Pan/Tilt Control Panel AW-RP400 22 Introduction Accessories ≥This pan/tilt control panel enables up to five AW-PH400 indoor pan/tilt heads to be controlled. ≥By connecting the AW-CB400 remote operation panel or WV-CB700A remote control box to the control panel, the convertible cameras mounted on the pan/tilt heads can be controlled at the same time. ≥By installing an additional control panel, two of the five units in the pan/tilt head system can be controlled at the same time. ≥Up to ten tracing memories can be accommodated. ≥Up to 50 preset memories can be set. ≥The connection distance between the control panel and pan/tilt head system can be extended up to a maximum of 500 meters.NOTE ≥The AW-RP400 cannot be used to control the model AW-PH300, AW-PH300A, AW-PH350, AW-PH500 or AW-PH600 pan/tilt heads. ≥Before using the control panel, the movement range (limiters) of the pan/tilt head system must be set without fail. ≥When the AW-RP400 control panel is to be discarded at the end of its service life, ask a specialized contractor to dispose of it properly in order to protect the environment. Zoom switch ................................................................................. 1 Plug (D-SUB 15-pin) for tally/INCOM system ...................... 1 set Rack-mounting adaptors ............................................................. 2 Mounting screws (M4!8 mm) .................................................... 4
Pan/Tilt Control Panel AW-RP400 AW-RP400 23 Parts and their function 1EXT CONT [M/S] switch This switch is normally kept at the [M] (master) position. When an additional AW-RP400 control panel has been installed, set the EXT CONT switch on the additional unit to [S] (slave). If no additional AW-RP400 control panel is going to be installed, the EXT CONT switch on this control panel must be kept at the [M] (master) position without fail. 2OPERATE lamp This lights up green when the (3) OPERATE switch is at ON. It goes off when the switch is set to OFF. 3OPERATE [OFF/ON] switch When this switch is set to [ON], the power supply from the connected pan/tilt heads to the cameras is turned on, and system control is enabled. When it is set to [OFF], the power supply from the connected pan/tilt heads to the cameras is turned off. 4INCOM jack The INCOM (inter-communication) headset is connected here. 5LEVEL control Use this to adjust the volume of the headset’s receiver. 6CALL button When this button is pressed, the buzzer of the connected control panel sounds, and the CALL button lamp lights. 1 I H G E D C B A @ ? > = < ;F J K L 2 3 4 5 6 7 8 9 :$Front panel NOTE ≥The centering of the joystick and zoom switch is adjusted when the OPERATE switch has been set to [ON]. Therefore, do not touch the joystick or zoom switch while this switch is at the [ON] position. ≥When an additional AW-RP400 control panel is installed and used, it will not be possible to exercise control from the slave control panel unless the OPERATE switches not only on the slave control panel but on the master control panel as well are set to [ON]. Remember to set the OPERATE switch on the slave control panel to [ON] first before setting the OPERATE switch on the master control panel to [ON].
Pan/Tilt Control Panel AW-RP400 24 Parts and their function 7IRIS [AUTO/MANU/LOCK] button Use this to select the method for adjusting the lens iris of the cameras in the currently selected pan/tilt head system. Each time it is pressed, the setting is switched in the sequence of AUTO, MANU and LOCK. AUTO:The cameras automatically adjust the lens iris in accordance with the light quantity, and the IRIS button lamp lights. MANU:The lens iris is adjusted manually using the IRIS dial. At this setting, the IRIS button lamp is off. LOCK:The lens iris is locked at the manually adjusted setting. It does not move even when the (9) IRIS dial is turned. In this status, the IRIS button lamp flashes slowly. While MANU or LOCK is selected, the IRIS button lamp starts flashing quickly when the IRIS dial is turned: this indicates that the lens iris cannot be controlled even when the (9) IRIS dial is turned. ≥The IRIS button on the control panel does not work when the WV-CB700A remote control box is connected to the control panel. Select AUTO or MANU using the IRIS [AUTO/MAN] button on the WV-CB700A. 8SD CARD slot This slot is where the SD memory cards are inserted. The pan/tilt head and camera setting can be stored on these cards. 9IRIS dial The lens iris can be adjusted by turning this dial while the (7) IRIS [AUTO/MANU/LOCK] button is set to MANU. The iris is opened by turning the dial clockwise and stopped down by turning it counterclockwise. ≥The IRIS dial on the control panel does not work when the WV-CB700A remote control box is connected to the control panel. Adjust the iris using the IRIS control on the WV-CB700A. :ZOOM lever/FOCUS dial Use the ZOOM lever to adjust the lens zoom. The TELE (telephoto) and WIDE (wide angle) settings are established by the direction in which the lever is tilted; the zooming speed is adjusted by the angle to which the lever is tilted. The lens is focused using the FOCUS dial on the top of the lever. ;PAN POSITION indicator Sixteen LEDs are used to display the position of the pan/tilt head in the horizontal rotational direction for 200 degrees to the left or right. When the pan/tilt head is rotated to the right by more than 180 degrees up to 200 degrees, the 180-degree LED flashes, and LEDs on its left light. Conversely, when the pan/tilt head is rotated to the left by more than 180 degrees up to 200 degrees, the 180- degree LED flashes, and LEDs on its right light. OPEN). =ZOOM indicator The position of the lens zoom in the currently selected pan/tilt head system is indicated by a 6-step display (WIDE >TELE). >FOCUS indicator The position of the lens focus in the currently selected pan/tilt head system is indicated by a 6-step display (NEAR >FAR). ?OPTION switches [A to H] The “NOT USE”, “DEF”, “WIP”, “HEATER/FAN”, “LAMP”, “OPTION”, “ND”, “EXT” and “AF” functions can be allocated to OPTION switches A to H by menu settings. @HOME button Press this to move the pan/tilt head and roll unit to the home position. ALCD CONTRAST control Use this to adjust the contrast of the LCD panel. 0o 180°to the left or right 90°to the left 90°to the right
Pan/Tilt Control Panel AW-RP400 AW-RP400 25 Parts and their function BMEMORY button When one of the (C) PRESET MEMORY selection buttons [1] to [50] is pressed while holding down the MEMORY button, the settings of the pan/tilt head system can be registered in that PRESET MEMORY selection button. The MEMORY button flashes if the pan/tilt head selected by the (H) CONTROL SELECT button is not connected or its power has not been turned on. CPRESET MEMORY selection buttons [1] to [50] Use these buttons to call the settings registered in them. When data has been registered in the tracing memories, the recording/play time displays appear. DLCD panel The current setting statuses are displayed on this panel. EMENU/LIMIT button Hold down this button for two or more seconds to turn the setting menu ON or OFF. When (C) PRESET MEMORY selection button [5], [10], [15], [20], [25] or [30] is pressed while holding down the MENU/LIMIT button, ON/OFF control over the limiters can be exercised. FCONT dial This is used for the setting menu operations. GTALLY lamps [1] to [5] When tally signals are supplied to the (O) TALLY/INCOM connectors [1] to [5] on the rear panel, the lamps with the numbers corresponding to those connectors light up. When tally signals are supplied to the tally connectors [1] to [5] of the AW-CB400 remote operation panel, if this panel is connected to the pan/tilt control panel, the lamps with the numbers corresponding to those connectors also light up. HCONTROL SELECT buttons [1] to [5] The (R) CONTROL OUT TO PAN/TILT HEAD [P1] to [P5] connectors on the rear panel can be selected by pressing buttons [1] to [5]. The button lamps corresponding to the numbers of the buttons selected light, and the selected pan/tilt head systems can be controlled. When the (S) MONI SEL OUT connector on this control panel is connected to the MONI SEL IN connector on the AW-RC400 cable compensation unit, the images of the camera connected to the MONI1 or MONI2 connector on the AW-RC400 can be output. ≥When two AW-RP400 control panels are connected, the combination of the control panels which select the monitor output can be set on the menu. IANOTHER CONTROL lamps [1] to [5] When another AW-RP400 control panel is connected, these lamps indicate the numbers of the pan/tilt head systems selected by the additional AW-RP400 control panel. JTRACING MEMORY [START POINT, START, STOP, RESTORE, RESET, 1 to 10] buttons Use these for the tracing memory operations. For details on operation, refer to the tracing memory section. KSPEED controls [ZOOM/FOCUS/PAN/TILT/ROTATION] These enable the pan/tilt head, lens and roll unit control speeds to be adjusted. By turning these controls as far as they will go in the counterclockwise direction, operation of the pan/tilt heads and lenses can be prevented even when control is exercised using the joystick, etc. LPAN/TILT lever/ROTATION control switch Use these to adjust the direction of the pan/tilt heads. When the lever is tilted to the left or right, the pan/tilt heads move toward the left or right; when it is tilted up or down, they move upward or downward. The movement speed can be adjusted by the angle to which the lever is tilted. Further, the angle of the AW-RL400 roll unit can be adjusted using the ROTATION control switch on the front of the lever. By pressing the top part of the ROTATION control switch, the roll unit rotates clockwise; by pressing the bottom part, it rotates counterclockwise. The speed of the rotation changes in accordance with the amount of pressure applied.
Pan/Tilt Control Panel AW-RP400 26 Parts and their function MEXT CONT IN/OUT connectors When an additional AW-RP400 control panel is to be provided, connect these connectors on the two AW-RP400 control panels using a 10BASE-T (equivalent to UTP category 5) straight cable. NCAMERA CONTROL IN FROM RCB [P1] to [P5] connectors Connect the WV-CB700A remote control boxes to these connectors. The cameras installed on the pan/tilt heads corresponding to the ports where the WV-CB700A boxes have been connected can then be controlled. When even one WV-CB700A box is connected, the cameras cannot be controlled from the AW-CB400 remote operation panel even if the AW-CB400 is connected. OTALLY/INCOM connector Connect this to the TALLY/INCOM connector on the video switcher or other unit. When the TALLY input connector is set to the GND level, the TALLY lamp on the control panel or pan/tilt head lights. Do not apply a voltage in excess of 5V to this connector. Use the accessory plug (D-SUB 15-pin) to connect the tally/INCOM signals to the system. Connect a 4-wire INCOM system to the INCOM connector. When an additional control panel has been provided or when the AW-CB400 remote operation panel has been connected, the tally or INCOM function of all the units will take effect if tally or INCOM signals are connected to one of the units. MNOPQ U T S R $Rear panel Pin No. Signal name 1 TALLY1 9 TALLY2 2 TALLY3 10 TALLY4 3 TALLY5 11 TALLY GND 4 – – – 12 – – – 5 – – – 13 – – – 6 MIC+ 14 MIC– 7 INCOM GND 15 SP– 8 SP+ 87654321 ?>=
Pan/Tilt Control Panel AW-RP400 AW-RP400 27 Parts and their function PREMOTE connector Connect an external unit to this connector to control the pan/tilt head systems from a PC or other external unit. Connect the connector to the PC using the AW-CA50T9 RS-232C cable. QDC 12V IN socket Connect the AW-PS505 AC adaptor (sold separately) to this socket. RCONTROL OUT TO PAN/TILT HEAD [P1] to [P5] connectors Connect these connectors to the IP/RP connectors on the AW-PH400 indoor pan/tilt heads using 10BASE-T (equivalent to UTP category 5) straight cables. The cables can be extended up to a maximum of 500 meters. SMONI SEL OUT connector Connect this connector to the MONI SEL OUT connector on the AW-RC400 cable compensation unit using a 10BASE-T (equivalent to UTP category 5) straight cable. You can monitor the images of the system selected by the AW-RP400 from the MONITOR1 connector on the AW-RC400 and the images of the system selected by the AW-CB400 from the MONITOR2 connector on the AW-RC400. If two AW-RP400 units are connected, you can monitor the images of the system selected by the master AW-RP400 from the MONITOR1 connector on the AW-RC400 and the images of the system selected by the slave AW-RP400 from the MONITOR2 connector on the AW-RC400. TCAMERA CONTROL IN FROM ROP connector Connect the AW-CB400 remote operation panel to this connector using the connecting cable packed with the AW-CB400. The cameras installed on the pan/tilt heads can now be controlled from the AW-CB400. UGround terminal Connect this terminal to ground.
Pan/Tilt Control Panel AW-RP400 28 $Operation method 1The menu setting items are displayed when the MENU/LIMIT switch is held down for two or more seconds. 2If nothing appears on the bottom line of the LCD display, turn the CONT dial to select a menu item. 3When the CONT dial is pressed, what has been set appears on the bottom line. If more than one setting is involved in the menu item, the settings on the bottom line are switched each time the dial is pressed. 4When a setting is displayed, the setting can be changed by turning the CONT dial. 5Press the CONT dial successively: all the detailed settings come to an end, and the display on the bottom line is cleared, enabling another menu item to be selected. 6To exit the setting menu, hold down the MENU/LIMIT switch for two or more seconds. Even when a setting is displayed on the bottom line of the LCD display, the menu is exited when the MENU/LIMIT switch is held down for two or more seconds.; ; ; ; ; ; ; AW-RP400 P/T CONTROL PANEL DIRECTION DIRECTION TILT REVERSE DIRECTION TILT NORMAL DIRECTION PAN NORMAL DIRECTION SET PRIORITY AW-RP400 P/T CONTROL PANEL Menu settings
Pan/Tilt Control Panel AW-RP400 AW-RP400 29 Menu settings $List of menu items and settings PRIORITY MASTER, SLAVE MASTER DIRECTION PAN TILT ZOOM NORMAL, REVERSE NORMAL FOCUS IRIS ROTATION TILT RANGE 190°, 300° 190° SPEED WITH ZOOM POS. OFF, 1, 2, 3 OFF MEMORY LENGTH 60s, 120s, 300s, 600s 60s PRESET SPEED 1 to 25 25 IRIS CONTROL BOTH, RP400, CB400 BOTH ROTATION SWITCH ROTATION, FOCUS, ZOOM, IRIS ROTATION OPTION SWITCH A B C D NOT USE, DEF, WIP, HEATER/FAN, NOT USE E LAMP, OPTION, ND, EXT, AF F G H CONTROL SELECT MODE INTERLOCK, UN-INTERLOCK INTERLOCK BUZZER OFF, ON ON AUTO RUN START No. 1 to 50 1 END No. 1 to 50 50 INTERVAL 1s to 30s 1s OPERATE STOP, RUN STOP SD CARD STORE, LOAD – – –Menu item Setting Description Initial value PRIORITY (MASTER/SLAVE) When two AW-RP400 pan/tilt control panels have been connected, the priority of the CONTROL SELECT buttons is to be set. When MASTER is selected as the setting, the master AW-RP400 has priority; when SLAVE is selected, the slave AW-RP400 has priority. If the AW-RP400 control panel with a high priority has selected the pan/tilt heads, which were selected by the AW-RP400 control panel with a low priority, the CONTROL SELECT button lamps on the AW-RP400 control panel with the low priority start flashing to indicate that the control rights have been ceded to the other control panel. This setting is performed using the master AW-RP400 control panel.
Pan/Tilt Control Panel AW-RP400 30 Menu settings DIRECTION settings (PAN, TILT, ZOOM, FOCUS, IRIS, ROTATION: NORMAL/REVERSE) When the lever or dial is operated, the DIRECTION menu item enables the operational direction of PAN, TILT, ZOOM, FOCUS, IRIS or ROTATION to be set as the user desires. PAN:When NORMAL is selected, the pan/tilt head moves toward the left when the PAN/TILT lever is tilted to the LEFT and toward the right when it is tilted to the RIGHT. When REVERSE is selected, the head moves in the opposite direction. TILT:When NORMAL is selected, the pan/tilt head moves upward when the PAN/TILT lever is tilted toward UP and down when it is tilted toward DOWN. When REVERSE is selected, the head moves in the opposite direction. ZOOM:When NORMAL is selected, the lens zoom moves toward the telephoto end when the ZOOM lever is tilted toward TELE and toward the wide-angle end when it is tilted toward WIDE. When REVERSE is selected, the zoom moves in the opposite direction. FOCUS:When NORMAL is selected, the lens focus moves toward FAR when the FOCUS dial is turned clockwise and toward NEAR when it is turned counterclockwise. When REVERSE is selected, the lens focus moves in the opposite direction. IRIS:When NORMAL is selected, the lens iris moves toward open when the IRIS dial is turned clockwise and toward closed when it is turned counterclockwise. When REVERSE is selected, the lens iris moves in the opposite direction. ROTATION:When NORMAL is selected, the pan/tilt head moves clockwise when the top of the ROTATION control switch is pressed and counterclockwise when the bottom is pressed. When REVERSE is selected, the head moves in the opposite direction. TILT RANGE setting (190/300 degrees) This menu item is used to set the tilting range of the AW-PH400. Normally, the 190 degrees setting is used. SPEED WITH ZOOM POS. setting (OFF/1/2/3) At the OFF setting, the pan and tilt speed does not change in accordance with the zoom position. At the 1, 2 or 3 setting, the panning and tilting of the pan/tilt head slows down as the zoom approaches the telephoto end, making it easier to adjust the pan or tilt position even at the telephoto end. The higher the number selected for the setting, the slower the pan and tilt speed at the telephoto end, and the easier it is to adjust the position using a zoom lens with a high magnification rate. PRESET SPEED setting (1 to 25) During preset memory data play, this menu item enables the movement speed to the preset positions to be set to one of 25 steps. The higher the setting, the faster the movement speed to the preset positions; conversely, the lower the setting, the slower the movement speed. IRIS CONTROL setting (BOTH/RP400/CB400) When the AW-CB400 remote operation panel has been connected to the AW-RP400 control panel, this menu item is used to set which control panel is to be used to adjust the lens iris. At the BOTH setting, the lens iris can be controlled from both the AW-RP400 and AW-CB400. At the RP400 setting, it can be controlled only from the AW-RP400; similarly, at the CB400 setting, it can be controlled only from the AW-CB400. ROTATION SWITCH setting (ROTATION/FOCUS/ZOOM/IRIS) This menu item enables ROTATION, FOCUS, ZOOM or IRIS to be selected as the function to be controlled by the ROTATION switch.