Home
>
Panasonic
>
Wireless Network
>
Panasonic Home Network System Water Leak Sensor Kx Hns103 Installation Guide
Panasonic Home Network System Water Leak Sensor Kx Hns103 Installation Guide
Have a look at the manual Panasonic Home Network System Water Leak Sensor Kx Hns103 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Installation The main unit is installed on a wall, and the probe unit can be installed on a wall or a floor. When the metal probes on the probe unit come in to contact with water, a small amount of electrical charge flows between the probes, which the main unit recognizes as a water leak. Probe unit installed on wall Probe unit installed on floor Installation precautions R The sensor is not designed to be used in situations that require high reliability. We do not recommend use of the sensor in these situations. R Panasonic takes no responsibility for any injury or damage caused by the use of this product. R When installing, make sure the battery is inserted properly and the main unit cover is completely closed. R When installing on a wooden surface, use the included wall mounting adaptors. Secure the wall mounting adaptors to the wall using screws (not double-sided tape). R Mount the sensor on the stable location where the sensor can be adequately supported when mounting. R Do not mount the sensor on a soft material. It may fall down, break or cause injury. R Do not mount the sensor on the following places: gypsum board, ALC (autoclaved lightweight cellular concrete), concrete block, plywood less than 25.4 mm (1 inch) thick, etc. R The sensor may not be able to properly detect a water leak if the water contains contaminants such as oil, or if the water is frozen (i.e., ice or snow). For assistance, please visit www.panasonic.com/support 11 Setup )/4@ FO@FO @@WFSQEG
R Install the probe unit so that the metal probes are horizontal. A water leak can on ly be detected if water touches both of the metal probes; if water touches only one of the probes, a water leak will not be detected. Correct installation Incorrect installation Metal probes are horizontal to the fl o or Metal probes are not horizontal to th e floor Installation location In s tall the water leak sensor in a basement, kitchen, utility room, or anywhere you want to detect a water leak. Common installation examples include near a washing machine, hot water heater, or a location where a water leak has occurred in the past. Note: R Install the probe unit so that its metal probes are about 1 mm (1/32 inches) above the floor. If the probes touch the floor, the sensor may make false detections. If the probes are too far from the floor, water leaks can only be detected after the leaked water has become deep enough to touch the probes. R Install the main unit 1 m (3 feet 3 inches) or higher above the floor. The main unit is not waterproof; if it becomes wet, the sensor may become damaged and water leaks will not be detected properly. 12 For assistance, please visit www.panasonic.com/supportSetup )/4@ FO@FO @@WFSQEG
Securing with the wall mounting adaptors 1 Use screws to attach the wall mounting adaptors to the wall. n Main unit Screws 75 mm (2 15/16 inches) n Pr obe unit Screw Note: R To install the probe unit on a floor, see page 16. In this case, you will not use the probe unit’s wall mounting adaptor. For assistance, please visit www.panasonic.com/support 13 Setup )/4@ FO@FO @@WFSQEG 1 2 1 2 1 1 1
2 Remove the backing from the double-sided tape, insert the main unit and the pr obe unit into the wall mounting adaptors, and then press firmly on each unit to ensure solid adhesion to the installation surface. Double-sided tape 14 For assistance, please visit www.panasonic.com/supportSetup )/4@ FO@FO @@WFSQEG 3 3 3 3
Securing with double-sided tape only Not e: R Make sure any surfaces that will make contact with the double-sided tape are clean and dry before applying the tape. When attaching the double-sided tape to concrete or bricks, if the surface of the concrete or bricks is wet, make sure to completely dry the surface before attaching the double-sided tape. 1 Remove the backing from the double-sided tape, attach the main unit and the probe unit to the installation surface, and then press firmly on each unit to ensure solid adhesion to the installation surface. Double-sided tape Note: R To install the probe unit on a floor, see page 16. For assistance, please visit www.panasonic.com/support 15 Setup )/4@ FO@FO @@WFSQEG 1 1 1 1
Installing the probe unit on a floor Whe n installing the probe unit on a floor, use the double-sided tape to attach the probe unit directly to the floor. Note: R If the probe unit is inserted into the wall mounting adaptor and attached to a floor, the probes will be too far from the floor and therefore water leaks can only be detected after the leaked water has become deep enough to touch the probes. Correct installation Incorrect installation Shallow water touches probes Only deep water can touch probes A Wall mounting adaptor 16 For assistance, please visit www.panasonic.com/supportSetup )/4@ FO@FO @@WFSQEG A
Removing from the wall n Re moving from the wall mounting adaptors 1 Insert a flat screwdriver into the notches on the wall mounting adaptors, and carefully pry away the main unit and probe unit. 2 Remove the screws that secure the wall mounting adaptors to the wall. n R emoving when secured with double-sided tape only 1 Tie a piece of thread to two sticks, screwdrivers, etc. 2 Pull the thread tight and use it to cut the double-sided tape, and then remove any excess tape. Excess tape For assistance, please visit www.panasonic.com/support 17 Setup )/4@ FO@FO @@WFSQEG 1 1
Testing the sensor You can check the sensor’s LED indicator and test the performance of the sensor. 1 Remove the main unit cover. 2 Press M N . 3 Tou ch the probes of the probe unit to water. 4 Confirm that the LED indicator lights in red. 5 Press M N again. Features available wh e n using the [Home Network] app Some of the sensor’s features that are available when using the [Home Network] app are listed below. For more information, refer to the User’s Guide (page 18). – Alarm system You can use the app to arm and disarm the alarm system, confirm the current status of the sensor, and view a log of previous events. – Sensor integration You can configure the sensor to trigger other system events, such as camera recording, turning on an electric device (such as a lamp), etc. (Appropriate device required.) – Telephone alert You can configure the system to call a preprogrammed phone number when the sensor is triggered. Accessing the User’s Gui de The User’s Guide is a collection of online documentation that helps you get the most out of the [Home Network] app. 1 iPhone ® /iPad ® Tap in the app’s home screen. A nd roid ™ devices Tap or press your mobile de v ice’s menu button in the app’s home screen. 2 Tap [User’s Guide] . Note: R Microsoft ® Windows ® Internet Explorer ® 8 and earlier versions are not supported. R Android 4.1 or later versions are recommended. R You can also access the User’s Guide at the web page listed below. www.panasonic.net/pcc/support/tel/ hom enetwork/manual/ 18 For assistance, please visit www.panasonic.com/supportAppendix )/4@ FO@FO @@WFSQEG
Specifications R Sta ndards DECT 6.0 (Digital Enhanced Cordless Telecommunications 6.0) R Frequency range DECT: 1.92 GHz – 1.93 GHz R RF transmission power DECT: 115 mW (max.) R Power source Lithium battery CR2 (1 ´ 3.0 V, 850 mAh) R Operating conditions 0 °C – 40 °C (32 °F – 104 °F) R Battery life Approx. 2 years (when the sensor is triggered once a month, in an environment of 25 °C (77 °F)) R Dimensions Main unit (height ´ width ´ depth) (not including double-sided tape): Approx. 106 mm ´ 31 mm ´ 22 mm (4 5/32 inches ´ 1 7/32 inches ´ 7/8 inches) Probe unit (height ´ width ´ depth) (not including double-sided tape): Approx. 44 mm ´ 24 mm ´ 10 mm (1 23/32 inches ´ 15/16 inches ´ 3/8 inches) Cable (length): Approx. 1.2 m (3 feet 11 inches) R Mass (weight) Approx. 80 g (0.18 lb), excluding the battery For assistance, please visit www.panasonic.com/support 19 Appendix )/4@ FO@FO @@WFSQEG
FCC and other inf ormation This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Privacy of communications may not be ensured when using this device. CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this device. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the fo l lowing measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. Some devices operate at frequencies that may cause interference to nearby TVs and VCRs. To minimize or prevent such interference, the devices should not be placed near or on top of a TV or VCR. If interference is experienced, move this device away from the TV or VCR. This will often reduce or eliminate interference. FCC RF Exposure Warning: R This product complies with FCC radiation exposure limits set forth for an uncontrolled environment. R To comply with FCC RF exposure requirements, the device must be installed and operated 20 cm (8 inches) or more between the product and all person’s body. R This product may not be collocated or operated in conjunction with any other antenna or transmitter. R For body-worn operation, the device must be used only with a non-metallic accessory. Use of other accessories may not ensure compliance with FCC RF exposure requirements. Notice: R FCC ID can be found inside the main unit. 20 For assistance, please visit www.panasonic.com/supportAppendix )/4@ FO@FO @@WFSQEG