    [For assistance, please call: 1-800-272-7033] 71
    Non Transfer mode
    Non Transfer mode enables[Start Capture]on the operation bar to buffer the
    image on the Single Camera screen. Refer to page 50. Capture Control can lock
    [Start Capture]on the operation bar to prevent the user from capturing the
    Buffered Image. Click[ClearBuffered images]to clear the buffered image.
    [ClearBuffered images]does not save the parameters.
    1.Click[Image Transfer]on Setup Page.
    2.Select the each parameter. Click[Save]when finished.
     Click[Cancel]to quit the current settings. The window returns to Setup
    Page without saving the parameters. 
    						
    							Operating Instructions
    72
    Transfer in the Alarm Mode
    TheAlarmmodecantransferanimageviae-mailorFTPwhenthealarmtrigger
    is active. To activate the alarm trigger, the External Sensor Input of External I/O
    must be connected with the external sensors/devices. The Alarm mode can send
    the e-mail without transferring the image. The Alarm mode uses the Network
    Camera internal clock. Make sure Date and Time has been configured. Refer to
    page 62 about Date and Time.
    1.Click[Alarm]onImage Transfer window.
    c. b. a.
    d.
    e.
    f. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033] 73
    Instructions for the data fields
    a.External Sensor Input of External I/O activates the alarm trigger. Refer
    to page 102.
    b.Active Time of Trigger
    The active trigger time can be set in the primary time and the
    secondary time. The secondary time is the supplement of the primary
    time.
    Always: always activates the alarm trigger.
    Operational between: Sets the start and stop time of the primary time.
    The day of the week can be set by checking. Start and stop time is set
    only in 24 h time mode.
    Alarm enable condition:
    Select the [Rising] (GND to Open High) or [Falling] (Open High to GND)
    of External Sensor Input of the External I/O.
    c.Secondary timeis active trigger time except the primary time.
    Alarm enable condition:
    Select the [Rising] (GND to Open High) or [Falling] (Open High to GND)
    of External Sensor Input of the External I/O.
    d.Sets theimage resolutionandimage quality.
    Image resolution: 640 x 480/320 x 240/160 x 120
    Image quality: Favor Clarity/Standard/Favor Motion
    e.The Pre or Post trigger or both can be set on the Buffered Image. Check
    the box.
    f.Image Frequency: Sets the interval to send the image.
    Maximum number of images per each trigger:
    Selects the number of buffering frames from numbers 1 to 3000. 
    						
    							Operating Instructions
    74
    a.SelectsTransfer Method.
    Non Transfer without Memory Over Write:
    Image buffering will stop when the internal memory is full.
    Non Transfer with Memory Over Write:
    Buffered image will overwrite the older image data when the internal
    memory is full.
    FTP: Enters the server address*
    1or Host Name*2, Port Number (1—
    65535), Login ID*2and password*2to access the FTP server and
    upload file name*2including full path. Time in 24 h mode is attached on
    theuploadfilename.
    Login timing:
    [Every Time] or [One Time] can be selected. When selecting [Every
    Time], Network Camera repeats logging in and out with each transfer
    of one image. When selecting [One Time], Network Camera stays
    logged in until the transfer of all images is completed. Select [One
    Time] when transferring many images in short duration time.
    a.
    b.
    c. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033] 75
    Over write setting:
    Selects [Over Write...] to overwrite the transferred image or [Add
    time...] to save each transferred image.
    Data transfer method:
    Use [Passive Mode] normally. If FTP does not work properly, ask your
    ISP or network administrator about the transferring mode of FTP
    server. [Passive Mode] or [Active Mode] is available.
    b.Mail: Sets the SMTP and POP3 server address*1or Host Name*2,
    Login ID*2and Password*2.
    From (Reply)*3: Enter the e-mail address of [Reply-to]. [To] can be the
    same address as From (Reply).
    To *
    3: Enter the e-mail address of receiver.
    Subject & Text *4: Sets the subject and text of the e-mail.
    Timein24hmodeisattachedonthesubject.
    Notes
     Set POP3 server address or Host Name, Login ID and
    Password if you need POP authentication to send the e-mail.
    Ask your ISP or administrator.
     Network Camera will only operate correctly with SMTP (Simple
    Mail Transfer Protocol) server. It is not available with Internet-
    accessed mail servers like Hotmail
    ® or other mail accounts
    accessed via web browser.
    c.Select [No Message] or [Mail]
    Mail: Only the notification e-mail is sent when the alarm trigger is
    active. Refer tob. Mailfor each parameter.
    *
    1Refer to IP addressing on page 104.
    *2Refer to unavailable character set 1 on page 104.
    *3Refer to unavailable character set 2 on page 104.
    *4Only [] is unavailable in the ASCII character table on page 104 and
    refer to displayable character set on page 105.
    2.Select/Enter the each parameter. Click[Save]when finished.
     Click[Cancel]to quit the current settings. The window returns to Setup
    Page without saving the parameters.
     Click[ClearBuffered images]to clear the buffered image.
    [ClearBuffered images]does not save the parameters. 
    						
    							Operating Instructions
    76
    Setting Example
    b.a.
    c.
    d.
    e.
    f. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033] 77
    Setting explanation
    a.The active time of trigger is set between 9:00 AM to 6:00 PM from
    Monday to Friday.
    When the alarm occurs in the setting time, the images are transferred
    to FTP server, and the notification is sent to the specified user via e-
    mail.
    The alarm trigger is on when the sensor signal is changed to the
    [Rising] (GND to Open High) of External Sensor Input of External I/O.
    b.The secondary time is set inactive.
    c.The transferring image size is 160 x 120, and the image quality is
    standard.
    d.Enables the Pre-alarm and Post-alarm Image Buffering:
    Network Camera will transfer Pre-alarm 10 images by one image per
    minute and Post-alarm 20 images by one image per second when
    detecting the alarm trigger.
    e.Setting of FTP server:
    IP Address — 192.168.0.20
    Por t No. — 21
    Login ID — Panasonic
    Password — ********
    Login timing: Every Time
    Upload File name — NetworkCamera
    File name and time stamp is named to the file.
    (Example: NetworkCamera20030101093000000
    .jpg)
    Underlined numbers are 9 h 30 min 00 s 000 ms on January 1, 2003.
    Data transfer method — Passive Mode
    f.SMTP server address — xxx.xxx.com
    POP3 server address — xxx.xxx.com
    Login ID — Panasonic
    Password — ********
    Mail is sent to [email protected] from
    [email protected].
    Subject is [Mail Transfer].
    Text is [Alarm was generated]. 
    						
    							Operating Instructions
    78
    Transfer in the Timer Mode
    The timer mode can be activated by entering the active time, the image setting,
    frequency setting and the transfer method onImage Transfer window.Buffered
    Image can also be transferred via e-mail or FTP. The timer mode uses the Network
    Camera internal clock. Make sure Date and Time has been configured. Refer to
    page 62 about Date and Time.
    1.Click[Timer]on Image Transfer window.
    b.
    c.
    d.
    e. a. 
    						
    							Operating Instructions
    [For assistance, please call: 1-800-272-7033] 79
    Instructions for the data fields
    a.Buffers or transfers by the timer trigger.
    b.Active Time of Trigger
    Always: always activates the timer trigger. The timer trigger interval
    can be set ine. ImageBuffer Frequency Setting.
    Operational between: Sets the start and stop time of the primary time.
    The day of the week can be set by checking. If the setting time passes
    over midnight, check the check box of only the day of start time. Start
    and stop time is set only in 24 h time mode.
    Note
    The first image is buffered or transferred at the start time. The later
    images are buffered or transferred at the interval of thee. ImageBuffer
    Frequency Setting.
    c.Secondary timeis active except the primary time.
    The timer trigger interval in the secondary time can be set ine. Image
    Buffer Frequency Setting.
    d.Sets theimage resolutionandimage quality.
    Image resolution: 640 x 480/320 x 240/160 x 120
    Image quality: Favor Clarity/Standard/Favor Motion
    e.Image Frequency: Sets the interval to send the image.
    Note
    Short interval of Image Buffer Frequency makes Network Camera
    transfer the older images. Set the interval long enough to transfer the
    images. Buffered Image screen enables you to check this setting. 
    						
    							Operating Instructions
    80
    a.SelectsTransfer Method.
    Non Transfer without Memory Over Write:
    Image buffering will stop when the internal memory is full.
    Non Transfer with Memory Over Write:
    Buffered image will overwrite the older image data when the internal
    memory is full.
    [Primary]or[Secondary]on the operation bar can be displayed to
    view the Buffered Image screen in Non Transfer setting.
    FTP: Enters the server address*
    1or Host Name*2, Port Number (1—
    65535), Login ID*2and password*2to access the FTP server and
    upload file name*2including full path. Time in 24 h mode is attached on
    theuploadfilename.
    Login timing:
    [Every Time] or [One Time] can be selected. When selecting [Every
    Time], Network Camera repeats logging in and out with each transfer
    of one image. When selecting [One Time], Network Camera stays
    logged in until the transfer of all images is completed. Select [One
    Time] when transferring many images in short duration time.
    a.
    b. 
    						