31 System Programming • LCR Itemized Bill Code Assigns whether to register the itemized bill code (extension number 21 through 26) to each CO line or not. This code is used for dividing a bill to a CO line. Input Format: #86 [A] [B] • [A]=1: CO1/ 2: CO2 • [B]=0: DISABLE (default)/ 1: ENABLE •BTL Access Code Stores the BTL (British Telecom Line) access code. When this code is dialled, the BTL is always selected even if the LCR feature is enabled. Input Format: #87 [code] # • [code]=4 digits max. (default: 121) •LCR Route Exceptional Code Assigns dialling numbers that are excepted from LCR routing plans of the specified carrier. You can store a maximum of 20 codes for each route. Input Format: #88 [A] [B] [code] # • [A]=Route No.: 1 through 4 • [B]=Area code No.: 00 through 19 • [code]= 6 digits max. (Default: all routes – not stored) •LCR Leading Digit Entry Registers Leading digits of an area code to judge whether to select a route for the LCR feature. When the first digit of the dialled number matches with the registered number, it is considered a long distance call and proceeds to the LCR procedure. Input Format: #89 [code] # • [code]=2 digits max. (default: 0) Conditions • To clear the LCR route selection code, press #83 [A] [BB] # • To clear the LCR authorization code, press #85 [password] [A] [B] # • To clear the BTL access code, press #87#. • To clear the LCR route exceptional code, press #88 [A] [B] # Least Cost Routing (LCR) Programs (continued) •LCR Mode Allows you to turn on or off the Least Cost Routing (LCR) mode. LCR, if enabled, selects the least expensive route to be used for a CO call. Input Format: #80 [A] [B] • [A]=1: CO1/ 2: CO2 • [B]=0: DISABLE (default)/ 1: ENABLE •LCR Carrier Code Assigns each carriers access code used for the LCR feature. Input Format: #81 [A] [code] # • [A]=Route No.: 1 through 4 • [code] =10 digits max. (Default : all routes – 131) •LCR Modify Mode Assigns whether to change the numbers after the carrier code to the TONE mode or not when “#01 Dial Type Selection” program is assigned as “Pulse”. Input Format: #82 [A] [B] • [A]=Route No.: 1 through 4 • [B]=0: PULSE/1: TONE (default) •LCR Route Selection Code Assigns area codes (except the leading digit) which is selected by the LCR feature for each route. You can store a maximum of 40 codes for each route. Input Format: #83 [A] [BB] [code] # • [A]= Route No.: 1 through 4 • [BB]= Code No.: 00 through 39 • [code]=6 digits max. (Default: Not stored) •LCR Password Set Assigns a password to register an authorization code. The password is not displayed on the display panel during setting. Input Format: #84 [old password] [new password] • [Password]=4 digits max. (default: 1234) • LCR Authorization Code Set Registers an authorization code applied to each CO line and each route. The authorization codes are not displayed on the display panel during setting. Input Format: #85 [password] [A] [B] [code] • [password]=enter the password set by # 84 program • [A]=Route No.: 1 through 4 • [B]=1: CO1/ 2: CO2 • [code]=20 digits max. (Default: both CO lines, all routes – not stored)
Tone / Ring Tone 32 1 sec 15 sec Confirmation Tone 1 Confirmation Tone 2 Confirmation Tone 3 (Conference Tone) Dial Tone 1 Dial Tone 2 Busy Tone Reorder Tone Ringback Tone Do Not Disturb (DND) Tone Hold Alarm Call Waiting Tone
Tone / Ring Tone 33 1 sec Intercom Calls / Intercom Hold Recall CO Calls / CO Hold Recall Doorphone Calls NOTE • The dial tone 2 is heard during the system programming mode and when the following features are set: Do Not Disturb Call Pickup Deny Call Forwarding Data Line Security
Programming Tables 34 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 [#00] System Speed Dialling Number Set No.Phone No. (32 digits max.) Name
Programming Tables 35 Code 00 01 02 03 04 [#01] Dial Type Selection DefaultExt.21 Ext.22 Ext.23 Ext.24 Ext.25 Ext.26 [#03] Outgoing Permitted CO 2 Assignment (Day) [#04] CO 1 Ringing Assignment (Day) 0: DISABLE 1: ENABLE DefaultExt.21 DefaultExt.22 Ext.23 Ext.24 Ext.25 Ext.26 [#05] CO 2 Ringing Assignment (Day) DefaultExt.21 Ext.22 Ext.23 Ext.24 Ext.25 Ext.26 1: CLASS 1 2: CLASS 2 3: CLASS 3 4: CLASS 4 Default CO1 CO2 0: PULSE 1: TONE 0: DISABLE 1: ENABLE [#77] Toll Restriction (TRS) – Class Assignment (Night) [#72] Outgoing Permitted CO 1 Assignment (Night) [#08] TRS Denied Code (CLASS 2, 3) Code 0 1 2 3 4 5 6 7 8 9 [#13] CO 1 Delayed Ringing Assignment [#09] TRS Denied Code (CLASS 3) [#07] Toll Restriction (TRS) – Class Assignment (Day) [#14] CO 2 Delayed Ringing Assignment DefaultExt.21 Ext.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE DefaultExt.21 Ext.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE DefaultExt.21 Ext.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE DefaultExt.21 DefaultExt.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE DefaultExt.21 DefaultExt.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE DefaultExt.21 DefaultExt.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE [#76] Doorphone Assignment (Night) [#75] CO 2 Ringing Assignment (Night) [#74] CO 1 Ringing Assignment (Night) [#06] Doorphone Assignment (Day) DefaultExt.21 Ext.22 Ext.23 Ext.24 Ext.25 Ext.26 1: CLASS 1 2: CLASS 2 3: CLASS 3 4: CLASS 4 [#73] Outgoing Permitted CO 2 Assignment (Night) DefaultExt.21 Ext.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE DefaultExt.21 Ext.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE Number (7 digits)Code 0 1 2 3 4 5 6 7 8 9Number (7 digits) Number (7 digits) [#16] TRS Excepted Code DefaultExt.21 DefaultExt.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE DefaultExt.21 DefaultExt.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE Number (7 digits)Code 05 06 07 08 09 Number (7 digits)Code 10 11 12 13 14 Number (7 digits)Code 15 16 17 18 19 Number (7 digits)Code 20 21 22 23 24 Number (7 digits)Code 25 26 27 28 29 SelectionDefault 1: 1 RING 2: 2 RINGS 3: 3 RINGS 4: 4 RINGS [#15] Delayed Ringing Count Selection 0: DISABLE 1: ENABLESelection Default [#12] Fax Connection [ #02] Outgoing Permitted CO 1 Assignment (Day)
Programming Tables 36 No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 [#83] LCR Route Selection Code Code (6 digits max.) Route 1 Code (6 digits max.) Route 2 No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39Code (6 digits max.) Route 3 Code (6 digits max.) Route 4 DefaultExt.21 Ext.22 Ext.23 Ext.24 Ext.25 Ext.26 0: DISABLE 1: ENABLE [#61] Door Opener Assignment [#70] Day/Night Switching Mode[#71] Day/Night Starting Time 0: MANUAL 1: AUTOSelection Default 1: DAY 2: NIGHTSelection Default 9:00AM 5:30PM
Programming Tables 37 [#88] LCR Route Exceptional Code No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19Code (6 digits max.) Route 1 Code (6 digits max.) Route 2 No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19Code (6 digits max.) Route 3 Code (6 digits max.) Route 4
Templet 39 39 106 mm Install a screw here Install a screw here 71 mm 77 mmInstall a screw here • Copy the templet and place it on the wall. Up
Panasonic Business Systems U.K. Panasonic House, Willoughby Road, Bracknell, Berkshire RG12 4FP Printed in JapanPSQX1141ZB KW0397KM1097