is available. •Refer to displayable character set on page 106. •Network Camera picture on Top Page can be changed. Enter the URL (http://) to display the picture on the specified web site. •Only [space] and [] are unavailable in the ASCII character table on page 105. •Network Camera picture on Top Page can be set the link to the specified web site. Enter the URL (http://). •Only [space] and [] are unavailable in the ASCII character table on page 105. Image Resolution•640 x 480 (cannot set on the Multi-Camera screen.) •320 x 240 (default) •160 x 120 Image Quality•Favor Clarity: Image is optimized for good clarity. •Standard: Image quality is standard. (default) •Favor Motion: Image is optimized for enhanced motion display. Refresh IntervalThe refresh interval of JPEG - Regularly Refresh can be selected. Select the desired interval. •10 seconds to 5 minutes Limit time of Continuous Motion JPEGTo make the network traffic smooth, select the duration time to display Motion JPEG. When the timer expires, the image changes to JPEG - Regularly Refresh. •10 seconds to Unlimited On the Air timeSpecifies the timetable to allow users to access Top View Image screen. When you access the image except the specified time, blue screen appears. •Always: Always allows users to access. •Operational between: Specifies the date and time to access the image.
Operating Instructions 72 3.6.7 Image Transfer Image Transfer window can set the Image Transfer feature. Network Camera can buffer images and send the images via e-mail or FTP. The request to send the image is initiated by a contact closure from the external sensors/devices connected to the External I/O using the Alarm mode. The external sensors/ devices are customer provided. The images can also be sent in the interval of time using the Timer mode. Make sure Date and Time has been configured. Refer to page 64 about Date and Time. Note When you use FTP or e-mail in transferring the image, you need to set Default Gateway and DNS Server address. Note The Alarm and Timer mode cannot be set at the same time. Non Transfer: Image Transfer feature is not in use. Alarm mode: The alarm trigger activates transferring the image. Refer to page 74. Timer mode: The timer trigger activates transferring the image. Refer to page 80.
Operating Instructions [For assistance, please call: 1-800-272-7033] 73 Non Transfer mode Non Transfer mode enables [Start Capture] on the operation bar to buffer the image on the Single Camera screen. Refer to page 51. Capture Control can lock [Start Capture] on the operation bar to prevent the user from capturing the Buffered Image. Click [Clear Buffered images] to clear the buffered image. [Clear Buffered images] does not save the parameters. 1.Click [Image Transfer] on Setup Page. 2.Select the each parameter. Click [Save] when finished. •Click [Cancel] to quit the current settings. The window returns to Setup Page without saving the parameters.
Operating Instructions 74 Transfer in the Alarm Mode The Alarm mode can transfer an image via e-mail or FTP when the alarm trigger is active. To activate the alarm trigger, the External Sensor Input of External I/O must be connected with the external sensors/devices. The Alarm mode can send the e-mail without transferring the image. The Alarm mode uses the Network Camera internal clock. Make sure Date and Time has been configured. Refer to page 64 about Date and Time. 1.Click [Alarm] on Image Transfer window. c. b. a. d. e. f.
Operating Instructions [For assistance, please call: 1-800-272-7033] 75 Instructions for the data fields a.External Sensor Input of External I/O activates the alarm trigger. Refer to page 103. b.Active Time of Trigger The active trigger time can be set in the primary time and the secondary time. The secondary time is the supplement of the primary time. Always: always activates the alarm trigger. Operational between: Sets the start and stop time of the primary time. The day of the week can be set by checking. Start and stop time is set only in 24 h time mode. Alarm enable condition: Select the [Rising] (GND to Open High) or [Falling] (Open High to GND) of External Sensor Input of the External I/O. c.Secondary time is active trigger time except the primary time. Alarm enable condition: Select the [Rising] (GND to Open High) or [Falling] (Open High to GND) of External Sensor Input of the External I/O. d.Sets the image resolution and image quality. Image resolution: 640 x 480/320 x 240/160 x 120 Image quality: Favor Clarity/Standard/Favor Motion e.The Pre or Post trigger or both can be set on the Buffered Image. Check the box. f.Image Frequency: Sets the interval to send the image. Maximum number of images per each trigger: Selects the number of buffering frames from numbers 1 to 3000.
Operating Instructions 76 a.Selects Transfer Method. Non Transfer without Memory Over Write: Image buffering will stop when the internal memory is full. Non Transfer with Memory Over Write: Buffered image will overwrite the older image data when the internal memory is full. FTP: Enters the server address* 1 or Host Name*2, Port number (1— 65535), Login ID*2 and password*2 to access the FTP server and upload file name*2 including full path. Time in 24 h mode is attached on the upload file name. Login timing: [Every Time] or [One Time] can be selected. When selecting [Every Time], Network Camera repeats logging in and out with each transfer of one image. When selecting [One Time], Network Camera stays logged in until the transfer of all images is completed. Select [One Time] when transferring many images in short duration time. Over write setting: a. b. c.
Operating Instructions [For assistance, please call: 1-800-272-7033] 77 Selects [Over Write...] to overwrite the transferred image or [Add time...] to save each transferred image. Data transfer method: Use [Passive Mode] normally. If FTP does not work properly, ask your ISP or network administrator about the transferring mode of FTP server. [Passive Mode] or [Active Mode] is available. b.Mail: Sets the SMTP and POP3 server address*1 or Host Name*2, Login ID*2 and Password*2. From (Reply)*3: Enter the e-mail address of [Reply-to]. [To] can be the same address as From (Reply). To * 3: Enter the e-mail address of receiver. Subject & Text *4: Sets the subject and text of the e-mail. Time in 24 h mode is attached on the subject. Notes •Set POP3 server address or Host Name, Login ID and Password if you need POP authentication to send the e-mail. Ask your ISP or administrator. •Network Camera will only operate correctly with SMTP (Simple Mail Transfer Protocol) server. It is not available with Internet- accessed mail servers like Hotmail ® or other mail accounts accessed via web browser. c.Select [No Message] or [Mail] Mail: Only the notification e-mail is sent when the alarm trigger is active. Refer to b. Mail for each parameter. * 1 Refer to IP addressing on page 105. *2 Refer to unavailable character set 1 on page 105. *3 Refer to unavailable character set 2 on page 105. *4 Only [] is unavailable in the ASCII character table on page 105 and refer to displayable character set on page 106. 2.Select/Enter the each parameter. Click [Save] when finished. •Click [Cancel] to quit the current settings. The window returns to Setup Page without saving the parameters. •Click [Clear Buffered images] to clear the buffered image. [Clear Buffered images] does not save the parameters.
Operating Instructions 78 Setting Example b.a. c. d. e. f.
Operating Instructions [For assistance, please call: 1-800-272-7033] 79 Setting explanation a.The active time of trigger is set between 9:00 AM to 6:00 PM from Monday to Friday. When the alarm occurs in the setting time, the images are transferred to FTP server, and the notification is sent to the specified user via e- mail. The alarm trigger is on when the sensor signal is changed to the [Rising] (GND to Open High) of External Sensor Input of External I/O. b.The secondary time is set inactive. c.The transferring image size is 160 x 120, and the image quality is standard. d.Enables the Pre-alarm and Post-alarm Image Buffering: Network Camera will transfer Pre-alarm 10 images by one image per minute and Post-alarm 20 images by one image per second when detecting the alarm trigger. e.Setting of FTP server: IP Address — 192.168.0.20 Port No. — 21 Login ID — Panasonic Password — ******** Login timing: Every Time Upload File name — NetworkCamera File name and time stamp is named to the file. (Example: NetworkCamera20030101093000000 .jpg) Underlined numbers are 9 h 30 min 00 s 000 ms on January 1, 2003. Data transfer method — Passive Mode f.SMTP server address — xxx.xxx.com POP3 server address — xxx.xxx.com Login ID — Panasonic Password — ******** Mail is sent to [email protected] from [email protected]. Subject is [Mail Transfer]. Text is [Alarm was generated].
Operating Instructions 80 Transfer in the Timer Mode The timer mode can be activated by entering the active time, the image setting, frequency setting and the transfer method on Image Transfer window. Buffered Image can also be transferred via e-mail or FTP. The timer mode uses the Network Camera internal clock. Make sure Date and Time has been configured. Refer to page 64 about Date and Time. 1.Click [Timer] on Image Transfer window. b. c. d. e. a.