Have a look at the manual Panasonic Digital Disk Recorders Wj Hd500a Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
53 • “FPS” indicates as field per second or frame per second when the FIELD/FRAME parameter is set to FIELD or FRAME in the menu. Move the cursor to the REC QUALITY parameter by pressing the Dor Cbutton, then select a recording image quality by pressing the +or -button. SUPER FINE:For enhanced sharpness (Compression Rate 1/6) FINE:For fine image quality (Compression Rate 1/10) NORMAL:For normal image quality (Compression Rate 1/16) EXTENDED:For extended time recording quality (Compression Rate 1/25) Alarm Active Mode The item lets you select the active mode for group cameras in Time Lapse Recording when an alarm is received while recording with the internal programmed timer. 1. Move the cursor to the TRIGGER ACTION parameter in the menu by pressing the Dor Cbutton. 2. Select the desired active mode for assigned group cameras by pressing the +or -button. REC+ALM:Enables alarm recording and alarm activa- tion. REC:Enables only alarm recording. The ALARM display on the monitor is disabled. OFF:Deactivates alarm input. The ALARM display on the monitor is also disabled. The factory default setting is REC+ALM. Event Recording These items let you set the recording mode in Time Lapse Recording when an alarm is received during the recording with the internal programmed timer. 1. Move the cursor to the EVENT REC MODE parameter by pressing the Dor Cbutton, then select a recording time mode by pressing the +or -button. The parameters are the same as TIMER REC MODE except OFF. For details refer to TIMER REC MODE in this menu. 2. Move the cursor to the REC RATE(MAX) parameter by pressing the Dor Cbutton, then select a recording rate by pressing the +or -button. For details refer to REC RATE in this menu. 3. Move the cursor to the REC QUALITY parameter by pressing the Dor Cbutton, then select a recording image quality by pressing the +or -button. For details refer to REC QUALITY in this menu.4. Move the cursor to the DURATION parameter by press- ing the Dor Cbutton, then select the alarm recording duration by pressing the +or -button. 2S - 6M:Enables alarm recording for between 2 sec- onds and 6 minutes. MANUAL:Enables alarm recording while the alarm sig- nal is received from the ALARM port. CONTINUE:Enables alarm recording until the REC STOP is pressed. The factory default setting is 10S. 5. Move the cursor to the DYNAMIC REC parameter by pressing the Dor Cbutton, then select an alarm recording pattern by pressing the +or -button. OFF:Records the images assigned to the group inputs including the one which has activated the alarm. ALM-PRI:Records the alarm input images preferential- ly over other video inputs. ALM-ONLY:Records the particular images that have activated the alarm. ALM-MILUTI:Records multiple alarms adaptively. The factory default setting is OFF. 6. If the parameter ALM-MULTI is selected for alarm recording pattern, move the cursor to the REC RATE(BASE) parameter by pressing the Dor Cbutton, then select a recording rate by pressing the +or - button. The recording rate can be selected as same as REC RATE(MAX) maximally. 7. Move the cursor to the AUTO COPY parameter by pressing the Dor Cbutton, then select alarm backup mode by pressing the +or -button. This lets you enable or disable alarm data backup on the DVD-RAM disk. Refer to the DVD DRIVE SETUP for details. OFF:Disables alarm data backup. ON:Enables alarm data backup. The factory default setting is OFF. 8. Press the SETUP/ESCbutton to return to the previous program number menu.
54 Multi Shot Recording (Internal Timer) As described before, the Multi Shot Recording is an event recording function reacting to an alarm input. It records the number of images in pre- and post-recording. Pre-recording is the recorded images during standby, prior to the input of the alarm signal. Post-recording is the recorded images after the input of the alarm signal. These items let you determine the recording parameters for Multi Shot Recording assigned in the program number menu. (continued from Program Timer) 1. Select the recording mode M/S in the program number menu by pressing the +or -button, then press the SETbutton. The selected Multi Shot Recording menu as shown below appears on the monitor screen. 2. Move the cursor to the TRIGGER ACTION parameter in the menu by pressing the Dor Cbutton, then select an active mode for group cameras when an alarm is received by pressing the +or -button. REC+ALM:Enables alarm recording and alarm activa- tion. REC:Enables only alarm recording. The ALARM display on the monitor is also disabled. The factory default setting is REC+ALM. 3. Move the cursor to the REC RATE parameter in the menu by pressing the Dor Cbutton, then select the desired recording rate by pressing the +or -button. 1 - 60FPS:Records the selected number of freeze images every second. 0.5FPS:Records a freeze image every 2 seconds. 0.4FPS:Records a freeze image every 2.5 seconds. 0.3FPS:Records a freeze image every 3.3 seconds. 0.2FPS:Records a freeze image every 5 seconds. 0.1FPS:Records a freeze image every 10 seconds. The factory default setting is 15FPS.Notes: • The maximum recording rate depends on the selected parameters in the COMMON SETUP menu as shown in the table. FIELD/FRAME CAMERA GENLOCK REC RATE FIELD ON 60FPS OFF 30FPS FRAME 3DIM ON 10FPS ON OFF 10FPS FRAME 3DIM ON 30FPS OFF OFF 15FPS • “FPS” indicates as field per second or frame per second when the FIELD/FRAME parameter is set to FIELD or FRAME in the menu. 4. Move the cursor to the REC QUALITY parameter by pressing the Dor Cbutton, then select a recording image quality by pressing the +or -button. SUPER FINE:For enhanced sharpness (Compression Rate 1/6) FINE:For fine image quality (Compression Rate 1/10) NORMAL:For normal image quality (Compression Rate 1/16) EXTENDED:For extended recording quality (Compres- sion Rate 1/25) The factory default setting is SUPER FINE. 5. Move the cursor to the PRE PICTURES parameter by pressing the Dor Cbutton, then select a number of the pre-recording image by pressing the +or -but- ton. 0:Disables pre-recording. 4 to maximum:Sets the number of images for pre- recording. • The maximum number of the pre-recording is deter- mined by the setting of FIELD/FRAME and REC QUALI- TY. The factory default setting is 15. The value that appears underneath the number of pre- recording images indicates the number of images to be recorded per assigned group camera (number of pre- recording images divided by number of the assigned group cameras). 6. Move the cursor to the POST PICTURES parameter by pressing the Dor Cbutton, then select a number of the post-recording image by pressing the +or -but- ton. 4 to 200:Sets the number of images for post-recording. The factory default setting is 60. 3-1-1-1 PROG1-NO1-G1 REC SETUP M/S(EVENT:MULTI SHOT) TRIGGER ACTION REC+ALM REC MODE REC RATE 15FPS REC QUALITY SUPER FINE PRE PICTURES 15 XXX.X/CAM POST PICTURES 60 DYNAMIC REC OFF AUTO COPY OFF
55 7. Move the cursor to the DYNAMIC REC parameter by pressing the Dor Cbutton, then select the recording pattern for post-recording by pressing the +or -but- ton. OFF:Records the images assigned to group inputs, including the one that has activated the alarm (the same as pre-recording). ALM-ONLY:Records the particular image that has acti- vated the alarm. The factory default setting is OFF. 8. Move the cursor to the AUTO COPY parameter by pressing the Dor Cbutton, then select alarm backup mode by pressing the +or -button. OFF:Disables alarm data backup. ON:Enables alarm data backup. The factory default setting is OFF. 9. Press the SETUP/ESCbutton to return to the previous program number menu. One Shot Recording (Internal Timer) As described before, the One Shot Recording is an event recording function reacting to an alarm input. It records the number of particular images that have acti- vated the alarm. These items let you determine the recording parameters for One Shot Recording assigned in the program number menu. (continued from Program Timer) 1. Select the recording mode O/S in the program number menu by pressing the +or -button, then press the SETbutton. The selected One Shot Recording menu as shown below appears on the monitor screen. 2. Move the cursor to the TRIGGER ACTION parameter in the menu by pressing the Dor Cbutton, then select an active mode for group cameras when an alarm is received by pressing the +or -button. REC+ALM:Enables alarm recording and alarm activa- tion. REC:Enables only alarm recording. The ALARM display on the monitor is also disabled. The factory default setting is REC+ALM.3. Move the cursor to the REC RATE parameter in the menu by pressing the Dor Cbutton, then select the desired recording rate by pressing the +or -button. 1 - 60FPS:Records the selected number of the freeze image per second. The factory default setting is 15FPS. Notes: • The maximum recording rate depends on the selected parameters in the COMMON SETUP menu as shown in the table. FIELD/FRAME CAMERA GENLOCK REC RATE FIELD ON 60FPS OFF 30FPS FRAME 3DIM ON 10FPS ON OFF 10FPS FRAME 3DIM ON 30FPS OFF OFF 15FPS • “FPS” indicates as field per second or frame per second when the FIELD/FRAME parameter is set to FIELD or FRAME in the menu. 4. Move the cursor to the REC QUALITY parameter by pressing the Dor Cbutton, then select the desired image quality by pressing the +or -button. SUPER FINE:For enhanced sharpness (Compression Rate 1/6) FINE:For fine image quality (Compression Rate 1/10) NORMAL:For normal image quality (Compression Rate 1/16) EXTENDED:For extended time recording quality (Compression Rate 1/25) The factory default setting is SUPER FINE. 5. Move the cursor to the PICTURE parameter by pressing the Dor Cbutton, then select the number of freeze images to be recorded by pressing the +or -button. 4 to 60:Records the selected number of freeze images for One Shot Recording. The factory default setting is 16. 6. Move the cursor to the AUTO COPY parameter by pressing the Dor Cbutton, then select an alarm back- up mode by pressing the +or -button. OFF:Disables backup for alarm recording. ON:Enables backup for alarm recording. The factory default setting is OFF. 7. Press the SETUP/ESCbutton to return to the previous program number menu. 3-1-1-1 PROG1-NO1-G1 REC SETUP O/S(EVENT:ONE SHOT) TRIGGER ACTION REC+ALM REC MODE REC RATE 15FPS REC QUALITY SUPER FINE PICTURES 16 AUTO COPY OFF
56 Emergency Recording (Time Lapse Recording) The Emergency Recording is given priority to record all video inputs in Time Lapse Recording reacting to a signal input form the CONTROL port. These items let you determine the recording parameters for Time Lapse Recording when the input signal is received from pin 21 of the CONTROL port located on the rear of the Disk Recorder. 1. Move the cursor to EMERGENCY in the WJ-HD500 SETUP menu by pressing the Dor Cbutton. 2. Select either audio recording function by pressing the +or -button, then press the SETbutton. The selected EMERGENCY REC SETUP menu shown below appears on the monitor screen. 3. Move the cursor to the EMERGENCY REC MODE para- meter in the menu by pressing the Dor Cbutton, then select the desired recording time mode by pressing the +or -button. SF-✽✽H or SF-A*✽✽H:Selects the recording time mode in enhanced fine quality. FQ-✽✽H or FQ-A*✽✽H:Selects the recording time mode in fine quality. NQ-✽✽H or NQ-A*✽✽H:Selects the recording time mode in normal quality. EX-✽✽H or EX-A*✽✽H:Selects the recording time mode in extended time quality. SP or SP-A*:Freely selectable ✽✽indicates the hours for recording time mode: 2, 12, 18, 24, 48, 72, 96, 120, 180, 240, 360, 480, 720, 960, 1200, 1440, 2160, 2880, 3600, 4320, 6480, 8640 (parameter A* indicates recording with audio) When the parameter SF/FQ/NQ/EX is selected for recording time, the recording rate and quality are auto- matically set according to the selected recording time. Note:It may not be possible to set the recording time, depending on the remaining storage capacity of the hard disk. The factory default setting is SF-24H.4. If the parameter SP is selected for the recording time, move the cursor to the REC RATE parameter by press- ing the Dor Cbutton, then select the desired record- ing rate by pressing the +or -button. 1 - 60FPS:Records the selected number of freeze images every second. 0.5FPS:Records a freeze image every 2 seconds. 0.4FPS:Records a freeze image every 2.5 seconds. 0.3FPS:Records a freeze image every 3.3 seconds. 0.2FPS:Records a freeze image every 5 seconds. 0.1FPS:Records a freeze image every 10 seconds. Notes: • The maximum recording rate depends on the selected parameters in the COMMON SETUP menu as shown in the table. FIELD/FRAME CAMERA GENLOCK REC RATE FIELD ON 60FPS OFF 30FPS FRAME 3DIM ON 10FPS ON OFF 10FPS FRAME 3DIM ON 30FPS OFF OFF 15FPS • “FPS” indicates as field per second or frame per second when the FIELD/FRAME parameter is set to FIELD or FRAME in the menu. Move the cursor to the REC QUALITY parameter by pressing the Dor Cbutton, then select a recording image quality by pressing the +or -button. SUPER FINE:For enhanced sharpness (Compression Rate 1/6) FINE:For fine image quality (Compression Rate 1/10) NORMAL:For normal image quality (Compression Rate 1/16) EXTENDED:For extended time recording quality (Compression Rate 1/25) 5. Move the cursor to the DURATION parameter by press- ing the Dor Cbutton, then select the recording dura- tion by pressing the +or -button. 2S - 6M:Enables recording for between 2 seconds and 6 minutes. MANUAL:Enables recording while the input signal is received from the CONTROL port. CONTINUE:Enables recording until the REC STOP but- ton is pressed. The factory default setting is 10S. 6. Press the SETUP/ESCbutton to return to the previous WJ-HD500 SETUP menu. 4 EMERGENCY REC SETUP(WITHOUT AUDIO) EMERGENCY REC MODE SF- 24H REC RATE 7.5FPS REC QUALITY SUPER FINE DURATION 10S
57 Sequence Setup (Multiscreen Monitor) There are three sequence patterns to run on the Multiscreen Monitor. The items shown below let you program the sequence to run on the Multiscreen Monitor. Live Sequence Live sequence is a series of 16 steps assigned to the Multiscreen Monitor. The sequence steps can be combined with four screen segments (quad) display. Live Sequence Pattern Setting 1. Move the cursor to MULTI LIVE SEQUENCE SETUP in the SEQUENCE SETUP menu by pressing the Dor C button, then press the SETbutton. The menu shown below appears on the monitor screen. 2. Move the cursor to the step editing area by pressing the A, B, Dor Cbutton. 3. Select a camera to be displayed for CAM editing area by pressing the +or -button. 1 - 16:Displays the image of the selected camera num- ber. 4A - 4D:Displays the assigned images in quad. Refer to the QUAD PATTERN SETUP for settings. --:Disables display and will skip automatically. 4. Move the cursor to the PRESET editing area by press- ing the Bbutton, then select a preset position to be displayed by pressing the +or -button, if applica- ble. 1 - 64:Selects a preset position of the assigned cam- era. --:No preset position The factory default setting is --. These items let you determine functions such as sequence and power on status for this Disk Recorder. 1. Select MULTIPLEXER SETUP in the WJ-HD500 SETUP menu by pressing the Dor Cbutton, then press the SETbutton. The MULTIPLEXER SETUP menu as shown below appears on the monitor screen. 2. Select an item or item parameter in the menu by press- ing the Dor Cbutton. 3. To return to the WJ-HD500 SETUP menu, press the SETUP/ESCbutton. Sequence Setup These items let you program the sequence pattern for the Spot and Multiscreen Monitor. 1. Move the cursor to SEQUENCE SETUP in the MULTI- PLEXER SETUP menu by pressing the Dor Cbutton, then press the SETbutton. The SEQUENCE SETUP menu as shown below appears on the monitor screen. 2. Select an item or item parameter in the SEQUENCE SETUP menu by pressing the Dor Cbutton. 3. To return to the previous MULTIPLEXER SETUP menu, press the SETUP/ESCbutton. 5 MULTIPLEXER SETUP SEQUENCE SETUP POWER ON MULTI OUTPUT QUAD-4A SPOT OUTPUT 1 SECRET VIEW OFF 5-1 SEQUENCE SETUP MULTI LIVE SEQUENCE SETUP QUAD SHIFT OFF QUAD PATTERN SETUP SEQ TIMING INT GROUP SEQ MODE QUAD SEQ DWELL 2S AUTO SKIP ON SPOT LIVE SEQUENCE SETUP SEQ TIMING INT AUTO SKIP ON 5-1-1 MULTI LIVE SEQUENCE SETUP PRE- PRE- STEP CAM SET SEC STEP CAM SET SEC 1 4A -- 2S 9 -- -- 0S 2 4B -- 2S 10 -- -- 0S 3 4C -- 2S 11 -- -- 0S 4 4D -- 2S 12 -- -- 0S 5 -- -- 0S 13 -- -- 0S 6 -- -- 0S 14 -- -- 0S 7 -- -- 0S 15 -- -- 0S 8 -- -- 0S 16 -- -- 0S MULTIPLEXER SETUP
58 2. Move the cursor to the editing area to assign a camera by pressing the A, B, Dor Cbutton. 3. Select a camera number to be assigned by pressing the +or -button. AREA indicates the display pattern, including the cam- era assignment and display positions as shown below. 4. Repeat the above steps 2 and 3 to assign a camera for other areas. 5. When satisfied with all of the above steps, press the SETUP/ESCbutton to return to the previous SEQUENCE SETUP menu. Sequence Timing Setting This item lets you select between internal and external con- trol for advancing the sequence on the Multiscreen Monitor. 1. Move the cursor to the SEQ TIMING parameter in the SEQUENCE SETUP menu by pressing the Dor Cbut- ton. 2. Select either INT or EXT by pressing the +or -but- ton. INT:Advances a sequence by the Dwell Time that was programmed on the MULTI LIVE SEQUENCE SETUP. EXT:Advances a sequence by the input from pin 5 of the ALARM port. The factory default setting is INT. Note:To assign the parameters 1 - 64, the specified combination cameras are equipped in the system with a PS •Data* mode. 5. Move the cursor to the SEC editing area by pressing the Bbutton, then select the desired dwell time by pressing the +or -button. 0S:The step will not be displayed on the monitor. 1S - 30S:Selects a dwell time between 1 second and 30 seconds. 6. Repeat the above steps 2 to 5 to program the other steps. 7. When satisfied with all of the above steps, press the SETUP/ESCbutton to return to the previous SEQUENCE SETUP menu. Quad Shift Setting This item lets you enable or disable the quad shift operation when the MULTISCREEN SELECT button is pressed. Quad shift displays an image series such as 4A, 4B, 4C and 4D previously programmed on four screen segments. 1. Move the cursor to the QUAD SHIFT parameter in the SEQUENCE SETUP menu by pressing the Dor Cbut- ton. 2. Select either ON or OFF by pressing the +or -but- ton. ON:Enables the quad shift operation. OFF:Disables the quad shift operation. The initial factory setting is OFF. Quad Pattern Setup This item lets you select the pattern to be displayed on the Multiscreen Monitor when a 4-segment (Quad) display is selected in spot or sequence. The camera images can be assigned to the segments as shown below. 1. Move the cursor to QUAD PATTERN SETUP in the SEQUENCE SETUP menu by pressing the Dor Cbut- ton, then press the SETbutton. The menu shown below appears on the monitor screen. 5-1-2 MULTI QUAD PATTERN SETUP AREA CAM AREA CAM 4A-1 1 4C-1 9 4A-2 2 4C-2 10 4A-3 3 4C-3 11 4A-4 4 4C-4 12 4B-1 5 4D-1 13 4B-2 6 4D-2 14 4B-3 7 4D-3 15 4B-4 8 4D-4 16 4A-1 4A-34A-2 4A-4
59 Sequence Setup (Spot Monitor) This item lets you program the live sequence pattern to be run on the Spot Monitor. Live sequence is a series of 16 steps assigned to the Spot Monitor. This sequence can be run on the Multiscreen Monitor by operating the buttons. Live Sequence Pattern Setting 1. Move the cursor to SPOT LIVE SEQUENCE SETUP in the SEQUENCE SETUP menu by pressing the Dor C button, then press the SETbutton. The menu shown below appears on the monitor screen. 2. Move the cursor to the step editing area by pressing the A, B, Dor Cbutton. 3. Select a camera number to be displayed for the CAM editing area by pressing the +or -button. 1 - 16:Displays the image of the selected camera num- ber. --:Disables the display and will skip automatically. 4. Move the cursor to the PRESET editing area by press- ing the Bbutton, then select a preset position to be displayed by pressing the +or -button, if applica- ble. 1 - 64:Selects a preset position of the assigned cam- era. --:No preset position The factory default setting is --. Note:To assign the parameters 1 - 64, the specified combination cameras are equipped in the system with a PS •Data* mode. 5. Move the cursor to SEC editing area by pressing the B button, then select the desired dwell time by pressing the +or -button. 0S:The step will not be displayed on the monitor. 1S - 30S:Selects the dwell time between 1 second and 30 seconds. The factory default setting is 2S. Group Multi Sequence Setting As described before, the cameras are assigned to 4 groups for recording with a programmed internal timer. This item lets you select the sequence pattern to be dis- played of each group on the Multiscreen Monitor. Group Multi Sequence Pattern Setting 1. Move the cursor to the GROUP SEQ MODE parameter in the SEQUENCE SETUP by pressing the Dor Cbut- ton. 2. Select either QUAD or MULTI GROUP display mode to be run on the monitor by pressing the +or -button. MULTI GROUP:Camera images are displayed in sequence with the minimum quantities of the seg- ment screen. QUAD:Camera images are displayed with a 4-segment screen in sequence. The factory default setting is QUAD. Dwell Time Setting 1. Move the cursor to the SEQ DWELL parameter in the SEQUENCE SETUP by pressing the Dor Cbutton. 2. Select the desired dwell time for the group sequence by pressing the +or -button. 1S - 30S:Selects the dwell time between 1 second and 30 seconds. The factory default setting is 2S. Auto Skip Setting This item lets you enable or disable the auto skip function on the Multiscreen Monitor to skip any steps when no video signal is present. 1. Move the cursor to the AUTO SKIP parameter in the SEQUENCE SETUP by pressing the Dor Cbutton. 2. Select either ON or OFF by pressing the +or -but- ton. ON:Enables the auto skip function on the Multiscreen Monitor. OFF:Disables the auto skip function on the Multiscreen Monitor. The factory default setting is ON. 5-1-3 SPOT LIVE SEQUENCE SETUP PRE- PRE- STEP CAM SET SEC STEP CAM SET SEC 1 1 -- 2S 9 9 -- 2S 2 2 -- 2S 10 10 -- 2S 3 3 -- 2S 11 11 -- 2S 4 4 -- 2S 12 12 -- 2S 5 5 -- 2S 13 13 -- 2S 6 6 -- 2S 14 14 -- 2S 7 7 -- 2S 15 15 -- 2S 8 8 -- 2S 16 16 -- 2S
60 6. Repeat the above steps 2 to 5 to set up the other steps. 7. When satisfied with all of the above steps, press the SETUP/ESC button to return to the previous SEQUENCE SETUP menu. Sequence Timing Setting This item lets you select between internal and external con- trol for advancing the sequence on the Spot Monitor. 1. Move the cursor to the SEQ TIMING parameter in the SEQUENCE SETUP menu by pressing the Dor Cbut- ton. 2. Select either INT or EXT by pressing the +or -but- ton. INT:Advances a sequence by the Dwell Time that was programmed on the SPOT LIVE SEQUENCE SETUP. EXT:Advances a sequence by the input from pin 5 of the ALARM port. The factory default setting is INT. Auto Skip Setting This item lets you enable or disable the auto skip function on the Spot Monitor to skip any steps when no video signal is present. 1. Move the cursor to the AUTO SKIP parameter in the SEQUENCE SETUP by pressing the Dor Cbutton. 2. Select either ON or OFF by pressing the +or -but- ton. ON:Enables the auto skip function on the Spot Monitor. OFF:Disables the auto skip function on the Spot Monitor. The factory default setting is ON. Power on Status Setup The items let you select a pattern on the monitor screen when the Disk Recorder’s power is turned on. Power on Setting (Multiscreen Monitor) This item lets you select a display pattern on the Multiscreen Monitor when the Disk Recorder’s power is turned on. 1. Move the cursor to the MULTI OUTPUT parameter in the MULTIPLEXER SETUP menu by pressing the Dor Cbutton. 2. Select a display pattern to be set by pressing the +or -button. 1 - 16:Selects an assigned camera image in single spot mode. SPOT SEQ:Selects a sequence pattern programmed in the Live Sequence (Spot Monitor). QUAD-4A to QUAD-4D:Selects an assigned quad dis- play in spot mode. QUAD SEQ:Selects a sequence pattern programmed in the Live Sequence (Multiscreen Monitor). 7 to 16SCREEN:Selects a display with the assigned segment. The factory default setting is QUAD-4A. Power on Setting (Spot Monitor) This item lets you select a display pattern on the Spot Monitor when the Disk Recorder’s power is turned on. 1. Move the cursor to the SPOT OUTPUT parameter in the MULTIPLEXER SETUP menu by pressing the Dor C button. 2. Select a display pattern to be set by pressing the +or -button. 1 - 16:Selects an assigned camera image in single spot mode. SPOT SEQ:Selects a sequence pattern programmed in the Live Sequence (Spot Monitor). The factory default setting is 1.
61 Secret View Setting When the video input is displayed in the spot mode on the Spot Monitor, the Multiscreen Monitor is enabled to skip the step in sequence or display a blackout in multiscreen for that selected input image. This function is called Secret View and the item lets you enable or disable this function on the Multiscreen Monitor. 1. Move the cursor to the SECRET VIEW parameter in the MULTIPLEXER SETUP menu by pressing the Dor C button. 2. Select either OFF or ON by pressing the +or -but- ton. OFF:Disables the secret view function. ON:Enables the secret view function. The factory default setting is OFF.
62 1. Move the cursor to ALARM SETUP in the WJ-HD500 SETUP menu by pressing the Dor Cbutton, then press the SETbutton. The ALARM SETUP menu shown below appears on the monitor screen. 2. Select an item or item parameter in the menu by press- ing the Dor Cbutton. 3. To return to the previous WJ-HD500 SETUP menu, press the SETUP/ESCbutton. Alarm Port Setting This item lets you designate the alarm input from the ALARM port located on the rear of the Disk Recorder. 1. Move the cursor to TERMINAL TRIGGER SETUP in the ALARM SETUP menu by pressing the Dor Cbutton, then press the SETbutton. The table shown below appears on the monitor screen. 2. Move the cursor to the input channel editing area by pressing the A, B, Dor Cbutton. 3. Select a camera number (1 - 16) corresponding to the input for the CAM editing area by pressing the +or - button. 6 ALARM SETUP TERMINAL TRIGGER SETUP AUTO RESET OFF ALARM OUTPUT 2S ALARM BUZZER 2S VIDEO LOSS ON VIDEO MOTION DETECTION OFF VMD AREA SETUP ALARM MODE MULTI OUTPUT SPOT SPOT OUTPUT SPOT 6-1 TERMINAL TRIGGER SETUP ALM CAM INPUT ALM CAM INPUT 1CH 1 N.O 9CH 9 N.O 2CH 2 N.O 10CH 10 N.O 3CH 3 N.O 11CH 11 N.O 4CH 4 N.O 12CH 12 N.O 5CH 5 N.O 13CH 13 N.O 6CH 6 N.O 14CH 14 N.O 7CH 7 N.O 15CH 15 N.O 8CH 8 N.O 16CH 16 N.O 4. Move the cursor to the INPUT editing area by pressing the Bbutton, then select the type of contact to meet the system requirement by pressing the +or -but- ton. N.O:Accepts alarm input from Normally Open con- tacts. N.C:Accepts alarm input from Normally Closed con- tacts. The factory default setting is N.O. 5. Repeat the above steps 2 to 4 to designate the other input channels. 6. When satisfied with all of the above steps, press the SETUP/ESCbutton to return to the previous ALARM SETUP menu. Alarm Auto Reset Setting This item lets you select the duration the Disk Recorder retains the alarm mode before resetting automatically. 1. Move the cursor to the AUTO RESET parameter in the ALARM SETUP menu by pressing the Dor Cbutton. 2. Select the desired duration by pressing the +or - button. OFF:Disables auto reset. 1S - 30S, 40S, 50S, 1M - 5M:Selects an alarm duration between 1 second and 5 minutes. The factory default setting is OFF. Alarm Output Setting This item lets you select the output duration of the alarm signal from the ALARM port. 1. Move the cursor to the ALARM OUTPUT parameter in the ALARM SETUP menu by pressing the Dor Cbut- ton. 2. Select the desired duration by pressing the +or - button. OFF:Disables alarm output, regardless of an incoming alarm. 1S - 30S, 40S, 50S, 1M - 5M:Selects an alarm duration between 1 second and 5 minutes. ALARM SETUP