Page 331
2.10 [4] Extension PC Programming Manual 331 F-1–F-12: The call arriving at a flexible CO button (F-1–F-12) is selected. A flexible CO button customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected. Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References 2.10.10 [4-2-3] Portable Station—Flexible Button Feature Manual References 1.10.2 Line Preference—Incoming Call Waiting Tone Type Selects the type of Call Waiting tone sent...
Page 332
2.10 [4] Extension 332 PC Programming Manual Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Option 5 Extension Number Indicates the extension number of the PS (reference only). Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References 2.7.12 [1-2] Portable Station—Extension No. Feature Manual References None Extension Name Specifies the name of the PS. Default Not...
Page 333
2.10 [4] Extension PC Programming Manual 333 Default Language1 Value Range Language1–Language5 Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References None Feature Manual References 1.4.7 Display Information Incoming Call Display Selects which caller information is shown on the first line of the PSs display. Default Caller ID Name Value Range Caller ID Name, CO Line Name Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings...
Page 334
2.10 [4] Extension 334 PC Programming Manual Programming Manual References None Feature Manual References 1.4.7 Display Information Option 6 Extension Number Indicates the extension number of the PS (reference only). Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References 2.7.12 [1-2] Portable Station—Extension No. Feature Manual References None Extension Name Specifies the name of the...
Page 335
2.10 [4] Extension PC Programming Manual 335 SVM Lock Selects whether Simplified Voice Message Log information can be displayed at the extension or other extensions. Default Unlock Value Range Lock, Unlock Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References 2.10.12 [4-2-4] Portable Station—Simplified Voice Message Feature Manual References 1.16.5 SVM (Simplified Voice Message) Flexible Button Programming Mode Specifies whether the PS user can...
Page 336
2.10 [4] Extension 336 PC Programming Manual Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References 2.7.12 [1-2] Portable Station—Extension No. Feature Manual References None Extension Name Specifies the name of the PS. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References 2.7.12...
Page 337
2.10 [4] Extension PC Programming Manual 337 Programming Manual References None Feature Manual References 1.5.1 EFA (External Feature Access) 1.6.2 Flash/Recall/Terminate Incoming Call Log Memory Specifies the number of incoming CO line calls that are retained in the PSs Incoming Call Log memory. Default 10 Value Range 0–100 Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References None Feature Manual References 1.3.3 Call Log, Incoming Option 8...
Page 338
2.10 [4] Extension 338 PC Programming Manual Extension Name Specifies the name of the PS. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References 2.7.12 [1-2] Portable Station—Extension Name Feature Manual References None Group CW w/o Tone (Ring after Call) Enables an incoming call to an incoming call distribution group to arrive at a previously busy extension at the moment that the extension goes...
Page 339
2.10 [4] Extension PC Programming Manual 339 Value Range 0–3000 s Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References None Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out FWD / DND Reference Call Forwarding (FWD) and Do Not Disturb (DND) settings for each PS can be referred. FWD and DND settings can be programmed separately for each PS in 2.10.9 [4-2-2] Portable Station—FWD / DND. Extension Number Indicates the extension number...
Page 340
2.10 [4] Extension 340 PC Programming Manual Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References 2.7.12 [1-2] Portable Station—Extension Name Feature Manual References None FWD Set for Call from CO Indicates the current FWD status for incoming CO line calls (reference only). Default Off Value Range Off, On Maintenance Console Location 2.10.8 [4-2-1] Portable Station—Extension Settings Programming Manual References 2.10.9 [4-2-2] Portable...