Cable Compensation Unit AW-RC400 AW-RC400 41 How to mount the AW-RC400 in a rack Use the accessory rack-mounting adaptors and accessory mounting screws (M4!8 mm) to mount the unit in a rack. 1Set the POWER switch at the OFF position to turn off the power. 2Remove four feet on the bottom of the unit. 3Place the rack-mounting adaptors to the both ends of the unit, and fix it using four mounting screws.POWER switch Remove four feet. Rack-mounting adaptor Mounting screws
![](/img/blank.gif)
Cable Compensation Unit AW-RC400 42 Specifications Input connectors DC 12V IN: For connecting optional accessory AC adaptor (AW-PS301) G/L IN: BNC!2, automatically terminated by 75-ohm resistance, loop-through output, black burst VIDEO/Y, Pr/C, Pb: BNC!3 (5 sets), 75-ohm termination Composite Y/C Component (Y/Pr/Pb) MONI SEL IN: RJ45 Connecting cable: 10BASE-T straight cable (UTP category 5), max. 50 meters Output connectors G/L OUT: BNC!5, 75-ohm output, BELDEN 8281 connecting cable, max. 1000 meters VIDEO/Y, Pr/C, Pb: BNC!3 (5 sets), 75-ohm output Composite Y/C Component (Y/Pr/Pb) (Cable compensation adjustment is required) MONITOR OUT1/2: BNC!3 (2 sets), 75-ohm output Switch and adjustment functions:Power ON/OFF; cable length setting 0/1/2/3/4/5; sync signal setting SHORT/LONG; cable compensation amount adjustment; video level adjustment Ambient operating temperature:14°F to 113°F (–10°C to +45°C) Storage temperature:–4°F to 140°F (–20°C to +60°C) Ambient operating humidity:30% to 90% (no condensation) Dimensions (W!H!D):16-9/16”!3-7/16”!9-13/16” (420!88!250 mm) Weight:Approx. 8.2 lbs (3.7 kg) Finish:AV ivory paint (color resembling Munsell 7.9Y6.8/0.8) Weight and Dimensions indicated above are approximate. Specifications are subject to change without notice. Supply voltage:DC 12.0 V Power consumption:Approx. 9 W 1indicates safety information.
![](/img/blank.gif)
Roll Unit AW-RL400 AW-RL400 43 Introduction Accessories ≥The AW-RL400 roll unit enables a camera to be rotated when it is used in combination with the AW-PH400 indoor pan/tilt head.NOTE ≥Since the roll unit causes the camera to rotate, the user should ensure that all the wiring such as the camera cable and lens cable will not become entangled when the roll unit is operated. ≥When the roll unit is to be discarded at the end of its service life, ask a specialized contractor to dispose of it properly in order to protect the environment. Pan/tilt head connecting cable ................................................... 1
![](/img/blank.gif)
Roll Unit AW-RL400 44 Parts and their function 1Rotary ring 2Camera mounting screw (U1/4”-20UNC) After mounting the camera, secure it firmly using this screw. 3Camera mounting plate (A) (B) Mount the camera on this plate using the camera mounting screws. 4Camera mounting plate anchoring screws After mounting the camera on the camera mounting plate, anchor it to the roll unit using these screws. 5Roll unit anchoring screw holes This is where the roll unit is secured to the rotary arm of the pan/tilt head. 6Pan/tilt head connector Connect this to the OPTION connector on the pan/tilt head using the pan/tilt head connecting cable supplied. 1 5 6 2 3 4
![](/img/blank.gif)
Roll Unit AW-RL400 AW-RL400 45 Installation 3Loosen the two screws of camera mounting plate which is already installed to the roll unit. Then remove the camera mounting plate. 1Attach the pan/tilt head’s rotary arm to the roll unit using the three mounting screws (M5!22 mm, with flat washers, pan/tilt head accessory). 2Attach the rotary arm to the pan/tilt head using the mounting screws (M5!22 mm, with flat washers, pan/tilt head accessory). Roll unit Camera mounting plate (consisting of 2 separate sub plates) Camera mounting plate (consisting of 2 separate sub plates)Rotary arm Screws ❈When assembling the units, use the Allen key (provided), wrench and screwdriver, and secure the units by tightening the screws firmly. After mounting the units, check there is no play in the way they are mounted.
![](/img/blank.gif)
Roll Unit AW-RL400 46 Installation ❈Be absolutely sure to use a screwdriver or other tool to tighten the two camera mounting screws so that the camera mounting plate is secured firmly. 4Separate the camera mounting plate, which was removed in step 3, into its two sub plates. ≥Separate the camera mounting plate into sub plate (A) and sub plate (B) by loosening the clamping screw. Clamping screw 5Follow the steps below to mount the camera mounting sub plates, which were separated in step 4, onto the camera body. When the AW-E750, AW-E650 or AW-E350 is used as the camera (1) Remove the screw attached to camera mounting sub plate (A), and use it to mount camera mounting sub plate (B) onto the tripod mounting seat. (2) Mount camera mounting sub plate (A) onto camera mounting sub plate (B). When the AW-E655 is used as the camera (1) Mount camera mounting sub plate (A) onto the tripod mounting seat using the two camera mounting screws.
![](/img/blank.gif)
Roll Unit AW-RL400 AW-RL400 47 Installation 6Attach the camera mounting plate to the roll unit in a way contrary to the procedure of removing it in step 3. Camera mounting plate’s screws 7Using the pan/tilt head connecting cable provided, connect the [OPTION] connector on the pan/tilt head connector panel and the connector on the roll unit. OPTION connector Pan/tilt head connecting cableLens cable 8After the roll unit, camera body and pan/tilt head have been mounted, complete the installation by mounting the lens. 9Connect the lens cable connectors to the camera body and pan/tilt head.
![](/img/blank.gif)
Roll Unit AW-RL400 48 Specifications Pan/tilt head connector:Connected to pan/tilt head using cable supplied Performance:Maximum load-bearing capability: 8.8 lbs (4 kg) Rotary range: 380 degrees (approx. ±190 degrees) Maximum operating speed: 60 degrees/sec. Repeatability: Less than ±1 degree Ambient operating temperature:32°F to 113°F (0°C to +45°C) Storage temperature:–4°F to 140°F (–20°C to +60°C) Ambient operating humidity:30% to 90% (no condensation) Dimensions (W!H!D):8-1/16”!7-13/16”!10-1/4” (205!198!260 mm) Weight:Approx. 8.6 lbs (3.9 kg) Finish:AV ivory paint (color resembling Munsell 7.9Y6.8/0.8) Weight and Dimensions indicated above are approximate. Specifications are subject to change without notice. Supply voltage:DC 24 V Power consumption:Approx. 24 W 1indicates safety information.
![](/img/blank.gif)
49 Connections ≥Turn off the power of all the equipment before proceeding with the connections. ≥Use the AW-PS505 as the AC adaptor for the AW-RP400 pan/tilt control panel. Use the DC cable supplied with the AW-PS505 to connect the DC 12V IN socket on the AW-RP400 with the DC 12V OUT socket on the AW-PS505. ≥Connect the AC power cable supplied with the AW-PH400 for the AW-PH400 indoor pan/tilt head. ≥Use the AC adaptor (optional accessory) for the AW-RC400 cable compensation unit. ≥Use 10BASE-T straight cables to connect the IP/RP connectors on the pan/tilt heads with the CONTROL OUT TO PAN/TILT HEAD (1 to 5) connectors on the AW-RP400. The maximum extension distance is 500 meters when using UTP category 5 cables or their equivalent. ≥Use the camera cables supplied with the pan/tilt head to connect the AW-PH400 to the convertible camera. ≥Connect the iris control cable of the motorized zoom lens to the IRIS connector on the camera, and connect the zoom/focus cable to the LENS I/F connector on the pan/tilt head. ≥Use either the AW-CB400 remote operation panel or WV-CB700A remote control box for camera control. The AW-CB400 and WV-CB700A cannot be used together. ≥When using the AW-CB400, use the cable (10 m) supplied with the AW-CB400 to connect the CAMERA CONTROL IN FROM ROP connector on the AW-RP400 with the I/F CONNECTOR on the AW-CB400. Five cameras can be controlled from the AW-CB400. Power is supplied through this cable from the AW-RP400 to the AW-CB400 so the AC adaptor need not be connected to the AW-CB400. ≥When using the WV-CB700A, use the RCB cables (2 m) supplied with the WV-CB700A to connect the CAMERA CONTROL IN FROM RCB (1 to 5) connectors on the AW-RP400 with the RCB connectors on the WV-CB700A. Only one camera can be controlled from the WV-CB700A. If there is a multiple number of cameras, one AW-CB700A will be required for each camera. It is also necessary to align the number of the CONTROL OUT TO PAN/TILT HEAD connectors connected to the cameras to be controlled with the CAMERA CONTROL IN FROM RCB connectors used to connect the WV-CB700A. ≥Use the 10BASE-T straight cable to connect the MONI SEL OUT connector on the AW-RP400 with the MONI SEL IN connector on the AW-RC400. The maximum extension distance is 50 meters when using a UTP category 5 cable or its equivalent. By connecting these MONI SEL connectors, the video signals of the camera selected by the AW-RP400 can be output from the MONITOR1 connector and the video signals of the camera selected by the AW-CB400 can be output from the MONITOR2 connector. When the WV-CB700A is used, MONITOR2 cannot be switched. ≥Use a coaxial cable to connect the AW-RC400 and AW-PH400. ≥Supply the genlock signals from a unit such as a signal generator to the G/L IN connector on the AW-RC400, and connect the G/L OUT (1 to 5) connectors on the AW-RC400 with the G/L IN connectors on the pan/tilt heads. ≥When using composite signals, connect the VIDEO connectors on the pan/tilt heads and Y/VIDEO IN connectors (1 to 5) on the AW-RC400. Also connect the Y/VIDEO OUT connectors on the AW-RC400 to switchers or monitors. ≥When using Y/C signals, connect the Y connectors and Pr/C connectors on the pan/tilt heads to the Y/VIDEO IN connectors and Pr/C IN connectors, respectively, on the AW-RC400. Also connect the Y/VIDEO OUT connectors and Pr/C OUT connectors on the AW-RC400 to switchers or monitors. ≥When using component signals, connect the Y connector, Pr/C connector and Pb connector on the pan/tilt head to the Y/VIDEO IN connector, Pr/C IN connector and Pb IN connector, respectively, on the cable compensation unit. Also connect the Y/VIDEO OUT connectors, Pr/C OUT connectors and Pb OUT connectors on the AW-RC400 to switchers or monitors.
![](/img/blank.gif)
50 Connections Motorized zoom lens Iris control Convertible camera Genlock signals Video signals Video signal output Genlock signal input Monitor switching signals Monitor signals 1 Monitor for AW-CB400Monitor for AW-RP400 Monitor signals 2Camera cable supplied with AW-PH400 Zoom/focus control AW-PH400 Indoor Pan/Tilt Head Pan/tilt head/camera control signals AC power cable supplied with AW-PH400 AW-RP400 Pan/tilt control panel AW-CB400 Remote Operation Panel Cable supplied with AW-CB400 (AW-CB400 power and camera control signals)AW-RC400 Cable Compensation Unit AW-PS505 AC adaptorAW-PS301 AC adaptor