Operating Instructions [For assistance, please call: 1-800-272-7033] 91 3.6.12 Status Status window displays general information about Network Camera. Note When some trouble occurs, the information is useful.
Operating Instructions 92 3.6.13 Restart Restart window restarts Network Camera with the parameters saved. Restarting is required when the network parameters are changed. 1.Click [Restart] on Setup Page. 2.Click [Restart Now!]. •Click [Cancel] to quit. The window returns to Setup Page.
Operating Instructions [For assistance, please call: 1-800-272-7033] 93 3.6.14 Update Firmware Update Firmware window allows the user to install the latest version of the Network Camera internal operating system (Application and Camera firmware). In most cases, this will never be necessary. Changes may be necessary to accommodate new operating systems or new web browsers that are not shown on page 10. In those cases, Update Firmware would be available from the Network Camera Technical Support Site at http://panasonic.co.jp/pcc/en/. Check the current firmware version on Setup Page on page 56. Notes •Do not turn off the power during Update Firmware. If the operation of Update Firmware is stopped, refer to page 123. •Buffered Images are erased when performing Update Firmware. 1.Download the proper firmware from the Network Camera Technical Support Site mentioned above. 2.If Network Camera is accessible from the Internet, temporarily disable access and connect Network Camera to the PC as the following figure. This will eliminate any interruption during the Update Firmware. Note When Network Camera uses the DHCP function, change the Internet connection from DHCP to Static in Network window. Refer to page 60 for the network parameters. 3.Access Setup Page by entering http://IP Address (or URL):Port No./ config.html on the web browser and press [Enter]. •When port number is 80 (default), you do not need to enter port number. Ethernet hub Without Ethernet hub, you should use category 5 cross cable. Broadband Router or orCategory 5 straight cable
Operating Instructions 94 4.Click [Update Firmware] on Setup Page. 5.Click [Update Firmware]. Wait about one minute. Note If you click [Update Firmware], operation cannot be canceled. If canceled, refer to page 123.
Operating Instructions [For assistance, please call: 1-800-272-7033] 95 6.Click [Browse...] to select the firmware from the file selector. •A dialog box appears to choose the file. 7.Select a desired Firmware file for Application or Camera (including the path information) and click [Open]. 8.Make sure the desired firmware file name is selected correctly, and click [Update Firmware]. Restarting window is displayed, and Network Camera restarts automatically. Restart operation takes about one minute. Confirm that the Update Firmware Version number is the latest number on Status window on Setup Page.
Operating Instructions 96 3.6.15 Reset to Factory Default Reset to Factory Default window initializes all the parameters including the ID, Password, IP address and Subnet Mask except Date and Time setting to the factory default. Reconfirm the settings before doing the Reset to Factory Default operation. 1.Click [Reset to Factory Default] on Setup Page. 2.Click [Execute]. •Indicator changes such as Orange blinking twice –> Turning off about 15 seconds. Initializing takes about one minute. •Click [Cancel] to quit. The window returns to Setup Page. Notes •Do not turn off the power during the Reset to Factory Default. It may interrupt the Network Camera operation. •IP address and Subnet Mask should be set again after Resetting to Factory Default. •FACTORY DEFAULT RESET button can also reset Network Camera to the Factory Default. Refer to page 109. •Internal clock will not be reset, however, time mode will return to AM/ PM mode and Auto adjustment will be disabled. •If Reset to Factory Default is used, all user settings will be lost, and you will have to reconfigure the entire Network Camera.
Operating Instructions [For assistance, please call: 1-800-272-7033] 97 Section 4 Technical Guides
Operating Instructions 98 4.1 Mounting Two ways of mounting are shown in the following figures. MAC Address and Serial Number are indicated on the bottom label of the main unit of Network Camera. Record both of them on the Network Camera Memo on page 3. They are indispensable for setting network parameters after mounting Network Camera and for future customer servicing. Note Mounting and cabling instructions described in this Operating Instructions follow generally accepted guidelines suitable for residential installations. In some areas, commercial and industrial installations are regulated by local or state ordinances. For such installations, contact your local building department or building inspector for more details. 4.1.1 Mounting on the Table Mount Network Camera at an even place where vibrations etc. are few. Note Network Camera is available between 15° based on level line for mounting on the ceiling.
Operating Instructions [For assistance, please call: 1-800-272-7033] 99 4.1.2 Mounting on the Ceiling Mount Network Camera at an even place where vibrations etc. are few. Set the Tilt range to [On the ceiling] on Camera Setup window on page 84. Two ways of wiring can be considered; wiring through a hole made in the ceiling or wiring without making a hole for a cable in the ceiling. Select either one of the two. Wiring through a hole made in the ceiling 1.Fix the Ceiling Plate B on the ceiling with Screws B. •Fix the Ceiling Plate B more than 100 mm (4 inches) off the wall or other obstacles from its center. •Make sure Network Camera is firmly mounted on a beam of wood etc. When there is no beam, apply a board on the other side of the ceiling to make sure Network Camera does not drop. Screws B (4 pcs.)Keep more than 100 mm (4 inches) off the wall or other obstacles. Network Camera Direction 100 mm (4 inches)
Operating Instructions 100 2.Make a hole for a cable. 3.Fix the rubbers and dents of Network Camera to the Ceiling Plate A and fix them firmly. •Make sure Network Camera, using coins etc., is firmly fixed. 4.Fix the Ceiling Plate A to the Ceiling Plate B and fix them firmly with Screws A. Note Install Network Camera so that the connecting part comes to the front. Hole for a cable: 25 mm (1 inch) 65 mm (2.5 inches) Fit the four rubbers in place. Fit the two dents in place. Fit the hooks to the holes and move in the counterclockwise direction. Screws A (2 pcs.)Four Tabs Fix firmly with Screws A.