    							11
    System Connection Diagram
    P
    a
    n
    a
    s
    o
    n
    i
    cPanasonicA
    U
    T
    O
     
    S
    C
    A
    NAUTO SCAN10CH10CH
    P
    a
    n
    a
    s
    o
    n
    i
    cPanasonic
    PanasonicPanasonicELECTRONICMODULARSWITCHINGSYSTEM
    2 CO Lines
    Doorphone KX-T30865
    Doorphone
    6 Extensions
    (one pair)
    (two pair)(two pair)
    (two pair)
    (one pair) (one pair)KX-T7130
    KX-T7050 Single Line Telephone
    Cordless Phone
    Telephone Answering
    Machine with FacsimileKX-T7020to CO1 and CO2
    Door Opener 
    						
    							12
    CO Line Connection
    Wire SpecificationThe wire specifications are as follows:
    WireSolid wire
    Diameter of conductorø 0.4 – ø 0.65mm
    Diameter with coatingø 0.66 – ø 1.05mm
    ConnectionUse a 4-pin plug (included) to connect CO lines.
    A single plug is able to connect two CO lines.  Use twisted pair cable.
    1. Lift the transparent part.
    2. Insert the required telephone wires into the holes of the plug.
    Then press the transparent part back into the black part.
    Note: Do not strip the wires.
    Insert the wires all the way into the plug.
    GROUND
    SYSTEM
    EXTN.
    5
    EXTN.
    3
    EXTN.
    1
    CO 2
    CO 1
    EXTN.
    6
    EXTN.
    4
    EXTN.
    2
    DPH
    DOOR
    OPENER
    A
    A B
    B
    CO 2
    CO 1CO 2
    CO 1
    To Modular Jacks from
    the Central Office
    A
    B
    CO 2
    A
    BCO 1
    CO 2
    CO 1
    Note
    •You can use cable holders to fix the wires. 
    						
    							13
    Extension Connection
    Wire SpecificationThe wire specifications are as follows:
    WireSolid wire
    Diameter of conductorø 0.4 – ø 0.65 mm
    Diameter with coatingø 0.66 – ø 1.05 mm
    ConnectionUse a 4-pin plug (included) to connect extension lines.
    There are 6 plugs to connect extensions to EXTN. 1 through EXTN. 6
    jacks.
    1. Lift the transparent part.
    2. Insert the required telephone wires into the holes of the plug.
    Then press the transparent part back into the black part.
    Note: Do not strip the wires.
    Insert the wires all the way into the plug.
    H
    A
    B
    L
    A
    B
    For a proprietary telephone
    For single line telephones
    GROUND
    SYSTEM
    EXTN.
    5
    EXTN.
    3
    EXTN.
    1
    CO 2
    CO 1
    EXTN.
    6
    EXTN.
    4
    EXTN.
    2
    DPH
    H
    B A
    L
    EXTN.
    1
    DOOR
    OPENER
    To extensions
    Notes
    •A facsimile must be connected to EXTN.6 jack if an optional DISA/FAX Detect card (KX-
    T20691) is installed.  See page 16 to install the card.  System programming is also required.
    The “#12 Fax Connection” program should be assigned as “ENABLE”.  See page 25.  The
    “#24 Call Incoming Mode Selection” program should be assigned as “DISA”.  See page 28.
    •The EXTN.1 through EXTN.6 jacks correspond to extension numbers 21 through 26 respec-
    tively.
    •You can use cable holders to fix the wires. 
    						
    							14 Any single line telephone can be connected in parallel with a proprietary telephone.
    ELECTRONICMODULARSWITCHINGSYSTEMP
    O
    W
    E
    R
    Paralleled Telephone Connection
    Notes
    • The following features are not available for SLT connected in parallel:
    Call Splitting
    External Feature Access
    Conference
    4-conductor wiring cord
    Connect pins “H”, “A”,
    “B”, and “L”.2-conductor wiring cord
    Connect pins “A” and “B”.
    Master
    socket Secondary
    socket 
    						
    							15
    Installation of Optional Card and Unit
    Doorphone (KX-T30865) Connection
    2-conductor wiring cord
    KX-T30865
    Notes
    •The doorphone adaptor is not required for KX-T206.
    •To avoid howling, you must assign all extensions as “DISABLE” in the “#06/#76 Doorphone
    Assignment (Day/Night)” program when you do not connect a doorphone.
    •If howling occurs while using the doorphone feature, check the wiring.
    •You can use cable holders to fix the wires.
    Door Opener Connection
    A user-supplied door opener can be connected to the system.
    GROUND
    EXTN.
    5
    EXTN.
    3
    EXTN.
    1
    CO 2
    CO 1
    EXTN.
    6
    EXTN.
    4
    EXTN.
    2
    DPH
    DOOR
    OPENER
    SYSTEM
    3. Wind and fix the cables of the door opener
    round the upper cable holder. 1. Loosen the screws. 2. Insert the wires coming from the door
    opener into holes and tighten the screws.
    DOOR
    OPENER
    Notes
    •For wiring, it is recommended to use UL1015 twisted wire or the equivalent.
    •The wire should be between 1.2 and 2.4 mm in diameter including the coating.
    GROUND
    SYSTEM
    EXTN.
    5
    EXTN.
    3
    EXTN.
    1
    CO 2
    CO 1
    EXTN.
    6
    EXTN.
    4
    EXTN.
    2
    DPH
    B A
    P
    a
    n
    a
    s
    o
    n
    i
    cPanasonic
    DPH
    DOOR
    OPENER
    D=1.2–2.4 mm
    GROUND
    EXTN.
    5
    EXTN.
    3
    EXTN.
    1
    CO 2
    CO 1
    EXTN.
    6
    EXTN.
    4
    EXTN.
    2
    DPH
    DOOR
    OPENER
    SYSTEM
    To the door opener
    •Set the door opener paired with the doorphone. 
    						
    							16
    DISA Card (KX-T20691) Connection
    1. Disconnect the AC cord from the system.
    2. Loosen the screws and remove the cover.3. Attach the DISA card to the marked connectors.
    4. Replace the cover and secure the screws.
    5. Connect the AC cord again.
    CO2
    CO 1
    DOOR
    PHONE
    GROUND
    EXTN.
    5
    EXTN.
    3
    EXTN
    1E
    X
    T
    N
    .
    6
    E
    X
    T
    N
    .
    4
    E
    X
    T
    N
    .
    2
    D
    P
    H
    P
    O
    W
    E
    R
    ELECTRONIC MODULAR SWITCHING SYSTEM
    The DISA feature allows an outside caller to have direct access to intercom calls.  System pro-
    gramming is required.  See “#10 OGM Recording” on page 24 and “#24 Call Incoming Mode
    Selection” on page 28.
    Keep the following conditions in mind:
    •When a caller enters the second digit of an extension number (1 through 6) during the mes-
    sage, he/she can reach the extension directly.
    •If the call is not received, the assigned extensions will ring.  See “#04/#74 CO1 Ringing
    Assignment (Day/Night), “#05/#75 CO2 Ringing Assignment (Day/Night)” on page 22 and
    “#60 DISA Ringing Time” on page 29.
    •If the caller enters 0, the assigned extensions can receive his/her call.  See “#04/#74 CO1
    Ringing Assignment  (Day/Night), “#05/#75 CO2 Ringing Assignment (Day/Night)” on page
    22.
    •If the caller enters 7, 8 or 9, or enters nothing, extension 21 will receive his/her call.
    •Any calls from a rotary phone will be received by extension 21.
    Installation of Optional Card and Unit 
    						
    							17
    Installation of Lightning Protectors
    Overview
    A lightning protector is a device to be installed on a CO line to prevent a dangerous surge from
    entering the building and damaging equipment.
    A dangerous surge can occur if a telephone line comes in contact with a power line.  Trouble due
    to lightning surges have been showing a steady increase with the development of electronic
    equipment.
    In many countries, there are regulations requiring the installation of a lightning protector.
    A lightning strike to a telephone cable which is 10 m above ground can be as high as 200,000
    volts.
    This system should be installed with lightning protectors.
    In addition, grounding (connection to earth ground) is very important for the protection of the
    system.
    Installation
    CO CO CO
    EXTN
    EXTN
    Frame
    Earth EXTN
    SLT PT
    EarthMain
    Distribution 
    FrameMain Unit
    Earth Terminal
    Lightning
    Protectors 
    						
    							18
    Installation of an Earth Rod
    Notice
    If you install an extension outside of the main building, the following precautions are recom-
    mended:
    (1) Install the extension wire underground.
    (2) Use a conduit to protect the wire.
    Note
    •The lightning protector for an extension is different from that for CO.
    (1) Installation location of the earth rod ...... Near the protector
    (2) Check obstructions ................................ None
    (3) Composition of the earth rod ................. Metal
    (4) Depth of the earth rod ............................ More than 50 cm
    (5) Size of the earth wire ............................. Thickness is greater
    than 1.6 mm
    Notes
    •The above figures are recommendations only.
    •The length of earth rod and the required depth depend on the
    composition of the soil.
    Installation of Lightning Protectors
    Outside
    EarthSLT
    PT
    EXTNEXTN
    EXTN EXTNCO CO COProtectors
    (Another Building) (Main Building)
    Main
    Distribution 
    FrameMain
    UnitLightning
    Protector
    TEL TEL
    Lightning
    Protector
    Main
    Unit
    (Underground)
    Earth Rod Earth WireCO 
    						
    							19
    Power Failure Transfer
    In the event of a power failure, CO2 is connected to extension 22 automatically.
    Note
    •The system programmed data is protected by the factory provided lithium battery.
    Starting the System
    Plug the AC power cord into the system and an AC outlet.
    •The power indicator of the system will light. 
    						
    							20
    General Programming Instructions
    Default SettingThis system has a default factory setting.  If any of the program-
    ming needs to be changed, you can change the setting by system
    programming.
    Required Telephone SetYou can use any of the following telephones for system program-
    ming:
    • Proprietary Telephone (PT): KX-T7130, KX-T7020, KX-T7050
    • Single Line Telephone (SLT): tone type
    All telephones (except KX-T7130) do not have display panels, so
    you cannot check the setting you have made.  Therefore, please use
    KX-T7130 to check the programming.
    Extensions Used forSystem programming can only be performed from extension 21.
    Programming
    To Check theUse KX-T7130.  When you check the assignment, set the
    Programmed DataMEMORY switch on PT to “PROGRAM”.
    Enter “#” and the program address.
    You cannot check programs #60, #62, #63, #65, #67, #84 and #85,
    as they are not displayed on the display panel.
    Before ProgrammingTo enter the system programming mode:
    After ProgrammingTo exit the system programming mode:
    662020[Off-hook]
    6620[Off-hook]
    6 
    						
    All Panasonic manuals Comments (0)