Home
>
Panasonic
>
Air Conditioner
>
Panasonic Mva Series Air Handling Unit 035 000039 001 Installation Operation And Maintenance Manual
Panasonic Mva Series Air Handling Unit 035 000039 001 Installation Operation And Maintenance Manual
Here you can view all the pages of manual Panasonic Mva Series Air Handling Unit 035 000039 001 Installation Operation And Maintenance Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 12
035-000039-001 Page 12 of 38 MVA IOM 1.0 4-25-2014 INSTALLATION—SERVICE CLEARANCES- SIDE RETURN FILTER DETAILS
Page 13
035-000039-001 Page 13 of 38 MVA IOM 1.0 4-25-2014 Install the unit so that it is level or pitches slightly –(1/8 inch) – toward the condensate drain connection. Anchor the unit to the plenum or platform through the bottom flange using 2ea #10 sheet metal screws on each side (4 screws total). Ceiling Suspension: Mount the unit in ceiling- suspended horizontal orientation per suspen- sion details (Figure 4). Unit is NOT intended to be wall mounted. Consult a qualified struc- tural engineer for special...
Page 15
035-000039-001 Page 15 of 38 MVA IOM 1.0 4-25-2014 INSTALLATION CAUTION Direct-expansion coils are shipped pressurized with dry nitrogen. Release pressure from the coil through valves in protective caps before remov- ing caps. Do not leave piping open to the atmosphere un- necessarily. Water and water vapor are detri- mental to the refrigerant system. Until the piping is complete, recap the system and charge with nitrogen at the end of each workday. Clean all piping connections before soldering joints....
Page 16
035-000039-001 Page 16 of 38 MVA IOM 1.0 4-25-2014 INSTALLATIONDANGER WARNING:Hazardous voltage.Only qualified personnel must install the electrical service. Dis- connect and Lock Out all incoming power sources before connecting to electrical service. Install Procedure: To install the electric heater, 1. Disconnect and lock out electrical power from the unit. Remove heater access panel. Discon- nect field power wires from the unit power wires. DANGER! - MAKE SURE there is no voltage supply to the unit...
Page 17
035-000039-001 Page 17 of 38 MVA IOM 1.0 4-25-2014 Typical wiring diagrams are shown on the following pages FOR REFERENCE. Always refer to the wir- ing diagram on the air handling unit for actual wir- ing. NOTE: CHECK MOTOR RATING PLATE FOR CORRECT LINE VOLTAGE. Connect electrical service to unit. Refer to unit wir- ing diagram. Power Wiring For power supply connection, route field power wir- ing L1 and L2 and connect either: 1. Unit W ithout EH: to field-provided and installed disconnect switch and from...
Page 18
035-000039-001 Page 18 of 38 MVA IOM 1.0 4-25-2014 DANGER WARNING:Hazardous voltage.Only qualified personnel must install the electrical service. Dis- connect and Lock Out all incoming power sources before connecting to electrical service. WARNING:This appliance must be permanently grounded in accordance with the National Electrical Code and local code requirements. WARNING: For use with copper conductors only. INSTALLATION-ELECTRICAL General Provide strain relief where field wiring passes through...
Page 19
035-000039-001 Page 19 of 38 MVA IOM 1.0 4-25-2014 INSTALLATION-ELECTRICAL Figure 11 Inter-Unit Control Wiring Do not install the inter-unit control wiring in a way that forms a loop. Figure 12 Inter-Unit Control Wiring Do not install inter-unit control wiring with splic- es or “star branch” pattern. Star branch wiring causes misaddress setting errors. If branching the inter-unit control wiring, the number of branch points should be 16 or fewer. (Branches less than 3.3 ft. are not included in the total...
Page 20
035-000039-001 Page 20 of 38 MVA IOM 1.0 4-25-2014 INSTALLATION-ELECTRICAL (cont’d) TYPICAL WIRING DIAGRAM— Unit sizes 18 & 24 TYPICAL WIRING—MVA18, MVA24