Page 201
2.9 [3] Group PC Programming Manual 201 Value Range Max. 20 characters Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References None Host PBX Access Code 1–10 Specifies the feature number used to access a CO line from the host PBX. Default Not stored. Value Range Max. 10 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References...
Page 202
2.9 [3] Group 202 PC Programming Manual Maintenance Console Location 2.9.2 [3-1-2] Trunk Group—Local Access Priority Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.11 CO Line Access 1.7.1 GROUP FEATURES 2.9.3 [3-2] Extension User Group Extensions can be assigned to a tenant according to their extension user groups. An extension user group can belong to only one tenant. However, one extension user group can belong to several call pickup groups and several...
Page 203
2.9 [3] Group PC Programming Manual 203 Maintenance Console Location 2.9.3 [3-2] Extension User Group Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.7.1 GROUP FEATURES 1.17.2 Tenant Service 2.9.4 [3-3] Call Pickup Group Extensions can be assigned to a call pickup group according to their extension user groups. One extension user group can belong to up to 8 call pickup groups. A maximum of 64 call pickup groups can be programmed. To assign extension user groups to...
Page 204
2.9 [3] Group 204 PC Programming Manual Value Range None, 01–64 Maintenance Console Location 2.9.4 [3-3] Call Pickup Group Programming Manual References 2.10.1 [4-1-1] Wired Extension—Extension Settings 2.10.8 [4-2-1] Portable Station—Extension Settings Feature Manual References 1.3.6 Call Pickup 1.7.1 GROUP FEATURES 2.9.5 [3-3] Call Pickup Group—All Setting Extensions can be assigned to a call pickup group according to their extension user groups. One extension user group can belong to multiple call...
Page 205
2.9 [3] Group PC Programming Manual 205 Value Range ON (blue), OFF Maintenance Console Location 2.9.5 [3-3] Call Pickup Group—All Setting Programming Manual References 2.9.3 [3-2] Extension User Group 2.9.4 [3-3] Call Pickup Group Feature Manual References 1.3.6 Call Pickup 1.7.1 GROUP FEATURES 2.9.6 [3-4] Paging Group Extensions can be assigned to a paging group according to their extension user groups. External pagers can also be assigned to a paging group. One extension user group or external pager...
Page 206
2.9 [3] Group 206 PC Programming Manual Default Same as extension user group number Value Range None, 01–32 Maintenance Console Location 2.9.6 [3-4] Paging Group Programming Manual References 2.9.3 [3-2] Extension User Group 2.9.7 [3-4] Paging Group—All Setting Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging 2.9.7 [3-4] Paging Group—All Setting Extensions can be assigned to a paging group according to their extension user groups. One extension user group or external pager can belong to...
Page 207
2.9 [3] Group PC Programming Manual 207 Default ON for same numbered paging group Value Range ON, OFF Maintenance Console Location 2.9.7 [3-4] Paging Group—All Setting Programming Manual References 2.9.3 [3-2] Extension User Group 2.9.6 [3-4] Paging Group Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging 2.9.8 [3-4] Paging Group—External Pager External pagers can be assigned to a paging group. One external pager can belong to multiple paging groups. Paging Group Name Indicates the name of the...
Page 208
2.9 [3] Group 208 PC Programming Manual Default ON Value Range ON (blue), OFF Maintenance Console Location 2.9.8 [3-4] Paging Group—External Pager Programming Manual References 2.10.1 [4-1-1] Wired Extension—Extension Settings 2.10.8 [4-2-1] Portable Station—Extension Settings Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Extensions can be assigned as members of an incoming call distribution group. Calls to an incoming call...
Page 209
2.9 [3] Group PC Programming Manual 209 Feature Manual References None Group Name Specifies the name of the incoming call distribution group. Default ICD Group 001–ICD Group 128 Value Range Max. 20 characters Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References None Distribution Method Selects the method for distributing calls to idle extensions of the incoming call distribution group. Default Ring Value...
Page 210
2.9 [3] Group 210 PC Programming Manual Value Range All, Distribution Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References 1.9.2 ICD Group Features—Group Call Distribution FWD Mode Specifies whether extensions in FWD mode ring when a call is received at the incoming call distribution group. Default Ring Value Range No Ring, Ring Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution...