Home > Panasonic > Camera Accessories > Panasonic Indoor Pan Tilt Head Aw Rp400 Operating Instructions

Panasonic Indoor Pan Tilt Head Aw Rp400 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Indoor Pan Tilt Head Aw Rp400 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Cable Compensation Unit  AW-RC400
    AW-RC400
    41
    How to mount the AW-RC400 in a rack
    Use the accessory rack-mounting adaptors and accessory
    mounting screws (M4!8 mm) to mount the unit in a rack.
    1Set the POWER switch at the OFF position to turn off the
    power.
    2Remove four feet on the bottom of the unit.
    3Place the rack-mounting adaptors to the both ends of the
    unit, and fix it using four mounting screws.POWER switch
    Remove four feet.
    Rack-mounting adaptor
    Mounting
    screws 
    						
    							Cable Compensation Unit  AW-RC400
    42
    Specifications
    Input connectors
    DC 12V IN: For connecting optional accessory AC adaptor (AW-PS301)
    G/L IN: BNC!2, automatically terminated by 75-ohm resistance, loop-through output, black burst
    VIDEO/Y, Pr/C, Pb: BNC!3 (5 sets), 75-ohm termination
    Composite
    Y/C
    Component (Y/Pr/Pb)
    MONI SEL IN: RJ45
    Connecting cable: 10BASE-T straight cable (UTP category 5), max. 50 meters
    Output connectors
    G/L OUT: BNC!5, 75-ohm output, BELDEN 8281 connecting cable, max. 1000 meters
    VIDEO/Y, Pr/C, Pb: BNC!3 (5 sets), 75-ohm output
    Composite
    Y/C
    Component (Y/Pr/Pb)
    (Cable compensation adjustment is required)
    MONITOR OUT1/2: BNC!3 (2 sets), 75-ohm output
    Switch and adjustment functions:Power ON/OFF; cable length setting 0/1/2/3/4/5; sync signal setting SHORT/LONG; cable
    compensation amount adjustment; video level adjustment
    Ambient operating temperature:14°F to 113°F (–10°C to +45°C)
    Storage temperature:–4°F to 140°F (–20°C to +60°C)
    Ambient operating humidity:30% to 90% (no condensation)
    Dimensions (W!H!D):16-9/16”!3-7/16”!9-13/16” (420!88!250 mm)
    Weight:Approx. 8.2 lbs (3.7 kg)
    Finish:AV ivory paint (color resembling Munsell 7.9Y6.8/0.8)
    Weight and Dimensions indicated above are approximate.
    Specifications are subject to change without notice.
    Supply voltage:DC 12.0 V
    Power consumption:Approx. 9 W
    1indicates safety information. 
    						
    							Roll Unit  AW-RL400
    AW-RL400
    43
    Introduction
    Accessories
    ≥The AW-RL400 roll unit enables a camera to be rotated
    when it is used in combination with the AW-PH400 indoor
    pan/tilt head.NOTE
    ≥Since the roll unit causes the camera to rotate, the user
    should ensure that all the wiring such as the camera
    cable and lens cable will not become entangled when
    the roll unit is operated.
    ≥When the roll unit is to be discarded at the end of its
    service life, ask a specialized contractor to dispose of it
    properly in order to protect the environment.
    Pan/tilt head connecting cable  ................................................... 1 
    						
    							Roll Unit  AW-RL400
    44
    Parts and their function
    1Rotary ring
    2Camera mounting screw (U1/4”-20UNC)
    After mounting the camera, secure it firmly using this
    screw.
    3Camera mounting plate (A) (B)
    Mount the camera on this plate using the camera
    mounting screws.
    4Camera mounting plate anchoring screws
    After mounting the camera on the camera mounting
    plate, anchor it to the roll unit using these screws.
    5Roll unit anchoring screw holes
    This is where the roll unit is secured to the rotary arm of
    the pan/tilt head.
    6Pan/tilt head connector
    Connect this to the OPTION connector on the pan/tilt
    head using the pan/tilt head connecting cable supplied.
    1
    5
    6 2
    3
    4 
    						
    							Roll Unit  AW-RL400
    AW-RL400
    45
    Installation
    3Loosen the two screws of camera mounting plate which is already installed to the roll unit.
    Then remove the camera mounting plate. 1Attach the pan/tilt head’s rotary arm to the roll unit using the three mounting screws (M5!22 mm, with flat washers, pan/tilt
    head accessory).
    2Attach the rotary arm to the pan/tilt head using the mounting screws (M5!22 mm, with flat washers, pan/tilt head accessory).
    Roll unit
    Camera mounting plate
    (consisting of 2 separate
    sub plates)
    Camera mounting plate
    (consisting of 2 separate
    sub plates)Rotary arm
    Screws
    ❈When assembling the units, use the Allen key (provided), wrench and screwdriver, and secure the units by tightening the
    screws firmly. After mounting the units, check there is no play in the way they are mounted. 
    						
    							Roll Unit  AW-RL400
    46
    Installation
    ❈Be absolutely sure to use a screwdriver or other tool to tighten the two camera mounting screws so that the camera
    mounting plate is secured firmly.
    4Separate the camera mounting plate, which was removed in step 3, into its two
    sub plates.
    ≥Separate the camera mounting plate into sub plate (A) and sub plate (B) by
    loosening the clamping screw.
    Clamping screw
    5Follow the steps below to mount the camera mounting sub plates, which were separated in step 4, onto the camera body.
    When the AW-E750, AW-E650 or AW-E350 is used as the camera
    (1) Remove the screw attached to camera mounting sub plate (A), and use it to mount camera mounting sub plate (B) onto
    the tripod mounting seat.
    (2) Mount camera mounting sub plate (A) onto camera mounting sub plate (B).
    When the AW-E655 is used as the camera
    (1) Mount camera mounting sub plate (A) onto the tripod mounting seat using the two camera mounting screws. 
    						
    							Roll Unit  AW-RL400
    AW-RL400
    47
    Installation
    6Attach the camera mounting plate to the roll unit in a way contrary to the procedure 
    of removing it in step 3.
    Camera mounting plate’s screws
    7Using the pan/tilt head connecting cable provided, connect the [OPTION] connector on the pan/tilt head connector panel and
    the connector on the roll unit.
    OPTION connector
    Pan/tilt head connecting cableLens cable
    8After the roll unit, camera body and pan/tilt head have been mounted, complete the installation by mounting the lens.
    9Connect the lens cable connectors to the camera body and pan/tilt head. 
    						
    							Roll Unit  AW-RL400
    48
    Specifications
    Pan/tilt head connector:Connected to pan/tilt head using cable supplied
    Performance:Maximum load-bearing capability: 8.8 lbs (4 kg)
    Rotary range: 380 degrees (approx. ±190 degrees)
    Maximum operating speed: 60 degrees/sec.
    Repeatability: Less than ±1 degree
    Ambient operating temperature:32°F to 113°F (0°C to +45°C)
    Storage temperature:–4°F to 140°F (–20°C to +60°C)
    Ambient operating humidity:30% to 90% (no condensation)
    Dimensions (W!H!D):8-1/16”!7-13/16”!10-1/4” (205!198!260 mm)
    Weight:Approx. 8.6 lbs (3.9 kg)
    Finish:AV ivory paint (color resembling Munsell 7.9Y6.8/0.8)
    Weight and Dimensions indicated above are approximate.
    Specifications are subject to change without notice.
    Supply voltage:DC 24 V
    Power consumption:Approx. 24 W
    1indicates safety information. 
    						
    							49
    Connections
    ≥Turn off the power of all the equipment before proceeding with the connections.
    ≥Use the AW-PS505 as the AC adaptor for the AW-RP400 pan/tilt control panel. Use the DC cable supplied with
    the AW-PS505 to connect the DC 12V IN socket on the AW-RP400 with the DC 12V OUT socket on the 
    AW-PS505.
    ≥Connect the AC power cable supplied with the AW-PH400 for the AW-PH400 indoor pan/tilt head.
    ≥Use the AC adaptor (optional accessory) for the AW-RC400 cable compensation unit.
    ≥Use 10BASE-T straight cables to connect the IP/RP connectors on the pan/tilt heads with the CONTROL OUT
    TO PAN/TILT HEAD (1 to 5) connectors on the AW-RP400. The maximum extension distance is 500 meters
    when using UTP category 5 cables or their equivalent.
    ≥Use the camera cables supplied with the pan/tilt head to connect the AW-PH400 to the convertible camera.
    ≥Connect the iris control cable of the motorized zoom lens to the IRIS connector on the camera, and connect the
    zoom/focus cable to the LENS I/F connector on the pan/tilt head.
    ≥Use either the AW-CB400 remote operation panel or WV-CB700A remote control box for camera control.
    The AW-CB400 and WV-CB700A cannot be used together.
    ≥When using the AW-CB400, use the cable (10 m) supplied with the AW-CB400 to connect the CAMERA
    CONTROL IN FROM ROP connector on the AW-RP400 with the I/F CONNECTOR on the AW-CB400.
    Five cameras can be controlled from the AW-CB400.
    Power is supplied through this cable from the AW-RP400 to the AW-CB400 so the AC adaptor need not be
    connected to the AW-CB400.
    ≥When using the WV-CB700A, use the RCB cables (2 m) supplied with the WV-CB700A to connect the
    CAMERA CONTROL IN FROM RCB (1 to 5) connectors on the AW-RP400 with the RCB connectors on the
    WV-CB700A.
    Only one camera can be controlled from the WV-CB700A. If there is a multiple number of cameras, one 
    AW-CB700A will be required for each camera. It is also necessary to align the number of the CONTROL OUT
    TO PAN/TILT HEAD connectors connected to the cameras to be controlled with the CAMERA CONTROL IN
    FROM RCB connectors used to connect the WV-CB700A.
    ≥Use the 10BASE-T straight cable to connect the MONI SEL OUT connector on the AW-RP400 with the MONI
    SEL IN connector on the AW-RC400. The maximum extension distance is 50 meters when using a UTP
    category 5 cable or its equivalent.
    By connecting these MONI SEL connectors, the video signals of the camera selected by the AW-RP400 can be
    output from the MONITOR1 connector and the video signals of the camera selected by the AW-CB400 can be
    output from the MONITOR2 connector.
    When the WV-CB700A is used, MONITOR2 cannot be switched.
    ≥Use a coaxial cable to connect the AW-RC400 and AW-PH400.
    ≥Supply the genlock signals from a unit such as a signal generator to the G/L IN connector on the AW-RC400,
    and connect the G/L OUT (1 to 5) connectors on the AW-RC400 with the G/L IN connectors on the pan/tilt
    heads.
    ≥When using composite signals, connect the VIDEO connectors on the pan/tilt heads and Y/VIDEO IN
    connectors (1 to 5) on the AW-RC400.
    Also connect the Y/VIDEO OUT connectors on the AW-RC400 to switchers or monitors.
    ≥When using Y/C signals, connect the Y connectors and Pr/C connectors on the pan/tilt heads to the Y/VIDEO
    IN connectors and Pr/C IN connectors, respectively, on the AW-RC400.
    Also connect the Y/VIDEO OUT connectors and Pr/C OUT connectors on the AW-RC400 to switchers or
    monitors.
    ≥When using component signals, connect the Y connector, Pr/C connector and Pb connector on the pan/tilt head
    to the Y/VIDEO IN connector, Pr/C IN connector and Pb IN connector, respectively, on the cable compensation
    unit.
    Also connect the Y/VIDEO OUT connectors, Pr/C OUT connectors and Pb OUT connectors on the AW-RC400
    to switchers or monitors. 
    						
    							50
    Connections
    Motorized zoom lens
    Iris control
    Convertible camera
    Genlock signals
    Video signals
    Video signal output
    Genlock signal input
    Monitor switching signals
    Monitor signals 1
    Monitor for AW-CB400Monitor for AW-RP400
    Monitor signals 2Camera cable supplied
    with AW-PH400 Zoom/focus
    control
    AW-PH400
    Indoor Pan/Tilt Head
    Pan/tilt head/camera
    control signals
    AC power cable supplied
    with AW-PH400
    AW-RP400
    Pan/tilt control panel AW-CB400
    Remote Operation
    Panel
    Cable supplied with AW-CB400
    (AW-CB400 power and camera
    control signals)AW-RC400 
    Cable
    Compensation Unit
    AW-PS505
    AC adaptorAW-PS301
    AC adaptor 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Indoor Pan Tilt Head Aw Rp400 Operating Instructions