2.16 [10] Maintenance
PC Programming Manual 431
Remote—Password Lock Counter for Remote Programming
Specifies the number of successive incorrect password entries allowed before remote access is 
locked.
Default
None
Value Range
None, 1–15
Maintenance Console Location
2.16.1 [10-1] Main
Programming Manual References
None
Feature Manual References
1.13.5 PC Programming
Remote—Remote Maintenance Dial Number (Own Telephone number for 
reference)
Specifies the telephone number of the PBX used to access the...

Page 432

2.16 [10] Maintenance
432 PC Programming Manual
System Password - PT Programming—Prog ** : User Level
Specifies the user level system password to authorize the PT user to access only the permitted 
system programming.
Default
1234
Value Range
4–10 digits (consisting of 0–9)
Maintenance Console Location
2.16.1 [10-1] Main
Programming Manual References
None
Feature Manual References
1.13.15 PT Programming
System Password - PT Programming—Prog *# : Administrator Level
Specifies the administrator level...

Page 433

2.16 [10] Maintenance
PC Programming Manual 433
Value Range
4–10 digits (consisting of 0–9)
Maintenance Console Location
2.16.1 [10-1] Main
Programming Manual References
None
Feature Manual References
1.11.1 Manager Features
System Password - PC Programming—User Level
Specifies the system password used to access KX-TAW848 Maintenance Console at User Level.
Default
1234
Value Range
4–10 digits (consisting of 0–9)
Maintenance Console Location
2.16.1 [10-1] Main
Programming Manual References
None
Feature...

Page 434

2.16 [10] Maintenance
434 PC Programming Manual
Feature Manual References
1.13.5 PC Programming
System Password - PC Programming—Installer Level
Specifies the system password used to access KX-TAW848 Maintenance Console at Installer Level.
Default
1234
Value Range
4–10 digits (consisting of 0–9)
Maintenance Console Location
2.16.1 [10-1] Main
Programming Manual References
None
Feature Manual References
1.13.5 PC Programming
2.16.2 [10-2] PT Programming Access
The programming items accessible at User and...

Page 435

2.16 [10] Maintenance
PC Programming Manual 435
PROG**
Selects whether User Level PT users can access each system programming item.
Default
000–009, 020–099: Enable
010–019, 100–999: Disable
Value Range
Disable, Enable
Maintenance Console Location
2.16.2 [10-2] PT Programming Access
Programming Manual References
None
Feature Manual References
1.13.15 PT Programming 

Page 436

2.16 [10] Maintenance
436 PC Programming Manual 

Page 437

PC Programming Manual 437
Section 3
Appendix 

Page 438

3.1 Feature Programming References
438 PC Programming Manual
3.1 Feature Programming References
A
Absent Message
2.8.8 [2-6-1] Numbering Plan—Main—Features—Absent Message Set / Cancel
2.10.1 [4-1-1] Wired Extension—Extension Settings—Option 3—Absent Message
2.10.8 [4-2-1] Portable Station—Extension Settings—Option 3—Absent Message
2.12.5 [6-5] Absent Message
Feature Manual Reference
1.1.1 Absent Message
Account Code Entry
2.8.8 [2-6-1] Numbering Plan—Main—Features—Account Code Entry
2.8.11 [2-7-1]...

Page 439

3.1 Feature Programming References
PC Programming Manual 439
– Tone Length—Reorder Tone for PT Handset
– Tone Length—Reorder Tone for PT Hands-free
Feature Manual Reference
1.1.5 Automatic Extension Release
Automatic Fax Transfer
2.11.4 [5-3-2] Voice Message—DISA Message—Fax Extension
Feature Manual Reference
1.1.6 Automatic Fax Transfer
Automatic Time Adjustment
2.8.1 [2-1] Date & Time/Daylight Saving
2.8.17 [2-9] System Options—Option 2—Automatic Time Adjustment—by Caller ID (FSK)
Feature Manual...

Page 440

3.1 Feature Programming References
440 PC Programming Manual
Call Hold
2.8.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone
– Recall—Hold Recall
– Recall—Disconnect after Recall
2.8.8 [2-6-1] Numbering Plan—Main—Features
– Call Hold / Call Hold Retrieve
– Call Hold Retrieve : Specified with a Holding Extension Number
– Hold Retrieve : Specified with a Held CO Line Number
2.8.17 [2-9] System Options
– Option 1—PT Operation—Automatic Hold by ICM / CO / ICD Group key
– Option 1—PT Operation— Hold...
Start reading Panasonic Kx Taw848 PC Cprogramming Manual

Related Manuals for Panasonic Kx Taw848 PC Cprogramming Manual

All Panasonic manuals