Page 11
Installation The main unit is installed on a wall, and the probe unit can be installed on a wall or a floor. When the metal probes on the probe unit come in to contact with water, a small amount of electrical charge flows between the probes, which the main unit recognizes as a water leak. Probe unit installed on wall Probe unit installed on floor Installation precautions R The sensor is not designed to be used in situations that require high reliability. We do not recommend use of the sensor in these...
Page 12
R Install the probe unit so that the metal probes are horizontal. A water leak can on ly be detected if water touches both of the metal probes; if water touches only one of the probes, a water leak will not be detected. Correct installation Incorrect installation Metal probes are horizontal to the fl o or Metal probes are not horizontal to th e floor Installation location In s tall the water leak sensor in a basement, kitchen, utility room, or anywhere you want to detect a water leak. Common...
Page 13
Securing with the wall mounting adaptors 1 Use screws to attach the wall mounting adaptors to the wall. n Main unit Screws 75 mm (2 15/16 inches) n Pr obe unit Screw Note: R To install the probe unit on a floor, see page 16. In this case, you will not use the probe unit’s wall mounting adaptor. For assistance, please visit www.panasonic.com/support 13 Setup )/4@ FO@FO @@WFSQEG 1 2 1 2 1 1 1
Page 14
2 Remove the backing from the double-sided tape, insert the main unit and the pr obe unit into the wall mounting adaptors, and then press firmly on each unit to ensure solid adhesion to the installation surface. Double-sided tape 14 For assistance, please visit www.panasonic.com/supportSetup )/4@ FO@FO @@WFSQEG 3 3 3 3
Page 15
Securing with double-sided tape only Not e: R Make sure any surfaces that will make contact with the double-sided tape are clean and dry before applying the tape. When attaching the double-sided tape to concrete or bricks, if the surface of the concrete or bricks is wet, make sure to completely dry the surface before attaching the double-sided tape. 1 Remove the backing from the double-sided tape, attach the main unit and the probe unit to the installation surface, and then press firmly on each unit to...
Page 16
Installing the probe unit on a floor Whe n installing the probe unit on a floor, use the double-sided tape to attach the probe unit directly to the floor. Note: R If the probe unit is inserted into the wall mounting adaptor and attached to a floor, the probes will be too far from the floor and therefore water leaks can only be detected after the leaked water has become deep enough to touch the probes. Correct installation Incorrect installation Shallow water touches probes Only deep water can touch...
Page 17
Removing from the wall n Re moving from the wall mounting adaptors 1 Insert a flat screwdriver into the notches on the wall mounting adaptors, and carefully pry away the main unit and probe unit. 2 Remove the screws that secure the wall mounting adaptors to the wall. n R emoving when secured with double-sided tape only 1 Tie a piece of thread to two sticks, screwdrivers, etc. 2 Pull the thread tight and use it to cut the double-sided tape, and then remove any excess tape. Excess tape For assistance,...
Page 18
Testing the sensor You can check the sensor’s LED indicator and test the performance of the sensor. 1 Remove the main unit cover. 2 Press M N . 3 Tou ch the probes of the probe unit to water. 4 Confirm that the LED indicator lights in red. 5 Press M N again. Features available wh e n using the [Home Network] app Some of the sensor’s features that are available when using the [Home Network] app are listed below. For more information, refer to the User’s Guide (page 18). – Alarm system You can use...
Page 19
Specifications R Sta ndards DECT 6.0 (Digital Enhanced Cordless Telecommunications 6.0) R Frequency range DECT: 1.92 GHz – 1.93 GHz R RF transmission power DECT: 115 mW (max.) R Power source Lithium battery CR2 (1 ´ 3.0 V, 850 mAh) R Operating conditions 0 °C – 40 °C (32 °F – 104 °F) R Battery life Approx. 2 years (when the sensor is triggered once a month, in an environment of 25 °C (77 °F)) R Dimensions Main unit (height ´ width ´ depth) (not including double-sided tape): Approx. 106 mm ´ 31 mm ´...
Page 20
FCC and other inf ormation This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Privacy of communications may not be ensured when using this device. CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to...