Have a look at the manual Panasonic Indoor Pan Tilt Head Aw Ph360n Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
![](/img/blank.gif)
- 21 - Connections $Connecting the connector panel(with the controller AW-RP400) Zoom lens Base connector front panel AC adapter: AW-PS505A AC adapter: AW-PS505A AW-RC400 Cable compensation unit AW-RP400 Pan/tilt control panel AW-CB400 Remote operation panel Cable supplied with AW-CB400 (AW-CB400 power and camera control signals) Convertible camera AC adapter: AW-PS300A Monitor switching signals Monitor signals 1 Monitor for AW-CB400Monitor for AW-RP400 Monitor signals 2Camera cable (supplied) 10BASE-T (equivalent to UTP category 5) straight cable 10BASE-T (equivalent to UTP category 5) straight cableCoaxial cable (BELDEN 8281) Coaxial cable (BELDEN 8281) Coaxial cableCoaxial cable Video signal out G/L signal out DC cable (UL Type SPT-2 2!16 AWG or UL Type NISPT-2 2!16 AWG, to be locally purchased)
![](/img/blank.gif)
- 22 - Connections $Connecting the connector panel(RS-232C control) Zoom lens Personal computer Base connector front panelConvertible camera AC adapter: AW-PS300A MonitorCamera cable (supplied) RS-232C cable: AW-CA28T9 • The BNC connectors are not connected to the pan/tilt head. • When using RS-232C for control, the maximum length of the RS-232C cable is 50 ft. (15 m). To further extend the cable length, convert RS-232C to RS-422 and convert it back to RS-232C at the pan/tilt head side. Coaxial cable (BELDEN 8281) ❈When the coaxial cable for VIDEO ;is to be run over a long distance, use a cable compensation unit immediately before the monitor input. DC cable (UL Type SPT-2 2!16 AWG or UL Type NISPT-2 2!16 AWG, to be locally purchased)
![](/img/blank.gif)
- 23 - Connections $Head connector panel The camera and lens control cables are connected to this panel. 1ND/EXT connector This is for controlling the ND filter and lens extender of the power lens unit. Connect it when using a power lens unit equipped with an ND filter and lens extender function. 2LENS I/F connector This is for controlling the zoom/focus functions of the power lens unit. Connect the remote (zoom/focus) control cable of the power lens unit here. 3SDI IN connector This is for SDI signal input. Using a coaxial cable (BELDEN 8281), connect this with the SDI OUT connector of an SDI card (AW-PB504N, etc.) installed in the convertible camera. 4CAMERA I/F connector This is for convertible camera control. Connect this to the I/F REMOTE connector on the camera with the supplied camera cable. (As viewed from cable end) ND signal ND returnCVCC (+15V) CGND EXT return EXT signal
![](/img/blank.gif)
- 24 - Connections 51394 connector This is for controlling the convertible camera, in which an IEEE 1394 card has been installed, and the pan/tilt head. As the connecting cable, use an IEEE 1394 cable. OThis unit cannot be controlled directly using an IEEE1394 card. A convertible camera containing the plugged-in IEEE1394 card is needed. 6CONTROL IN IP/RP connector This is for camera/pan/tilt head control signals. Connect this to the PAN/TILT CONTROL OUT connector on the controllers AW-RP301/AW-RP305/ AW-RP501/AW-RP505, or multiport hub AW-HB505, CONTROL OUT TO PAN/TILT HEAD connector on the controller AW-RP605A, or CONTROL OUT TO PAN/TILT connector on the controller AW-RP400. Use a 10BASE-T straight cable (UTP category 5) for the connecting cable. ODepending on the controller to be used, it may be necessary to change the switch positions. For details on how to do this, refer to the section on “Controller selection switch settings” under “Installation” (page 10).OFor your safety, connect to an Ethernet network which does not exceed the voltage limit of the Ethernet connector. 7Y OUT connector This is for camera video signal output. Connect this to the Y IN connector on the controller or to a monitor, etc. Use a coaxial cable (BELDEN 8281) for the connecting cable. 8Pr/SDI OUT connector This is for camera video signal output. Connect this to the Pr IN connector on the controller or to a monitor, etc. SDI signals can be output when an SDI card (AW-PB504N, etc.) is installed in the convertible camera for use. Use a coaxial cable (BELDEN 8281) for the connecting cable. OTo switch from Pr to SDI or vice versa, it is necessary to change the switch positions. For details on how to do this, refer to the section on “Transmission signal selection setting” under “Installation” (page 11). $Connecting the base connector rear panel and the base connector front panel Pin No. Signal 1 DC 12V 2 GND 3 TPB 2 4 TPB 5 TPA 2 6 TPA
![](/img/blank.gif)
- 25 - 9Pb OUT connector This is for camera video signal output. Connect this to the Pb IN connector on the controller or to a monitor, etc. Use a coaxial cable (BELDEN 8281) for the connecting cable. :G/L IN connector This is for genlock signal input. Connect this to the G/L OUT connector on the controller. Use a coaxial cable (BELDEN 8281) for the connecting cable. ;VIDEO OUT connector This is for camera video signal output. Connect this to the VIDEO IN connector on the controller or to a monitor, etc. Use a coaxial cable (BELDEN 8281) for the connecting cable.
![](/img/blank.gif)
- 26 - Connections $Connecting the AC adapter for use with the pan/tilt head Connect the pan/tilt head with the AW-PS300A AC adapter designed for use with the pan/tilt head. Standard bare end length 11 mm It is recommended that the tip be soldered. AC adapter for use with the pan/tilt head: AW-PS300A >DC 12V IN terminal board Connect this to the DC 15V OUT connector on the AC adapter (AW-PS300A). (The voltage output from the AC adapter is set to 15V: this takes into consideration the voltage drops due to the possible extension of the DC cable between the pan/tilt head and AC adapter.) Make sure that the positive +and negative -ends of the wires are connected to the same signs on the connector. Use a cable with a nominal cross section of 1.25 mm 2or more that meets the UL specifications for the connection. The maximum allowable cable length is 98.4 ft. (30 meters). Applicable (usable) wire UL Type SPT-2 2!16 AWG or UL Type NISPT-2 2!16 AWG ?LAMP CONTROL terminal board Connect this only when the power of a halogen lamp is to be supplied from the AC adapter (AW-PS300A). This connector is connected to LAMPCONTROL on the AC adapter for the pan/tilt head. The symbols C and S on the wires must match the same symbols on the connector. Use a cable with a nominal cross section of 0.3 mm 2or more that meets the UL specifications for the connection. The maximum allowable cable length is 98.4 ft. (30 meters). @OP terminal board Connect this only when the OP SW CONTROL OUT connector on the AC adapter (AW-PS300A) is to be used. Connect it to the OPTION SW CONTROL IN connector on the AC adapter (AW-PS300A). Use a cable with a nominal cross section of 0.3 mm 2or more that meets the UL specifications for the connection. The maximum allowable cable length is 98.4 ft. (30 meters).
![](/img/blank.gif)
- 27 - Connections $Connection examples 1When the camera and pan/tilt head are to be controlled by the AW-RP501 control panel for transmitting composite signals • Use the supplied camera cable to connect the unit with the convertible camera. • Set controller selection switch SW1 to the right side (RP501), and select the transmission signal selection setting that supports the analog/IEEE1394 card. • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP connector with the controller’s PAN TILT CONTROL OUT connector. • Use a coaxial cable (BELDEN 8281) to connect the unit’s CAMERA CONTROL IN connector with the controller’s CAMERA CONTROL OUT connector. • Use a coaxial cable (BELDEN 8281) to connect the unit’s VIDEO OUT connector with the controller’s VIDEO IN connector. • Use a coaxial cable to connect the controller’s VIDEO OUT connector with the color monitor’s VIDEO input connector. • Check that the pan/tilt head and camera can be controlled by the controller. Hybrid control panel: AW-RP501 AC adapter: AW-PS300AColor monitor Camera cable (supplied) Coaxial cable (BELDEN 8281), max. 1640 ft. (500 m ) 10BASE-T (equivalent to UTP category 5) straight cable, max. 1640 ft. (500 m ) Coaxial cable DC cable (UL Type SPT-2 2!16 AWG or UL Type NISPT-2 2!16 AWG, to be locally purchased)
![](/img/blank.gif)
- 28 - Connections 2When the camera and pan/tilt head are to be controlled by the AW-RP501 control panel for transmitting component signals • Use the supplied camera cable to connect the unit with the convertible camera. • Set controller selection switch SW1 to the right side (RP501), and select the transmission signal selection setting that supports the analog/IEEE1394 card. • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP connector with the controller’s PAN TILT CONTROL OUT connector. • Use a coaxial cable (BELDEN 8281) to connect the unit’s CAMERA CONTROL IN connector with the controller’s CAMERA CONTROL OUT connector. • Use coaxial cables to connect the unit’s Y OUT connector, Pr/SDI OUT connector and Pb OUT connector with the component input connectors on the color monitor. • Check that the pan/tilt head and camera can be controlled by the controller. • Transmitting component signals over a long distance requires a separate cable compensation unit. Hybrid control panel: AW-RP501 AC adapter: AW-PS300AColor monitor Camera cable (supplied) Coaxial cable (BELDEN 8281), max. 1640 ft. (500 m ) 10BASE-T (equivalent to UTP category 5) straight cable, max. 1640 ft. (500 m ) Coaxial cable DC cable (UL Type SPT-2 2!16 AWG or UL Type NISPT-2 2!16 AWG, to be locally purchased)
![](/img/blank.gif)
- 29 - Connections 3When the camera and pan/tilt head are to be controlled by the AW-RP501 control panel for transmitting SDI signals • Use the supplied camera cable to connect the unit with the convertible camera containing the plugged-in SDI card (such as the AW-PB504N). • Use a coaxial cable to connect the SDI card’s SDI OUT connector with the unit’s SDI IN connector. Adjust the cable to a length at which the pan/tilt head will move smoothly. • Set controller selection switch SW1 to the right side (RP501), and select the transmission signal selection setting that supports the SDI card. • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP connector with the controller’s PAN TILT CONTROL OUT connector. • Use a coaxial cable (BELDEN 8281) to connect the unit’s CAMERA CONTROL IN connector with the controller’s CAMERA CONTROL OUT connector. • Use a coaxial cable to connect the unit’s Pr/SDI OUT connector with the color monitor’s SDI input connector. • Check that the pan/tilt head and camera can be controlled by the controller. Hybrid control panel: AW-RP501 AC adapter: AW-PS300AColor monitor Camera cable (supplied) Coaxial cable Coaxial cable (BELDEN 8281), max. 666 ft. (200 m ) Coaxial cable (BELDEN 8281), max. 1640 ft. (500 m) 10BASE-T (equivalent to UTP category 5) straight cable, max. 1640 ft. (500 m) DC cable (UL Type SPT-2 2!16 AWG or UL Type NISPT-2 2!16 AWG, to be locally purchased)
![](/img/blank.gif)
- 30 - Connections 4When the camera and pan/tilt head are to be controlled by the AW-RP505 control panel for transmitting composite signals • Use the supplied camera cable to connect the unit with the convertible camera. • Set controller selection switch SW1 to the right side (RP501), and select the transmission signal selection setting that supports the analog/IEEE1394 card. • Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP connector with the multiport hub’s PAN/TILT CONTROL OUT connector. • Use a coaxial cable (BELDEN 8281) to connect the unit’s CAMERA CONTROL IN connector with the multiport hub’s CAMERA CONTROL OUT connector. • Use a coaxial cable (BELDEN 8281) to connect the unit’s VIDEO OUT connector with the multiport hub’s VIDEO IN connector. • Use a 10BASE-T straight cable (UTP category 5) to connect the multiport hub’s PAN/TILT CONTROL IN connector with the controller’s PAN/TILT CONTROL OUT connector. • Use a coaxial cable (BELDEN 8281) to connect the multiport hub’s CAMERA CONTROL IN connector with the controller’s CAMERA CONTROL OUT connector. • Use a coaxial cable (BELDEN 8281) to connect the multiport hub’s PREVIEW OUT connector with the controller’s PREVIEW IN connector. • Connect the multiport hub’s VIDEO OUT connector to the color monitor’s VIDEO input connector. • Check that the pan/tilt head and camera can be controlled by the controller. Genlock signals must be supplied if a multiple number of cameras and pan/tilt heads are to be used. Multi hybrid control panel:AW-RP505 Multiport hub: AW-HB505 AC adapter: AW-PS300APreview color monitor Color monitor Camera cable (supplied) Coaxial cable (BELDEN 8281), max. 33 ft. (10 m ) Coaxial cable (BELDEN 8281), max. 1640 ft. (500 m) Coaxial cable 10BASE-T (equivalent to UTP category 5) straight cable, max. 33 ft. (10 m) 10BASE-T (equivalent to UTP category 5) straight cable, max. 1640 ft. (500 m) DC cable (UL Type SPT-2 2!16 AWG or UL Type NISPT-2 2!16 AWG, to be locally purchased)