Home > Panasonic > Recording Equipment > Panasonic Matrix Switcher Wj Sx650 Operating Instructions

Panasonic Matrix Switcher Wj Sx650 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Matrix Switcher Wj Sx650 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							81
    Function
    
    Stop manual recording[REC STOP]
    (Press for 2 seconds or
    more.)[SHIFT] + [STOP] Start manual recording [REC] [ZOOM WIDE] + 
    [ZOOM TELE]WV-CU950/650:
    When a camera is selected,
    manual recording is started
    for the recorder connected to
    the camera.
    Displays the search list. [SEARCH]
    →Open Search Mode
    menu.[INDEX]WV-CU950/650, WV-
    CU360C/CJ:
    • Every pressing this button
    can change search list dis-
    play. 
    • Refer to p. 73 Operation list
    of WV-CU950/650 and WV-
    CU360C/CJ for how to oper-
    ate the search list display. 
    Moves the zoomed area. Joystick CDABJoystick CDAB • 4 segments [0] →[MULTI SCREEN] [0] →[SHIFT] + [MULTI
    SCREEN SEL]
    • 7 segments  [1] →[MULTI SCREEN] [1] →[SHIFT] + [MULTI
    SCREEN SEL]
    • 9 segments  [2] →[MULTI SCREEN] [2] →[SHIFT] + [MULTI
    SCREEN SEL]
    • 10 segments  [3] →[MULTI SCREEN] [3] →[SHIFT] + [MULTI
    SCREEN SEL]
    • 13 segments  [4] →[MULTI SCREEN] [4] →[SHIFT] + [MULTI
    SCREEN SEL]
    • 16 segments  [5] →[MULTI SCREEN] [5] →[SHIFT] + [MULTI
    SCREEN SEL]
    Electronic zoom [EL-ZOOM] [SHIFT] + [EL-ZOOM]WV-CU950/650, WV-
    CU360C/CJ:
    Every pressing this button (or
    these buttons) can change
    the zooming rate.
    2x →4x →1x →2x...
    Sequential display ON [TOUR SEQ] [SHIFT] + [SEQUENCE]WV-CU950/650, WV-
    CU360C/CJ:
    Activates a sequence associ-
    ated with the recorder.
    Note:To stop the sequence,
    perform sequence stop.
    Refer to p. 74. Recorder On-screen display
    (OSD) ON/OFF[OSD] Not availableWV-CU950/650:
    Every pressing the button can
    display or hide all the information.
    Multiscreen displayWV-CU950/650, WV-
    CU360C/CJ:
    • Without numeric entry,
    (Without specifying the seg-
    ment pattern,) every press-
    ing [[MULTI SCREEN] (or
    [SHIFT] + [MULTI SCREEN
    SEL]) can change multi-
    screen segment patterns.
    4 segments (1 – 4) →
    4 segments (5 – 8) →
    4 segments (9 – 12) →
    4 segments (13 – 16) →
    7 segments →
    9 segments (1 – 9) →
    9 segments (10 – 16) →
    10 segments →
    13 segments →
    16 segments →
    4 segments (1 – 4)...
    • When a camera is selected,
    the multiscreen segment of
    the recorder connected to
    the camera is displayed.
    (You cannot specify the
    segment pattern.)
    WV-CU950/650 WV-CU360C/CJ Note 
    						
    							82
    Playback [PLAY/PAUSE] [PLAY]
    
    • Pause playback [PLAY/PAUSE] [PAUSE]WV-CU950/650, WV-
    CU360C/CJ:
    When a camera is selected,
    the recorded image of cam-
    era is played back.
    WV-CU950/650, WV-
    CU360C/CJ:
    During playback, the record-
    ed images of cameras are
    interchangeably displayed
    by:
    • Camera selection
    • Selects the next/previous
    camera.
    • Fast-forward Shuttle ring clockwise• [FF]
    • Joystick B
    • Fast-reverse Shuttle ring counterclockwise• [REW]
    • Joystick A
    • Skips to the next frame. JogDial clockwise (During
    pause)Joystick B(During pause)
    • Skips to the previous frame. JogDial counterclockwise
    (During pause)Joystick A(During pause)
    • Skips to the next record. JogDial clockwise (During
    playback)Joystick C
    (During playback)
    • Skips to the previous
    record.JogDial counterclockwise
    (During playback)Joystick D
    (During playback)
    • Play the latest recorded
    image.[GO TO LAST] Not available
    • Stops playback.
    • Marking[STOP]
    [MARK][STOP]
    Not availableWV-CU950/650:
    • When a camera is selected,
    the latest recorded image of
    camera is played back.
    • For WJ-HD300 Series, this
    operation is available only
    during playback. • Text information display ON [F3] Not Available
    • Displays the DATA COPY
    window.[F4] Not AvailableWV-CU950/650:
    Refer to p. 73 Operation list of
    WV-CU950/650 and WV-
    CU360C/CJ for how to oper-
    ate the DATA COPY window. 
    • List/Thumbnail Switching [F1] [F1]WV-CU950/650, WV-
    CU360C/CJ:
    Every pressing this button
    can change the search list
    between the list window and
    thumbnail window. Function WV-CU950/650 WV-CU360C/CJ Note 
    						
    							–
    • Multiscreen display
    • Sequential display ON
    • Electronic zoom Refer to p. 81 Electronic
    zoom.WV-CU360C/CJ
    83
    Monitor 1 control [RECORDER] + Not availableWV-CU950/650:
    • Hold down this button until
    the operation end.
    • These operations are not
    available if the recorder
    image cannot be inter-
    changeably displayed on
    Monitor 1 (Example: While
    the SETUP MENU of
    recorder is displayed) • Camera selection Refer to p. 74 Camera selec-
    tion.–
    • Selects the next camera. Refer to p. 74 Selects the next
    camera.–
    • Selects the previous cam-
    era.Refer to p. 74 Selects the pre-
    vious camera.–
    • Recorder On-screen display
    (OSD) ON/OFF
    Refer to p. 81 Recorder On-
    screen display (OSD) ON/OFF.–
    Refer to p. 81 Multiscreen dis-
    play.–
    Refer to p. 81 Sequential dis-
    play ON.– A – B repeat playback Open HD300 A - B Repeat
    menu. →Not available Playback is started when you
    mark the end point.
    • Sets the start point (A) for
    the A - B repeat playback.[F1]–
    • Sets the end point (B) for
    the A - B repeat playback.[F2]–
    • Cancels the A – B repeat
    playback setting.[F4]–
    Filtering Open HD300 Listed menu.
    →Not available
    • ON [F1]–
    • OFF [F2]–
    Function WV-CU950/650 Note 
    						
    							84
    Menu Flow (WV-CU950/650)
    If you press the MENU button without selecting a recorder
    If you select a recorder, and then press the MENU button
    If you select a recorder, and then press the SEARCH button
    : SHIFT + MENU buttons
    :  MENU button Keep pressing the SHIFT button.Keep pressing the SHIFT button.
    If you enter the menu function number, and then 
    press the MENU button, the specified menu will 
    appear.
    : SHIFT + MENU buttons
    : MENU button
    If you enter the menu function number, and then 
    press the MENU button, the specified menu will 
    appear.
    Keep pressing the SHIFT button. 
    						
    							85
    • Recorder control
    When using WV-CU360C/CJ, refer to the operating instruc-
    tions of recorder.
    • Alarm
    Alarm ACK, Alarm Individual Reset, and Alarm Monitor
    Reset are not available. (Alarm All Reset is available.) When
    controlling Alarm History Display from WV-CU360C/CJ, you
    cannot skip to 10 pages forward or backward. (Refer to p.
    76.)
    • Error message display
    When you fail in operations, error messages (Not Avail and
    Prohibited) will not be displayed on the LCD (or LED dis-
    play).
    • Camera control level restriction
    Camera Setup and Preset Position Registration is not
    restricted separately by the user level setting. To restrict
    them, set Camera Control to Disabled. User level setting is
    performed in Operator – Level Table of WJ-SX650 Series
    Administrator Console.
    • Other functions
    You cannot control the following functions by pressing the
    associated buttons on system controllers. Control them by
    entering the system function numbers. (When using WV-
    CU950/650, you can specify the system functions marked
    with * either by pressing the numeric buttons or recalling
    the menu functions on the LCD.)
    1. Enter the system function number by pressing the
    numeric buttons.
    2. Press the SYS FUNC*
    1(or FUNCTION*2) button while
    holding down the SHIFT button.
    *
    1WV-CU950/650
    *2WV-CU360C/CJ
    System function System function number
    Monitor lock ON/OFF* 101
    System status display ON/OFF 102
    Time and date information ON/OFF*104
    Camera information ON/OFF* 105
    Event information ON/OFF* 106
    Monitor status ON/OFF* 107
    All home positions 120
    All auxiliaries OFF 121 This chapter includes notifications on operations from sys-
    tem controllers in the PS·Data mode, a web browser
    accessing the recorder, or a PC.
    PS·Data Mode Operations
    Note:When using a system controller in the PS·Data mode,
    check the software version.
    The available software versions are as follows.
    WV-CU950/650:Ver. 2.00 or later
    WV-CU360C/CJ:Ver. 8.10 or later
    The following is the restrictions of PS·Data mode opera-
    tions. Refer to the operating instructions of system con-
    troller for details.
    • Login
    Log into the system by entering the user ID and password
    registered in the system controller.  After login, you can
    control the unit as a PS·Data operator. PS·Data operator
    setting is performed in Operator – Operator of WJ-SX650
    Series Administrator Console.
    • Logout
    Auto logout is not available. Log out from the system manu-
    ally.
    • Camera selection
    When using WV-CU360C/CJ, you cannot select Camera
    200 or greater.
    • Camera position
    When using WV-CU950/650, camera positions registered in
    the system controller are activated. (Up to 999 camera
    positions are available.) This function is not available with
    WV-CU360C/CJ.
    • Camera selection recall
    Camera selection steps are memorized in the system con-
    troller. (Even when you select another monitor, the memo-
    rized steps are not cleared.) This function is not available
    with WV-CU360C/CJ.
    • Preset
    When using WV-CU360C/CJ, you cannot select Preset
    Position 065 or greater.
    • Recorder selection
    You cannot select a recorder by entering the recorder num-
    ber. To select the recorder, enter the logical camera num-
    ber associated with the camera input channel connected to
    the recorder.
    Operation (Other than Terminal Mode) 
    						
    							86
    Connections of Matrix Switchers (WJ-SX650 Series) and a PS·Data
    System Controller
    By connecting a PS·Data system controller (WV-CU950/650, CONTROLLER NO.: 1) to the DATA ports of the units with Cable
    Kit WV-CA48/10K, you can control these units from the system controller. (Refer to p. 35 for details on connections.)
    Notes:
    •Connect Cable Kit WV-CA48/10K to the DATA 1 port.
    •Set the DATA 1 port of each unit to PSD. Setting changes are performed in System – DATA Port of WJ-SX650 Series
    Administrator Console or DATA PORT (refer to p. 52) of SETUP MENU.
    Connections and Operations
    •When controlling two or more units from a PS·Data system controller, you need to select a unit before operation. To select a
    unit, enter a unit address by pressing the numeric buttons. Then, press the RECORDER/UNIT button while holding down
    the SHIFT button.
    •The unit address setting of each unit must be different from each other. The unit address settings are performed in
    Communication – PS.Data of WJ-SX650 Series Administrator Console.
    •When an alarm occurs to a unit, other units will accept the alarm as a serial alarm input.
    •User level settings for alarm suspension must be the same within all the units.
    •The LCN settings must be different among all the units. (Up to LCN 999 are available.) The LCN settings are performed in
    System – Logical Camera Number of WJ-SX650 Series Administrator Console.
    •When activating AUTO RESET, set the parameter to 3 sec or longer. (Refer to p.49.)
    Controlling from a Web Browser Accessing a Recorder
    If a recorder is connected to the unit, you can control cameras using a web browser of a PC accessing the recorder. You can
    set priority for web browser control. Priority setting is performed in Operator – Operator of WJ-SX650 Series Administrator
    Console.
    Notes: 
    •Refer to the operating instructions of recorder for details on browser control.
    •Regardless of priority setting, during the recorder control from a system controller, camera control is not available from a
    web browser accessing recorders connected to the same DATA port in the daisy chain.
    Controlling from a PC
    You can perform the operations and functions of system controllers by logging into the system and sending RS-232C com-
    mands from a PC connected to the unit. Refer to Serial (RS-232C) Connector Command Reference (PDF file on the supplied
    CD-ROM) for available commands.
    Matrix Switcher WJ-SX 650650Matrix Switcher WJ-SX 650650Matrix Switcher WJ-SX 650650
    AB1324657980
    SYSTEM CONTROLLER
    OPERATEOPERATE LED WILL BLINK
    IF COOLING FAN MALFUNCTIONSOPERATEOPERATE LED WILL BLINK
    IF COOLING FAN MALFUNCTIONS
    Cable Kit
    WV-CA48/10K
    CONTROLLER NO.: 1 Unit Address: 1
    Unit Address: 2Unit Address: 3
    OPERATEOPERATE LED WILL BLINK
    IF COOLING FAN MALFUNCTIONS 
    						
    							87
    Glossary
    This document uses the following terms. 
    Monitor number:Numbers (MON 1 to 32) given to the
    MONITOR OUT connectors of Video Output Board 1
    and 2 for monitor selection
    Logical Camera number (LCN):Numbers set for the CAM-
    ERA IN connectors (CAM 1 to 256) of Video Input
    Board 1 to 8 for camera selection. As the factory
    default, LCN 1 to 256 are given to the CAM 1 to 256 in
    numerical order.
    Note:LCN setting changes are performed in System –
    Logical Camera Number of WJ-SX650 Series
    Administrator Console.
    Recorder number:Unit Address (System) numbers
    (Recorder 1 to 16) set for recorders in SETUP MENU of
    recorders for recorder selection. In this document, Unit
    Address (System) 001 is mentioned as Recorder 1.
    Level:Refer to p. 55.
    Priority:Refer to p. 55.
    Camera Access:Refer to p. 55.
    Recorder Access:Refer to p. 55.
    Login:Refer to p. 56.
    Logout:Refer to p. 56.
    Auto login:Function to log into the system automatically as
    a registered operator. Refer to p. 56.
    Auto logout:Function to log out of the system automatical-
    ly after no operations have been performed during the
    specified period. Refer to p. 56.
    Camera Title:Titles for camera identification, which are
    displayed on associated monitors, can be set up. Up to
    20 characters are available for the camera title. Camera
    title setting will be performed in Camera – Camera
    Title of WJ-SX650 Series Administrator Console.
    Monitor lock:Refer to p. 57.
    Preset (Preset position):Cameras function to register
    camera monitoring positions (preset positions) associ-
    ated with position numbers. By entering the preset posi-
    tion numbers, operators can move cameras to the pre-
    set positions. (Refer to p. 58.) Registered preset posi-
    tions can be applied for event settings such as
    sequence. 
    Home position:Default preset position. If the home posi-
    tion is registered, you can move the camera to the
    home position without specifying the preset position
    number.
    Auxiliary (AUX) control:You can control auxiliary devices
    (buzzer, etc.) connected to cameras or receivers.
    (Refer to p. 79.) Auxiliary control can be applied for
    event settings such as sequence. 
    Auto tracking:Cameras function to detect motion of the
    image and track the moving object automatically. Refer
    to p. 71 and the operating instructions of cameras sup-
    porting this function.
    Patrol:Cameras function to learn and reproduce camera
    operations and picture quality. (Refer to pp. 71 and 78.)Cleaning (Camera Cleaning):Function to clean the slip
    ring to eliminate picture quality deterioration and noise.
    (Available for Panasonic cameras released in 1999 or
    later)
    Camera position:You can associate camera numbers with
    preset position numbers to register as camera positions
    (CAM-P).
    Camera selection recall: Refer to p. 58.
    All cameras control:You can deactivate all auxiliary
    devices at a time, or move all cameras to the home
    positions. Refer to p. 59.
    Spot:A selected camera image is continuously displayed
    on a selected monitor.
    Tour sequence:Refer to p. 62.
    Group sequence:Refer to p. 62.
    Group preset:Refer to p. 62.
    Alarm signal:General term for terminal alarm, camera
    alarm, recorder alarm, serial alarm, and video loss.
    Terminal alarm:Alarm input signals which are supplied
    from alarm sensors (door switch, etc.) to the alarm input
    (ALARM IN) ports of the unit.
    Camera alarm:Alarm input signals which are supplied
    from cameras to the unit by alarm sensors or cameras
    motion detectors, etc.
    Recorder alarm:Alarm input signals which are supplied
    from recorders to the unit by video loss or VMD, etc.
    Serial alarm:Alarm input signals which are supplied as
    serial commands from a PC to the SERIAL port of the
    unit. Alarm commands which are input from the DATA
    ports set to PSD are also serial alarms. (Refer to p. 86.)
    Video loss:Alarm input signals which are supplied to the
    unit when the loss of video input signals are detected
    due to coaxial cable disconnections or camera trou-
    bles.
    Alarm event:Refer to p. 66.
    Alarm schedule:Function to schedule the period when no
    alarm events occur even with alarm input signals 
    Monitor display mode:Display mode which can be acti-
    vated for alarm events during alarm occurrence. There
    are three types of alarm modes: spot, tour sequence,
    and group sequence. These modes can be set sepa-
    rately for each monitor.
    Alarm suspension:Operation to suspend alarm occur-
    rence to the unit.
    Alarm History Display:Refer to p. 69.
    System Status Display:Refer to p. 37.
    Timer event:Refer to p. 71.
    Camera event:Refer to p. 71.
    VD2:Timing pulse to display the images of Panasonic cam-
    eras on the monitor. If VD2 is set to ON, image switch-
    ing unconformity can be prevented. (Depending on
    monitors, the unconformity may not be solved com-
    pletely.)
    Cable compensation:If coaxial cables connected
    between the cameras and the unit are longer than the
    suitable length, video input signals may be attenuated. 
    						
    							88
    Cable compensation is the function to compensate the
    attenuation.
    Export:Function to save the settings of tour sequence or
    group sequence in export files (csv format). This func-
    tion is available when using WJ-SX650 Series
    Administrator Console. Export is performed separately
    for each sequence program. 
    Import:Function to read export files (csv format) into WJ-
    SX650 Series Administrator Console. 
    						
    							89
    • Check if the power cord is properly inserted into the AC inlet
    socket of this unit.
    • The cooling fan has a trouble or is deteriorating. That may
    cause troubles of the unit. Consult the dealer for replace-
    ment.
    • Check the connections between the system controller and
    the unit.
    • Check the specifications of modular cable. When using a
    modular cable not supplied to the system controller, apply the
    6-conductor type.
    Troubleshooting
    Check the following before requesting repair.
    If a trouble cannot be corrected even after checking and trying remedy, contact your dealer.
    Matrix Switcher WJ-SX650 Series
    • Check if the power plug is properly connected to the AC out-
    let.
    Power is not turned on.
    OPERATE indicator is blink-
    ing.
    Cannot control a system con-
    troller.
    Cannot control a monitor.
    Check item and remedy ReferenceProblem
    –
    –
    6
    34
    95
    • Check if the operation mode and controller numbers are
    properly set.
    34
    • Check the DATA port setting (TMNL or PSD).
    • Check the connection between the monitor and the unit.
    52
    29
    • Check the level settings or monitor access setting. 
    55
    • Check the LCD (or LED) display or indicators of system con-
    troller. When Busy (or BUSY) is blinking (or lighting), moni-
    tor control is not available.
    14, 15 
    						
    							90
    • Check the connection between the camera and the unit. If a receiv-
    er is being used, check if the power is supplied to the camera.
    • Check if the selected camera input channel is not set to
    accept video input signals from recorder.  
    • Check the level settings or camera access setting.
    • When the unit is powered on or a camera is connected, black
    bars may be seen on the monitor for several seconds with
    images not supporting VD2 (images from recorder or cam-
    eras of other manufacturers). To eliminate the black bars, set
    VD2 to OFF.
    Black bars can be seen on a
    monitor.
    Cannot control a camera or
    receiver.
    Cannot select a recorder.
    Cannot control a recorder.
    Check item and remedy ReferenceProblem
    53
    27
    50
    55
    • Check the LCD (or LED) display or indicators of system con-
    troller. When Busy (or the BUSY indicator) is blinking (or
    lighting), camera control is not available.
    14, 15
    Coaxial communication:
    •
    Check if the DATA setting of the camera input channel is ON
    in VD2/DATA/CABLE COMPENSATION of SETUP MENU.
    •Check if the camera input channel is not set for RS-485
    communication in RS485 CAMERA of SETUP MENU.
    RS-485 communication:
    •Check if the RS-485 port and unit numbers of camera input
    channel is set properly in RS485 CAMERA of SETUP
    MENU.
    53
    53
    • 
    Check if the LCN is set for the camera input channel accepting
    video input signals from the recorder. Check the setting in
    “System” – “Recorder” of WJ-SX650 Series Administrator
    Console.
    51
    • Check the connection and settings between the recorder and
    the unit.
    • Check the DATA port setting (HDR). 
    • Check the level settings or recorder access setting.
    30
    52
    55 
    						
    All Panasonic manuals Comments (0)