Home > Panasonic > Recording Equipment > Panasonic Digital Disk Recorders Wj Hd500a Operating Instructions

Panasonic Digital Disk Recorders Wj Hd500a Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Digital Disk Recorders Wj Hd500a Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							53
    • “FPS” indicates as field per second or frame per
    second when the FIELD/FRAME parameter is set to
    FIELD or FRAME in the menu.
    Move the cursor to the REC QUALITY parameter by
    pressing the Dor Cbutton, then select a recording
    image quality by pressing the +or -button.
    SUPER FINE:For enhanced sharpness (Compression
    Rate 1/6)
    FINE:For fine image quality (Compression Rate 1/10)
    NORMAL:For normal image quality (Compression Rate
    1/16)
    EXTENDED:For extended time recording quality
    (Compression Rate 1/25)
    Alarm Active Mode 
    The item lets you select the active mode for group cameras
    in Time Lapse Recording when an alarm is received while
    recording with the internal programmed timer.
    1. Move the cursor to the TRIGGER ACTION parameter in
    the menu by pressing the Dor Cbutton.
    2. Select the desired active mode for assigned group
    cameras by pressing the +or -button.
    REC+ALM:Enables alarm recording and alarm activa-
    tion.
    REC:Enables only alarm recording.
    The ALARM display on the monitor is disabled.
    OFF:Deactivates alarm input.
    The ALARM display on the monitor is also disabled. 
    The factory default setting is REC+ALM.
    Event Recording
    These items let you set the recording mode in Time Lapse
    Recording when an alarm is received during the recording
    with the internal programmed timer.
    1. Move the cursor to the EVENT REC MODE parameter
    by pressing the Dor Cbutton, then select a recording
    time mode by pressing the +or -button.
    The parameters are the same as TIMER REC MODE
    except OFF.
    For details refer to TIMER REC MODE in this menu.
    2. Move the cursor to the REC RATE(MAX) parameter by
    pressing the Dor Cbutton, then select a recording
    rate by pressing the +or -button.
    For details refer to REC RATE in this menu.
    3. Move the cursor to the REC QUALITY parameter by
    pressing the Dor Cbutton, then select a recording
    image quality by pressing the +or -button.
    For details refer to REC QUALITY in this menu.4. Move the cursor to the DURATION parameter by press-
    ing the Dor Cbutton, then select the alarm recording
    duration by pressing the +or -button.
    2S - 6M:Enables alarm recording for between 2 sec-
    onds and 6 minutes.
    MANUAL:Enables alarm recording while the alarm sig-
    nal is received from the ALARM port.
    CONTINUE:Enables alarm recording until the REC
    STOP is pressed.
    The factory default setting is 10S.
    5. Move the cursor to the DYNAMIC REC parameter by
    pressing the Dor Cbutton, then select an alarm
    recording pattern by pressing the +or -button.
    OFF:Records the images assigned to the group inputs
    including the one which has activated the alarm.
    ALM-PRI:Records the alarm input images preferential-
    ly over other video inputs.
    ALM-ONLY:Records the particular images that have
    activated the alarm.
    ALM-MILUTI:Records multiple alarms adaptively.
    The factory default setting is OFF.
    6. If the parameter ALM-MULTI is selected for alarm
    recording pattern, move the cursor to the REC
    RATE(BASE) parameter by pressing the Dor Cbutton,
    then select a recording rate by pressing the +or -
    button.
    The recording rate can be selected as same as REC
    RATE(MAX) maximally.
    7. Move the cursor to the AUTO COPY parameter by
    pressing the Dor Cbutton, then select alarm backup
    mode by pressing the +or -button.
    This lets you enable or disable alarm data backup on
    the DVD-RAM disk. Refer to the DVD DRIVE SETUP for
    details.
    OFF:Disables alarm data backup.
    ON:Enables alarm data backup.
    The factory default setting is OFF.
    8. Press the SETUP/ESCbutton to return to the previous
    program number menu. 
    						
    							54
    Multi Shot Recording (Internal Timer)
    As described before, the Multi Shot Recording is an event
    recording function reacting to an alarm input.
    It records the number of images in pre- and post-recording.
    Pre-recording is the recorded images during standby, prior
    to the input of the alarm signal.
    Post-recording is the recorded images after the input of the
    alarm signal.
    These items let you determine the recording parameters for
    Multi Shot Recording assigned in the program number
    menu. 
    (continued from Program Timer)
    1. Select the recording mode M/S in the program number
    menu by pressing the +or -button, then press the
    SETbutton.
    The selected Multi Shot Recording menu as shown
    below appears on the monitor screen.
    2. Move the cursor to the TRIGGER ACTION parameter in
    the menu by pressing the Dor Cbutton, then select
    an active mode for group cameras when an alarm is
    received by pressing the +or -button.
    REC+ALM:Enables alarm recording and alarm activa-
    tion.
    REC:Enables only alarm recording.
    The ALARM display on the monitor is also disabled.
    The factory default setting is REC+ALM.
    3. Move the cursor to the REC RATE parameter in the
    menu by pressing the Dor Cbutton, then select the
    desired recording rate by pressing the +or -button.
    1 - 60FPS:Records the selected number of freeze
    images every second.
    0.5FPS:Records a freeze image every 2 seconds.
    0.4FPS:Records a freeze image every 2.5 seconds.
    0.3FPS:Records a freeze image every 3.3 seconds.
    0.2FPS:Records a freeze image every 5 seconds.
    0.1FPS:Records a freeze image every 10 seconds.
    The factory default setting is 15FPS.Notes:
    • The maximum recording rate depends on the
    selected parameters in the COMMON SETUP menu
    as shown in the table.
    FIELD/FRAME CAMERA GENLOCK REC RATE
    FIELD ON 60FPS
    OFF 30FPS
    FRAME 3DIM  ON 10FPS
    ON OFF 10FPS
    FRAME 3DIM  ON 30FPS
    OFF OFF 15FPS
    • “FPS” indicates as field per second or frame per
    second when the FIELD/FRAME parameter is set to
    FIELD or FRAME in the menu.
    4. Move the cursor to the REC QUALITY parameter by
    pressing the Dor Cbutton, then select a recording
    image quality by pressing the +or -button.
    SUPER FINE:For enhanced sharpness (Compression
    Rate 1/6)
    FINE:For fine image quality (Compression Rate 1/10)
    NORMAL:For normal image quality (Compression Rate
    1/16)
    EXTENDED:For extended recording quality (Compres-
    sion Rate 1/25)
    The factory default setting is SUPER FINE.
    5. Move the cursor to the PRE PICTURES parameter by
    pressing the Dor Cbutton, then select a number of
    the pre-recording image by pressing the +or -but-
    ton.
    0:Disables pre-recording.
    4 to maximum:Sets the number of images for pre-
    recording.
    • The maximum number of the pre-recording is deter-
    mined by the setting of FIELD/FRAME and REC QUALI-
    TY.
    The factory default setting is 15.
    The value that appears underneath the number of pre-
    recording images indicates the number of images to be
    recorded per assigned group camera (number of pre-
    recording images divided by number of the assigned
    group cameras).
    6. Move the cursor to the POST PICTURES parameter by
    pressing the Dor Cbutton, then select a number of
    the post-recording image by pressing the +or -but-
    ton.
    4 to 200:Sets the number of images for post-recording.
    The factory default setting is 60.
    3-1-1-1 PROG1-NO1-G1 REC SETUP
    M/S(EVENT:MULTI SHOT)
      TRIGGER ACTION        REC+ALM
      
      REC MODE
        REC RATE            15FPS
        REC QUALITY         SUPER FINE
      PRE PICTURES          15
                            XXX.X/CAM
      POST PICTURES         60
      DYNAMIC REC           OFF
      AUTO COPY             OFF 
    						
    							55
    7. Move the cursor to the DYNAMIC REC parameter by
    pressing the Dor Cbutton, then select the recording
    pattern for post-recording by pressing the +or -but-
    ton.
    OFF:Records the images assigned to group inputs,
    including the one that has activated the alarm (the
    same as pre-recording).
    ALM-ONLY:Records the particular image that has acti-
    vated the alarm.
    The factory default setting is OFF.
    8. Move the cursor to the AUTO COPY parameter by
    pressing the Dor Cbutton, then select alarm backup
    mode by pressing the +or -button.
    OFF:Disables alarm data backup.
    ON:Enables alarm data backup.
    The factory default setting is OFF.
    9. Press the SETUP/ESCbutton to return to the previous
    program number menu.
    One Shot Recording (Internal Timer)
    As described before, the One Shot Recording is an event
    recording function reacting to an alarm input.
    It records the number of particular images that have acti-
    vated the alarm.
    These items let you determine the recording parameters for
    One Shot Recording assigned in the program number
    menu.
    (continued from Program Timer)
    1. Select the recording mode O/S in the program number
    menu by pressing the +or -button, then press the
    SETbutton.
    The selected One Shot Recording menu as shown
    below appears on the monitor screen.
    2. Move the cursor to the TRIGGER ACTION parameter in
    the menu by pressing the Dor Cbutton, then select
    an active mode for group cameras when an alarm is
    received by pressing the +or -button.
    REC+ALM:Enables alarm recording and alarm activa-
    tion.
    REC:Enables only alarm recording.
    The ALARM display on the monitor is also disabled.
    The factory default setting is REC+ALM.3. Move the cursor to the REC RATE parameter in the
    menu by pressing the Dor Cbutton, then select the
    desired recording rate by pressing the +or -button.
    1 - 60FPS:Records the selected number of the freeze
    image per second.
    The factory default setting is 15FPS.
    Notes:
    • The maximum recording rate depends on the
    selected parameters in the COMMON SETUP menu
    as shown in the table.
    FIELD/FRAME CAMERA GENLOCK REC RATE
    FIELD ON 60FPS
    OFF 30FPS
    FRAME 3DIM  ON 10FPS
    ON OFF 10FPS
    FRAME 3DIM  ON 30FPS
    OFF OFF 15FPS
    • “FPS” indicates as field per second or frame per
    second when the FIELD/FRAME parameter is set to
    FIELD or FRAME in the menu.
    4. Move the cursor to the REC QUALITY parameter by
    pressing the Dor Cbutton, then select the desired
    image quality by pressing the +or -button.
    SUPER FINE:For enhanced sharpness (Compression
    Rate 1/6)
    FINE:For fine image quality (Compression Rate 1/10)
    NORMAL:For normal image quality (Compression Rate
    1/16)
    EXTENDED:For extended time recording quality
    (Compression Rate 1/25)
    The factory default setting is SUPER FINE.
    5. Move the cursor to the PICTURE parameter by pressing
    the Dor Cbutton, then select the number of freeze
    images to be recorded by pressing the +or -button.
    4 to 60:Records the selected number of freeze images
    for One Shot Recording.
    The factory default setting is 16.
    6. Move the cursor to the AUTO COPY parameter by
    pressing the Dor Cbutton, then select an alarm back-
    up mode by pressing the +or -button.
    OFF:Disables backup for alarm recording.
    ON:Enables backup for alarm recording.
    The factory default setting is OFF.
    7. Press the SETUP/ESCbutton to return to the previous
    program number menu.
    3-1-1-1 PROG1-NO1-G1 REC SETUP
    O/S(EVENT:ONE SHOT)
      TRIGGER ACTION        REC+ALM
      
      REC MODE
        REC RATE            15FPS
        REC QUALITY         SUPER FINE
      PICTURES              16
      AUTO COPY             OFF 
    						
    							56
    Emergency Recording 
    (Time Lapse Recording)
    The Emergency Recording is given priority to record all
    video inputs in Time Lapse Recording reacting to a signal
    input form the CONTROL port.
    These items let you determine the recording parameters for
    Time Lapse Recording when the input signal is received
    from pin 21 of the CONTROL port located on the rear of the
    Disk Recorder.
    1. Move the cursor to EMERGENCY in the WJ-HD500
    SETUP menu by pressing the Dor Cbutton.
    2. Select either audio recording function by pressing the
    +or -button, then press the SETbutton.
    The selected EMERGENCY REC SETUP menu shown
    below appears on the monitor screen.
    3. Move the cursor to the EMERGENCY REC MODE para-
    meter in the menu by pressing the Dor Cbutton, then
    select the desired recording time mode by pressing the
    +or -button.
    SF-✽✽H or SF-A*✽✽H:Selects the recording time
    mode in enhanced fine quality.
    FQ-✽✽H or FQ-A*✽✽H:Selects the recording time
    mode in fine quality.
    NQ-✽✽H or NQ-A*✽✽H:Selects the recording time
    mode in normal quality.
    EX-✽✽H or EX-A*✽✽H:Selects the recording time
    mode in extended time quality.
    SP or SP-A*:Freely selectable 
    ✽✽indicates the hours for recording time mode:
    2, 12, 18, 24, 48, 72, 96, 120, 180, 240, 360, 480,
    720, 960, 1200, 1440, 2160, 2880, 3600, 4320,
    6480, 8640 
    (parameter A* indicates recording with audio)
    When the parameter SF/FQ/NQ/EX is selected for
    recording time, the recording rate and quality are auto-
    matically set according to the selected recording time.
    Note:It may not be possible to set the recording time,
    depending on the remaining storage capacity of the
    hard disk.
    The factory default setting is SF-24H.4. If the parameter SP is selected for the recording time,
    move the cursor to the REC RATE parameter by press-
    ing the Dor Cbutton, then select the desired record-
    ing rate by pressing the +or -button.
    1 - 60FPS:Records the selected number of freeze
    images every second.
    0.5FPS:Records a freeze image every 2 seconds.
    0.4FPS:Records a freeze image every 2.5 seconds.
    0.3FPS:Records a freeze image every 3.3 seconds.
    0.2FPS:Records a freeze image every 5 seconds.
    0.1FPS:Records a freeze image every 10 seconds.
    Notes:
    • The maximum recording rate depends on the
    selected parameters in the COMMON SETUP menu
    as shown in the table.
    FIELD/FRAME CAMERA GENLOCK REC RATE
    FIELD ON 60FPS
    OFF 30FPS
    FRAME 3DIM  ON 10FPS
    ON OFF 10FPS
    FRAME 3DIM  ON 30FPS
    OFF OFF 15FPS
    • “FPS” indicates as field per second or frame per
    second when the FIELD/FRAME parameter is set to
    FIELD or FRAME in the menu.
    Move the cursor to the REC QUALITY parameter by
    pressing the Dor Cbutton, then select a recording
    image quality by pressing the +or -button.
    SUPER FINE:For enhanced sharpness (Compression
    Rate 1/6)
    FINE:For fine image quality (Compression Rate 1/10)
    NORMAL:For normal image quality (Compression Rate
    1/16)
    EXTENDED:For extended time recording quality
    (Compression Rate 1/25)
    5. Move the cursor to the DURATION parameter by press-
    ing the Dor Cbutton, then select the recording dura-
    tion by pressing the +or -button.
    2S - 6M:Enables recording for between 2 seconds and
    6 minutes.
    MANUAL:Enables recording while the input signal is
    received from the CONTROL port.
    CONTINUE:Enables recording until the REC STOP but-
    ton is pressed.
    The factory default setting is 10S.
    6. Press the SETUP/ESCbutton to return to the previous
    WJ-HD500 SETUP menu.
    4 EMERGENCY REC SETUP(WITHOUT AUDIO)
    EMERGENCY REC MODE      SF- 24H
      REC RATE              7.5FPS
      REC QUALITY           SUPER FINE
      DURATION              10S 
    						
    							57
    Sequence Setup (Multiscreen
    Monitor)
    There are three sequence patterns to run on the
    Multiscreen Monitor.
    The items shown below let you program the sequence to
    run on the Multiscreen Monitor.
    Live Sequence
    Live sequence is a series of 16 steps assigned to the
    Multiscreen Monitor.
    The sequence steps can be combined with four screen
    segments (quad) display.
    Live Sequence Pattern Setting
    1. Move the cursor to MULTI LIVE SEQUENCE SETUP in
    the SEQUENCE SETUP menu by pressing the Dor C
    button, then press the SETbutton.
    The menu shown below appears on the monitor screen.
    2. Move the cursor to the step editing area by pressing
    the A, B, Dor Cbutton.
    3. Select a camera to be displayed for CAM editing area
    by pressing the +or -button.
    1 - 16:Displays the image of the selected camera num-
    ber. 
    4A - 4D:Displays the assigned images in quad.
    Refer to the QUAD PATTERN SETUP for settings. 
    --:Disables display and will skip automatically.
    4. Move the cursor to the PRESET editing area by press-
    ing the Bbutton, then select a preset position to be
    displayed by pressing the +or -button, if applica-
    ble.
    1 - 64:Selects a preset position of the assigned cam-
    era.
    --:No preset position
    The factory default setting is --. These items let you determine functions such as sequence
    and power on status for this Disk Recorder.
    1. Select MULTIPLEXER SETUP in the WJ-HD500 SETUP
    menu by pressing the Dor Cbutton, then press the
    SETbutton.
    The MULTIPLEXER SETUP menu as shown below
    appears on the monitor screen.
    2. Select an item or item parameter in the menu by press-
    ing the Dor Cbutton.
    3. To return to the WJ-HD500 SETUP menu, press the
    SETUP/ESCbutton.
    Sequence Setup
    These items let you program the sequence pattern for the
    Spot and Multiscreen Monitor.
    1. Move the cursor to SEQUENCE SETUP in the MULTI-
    PLEXER SETUP menu by pressing the Dor Cbutton,
    then press the SETbutton.
    The SEQUENCE SETUP menu as shown below appears
    on the monitor screen.
    2. Select an item or item parameter in the SEQUENCE
    SETUP menu by pressing the Dor Cbutton.
    3. To return to the previous MULTIPLEXER SETUP menu,
    press the SETUP/ESCbutton.
    5 MULTIPLEXER SETUP
    SEQUENCE SETUP
    POWER ON MULTI OUTPUT   QUAD-4A
             SPOT OUTPUT    1
    SECRET VIEW             OFF
    5-1 SEQUENCE SETUP
    MULTI  LIVE SEQUENCE SETUP
             QUAD SHIFT    OFF
             QUAD PATTERN SETUP
             SEQ TIMING    INT
           GROUP SEQ MODE  QUAD
             SEQ DWELL     2S
           AUTO SKIP       ON
    SPOT   LIVE SEQUENCE SETUP
             SEQ TIMING    INT
           AUTO SKIP       ON
    5-1-1 MULTI LIVE SEQUENCE SETUP
              PRE-                PRE-
    STEP CAM  SET  SEC  STEP CAM  SET  SEC
      1  4A    --   2S    9   --   --   0S
      2  4B    --   2S   10   --   --   0S
      3  4C    --   2S   11   --   --   0S
      4  4D    --   2S   12   --   --   0S
      5  --    --   0S   13   --   --   0S   
      6  --    --   0S   14   --   --   0S
      7  --    --   0S   15   --   --   0S
      8  --    --   0S   16   --   --   0S
    MULTIPLEXER SETUP 
    						
    							58
    2. Move the cursor to the editing area to assign a camera
    by pressing the A, B, Dor Cbutton.
    3. Select a camera number to be assigned by pressing
    the +or -button.
    AREA indicates the display pattern, including the cam-
    era assignment and display positions as shown below.
    4. Repeat the above steps 2 and 3 to assign a camera for
    other areas.
    5. When satisfied with all of the above steps, press the
    SETUP/ESCbutton to return to the previous
    SEQUENCE SETUP menu.
    Sequence Timing Setting
    This item lets you select between internal and external con-
    trol for advancing the sequence on the Multiscreen Monitor.
    1. Move the cursor to the SEQ TIMING parameter in the
    SEQUENCE SETUP menu by pressing the Dor Cbut-
    ton.
    2. Select either INT or EXT by pressing the +or -but-
    ton.
    INT:Advances a sequence by the Dwell Time that was
    programmed on the MULTI LIVE SEQUENCE
    SETUP.
    EXT:Advances a sequence by the input from pin 5 of
    the ALARM port.
    The factory default setting is INT. Note:To assign the parameters 1 - 64, the specified
    combination cameras are equipped in the system
    with a PS
    •Data* mode.
    5. Move the cursor to the SEC editing area by pressing
    the Bbutton, then select the desired dwell time by
    pressing the +or -button.
    0S:The step will not be displayed on the monitor.
    1S - 30S:Selects a dwell time between 1 second and
    30 seconds.
    6. Repeat the above steps 2 to 5 to program the other
    steps.
    7. When satisfied with all of the above steps, press the
    SETUP/ESCbutton to return to the previous
    SEQUENCE SETUP menu.
    Quad Shift Setting
    This item lets you enable or disable the quad shift operation
    when the MULTISCREEN SELECT button is pressed.
    Quad shift displays an image series such as 4A, 4B, 4C
    and 4D previously programmed on four screen segments.
    1. Move the cursor to the QUAD SHIFT parameter in the
    SEQUENCE SETUP menu by pressing the Dor Cbut-
    ton.
    2. Select either ON or OFF by pressing the +or -but-
    ton.
    ON:Enables the quad shift operation.
    OFF:Disables the quad shift operation.
    The initial factory setting is OFF.
    Quad Pattern Setup
    This item lets you select the pattern to be displayed on the
    Multiscreen Monitor when a 4-segment (Quad) display is
    selected in spot or sequence.
    The camera images can be assigned to the segments as
    shown below.
    1. Move the cursor to QUAD PATTERN SETUP in the
    SEQUENCE SETUP menu by pressing the Dor Cbut-
    ton, then press the SETbutton.
    The menu shown below appears on the monitor screen.
    5-1-2 MULTI QUAD PATTERN SETUP
    AREA CAM    AREA CAM
    4A-1   1    4C-1   9
    4A-2   2    4C-2  10
    4A-3   3    4C-3  11
    4A-4   4    4C-4  12
    4B-1   5    4D-1  13
    4B-2   6    4D-2  14
    4B-3   7    4D-3  15
    4B-4   8    4D-4  16
    4A-1
    4A-34A-2
    4A-4 
    						
    							59
    Sequence Setup (Spot Monitor)
    This item lets you program the live sequence pattern to be
    run on the Spot Monitor.
    Live sequence is a series of 16 steps assigned to the Spot
    Monitor. This sequence can be run on the Multiscreen
    Monitor by operating the buttons.
    Live Sequence Pattern Setting
    1. Move the cursor to SPOT LIVE SEQUENCE SETUP in
    the SEQUENCE SETUP menu by pressing the Dor C
    button, then press the SETbutton.
    The menu shown below appears on the monitor screen.
    2. Move the cursor to the step editing area by pressing
    the A, B, Dor Cbutton.
    3. Select a camera number to be displayed for the CAM
    editing area by pressing the +or -button.
    1 - 16:Displays the image of the selected camera num-
    ber.
    --:Disables the display and will skip automatically.
    4. Move the cursor to the PRESET editing area by press-
    ing the Bbutton, then select a preset position to be
    displayed by pressing the +or -button, if applica-
    ble.
    1 - 64:Selects a preset position of the assigned cam-
    era.
    --:No preset position
    The factory default setting is --.
    Note:To assign the parameters 1 - 64, the specified
    combination cameras are equipped in the system
    with a PS
    •Data* mode.
    5. Move the cursor to SEC editing area by pressing the B
    button, then select the desired dwell time by pressing
    the +or -button.
    0S:The step will not be displayed on the monitor.
    1S - 30S:Selects the dwell time between 1 second and
    30 seconds.
    The factory default setting is 2S.
    Group Multi Sequence Setting
    As described before, the cameras are assigned to 4
    groups for recording with a programmed internal timer.
    This item lets you select the sequence pattern to be dis-
    played of each group on the Multiscreen Monitor.
    Group Multi Sequence Pattern Setting
    1. Move the cursor to the GROUP SEQ MODE parameter
    in the SEQUENCE SETUP by pressing the Dor Cbut-
    ton.
    2. Select either QUAD or MULTI GROUP display mode to
    be run on the monitor by pressing the +or -button.
    MULTI GROUP:Camera images are displayed in
    sequence with the minimum quantities of the seg-
    ment screen.
    QUAD:Camera images are displayed with a 4-segment
    screen in sequence.
    The factory default setting is QUAD.
    Dwell Time Setting
    1. Move the cursor to the SEQ DWELL parameter in the
    SEQUENCE SETUP by pressing the Dor Cbutton.
    2. Select the desired dwell time for the group sequence
    by pressing the +or -button.
    1S - 30S:Selects the dwell time between 1 second and
    30 seconds.
    The factory default setting is 2S.
    Auto Skip Setting
    This item lets you enable or disable the auto skip function
    on the Multiscreen Monitor to skip any steps when no video
    signal is present.
    1. Move the cursor to the AUTO SKIP parameter in the
    SEQUENCE SETUP by pressing the Dor Cbutton.
    2. Select either ON or OFF by pressing the +or -but-
    ton.
    ON:Enables the auto skip function on the Multiscreen
    Monitor.
    OFF:Disables the auto skip function on the Multiscreen
    Monitor.
    The factory default setting is ON.
    5-1-3 SPOT LIVE SEQUENCE SETUP
              PRE-                PRE-
    STEP CAM  SET  SEC  STEP CAM  SET  SEC
      1    1   --   2S    9    9   --   2S
      2    2   --   2S   10   10   --   2S
      3    3   --   2S   11   11   --   2S
      4    4   --   2S   12   12   --   2S
      5    5   --   2S   13   13   --   2S   
      6    6   --   2S   14   14   --   2S
      7    7   --   2S   15   15   --   2S
      8    8   --   2S   16   16   --   2S 
    						
    							60
    6. Repeat the above steps 2 to 5 to set up the other steps.
    7. When satisfied with all of the above steps, press the
    SETUP/ESC button to return to the previous
    SEQUENCE SETUP menu.
    Sequence Timing Setting
    This item lets you select between internal and external con-
    trol for advancing the sequence on the Spot Monitor.
    1. Move the cursor to the SEQ TIMING parameter in the
    SEQUENCE SETUP menu by pressing the Dor Cbut-
    ton.
    2. Select either INT or EXT by pressing the +or -but-
    ton.
    INT:Advances a sequence by the Dwell Time that was
    programmed on the SPOT LIVE SEQUENCE
    SETUP.
    EXT:Advances a sequence by the input from pin 5 of
    the ALARM port.
    The factory default setting is INT.
    Auto Skip Setting
    This item lets you enable or disable the auto skip function
    on the Spot Monitor to skip any steps when no video signal
    is present.
    1. Move the cursor to the AUTO SKIP parameter in the
    SEQUENCE SETUP by pressing the Dor Cbutton.
    2. Select either ON or OFF by pressing the +or -but-
    ton.
    ON:Enables the auto skip function on the Spot Monitor.
    OFF:Disables the auto skip function on the Spot
    Monitor.
    The factory default setting is ON.
    Power on Status Setup
    The items let you select a pattern on the monitor screen
    when the Disk Recorder’s power is turned on.
    Power on Setting (Multiscreen
    Monitor)
    This item lets you select a display pattern on the
    Multiscreen Monitor when the Disk Recorder’s power is
    turned on.
    1. Move the cursor to the MULTI OUTPUT parameter in
    the MULTIPLEXER SETUP menu by pressing the Dor
    Cbutton.
    2. Select a display pattern to be set by pressing the +or
    -button.
    1 - 16:Selects an assigned camera image in single
    spot mode.
    SPOT SEQ:Selects a sequence pattern programmed
    in the Live Sequence (Spot Monitor).
    QUAD-4A to QUAD-4D:Selects an assigned quad dis-
    play in spot mode.
    QUAD SEQ:Selects a sequence pattern programmed
    in the Live Sequence (Multiscreen Monitor).
    7 to 16SCREEN:Selects a display with the assigned
    segment.
    The factory default setting is QUAD-4A.
    Power on Setting (Spot Monitor)
    This item lets you select a display pattern on the Spot
    Monitor when the Disk Recorder’s power is turned on.
    1. Move the cursor to the SPOT OUTPUT parameter in the
    MULTIPLEXER SETUP menu by pressing the Dor C
    button.
    2. Select a display pattern to be set by pressing the +or
    -button.
    1 - 16:Selects an assigned camera image in single
    spot mode.
    SPOT SEQ:Selects a sequence pattern programmed
    in the Live Sequence (Spot Monitor).
    The factory default setting is 1. 
    						
    							61
    Secret View Setting
    When the video input is displayed in the spot mode on the
    Spot Monitor, the Multiscreen Monitor is enabled to skip the
    step in sequence or display a blackout in multiscreen for
    that selected input image.
    This function is called Secret View and the item lets you
    enable or disable this function on the Multiscreen Monitor.
    1. Move the cursor to the SECRET VIEW parameter in the
    MULTIPLEXER SETUP menu by pressing the Dor C
    button.
    2. Select either OFF or ON by pressing the +or -but-
    ton.
    OFF:Disables the secret view function.
    ON:Enables the secret view function.
    The factory default setting is OFF. 
    						
    							62
    1. Move the cursor to ALARM SETUP in the WJ-HD500
    SETUP menu by pressing the Dor Cbutton, then
    press the SETbutton.
    The ALARM SETUP menu shown below appears on the
    monitor screen.
    2. Select an item or item parameter in the menu by press-
    ing the Dor Cbutton.
    3. To return to the previous WJ-HD500 SETUP menu,
    press the SETUP/ESCbutton.
    Alarm Port Setting
    This item lets you designate the alarm input from the
    ALARM port located on the rear of the Disk Recorder.
    1. Move the cursor to TERMINAL TRIGGER SETUP in the
    ALARM SETUP menu by pressing the Dor Cbutton,
    then press the SETbutton.
    The table shown below appears on the monitor screen.
    2. Move the cursor to the input channel editing area by
    pressing the A, B, Dor Cbutton.
    3. Select a camera number (1 - 16) corresponding to the
    input for the CAM editing area by pressing the +or -
    button.
    6 ALARM SETUP
    TERMINAL TRIGGER SETUP
    AUTO RESET              OFF
    ALARM OUTPUT            2S
    ALARM BUZZER            2S
    VIDEO LOSS              ON
    VIDEO MOTION DETECTION  OFF
      VMD AREA SETUP
    ALARM MODE MULTI OUTPUT SPOT
               SPOT OUTPUT  SPOT
    6-1 TERMINAL TRIGGER SETUP
     ALM CAM INPUT     ALM CAM INPUT
     1CH   1   N.O     9CH   9   N.O
     2CH   2   N.O    10CH  10   N.O
     3CH   3   N.O    11CH  11   N.O
     4CH   4   N.O    12CH  12   N.O
     5CH   5   N.O    13CH  13   N.O
     6CH   6   N.O    14CH  14   N.O
     7CH   7   N.O    15CH  15   N.O
     8CH   8   N.O    16CH  16   N.O 
    4. Move the cursor to the INPUT editing area by pressing
    the Bbutton, then select the type of contact to meet
    the system requirement by pressing the +or -but-
    ton.
    N.O:Accepts alarm input from Normally Open con-
    tacts.
    N.C:Accepts alarm input from Normally Closed con-
    tacts.
    The factory default setting is N.O.
    5. Repeat the above steps 2 to 4 to designate the other
    input channels.
    6. When satisfied with all of the above steps, press the
    SETUP/ESCbutton to return to the previous ALARM
    SETUP menu.
    Alarm Auto Reset Setting
    This item lets you select the duration the Disk Recorder
    retains the alarm mode before resetting automatically.
    1. Move the cursor to the AUTO RESET parameter in the
    ALARM SETUP menu by pressing the Dor Cbutton.
    2. Select the desired duration by pressing the +or -
    button.
    OFF:Disables auto reset.
    1S - 30S, 40S, 50S, 1M - 5M:Selects an alarm duration
    between 1 second and 5 minutes.
    The factory default setting is OFF.
    Alarm Output Setting
    This item lets you select the output duration of the alarm
    signal from the ALARM port.
    1. Move the cursor to the ALARM OUTPUT parameter in
    the ALARM SETUP menu by pressing the Dor Cbut-
    ton.
    2. Select the desired duration by pressing the +or -
    button.
    OFF:Disables alarm output, regardless of an incoming
    alarm.
    1S - 30S, 40S, 50S, 1M - 5M:Selects an alarm duration
    between 1 second and 5 minutes.
    ALARM SETUP 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Digital Disk Recorders Wj Hd500a Operating Instructions