    Have a look at the manual Panasonic Indoor Pan Tilt Head Aw Ph360n Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							- 31 -
    Connections
    5When the camera and pan/tilt head are to be controlled by the AW-RP505 control panel
    for transmitting component signals
    • Use the supplied camera cable to connect the unit with the convertible camera.
    • Set controller selection switch SW1 to the right side (RP501), and select the transmission
    signal selection setting that supports the analog/IEEE1394 card.
    • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP
    connector with the multiport hub’s PAN/TILT CONTROL OUT connector.
    • Use a coaxial cable (BELDEN 8281) to connect the unit’s CAMERA CONTROL IN connector
    with the multiport hub’s CAMERA CONTROL OUT connector.
    • Use a 10BASE-T straight cable (UTP category 5) to connect the multiport hub’s PAN/TILT
    CONTROL IN connector with the controller’s PAN/TILT CONTROL OUT connector.
    • Use a coaxial cable (BELDEN 8281) to connect the multiport hub’s CAMERA CONTROL IN
    connector with the controller’s CAMERA CONTROL OUT connector.
    • Use coaxial cables to connect the unit’s Y OUT connector, Pr/SDI OUT connector and Pb
    OUT connector with the component input connectors on the color monitor.
    • Check that the pan/tilt head and camera can be controlled by the controller.
    • Transmitting component signals over a long distance requires a separate cable
    compensation unit.
    Multiport hub:
    AW-HB505 AC adapter: 
    AW-PS300AColor monitor Camera cable
    (supplied)
    10BASE-T (equivalent
    to UTP category 5)
    straight cable, max.
    33 ft. (10 m)
    10BASE-T
    (equivalent to
    UTP category
    5) straight
    cable, max.
    1640 ft. (500 m)
    Coaxial cable (BELDEN 8281),
    max. 1640 ft. (500 m
    )
    Coaxial
    cable
    (BELDEN
    8281), max.
    33 ft. (10 m
    )
    Coaxial cable
    Genlock signals must be supplied if
    a multiple number of cameras and
    pan/tilt heads are to be used.
    Multi hybrid control panel:AW-RP505
    DC cable
    (UL Type SPT-2 2!16 AWG
    or UL Type NISPT-2 2!16
    AWG, to be locally
    purchased) 
    						
    							- 32 -
    Connections
    6When the camera and pan/tilt head are to be controlled by the AW-RP505 control panel
    for transmitting SDI signals
    • Use the supplied camera cable to connect the unit with the convertible camera containing the
    plugged-in SDI card (such as the AW-PB504N).
    • Use a coaxial cable to connect the SDI card’s SDI OUT connector with the unit’s SDI IN
    connector. Adjust the cable to a length at which the pan/tilt head will move smoothly.
    • Set controller selection switch SW1 to the right side (RP501), and select the transmission signal
    selection setting that supports the SDI card.
    • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP
    connector with the multiport hub’s PAN/TILT CONTROL OUT connector.
    • Use a coaxial cable (BELDEN 8281) to connect the unit’s CAMERA CONTROL IN connector with
    the multiport hub’s CAMERA CONTROL OUT connector.
    • Use a 10BASE-T straight cable (UTP category 5) to connect the multiport hub’s PAN/TILT
    CONTROL IN connector with the controller’s PAN/TILT CONTROL OUT connector.
    • Use a coaxial cable (BELDEN 8281) to connect the multiport hub’s CAMERA CONTROL IN
    connector with the controller’s CAMERA CONTROL OUT connector.
    • Use a coaxial cable to connect the unit’s Pr/SDI OUT connector with the color monitor’s SDI input
    connector.
    • Check that the pan/tilt head and camera can be controlled by the controller.
    Genlock signals must be supplied if
    a multiple number of cameras and
    pan/tilt heads are to be used.
    Multiport hub:
    AW-HB505 AC adapter: 
    AW-PS300AColor monitor
    Coaxial cable
    (BELDEN 8281),
    max. 666 ft. (200 m
    )
    10BASE-T
    (equivalent to
    UTP category
    5) straight
    cable, max.
    1640 ft. (500 m)
    Coaxial cable (BELDEN 8281),
    max. 1640 ft. (500 m
    )
    Coaxial
    cable
    (BELDEN
    8281), max.
    33 ft. (10 m
    )
    10BASE-T (equivalent
    to UTP category 5)
    straight cable, max.
    33 ft. (10 m) Camera cable
    (supplied) Coaxial cable
    Multi hybrid control panel:AW-RP505
    DC cable
    (UL Type SPT-2 2!16 AWG
    or UL Type NISPT-2 2!16
    AWG, to be locally
    purchased) 
    						
    							- 33 -
    Connections
    7When the camera and pan/tilt head are to be controlled by the AW-RP605A 
    multi-function controller for transmitting composite or component signals
    • Use the supplied camera cable to connect the unit with the convertible camera.
    • Set controller selection switch SW1 to the left side (RP605), and select the transmission signal
    selection setting that supports the analog/IEEE1394 card.
    • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP
    connector with the controller’s CONTROL OUT TO PAN/TILT HEAD connector.
    • Use a coaxial cable (BELDEN 8281) to connect the unit’s VIDEO OUT connector with the
    controller’s VIDEO/Y IN connector (when composite signals are to be transmitted).
    • Use a coaxial cable (BELDEN 8281) to connect the unit’s Y OUT connector, Pr/SDI OUT
    connector and Pb OUT connector with the controller’s VIDEO/Y IN connector, Pr IN connector
    and Pb IN connector (when component signals are to be transmitted).
    • Use a coaxial cable to connect the controller’s VIDEO/Y OUT connector, Pr OUT connector and
    Pb OUT connector with the color monitor’s VIDEO input connector or component input
    connectors.
    • Check that the pan/tilt head and camera can be controlled by the controller.
    Multi-function controller:AW-RP605A AC adapter: 
    AW-PS300AColor monitor Camera cable
    (supplied)
    Coaxial cable
    (BELDEN 8281), max.
    3333 ft. (1000 m
    )
    10BASE-T (equivalent to
    UTP category 5) straight
    cable, max. 3333 ft. (1000 m)Coaxial cable
    Genlock signals must be supplied if
    a multiple number of cameras and
    pan/tilt heads are to be used.
    DC cable
    (UL Type SPT-2 2!16 AWG or
    UL Type NISPT-2 2!16 AWG,
    to be locally purchased) 
    						
    							- 34 -
    Connections
    8When the camera and pan/tilt head are to be controlled by the AW-RP605A 
    multi-function controller for transmitting SDI signals
    • Use the supplied camera cable to connect the unit with the convertible camera
    containing the plugged-in SDI card (such as the AW-PB504N).
    • Use a coaxial cable to connect the SDI card’s SDI OUT connector with the unit’s SDI
    IN connector. Adjust the cable to a length at which the pan/tilt head will move
    smoothly.
    • Set controller selection switch SW1 to the left side (RP605), and select the
    transmission signal selection setting that supports the SDI card.
    • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN
    IP/RP connector with the controller’s CONTROL OUT TO PAN/TILT HEAD connector.
    • Use a coaxial cable to connect the unit’s Pr/SDI OUT connector with the color
    monitor’s SDI input connector.
    • Check that the pan/tilt head and camera can be controlled by the controller.
    Multi-function controller:AW-RP605A AC adapter: 
    AW-PS300AColor monitor Coaxial cable
    (BELDEN 8281), max.
    666 ft. (200 m
    )
    Coaxial cable
    (BELDEN 8281), max.
    3333 ft. (1000 m
    )
    10BASE-T (equivalent to
    UTP category 5) straight
    cable, max. 3333 ft. (1000 m)
    Genlock signals must be supplied if
    a multiple number of cameras and
    pan/tilt heads are to be used.
    Camera cable
    (supplied) Coaxial cable
    DC cable
    (UL Type SPT-2 2!16 AWG or
    UL Type NISPT-2 2!16 AWG,
    to be locally purchased) 
    						
    							- 35 -
    Connections
    9When the pan/tilt head is to be controlled by the AW-RP400 pan/tilt head control panel
    for transmitting composite or component signals (and the AW-CB400 remote operation
    panel is used to control the camera)
    • Use the supplied camera cable to connect the unit with the convertible camera.
    • Set controller selection switch SW1 to the right side (RP501), and select the transmission signal
    selection setting that supports the analog/IEEE1394 card.
    • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP
    connector with the controller’s CONTROL OUT TO PAN/TILT HEAD connector.
    • Use a coaxial cable (BELDEN 8281) to connect the unit’s VIDEO OUT connector with the cable
    compensation unit’s Y VIDEO IN connector (when composite signals are to be transmitted).
    • Use a coaxial cable (BELDEN 8281) to connect the unit’s Y OUT connector, Pr/SDI OUT
    connector and Pb OUT connector with the cable compensation unit’s Y VIDEO IN connector, PR
    C IN connector and PB IN connector (when component signals are to be transmitted).
    • 
    Use a coaxial cable to connect the cable compensation unit’s Y VIDEO IN connector, PR C IN connector
    and PB IN connector with the color monitor’s VIDEO input connector or component input connectors.
    • Use the cable supplied with the remote operation panel to connect the controller’s CAMERA
    CONTROL IN FROM ROP connector with the remote operation panel’s CONTROL OUT TO
    CONTROL PANEL connector.
    • Check that the pan/tilt head and camera can be controlled by the controller.
    Cable compensation unit:
    AW-RC400
    AC adapter: 
    AW-PS300A
    Color monitor Camera cable
    (supplied)
    10BASE-T (equivalent to
    UTP category 5) straight
    cable, max. 1640 ft. (500 m)
    Coaxial cable (BELDEN 8281),
    max. 1640 ft. (500 m
    )
    Coaxial cable
    Genlock signals must be supplied if
    a multiple number of cameras and
    pan/tilt heads are to be used.
    Pan/tilt control panel:
    AW-RP400 Remote operation
    panel:
    AW-CB400Cable supplied
    with AW-CB400
    DC cable
    (UL Type SPT-2 2!16 AWG or
    UL Type NISPT-2 2!16 AWG,
    to be locally purchased) 
    						
    							- 36 -
    Connections
    :When the pan/tilt head is to be controlled by the AW-RP400 pan/tilt head control panel
    for transmitting SDI signals (and the AW-CB400 remote operation panel is used to
    control the camera)
    • Use the supplied camera cable to connect the unit with the convertible camera
    containing the plugged-in SDI card (such as the AW-PB504N).
    • Use a coaxial cable to connect the SDI card’s SDI OUT connector with the unit’s SDI
    IN connector. Adjust the cable to a length at which the pan/tilt head will move
    smoothly.
    • Set controller selection switch SW1 to the right side (RP501), and select the
    transmission signal selection setting that supports the SDI card.
    • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN
    IP/RP connector with the controller’s CONTROL OUT TO PAN/TILT HEAD connector.
    • Use a coaxial cable to connect the unit’s Pr/SDI OUT connector with the color
    monitor’s SDI input connector.
    • Use the cable supplied with the remote operation panel to connect the controller’s
    CAMERA CONTROL IN FROM ROP connector with the remote operation panel’s
    CONTROL OUT TO CONTROL PANEL connector.
    • Check that the pan/tilt head and camera can be controlled by the controller.
    AC adapter: 
    AW-PS300AColor monitor Coaxial cable
    (BELDEN 8281), max.
    666 ft. (200 m
    )10BASE-T (equivalent to UTP
    category 5) straight cable,
    max. 1640 ft. (500 m)Camera cable
    (supplied) Coaxial cable
    Pan/tilt control panel:
    AW-RP400Remote operation
    panel:
    AW-CB400
    Cable supplied
    with AW-CB400
    DC cable
    (UL Type SPT-2 2!16 AWG or
    UL Type NISPT-2 2!16 AWG,
    to be locally purchased) 
    						
    							- 37 -
    Connections
    ;When the pan/tilt head is to be controlled by the AW-RP400 pan/tilt head control panel
    for transmitting composite or component signals (and the WV-CB700A remote control
    box is used to control the camera)
    • Use the supplied camera cable to connect the unit with the convertible camera.
    • Set controller selection switch SW1 to the right side (RP501), and select the transmission signal
    selection setting that supports the analog/IEEE1394 card.
    • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP
    connector with the controller’s CONTROL OUT TO PAN/TILT HEAD connector.
    • Use a coaxial cable (BELDEN 8281) to connect the unit’s VIDEO OUT connector with the cable
    compensation unit’s Y VIDEO IN connector (when composite signals are to be transmitted).
    • Use a coaxial cable (BELDEN 8281) to connect the unit’s Y OUT connector, Pr/SDI OUT
    connector and Pb OUT connector with the cable compensation unit’s Y VIDEO IN connector, PR
    C IN connector and PB IN connector (when component signals are to be transmitted).
    • Use a coaxial cable to connect the cable compensation unit’s Y VIDEO IN connector, PR C IN
    connector and PB IN connector with the color monitor’s VIDEO input connector or component
    input connectors.
    • Use the cable supplied with the remote control box to connect the controller’s CAMERA
    CONTROL IN FROM RCB connector with the remote control box’s RCB connector.
    • Check that the pan/tilt head and camera can be controlled by the controller.
    AC adapter: AW-PS300AColor monitor Camera cable
    (supplied)
    Coaxial cable (BELDEN 8281),
    max. 1640 ft. (500 m
    )
    10BASE-T (equivalent to UTP
    category 5) straight cable,
    max. 1640 ft. (500 m)
    Coaxial cable Pan/tilt control panel:
    AW-RP400Remote control box:
    WV-CB700A Cable supplied
    with WV-CB700A
    Genlock signals must be supplied if
    a multiple number of cameras and
    pan/tilt heads are to be used.
    Cable compensation unit:
    AW-RC400
    DC cable
    (UL Type SPT-2 2!16 AWG or
    UL Type NISPT-2 2!16 AWG,
    to be locally purchased) 
    						
    							- 39 -
    Connections
    =When the camera and pan/tilt head are to be controlled by a personal computer or other
    such unit
    • Use the supplied camera cable to connect the unit with the convertible camera.
    • Set controller selection switch SW1 to the right side (RP501), and select the
    transmission signal selection setting that supports the analog/IEEE1394 card.
    • Use the RS-232C cable (AW-CA28T9) to connect the personal computer or other such
    unit with the unit’s CONTROL IN RS-232C connector.
    • Use coaxial cables to connect the unit’s VIDEO OUT connector or Y OUT connector,
    Pr/SDI OUT connector and Pb OUT connector with the color monitor’s VIDEO input
    connector or component input connectors.
    • Check that the pan/tilt head and camera can be controlled by the controller.
    • Transmitting video signals over a long distance requires a separate cable
    compensation unit.
    ❈When SDI signals are to be transmitted, plug the SDI card (such as the AW-PB504N)
    into the convertible camera, connect the SDI card’s SDI OUT connector with the unit’s
    SDI IN connector using a coaxial cable, and select the transmission signal selection
    setting that supports the SDI card. Then use another coaxial cable to connect the
    unit’s Pr/SDI OUT connector with the color monitor’s SDI input connector.
    Personal computer
    (Windows) AC adapter: 
    AW-PS300AColor monitor Camera cable
    (supplied)
    RS-232C cable: AW-CA28T9
    • The BNC connectors are not
    connected to the pan/tilt head.
    • When using RS-232C for
    control, the maximum length
    of the RS-232C cable is 
    50 ft. (15 m). To further extend
    the cable length, convert 
    RS-232C to RS-422 and
    convert it back to RS-232C at
    the pan/tilt head side.
    Coaxial cable
    DC cable
    (UL Type SPT-2 2!16 AWG or
    UL Type NISPT-2 2!16 AWG,
    to be locally purchased) 
    						
    							- 40 -
    Connections
    >When the camera and pan/tilt head are to be controlled by both the AW-RP501
    controller and a personal computer
    • Use the supplied camera cable to connect the unit with the convertible camera.
    • Set controller selection switch SW1 to the right side (RP501), and select the transmission signal
    selection setting that supports the analog/IEEE1394 card.
    • Follow connection example 1to connect the unit and AW-RP501 controller. However, when
    using a personal computer or other such unit to control the camera, leave the unit’s CAMERA
    CONTROL IN connector unconnected.
    • Use the RS-232C cable (AW-CA28T9) to connect the personal computer or other such unit with
    the unit’s CONTROL IN RS-232C connector.
    • 
    Check that the pan/tilt head and camera can be controlled using the controller and personal computer
    or other such unit. However, the camera can be controlled solely by the controller if the unit’s CAMERA
    CONTROL IN connector and controller’s CAMERA CONTROL OUT connector are connected and
    solely by the personal computer or other such unit if these two connectors are not connected.
    ❈When SDI signals are to be transmitted, plug the SDI card (such as the AW-PB504N) into the
    convertible camera, connect the SDI card’s SDI OUT connector with the unit’s SDI IN connector
    using a coaxial cable, and select the transmission signal selection setting that supports the SDI
    card. Then use another coaxial cable to connect the unit’s Pr/SDI OUT connector with the color
    monitor’s SDI input connector.
    Hybrid control panel:
    AW-RP501 AC adapter: 
    AW-PS300AColor monitor Camera cable
    (supplied)
    10BASE-T (equivalent to UTP category 5)
    straight cable, max. 1640 ft. (500 m) Coaxial cable
    (BELDEN 8281), max.
    1640 ft. (500 m
    )
    Coaxial cablePersonal computer
    (Windows) RS-232C cable: AW-CA28T9
    • The BNC connectors are not
    connected to the pan/tilt head.
    • When using RS-232C for
    control, the maximum length
    of the RS-232C cable is 
    50 ft. (15 m). To further extend
    the cable length, convert 
    RS-232C to RS-422 and
    convert it back to RS-232C at
    the pan/tilt head side.
    DC cable
    (UL Type SPT-2 2!16 AWG or
    UL Type NISPT-2 2!16 AWG,
    to be locally purchased) 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Indoor Pan Tilt Head Aw Ph360n Operating Instructions