Panasonic Network Camera Bb Hcm403a Operating Instructions
Have a look at the manual Panasonic Network Camera Bb Hcm403a Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Operating Instructions 71 Setting Description Camera Name The camera name is displayed on the Single Camera page. Enter ASCII characters (see page 176) or characters from other languages (1—15 characters for a 1-byte character and 1—7 characters for a 2-byte character). Note that [Space], [], [], [&], [] are not available. White Balance Select from the following options. K (Kelvin) is a unit for color temperature. Auto (default) — Automatic adjustment Fixed Indoor — Electric bulb (2800 K) Fixed Fluorescent (White)— White type fluorescent light (3600 K) Fixed Fluorescent (Daylight)— Daylight type fluorescent light (4000 K) Fixed Outdoor — Solar light (6000 K) Hold — Setting [Hold] keeps the current white balance. Note White balance settings are also saved when registering the home position. Color Night View In the color night view mode, the camera image becomes brighter in a low illuminance. The camera image returns to normal operation in a bright location. In color night view mode, the following may be experienced: – Image refresh interval may increase (1 frame a second at maximum). – Images may blur when viewing moving objects or tilting in low illuminance. Note In the color night view mode, the image may have white or colored dots around the object. This is not a problem, since it is a CCD sensor characteristic.
Operating Instructions 72 3.Click [Save] when finished. The new settings are saved. When finished, Success! is displayed. 4.Click [Go to Camera page]. The Camera page is displayed.
Operating Instructions 73 2.11 Adjusting Audio The Audio page allows you to set the microphone, the external speaker, microphone sensitivity and external speaker volume settings. 1.Click [Audio] on the Setup page. 2.Set each parameter. Clicking [Cancel] cancels your settings without saving changes. Setting Description Output You can control audio output for the external speaker connected to the camera. Volume You can control the external speaker output volume. PC Audio Input Timeout You can set the time to consecutively perceive the audio from your PC. (1 [default]—60 minutes) Input You can control audio input from the external microphone connected to the camera. Camera Microphone Sensitivity You can select the microphone sensitivity level. Minimum: Decreased sensitivity Standard: Standard setting (default) Maximum: Enhanced sensitivity
Operating Instructions 74 3.Click [Save] when finished. The new settings are saved. When finished, Success! is displayed. 4.Click [Go to Audio page]. The Audio page is displayed.
Operating Instructions 75 3 Registering Users 3.1 Changing the Authentication Setting and Administrator User Name and Password The Security: Administrator page allows you to change authentication, and the administrators user name and password. An authentication window allows registered users to access the camera. Note If you access the camera for the first time, the window for setting the administrators user name and password is displayed. Make a note of the user name and password so that you will not forget them. The user name and password should be secured at your own responsibility. Pay attention to the following points. – Set a user name and password with as many characters as possible. – Change the password regularly. Setting [Permit access from guest users] (permitting access without a User Name or Password) or [Permit access from guest users (mobile only)] (permitting access without a User Name or Password) at General Authentication risks the images being viewed by third parties. Control the contents of the images accordingly. IMPORTANT It is important to limit access to the camera by use of a unique User Name and a secret Password. Because the camera is accessed through the Internet it is possible that the camera could be accessed by unknown individuals, including those who are commonly known as hackers, to whom you do not want to allow access. The use of a unique User Name and a Password known only to you will help insure that only authorized individuals are given access to the camera. You have the option of proceeding without a User Name and Password, but it is strongly recommended that you utilize these protections.
Operating Instructions 76 1.Click [Administrator] on the Setup page. 2.Set each parameter. Clicking [Cancel] cancels your settings without saving changes. Setting Description General AuthenticationAuthentication has 3 phases. If you set [Permit access from guest users], the camera does not display the authentication window in camera access. All guest users can view images without a user name and password. If you set [Permit access from guest users (mobile only)], an authentication window is not displayed when accessing the cell phone page. All guest users can view images without a user name and password when accessing the cell phone page. Note If you set [Permit access from guest users], [Login] is displayed at the top of the page. After you log in as an administrator (see page 79), the Setup page and the Maintenance page can be accessed. If you set [Do not permit access from guest users], an authentication window is displayed to access the camera. Users must enter the user name and password.
Operating Instructions 77 Note When setting authentication, set the user name and password, and save them. When users other than an administrator are accessing the camera, the [Setup] and [Maintenance] tabs will not be displayed. The user name and password are case sensitive. 3.Click [Save] when finished. The new settings are saved. When finished, Success! is displayed. 4.Click [Go to Security: Administrator page]. The Security: Administrator page is displayed. Note When the user name and password have been changed, the camera displays an authentication window. Enter the user name and password, and click [OK]. User Name/ Password User Name (6 to 15 characters): Enter the user name. Password (6 to 15 characters): Enter the password. Note The password must be different from the user name. Retype Password: Reenter the password. Enter ASCII characters (see page 176). Note that [Space], [], [], [&], [] and [:] are not available. Setting Description
Operating Instructions 78 Administrator/General Users/Guest Users The access level to the camera is divided to administrator, general users and guest users. Note Guest users mean unregistered users. Set [Permit access from guest users] or [Permit access from guest users (mobile only)] on the Security: Administrator page (see page 75) to allow access from guest users. Items Administrator General UsersGuest Users Guest Users (mobile only) User Name and PasswordRequired Required Not Required Not Required Number of Users150—— Accessible PagesAll Pages Pages Except For Setup and Maintenance pagePages Except For Setup and Maintenance pageCell phone page only Access Level All Operations Access level can be set for each general user (see page 80).Access level can be set for guest users (see page 80).—
Operating Instructions 79 3.2 Logging in to the Camera If you set [Permit access from guest users] on the Security: Administrator page, [Login] is displayed at the top of the page. After you log in as an administrator, the Setup page and the Maintenance page can be accessed. 1.Click [Login] at the top of the page. 2.Check a login mode, and click [Login]. Note The authentication window is displayed. Enter the user name and password set for General Users or Administrator. 3.Enter a valid user name and password according to the Login mode selected in step 2, and click [OK] to log in to the camera.
Operating Instructions 80 3.3 Creating, Modifying or Deleting General Users The General User page allows you to create, modify or delete general users. Up to 50 general users can be registered. The access level is set for each general user. If you set [Permit access from guest users] or [Permit access from guest users (mobile only)] on the Security: Administrator page, the access level can be set for guest users. Note For general users, the Setup and Maintenance tabs are not displayed. 1.Click [General Users] on the Setup page. 2.To create a general user, click [Create]. When setting [Do not permit access from guest users] When setting [Permit access from guest users] or [Permit access from guest users (mobile only)] To change the settings of general users or guest users, select their name and click [Modify]. The modification page is displayed. To delete a general user, select the name and click [Delete]. The confirmation page is displayed.