Panasonic Network Camera Bl C30a Operating Instructions
Have a look at the manual Panasonic Network Camera Bl C30a Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Operating Instructions [For assistance, please call: 1-800-272-7033] 91 Wireless Communication mode 802.11b/g - - (Channel) Auto - - SSID BLC30AXXX X-Up to 32 characters, signs or numbers (Speed) Auto - - Encryption (WEP) No encryption-- Authentication Open System - - WEPKey 1—4 ASCII 13 Characters 128 bit-- UPnP Auto Port Forwarding Disable - - Display Shortcut Icon in My Network PlacesEnable - - Viewnet cam.comEnable No check - - Date and TimeTime Setting AM/PM - - Automatic Time AdjustmentNo check When using NTP- Time Zone GMT -05:00 - - Adjust Clock for Daylight Saving TimeNo check - - Start Day Apr, First Sunday, 2 AM-- End Day Oct, Last Sunday, 2 AM-- Items Default Required Notes
Operating Instructions 92 Camera Camera Name Network CameraRequired 1—15 characters *6 White Balance Auto - Auto/Fixed Indoor/ Fixed Fluorescent (White)/Fixed Fluorescent (Daylight)/Fixed Outdoor/Hold AC Power Source Frequency60 Hz - 50 Hz, 60 Hz Pan Range (Minimum) -50 degrees - -50—+50 degrees (Home Position) 0 degrees - -50—+50 degrees (Maximum) +50 degrees - -50—+50 degrees Tilt Range (Minimum) -40 degrees - -40—+10 degrees (Home Position) 0 degrees - -40—+10 degrees (Maximum) +10 degrees - -40—+10 degreesItems Default Required Notes
Operating Instructions [For assistance, please call: 1-800-272-7033] 93 Account Items Default Required Notes Security: AdministratorGeneral AuthenticationDo not permit access from guest users -- User Name [Blank] When setting administrator6—15 characters *3 Password [Blank] When setting administrator6—15 characters *3 Retype Password[Blank] When setting administrator6—15 characters *3 General User User ID List [Blank] - - User Name [Blank] When setting general user6—15 characters *3 Password [Blank] When setting general user6—15 characters *3 Retype Password[Blank] When setting general user6—15 characters *3 Access Level Level 3 - -
Operating Instructions 94 Advanced Items Default Required Notes Image DisplaySingle Camera Image Resolution320 x 240 - 320 x 240 or 640 x 480 Single Camera Image QualityStandard - Favor Clarity, Standard or Favo r Mo ti o n Single Camera Refresh IntervalMotion - 3, 5, 10, 30, 60 (s) or Motion Multi-Camera Image Resolution320 x 240 - 160 x 120 or 320 x 240 Multi-Camera Image QualityStandard - Favor Clarity, Standard or Favo r Mo ti o n Multi-Camera Refresh IntervalMotion When reducing traffic3, 5, 10, 30, 60 (s) or Motion Limit Continuous Motion JPEGUnlimited When reducing traffic10, 30 (s), 1, 5, 10, 30, 60 (min) or Unlimited Still Image Refresh Interval30 s - 3, 5, 10, 30 or 60 (s) Language English - English/ Japanese/ French/German/ Italian/Spanish/ Simplified Chinese/Russian
Operating Instructions [For assistance, please call: 1-800-272-7033] 95 Multi- CameraMulti-Camera [Blank] - - Display Checked When setting Multi-Camera- IP Address or Host Name[Blank] When setting Multi-CameraIP address*1 Host name*5 is 1—255 characters. Port No. [Blank] When setting Multi-Camera20, 21, 25 and 110 are not available. *2 Camera Name [Blank] When setting Multi-Camera1—15 characters *7 Change Camera OrderFrom No.1 to No.1When changing camera orderFr o m No.1 — 1 2 to No.1—12 Items Default Required Notes
Operating Instructions 96 Buffer/ TransferStatus Off - - Trigger Timer - Timer, Sensor Active Time of Trigger Always - - Lens Position When Tr i g g e r e dDo not move - Do not move, Move to sensor position Image Resolution 320 x 240 - 160 x 120, 320 x 240, 640 x 480 Image Quality Standard - Favor Clarity, Standard, Favor Mo t i on Image Buffer FrequencyEvery 1 s, buffer 1 image- Every 1 (s/min/ h), buffer 1—15 images Non detection time No appointmentWhen selecting sensorNo appointment, 10, 30 (s), 1, 3, 5, 10 (min) Transfer Method No Transfer, No Memory Overwrite-- Notify - - - Operation TimeOperation Time Always - - Indicator ControlIndicator Control Turn indicator on when camera is on-- Privacy ModePrivacy Button Checked - - Privacy Mode Disable - -Items Default Required Notes
Operating Instructions [For assistance, please call: 1-800-272-7033] 97 Preset Buttons Items Default Required Notes Preset ButtonsPreset 1 UpperLeft - - Preset 2 UpperRight - - Preset 3 LowerLeft - - Preset 4 LowerRight - - *1 Set 4 digits (0—255) and 3 periods such as 192.168.0.253. But 0.0.0.0 and 255.255.255.255 are not available. *2 Set the number of 1—65535. *3 Enter ASCII characters for the host name (see page 107). But [Space], [], [], [&], [] and [:] are not available. *4 Enter ASCII characters for the host name (see page 107). But [Space], [], [], [&], [] are not available. *5 Enter ASCII characters for the host name (see page 107). But [Space], [], [], [#], [&], [%], [=], [+], [?], [] are not available. *6 Enter ASCII characters (see page 107) or characters in each language (1—15 characters for a 1-byte character and 1—7 characters for a 2-byte character). But [Space], [], [], [&], [] are not available. *7 Enter ASCII characters (see page 107) or characters in each language (1—15 characters for a 1-byte character and 1—7 characters for a 2-byte character). But [Space], [], [], [#], [&], [%], [=], [+], [?], [] are not available.
Operating Instructions 98 3.5 Cleaning Clean the camera after the camera is turned off. 3.5.1 Cleaning the Main Unit Clean the unit with a dry and soft cloth. Notes Do not use alcohol, polishing powder, cleanser, benzine, thinner, wax, petroleum products or hot water to wipe the camera. Also avoid pesticide, glass cleaner or hair spray. They may cause change in the shape or color. Do not apply pressure to the pan/tilt portion of the camera. Any forced movement can damage the internal mechanism. If the pyroelectric infrared sensor has dust on it, it may not detect temperature differences. Keep the pyroelectric infrared sensor clean. 3.5.2 Cleaning the Lens If the lens has dust on it, the image may be unclear or out of focus. Note Do not touch the lens directly. Fingerprints may cause an unclear image.
Operating Instructions [For assistance, please call: 1-800-272-7033] 99 3.6 Setting an IP Address on Your PC Your PCs IP address can be assigned by the following procedures. 1.Display the TCP/IP Properties window. The steps are different depending on your OS. The steps are shown below. When using Windows XP and Windows 2000, log in as an administrator to access the TCP/IP Properties window. 2.Enter IP address and subnet mask. 3.Click [OK]. In Windows Me or Windows 98SE, the PC needs to be restarted to enable the settings. Local IP Address Local IP address is the network ID that is not used on the Internet. They are classified into Class A, Class B and Class C, as shown below. Set the IP address in the range of the number specified in the class corresponding to your local network scale.OS Steps Windows XP [Start] ( [Settings]) [Control Panel] [Network and Internet Connections] [Network Connections] [Local Area Connection] in use [Properties] Select Internet Protocol [TCP/IP] [Properties] [Use the following IP address] Windows 2000 [Start] [Settings] [Control Panel] [Network and Dial-up Connections] [Local Area Connection] in use [Properties] Select Internet Protocol [TCP/IP] [Properties] [Use the following IP address] Windows Me, Windows 98SE[Start] [Settings] [Control Panel] [Network] Select [TCP/IP] with adaptor in use [Properties] [IP Address] [Specify an IP address] Class Subnet Mask Local IP Address Class A 255. 0. 0. 0 10. 0. 0. 1 — 10. 255. 255. 254 Class B 255. 255. 0. 0 172. 16. 0. 1 — 172. 31. 255. 254 Class C 255. 255. 255. 0 192. 168. 0. 1 — 192. 168. 0. 254
Operating Instructions 100 3.7 Using Setup Program The Setup Program can be used for the following purposes. Finding the IP address and port number of the camera connected to your network. Setting up the camera automatically. Setting up the camera manually to a Static or a DHCP setting. Displaying the Setup page. Finding the camera 1. Connect the Ethernet cable to the camera following the Getting Started. If the Network Camera Setup window does not appear, click setup.exe on the Setup CD-ROM. 2.Insert the Setup CD-ROM into the CD-ROM drive of your PC. If the Network Camera Setup window does not appear, click setup.exe on the Setup CD-ROM. 3.Click [Camera Setup]. You can find the camera IP address and port number by looking up the MAC address of your camera.Displays version information about this program. Sets up the camera. Displays the camera manuals. If your PC does not have Adobe ® Acrobat® Reader, install it from the Adobe Reader website. Closes the Setup Program. Camera Status Camera List window Por t No. MAC Address IP Address