Operating Instructions [For assistance, please call: 1-800-272-7033] 111 3.1.4 Creating Configuration File A configuration file can be saved on your PC. You can load the camera settings from the configuration file on the Load Settings page (see page 112). Note The saved image has privacy information. Prevent private information leaks. 1.Click [Save Settings] on the Maintenance page. 2.Click [Save]. 3.Click [Save] on the File Download dialog box. 4.Specify the location, and click [Save] on the Save As dialog box. • The configuration file is saved in the location. Notes • The file extension (.dat) cannot be changed. If you change it, the settings cannot be loaded. • If you try to updating the camera, create a configuration file after updating the firmware. If there is a firmware version difference between the camera that you create a configuration file from and the camera that you try to load settings to, the settings may not be loaded to the camera.
Operating Instructions 11 2 3.1.5 Loading Settings from a Configuration File The settings can be loaded from a configuration file. If you reset the camera to factory default, the camera can load its settings from the configuration file. Notes • The configuration file has network settings. When the settings are loaded, the network settings are also loaded as they were saved. • If there is a firmware version difference between the camera that you create a configuration file from and the camera that you try to load settings to, the settings may not be loaded to the camera. Save settings after updating the firmware. 1.Click [Load Settings] on the Maintenance page. 2.Click [Browse...]. 3.Select the configuration file on the Choose file dialog box, and click [Open]. • The file name is displayed in the data field. 4.Confirm the file name, and click [Load]. 5.Click [Restart]. • The camera restarts, and the Top page is displayed.
Operating Instructions [For assistance, please call: 1-800-272-7033] 113 3.1.6 Resetting the Camera to Factory Default All camera settings are reset to factory default directly after the Execute button is clicked. 1.Click [Reset to Factory Default] on the Maintenance page. 2.Click [Execute]. • The indicator blinks orange, and then turns off for 10 seconds. • All camera settings (user name, password, IP address, subnet mask etc.) are reset to factory default. • If the camera is reset to factory default, the network connection mode changes to [Automatic Setup]. Reconfigure the camera seeing the Getting Started. Notes • The internal clock will not be reset, but the time format will return to AM/ PM mode (see page 60). Set it again. • See page 119—page 126 for default settings. • Pressing the FACTORY DEFAULT RESET button resets the camera to the factory default (see page 118). • All buffered images on the internal memory are deleted when resetting the camera to factory default. The buffered images on the SD memory card are not deleted. • The reset operation takes about 1 minute. • Do not turn off the camera during the reset operation.
Operating Instructions 11 4 3.2Support page 3.2.1 Seeing Help page The Help page displays explanations for each feature about the following 1. to 6. items. Clicking [Help] on the Support page displays the next page. 3.2.2 Seeing Product Information You can see product information on the Panasonic Network Camera support website. Clicking [Product Information] on the Support page displays the URL, click it. Note If the camera is not connected to the Internet, the website cannot be displayed. Support (20) HelpDisplays the Help page (see page 114). (21) Product InformationDisplays product information website (see page 114). (22) Support InformationDisplays support information website (see page 115). (20) (21) (22)
Operating Instructions [For assistance, please call: 1-800-272-7033] 115 3.2.3 Seeing Support Information You can see support information on the Panasonic Network Camera support website. Clicking [Support Information] on the Support page displays the URL, click it. Note If the camera is not connected to the Internet, the website cannot be displayed.
Operating Instructions 11 6 3.3 External I/O If you connect the external devices such as sensors to the External I/O and image buffer/transfer by alarm signal is set, the camera image is transferred by the alarm detection. Explanation of the External I/O Note The External I/O (Input/Output) are independent. Output terminal is controlled only by External Output Control page on page 104. Pin Features G • GND pin 1 External Sensor Input 1 • Use it by opening or GND short-circuit. G • GND pin 2 External Sensor Input 2 • Use it by opening or GND short-circuit. 3 External Device Control Output • You can control it on the External Output page (see page 104). • It is an open collector circuit, and the maximum drawing-in current is the same as pin 4. Do not exceed the voltage of DC power output terminal (pin 4). 4 DC Power Output Terminal • 10.5—13.5 V DC • Maximum of 100 mA load drive is possible.
Operating Instructions [For assistance, please call: 1-800-272-7033] 117 Circuit Diagram Example CAUTION •The external I/O is not capable of connecting directly to devices that require large amounts of current. In some case, a custom interface circuit (customer-provided) may have to be used. Serious damage to the camera may result if a device is connected to the external I/O that exceeds its electrical capability (see page 116). •The low voltage/current circuits and high voltage/current circuits are in the camera circuit. The qualified electrician should do the wiring not by yourself. Incorrect wiring could damage the camera. You could receive the fatal electric shock. Light Door Sensor 1 (Alarm 1) Door Sensor 2 (Alarm 2)Relay Camera 12 V 2 3 4 G 1 G DC10.5 V–13 V
Operating Instructions 11 8 3.4 FACTORY DEFAULT RESET Button The camera has a FACTORY DEFAULT RESET button on the side. Pressing the FACTORY DEFAULT RESET button resets the camera to factory default. If you lose your user name and password, use this button to reset the camera. • Press the FACTORY DEFAULT RESET button for 1 second when the camera is on. • The indicator blinks orange, and then turns off for 5 seconds. • Do not turn off the camera until the indicator lights green. Notes • The internal clock will not be reset, but the time format will return to AM/ PM mode (see page 60). Set it again. • See page 119—page 126 for default settings. • All buffered images on the internal memory are deleted when resetting the camera to factory default. The buffered images on the SD memory card are not deleted. • The reset operation takes about 1 minute. FACTORY DEFAULT RESET Button (Press the button with a pointed object.)
Operating Instructions [For assistance, please call: 1-800-272-7033] 119 3.5 Default Setting List Basic Items Default Required Notes Network (IPv4)Connection Mode Automatic Setup- Automatic Setup/ Static/DHCP Allow Access from the Internet (Automatic Setup only)No - - Network Configuration from Setup Program (Static/DHCP only)Enable - - Port No. (Static/DHCP only)80 - 20, 21, 25 and 110 is not available. IP address (Static only)192.168.0. 253When setting Static*1 Subnet Mask (Static only)255.255. 255.0When setting Static*1 Host Name (DHCP only)[Blank] When setting DHCP (Not always required)0—63 characters *4 Default Gateway (Static/DHCP only)[Blank] When using Gateway*1 DNS Server 1 DNS Server 2 (Static/DHCP only)[Blank] When using DNS*1 Max. Bandwidth Usage (Mbps)Unlimited - 0.1, 0.2, 0.3, 0.5, 1 or Unlimited Connection Type Auto Negotiation--
Operating Instructions 120 Network (IPv6)Connection Mode Automatic Setup- Automatic Setup/ Static Allow Access from the Internet (Automatic Setup only)No - - Port No. (Static only)80 - 20, 21, 25 and 110 is not available. IP address (Static only)[Blank] When setting Static*1 Default Gateway (Static only)[Blank] When using Gateway*1 DNS Server 1 DNS Server 2[Blank] When using DNS*1 Max. Bandwidth Usage (Mbps)Unlimited - 0.1, 0.2, 0.3, 0.5, 1 or Unlimited Connection Type Auto Negotiation-- IPsec Use No check - - Encoding strengthStandard (AES, 3DES, DES, NULL )- Standard/High Transport [Blank] - - Tunnel [Blank] - - UPnP Auto Port Forwarding Disable - - Display Shortcut Icon in My Network PlacesEnable - - Viewnet cam.comEnable No check - -Items Default Required Notes