Have a look at the manual Panasonic Digital Disk Recorders Wj Hd500a Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
43 Programming Menu Setup As shown below, the WJ-HD500 SETUP menu has eight main submenus. Seven of these are further divided into additional submenus. The mark indicates that the item has a submenu for more detailed setups. TIMER SETTING RECORDING SETUP Common Recording Setup Group Setup Program Timer Sequence Setup Alarm Port Setting Video Motion Detector Setting PS • Data Setup RS-232C Setup Clock Setup Time Adjustment Setting Disk Management Error Report System Information Password Lock Setting Buzzer Setting User Defined Setting Manual Recording Setup Timer Recording Setup Time Lapse Recording Multi Shot Recording Multiscreen Monitor Spot Monitor One Shot Recording Emergency Recording MULTIPLEXER SETUP ALARM SETUP Camera Title Setup DISPLAY SETUP COMMUNICATION SETUP SYSTEM SETUP DVD DRIVE SETUP SETUP Page 44 Page 45 Page 45 Page 46 Page 48 Page 50 Page 50 Page 52 Page 54 Page 55 Page 56 Page 57 Page 57 Page 57 Page 59 Page 62 Page 62 Page 63 Page 65 Page 65 Page 68 Page 68 Page 70 Page 72 Page 72 Page 73 Page 74 Page 75 Page 75 Page 76 Page 72 Page 73 Page 73
44 TIMER SETTING The timer recording mode is triggered by the internal or an external timer. This item lets you enable or disable the timer for recording. 1. Move the cursor to the TIMER parameter in the WJ- HD500 SETUP menu by pressing the Dor Cbutton. 2. Select a parameter to be activated by pressing the + or -button. INT:Selects the internal timer for recording as sched- uled in the programmed menu. EXT:Selects the external timer for power on recording when detecting power on and off. OFF:Timer recording is disabled. To record manually, set to this mode. The factory default setting is OFF. Note:When the parameter is set to something other than OFF, the Disk Recorder does not start record- ing even if the REC button is pressed. WJ-HD500 SETUP *.** TIMER OFF REC SETUP COMMON SETUP *MANUAL WITHOUT AUDIO *TIMER WITHOUT AUDIO *EMERGENCY WITHOUT AUDIO MULTIPLEXER SETUP ALARM SETUP DISPLAY SETUP COMMUNICATION SETUP SYSTEM SETUP DVD
45 Common Recording Setup These items let you determine the common recording set- tings, camera assignment for the groups and playback set- tings. 1. Move the cursor to COMMON SETUP in the WJ-HD500 SETUP menu by pressing the Dor Cbutton, then press the SETbutton. The COMMON SETUP menu as shown below appears on the Multiscreen Monitor. 2. To select an item or an item parameter from the COM- MON SETUP menu, move the cursor to the item or item parameter by pressing the Dor Cbutton. 3. To return to the previous WJ-HD500 SETUP menu, press the SETUP/ESCbutton. Recording Quality Setup These items let you determine the image quality recorded on the Hard Disk. Video Pixels (Resolution) This item lets you select the pixel number (number of hori- zontal x vertical image elements) or resolution of the video image. 1. Move the cursor to the FIELD/FRAME parameter in the COMMON SETUP menu by pressing the Dor Cbut- ton. 2. Select the desired mode by pressing the +or -but- ton. FRAME 3DIM ON:High resolution (720 x 480) distor- tion-free image FRAME 3DIM OFF:High resolution (720 x 480) image. FIELD:Normal resolution (720 x 240) image The factory default setting is FIELD. Color Mode Setting This item lets you enable or disable recording in color or black and white. 1. Move the cursor to the COLOR MODE parameter in the COMMON SETUP menu by pressing the Dor Cbut- ton. 2. Select the desired mode by pressing the +or -but- ton. COLOR FINE:Images are recorded with enhanced col- ors. COLOR STD:Images are recorded with normal colors. B/W:Images are recorded in black-and-white. The factory default setting is COLOR STD. Camera Sync Setting This item lets you determine camera synchronization in the system. 1. Move the cursor to the CAMERA GENLOCK parameter on the COMMON SETUP menu by pressing the Dor C button. 2. Select the desired mode by pressing the +or -but- ton. 1 COMMON SETUP REC QUALITY FIELD/FRAME FIELD COLOR MODE COLOR STD CAMERA GENLOCK OFF GROUP SETUP CAMERA ASSIGNMENT TITLE TITLE EMBEDDED OFF TIME EMBEDDED OFF THUMBNAIL 8 PLAYBACK MODE ALL SHUTTLE SPEED LOW HDD DISKEND STOP RECORDING SETUP
46 Group Title Setup This item lets you edit the group title to be displayed on the monitor screen. Each title is composed of 8 alphanumeric characters. 1. Move the cursor to TITLE in the COMMON SETUP menu by pressing the Dor Cbutton, then press the SETbut- ton. The GROUP SETUP (TITLE) menu as shown below appears on the monitor screen. 2. Move the cursor to the group editing area to be edited by pressing the Dor Cbutton. 3. Select a character by pressing the +or -button. The characters shown below can be selected in sequence. Numeral:0 1 2 3 4 5 6 7 8 9 Alphabet:A to Z, a to z Symbols:←→= ? # $ % & ( ) *+ , – . / : ; Space:• 4. Press the Bbutton to move the cursor to the right, then select a character by pressing the +or -button. 5. Repeat the above steps 3 and 4 until all characters are completed for the selected group title. If a wrong character is selected, move the cursor to the character to be replaced by pressing the Aor Bbut- ton, then select a new character by pressing the +or -button. 6. Repeat the above steps 2 to 5 to edit other group titles. 7. When satisfied with all the group titles, press the SETUP/ESCbutton to return to the previous COMMON SETUP menu. ON:Select this mode when the cameras are gen- locked to the system. OFF:Select this mode when asynchronous cameras are used in the system. The default setting is OFF. Note:Confirm camera synchronization in the system. The incorrect setting will cause improper recording. Group Setup As described before, the Disk Recorder activates the recording function of the assigned cameras in four groups when the TIMER is set to INT (internal). These items let you determine the camera’s group for recording. Camera Assignment 1. Move the cursor to CAMERA ASSIGNMENT in the COMMON SETUP menu by pressing the Dor Cbut- tons, then press the SETbutton. The GROUP SETUP (CAMERA ASSIGNMENT) menu as shown below appears on the monitor screen. 2. Move the cursor to the group editing area for the cam- eras by pressing the A, B, Dor Cbuttons. 3. Select a group number (1to 4) to be assigned by pressing the +or -button. The factory default setting is 1. 4. Repeat the above step 2 and 3 to assign the group number for other cameras. 5. When all camera assignments are completed, press the SETUP/ESCbutton to return to the previous COMMON SETUP menu. 1-2 GROUP SETUP(TITLE) GROUP1 G1•••••• GROUP2 G2•••••• GROUP3 G3•••••• GROUP4 G4•••••• 1-1 GROUP SETUP(CAMERA ASSIGNMENT) CAM GROUP CAM GROUP 1 1 9 1 2 1 10 1 3 1 11 1 4 1 12 1 5 1 13 1 6 1 14 1 7 1 15 1 8 1 16 1
47 Playback Mode Setup This item lets you select the playback mode according to the recorded number when the PLAYBACK button is pressed. 1. Move the cursor to the PLAYBACK MODE parameter in the COMMON SETUP menu by pressing the Dor C button. 2. Select the desired mode to be played back by pressing the +or -button. ALL:All the records are played back with automatic switching. LOOP:Repeats playing back the selected number of the recording. ONE:Switches to standby mode for the next operation, after the selected recording number has been played back once. The factory default setting is ALL. Shuttle Speed Setup This item lets you select the search speed for playing back the recorded images when the Shuttle Ring is rotated to maximum position. 1. Move the cursor to the SHUTTLE SPEED parameter in the COMMON SETUP menu by pressing the Dor C button. 2. Select the desired playback mode by pressing the + or -button. LOW:Searches record at 5 times speed. MID:Searches record at 50 times speed HIGH:Searches record at 100 times speed. The factory default setting is LOW. Recording of the Title Display This item lets you enable or disable recording of the cam- era and group titles with the image on the Hard Disk. 1. Move the cursor to the TITLE EMBEDDED parameter in the COMMON SETUP menu by pressing the Dor C button. 2. Select either ON or OFF by pressing the +or -but- ton. ON:Enables recording of the titles on the Hard Disk. OFF:Disables recording of the titles on the Hard Disk. The factory default setting is OFF. Recording of the Clock Display This item lets you enable or disable recording of the clock (date and time) with the image on the Hard Disk. 1. Move the cursor to the TIME EMBEDDED parameter in the COMMON SETUP menu by pressing the Dor C button. 2. Select either ON or OFF by pressing the +or -but- ton. ON:Enables recording of the clock on the Hard Disk. OFF:Disables recording of the clock on the Hard Disk. The factory default setting is OFF. Thumbnail Display Setup This item lets you select the maximum number of thumbnail images displayed in the search window. 1. Move the cursor to the THUMBNAIL parameter in the COMMON SETUP menu by pressing the Dor Cbut- ton. 2. Select either 8 or 16 by pressing the +or -button. 8:Displays a maximum of 8 thumbnail images. 16:Displays a maximum of 16 thumbnail images. The factory default setting is 8.
48 Hard Disk End Setup This item lets you enable or disable uninterrupted recording when the hard disk space is used up. 1. Move the cursor to the HDD DISKEND parameter in the COMMON SETUP menu by pressing the Dor Cbut- ton. 2. Select the desired mode by pressing the +or -but- ton. STOP:Stops recording when the disk is full. CONTINUE:Continues recording by overwriting the oldest data when the disk is full. ALM CONTINUE:Continues only recording the data while an alarm is activated by overwriting the oldest data, when the disk is full. The factory default setting is STOP. Manual Recording Setup The Disk Recorder can be recorded the images in Time Lapse recording when the REC button is pressed manually. Manual Recording is disabled when the TIMER in the setup menu is set to something other than OFF. These settings are also valid for External Timer Recording when the TIMER in the setup menu is set to EXT. These items let you determine the image quality and active mode for manual recording. 1. Move the cursor to MANUAL in the WJ-HD500 SETUP menu by pressing the Dor Cbutton. 2. Pressing the +or -button will toggle the display on the cursor as shown below. 3. Pressing the SETbutton will call up the MANUAL REC SETUP menu according to the specified audio function, as shown below. 4. To return to the previous WJ-HD500 SETUP menu, press the SETUP/ESCbutton. Manual Recording Mode Setting 1. Move the cursor to the MANUAL REC MODE parameter in the MANUAL REC SETUP menu by pressing the Dor Cbutton. 2. Select the recording time mode to be set by pressing the +or -button. SF-✽✽H or SF-A*✽✽H:Selects the recording time mode in enhanced fine quality. FQ-✽✽H or FQ-A*✽✽H:Selects the recording time mode in fine quality. NQ-✽✽H or NQ-A*✽✽H:Selects the recording time mode in normal quality. EX-✽✽H or EX-A*✽✽H:Selects the recording time mode in extended quality. SP or SP-A*:Freely selectable → MANUAL WITH AUDIO → MANUAL WITHOUT AUDIO → 2 MANUAL REC SETUP(WITHOUT AUDIO) MANUAL REC MODE SF- 24H REC RATE 7.5FPS REC QUALITY SUPER FINE EVENT REC MODE SF- 24H REC RATE(MAX) 7.5FPS REC QUALITY SUPER FINE DURATION 10S DYNAMIC REC OFF REC RATE(BASE) TRIGGER ACTION SETUP
49 ✽✽indicates the hours for recording time mode: 2, 12, 18, 24, 48, 72, 96, 120, 180, 240, 360, 480, 720, 960, 1200, 1440, 2160, 2880, 3600, 4320, 6480, 8640 (parameter A* indicates recording with audio) When the parameter SF/FQ/NQ/EX is selected for recording time, the recording rate and quality are auto- matically set according to the selected recording time. Note:It may not be possible to set the recording time, depending on the remaining storage capacity of the hard disk. The factory default setting is SF-24H. 3. If the parameter SP is selected for recording time, move the cursor to the REC RATE parameter by pressing the Dor Cbutton, then select a recording rate by pressing the +or -button. 1 - 60FPS:Records the selected number of freeze images every second. 0.5FPS:Records a freeze image every 2 seconds. 0.4FPS:Records a freeze image every 2.5 seconds. 0.3FPS:Records a freeze image every 3.3 seconds. 0.2FPS:Records a freeze image every 5 seconds. 0.1FPS:Records a freeze image every 10 seconds. Notes: • The maximum recording rate depends on the selected parameters in the COMMON SETUP menu as shown in the table. FIELD/FRAME CAMERA GENLOCK REC RATE FIELD ON 60FPS OFF 30FPS FRAME 3DIM ON 10FPS ON OFF 10FPS FRAME 3DIM ON 30FPS OFF OFF 15FPS • “FPS” indicates field per second or frame per sec- ond when the FIELD/FRAME parameter is set to FIELD or FRAME in the menu. Move the cursor to the REC QUALITY parameter by pressing the Dor Cbutton, then select a recording image quality by pressing the +or -button. SUPER FINE:For enhanced sharpness (Compression Rate 1/6) FINE:For fine image quality (Compression Rate 1/10) NORMAL:For normal image quality (Compression Rate 1/16) EXTENDED:For extended time recording quality (Compression Rate 1/25) The factory default setting is SUPER FINE. Event Recording (Manual Recording) These items let you set the recording mode in Time Lapse Recording when an alarm is received during manual recording. 1. Move the cursor to the EVENT REC MODE parameter by pressing the Dor Cbutton, then select a recording time mode by pressing the +or -button. The parameters are the same as MANUAL REC MODE. The factory default setting is SF-24H. 2. Move the cursor to the REC RATE(MAX) parameter by pressing the Dor Cbutton, then select a recording rate by pressing the +or -button. For details refer to REC RATE in this menu. 3. Move the cursor to the REC QUALITY parameter by pressing the Dor Cbutton, then select a recording image quality by pressing the +or -button. For details refer to REC QUALITY in this menu. 4. Move the cursor to the DURATION parameter by press- ing the Dor Cbutton, then select an alarm recording duration by pressing the +or -button. OFF:Disables alarm recording. 2S - 6M:Enables alarm recording for between 2 sec- onds and 6 minutes. MANUAL:Enables alarm recording while the alarm sig- nal is received from the ALARM port. CONTINUE:Enables alarm recording until the REC STOP is pressed. The factory default setting is 10S. 5. Move the cursor to the DYNAMIC REC parameter by pressing the Dor Cbutton, then select an alarm recording pattern by pressing the +or -button. OFF:Records all input images starting from input 1. ALM-PRI:Records the alarmed input images preferen- tially over other video inputs. ALM-ONLY:Records the particular images that have activated the alarm. ALM-MULTI:Records multiple alarms adaptively. The factory default setting is OFF. 6. If the parameter ALM-MULTI is selected for the alarm recording pattern, move the cursor to the REC RATE(BASE) parameter by pressing the Dor Cbutton, then select a recording rate by pressing the +or - button. The recording rate can be selected as same as REC RATE(MAX) maximally.
50 Alarm Active Mode (Manual Recording) This item lets you select the active mode when an alarm is received during manual recording. 1. Move the cursor to TRIGGER ACTION SETUP in the MANUAL REC SETUP menu by pressing the Dor C button, then press the SETbutton. The TRIGGER ACTION SETUP menu as shown below appears on the monitor screen. 2. Move the cursor to the active mode editing area for the camera by pressing the A, B,Cor Dbutton. 3. Select the desired active mode by pressing the +or -button. REC+ALM:Enables alarm recording and alarm activa- tion. REC:Enables only alarm recording. The ALARM display on the monitor is disabled. OFF:Deactivates alarm input. The ALARM display on the monitor is also disabled. The factory default setting is REC+ALM. 4. Repeat the above steps 2 and 3 to select the active mode for other cameras. 5. When all camera modes are completed, press the SETUP/ESCbutton to return to the previous MANUAL REC SETUP menu. 6. To return to the WJ-HD500 SETUP, press the SETUP/ ESCbutton. Timer Recording Setup The Disk Recorder can record the images triggered by the internal timer. The internal timer comprises four event times common to the recording groups, and is programmed in the setup. 1. Move the cursor to TIMER in the WJ-HD500 SETUP menu by pressing the Dor Cbutton. 2. Select either audio recording display by pressing the +or -button, then press the SETbutton. The TIMER REC SETUP menu according to the speci- fied audio function will appear on the monitor screen. Program Timer These items let you set the program timer for each day of the week. 1. Move the cursor to the program editing area for each day in the TIMER REC SETUP menu by pressing the D or Cbutton. 2. Select a program timer (PROG1to PROG4) to be assigned for the day. It is recommended to assign a program to a weekday, a weekend or on a daily basis. Selecting (---) will disable the program timer. 3. Repeat the above step to assign the program timer for other days. 4. Move the cursor to the assigned program number (PROG1), then press the SETbutton. The assigned program number menu as shown below appears on the monitor screen. 2-1 TRIGGER ACTION SETUP CAM ACTION CAM ACTION 1 REC+ALM 9 REC+ALM 2 REC 10 REC+ALM 3 OFF 11 REC+ALM 4 REC+ALM 12 REC+ALM 5 REC+ALM 13 REC+ALM 6 REC+ALM 14 REC+ALM 7 REC+ALM 15 REC+ALM 8 REC+ALM 16 REC+ALM 3 TIMER REC SETUP(WITHOUT AUDIO) PROGRAM SUNDAY --- MONDAY --- TUESDAY --- WEDNESDAY --- THURSDAY --- FRIDAY --- SATURDAY --- DAILY PROG1 TIMER SPECIAL DAY EXT REC MODE ---
51 8. Move the cursor to the editing area (NO. 2 to NO. 4) by pressing the Dor Cbutton, then repeat the steps 6 and 7 to edit the schedule. 9. When all settings are completed, press the SETUP/ESCbutton to return to the previous TIMER REC SETUP menu. Special Day Timer Before programming this table, confirm that the Program Timer is programmed completely. This table allows for up to 30 days to be defined as special days. In this table, 30 specific user defined days are assigned to one day of the week. 1. Move the cursor to TIMER SPECIAL DAY in the TIMER REC SETUP menu by pressing the Dor Cbutton, then press the SETbutton. The TIMER SPECIAL DAY SETUP table as shown below appears on the monitor screen. 2. Move the cursor to the DATE editing area by pressing the Dor Cbutton. 3. Select a month by pressing the +or -button. Move the cursor to the right by pressing the Bbutton, then select the date by pressing the +or -button. Note:The programmed month and date will be valid for every year. 4. Move the cursor to the ACT editing area by pressing the Bbutton, then select the day of the week by press- ing the +or -button. 5. Repeat the above steps 2 to 4 to program the other special days. 6. When satisfied with all special days, press the SETUP/ESCbutton to return to the previous TIMER REC SETUP menu. Note:To release the programmed special day timer, select “ ---” in the ACT column. Note:The program number menu (with audio) displays only the Group 1 editing area. 5. Move the cursor to the time editing area (NO. 1) by pressing the Dor Cbutton. 6. Move the cursor to the time to start and end the record- ing by pressing the Aor Bbutton, then select the time by pressing the +or -button. Notes: • If the time (No.1) to end the recording is set to 24:00, the editing function for the timers (No. 2 to No. 4) is disabled. • If the time (No.1) to end the recording is set to 12:00, the time (No. 2) to start a recording cannot be set to a time before 12:00. • When programming a timer extended into the next day, divide the timer event into two separate events and program both events separately in the program menu or other program menu. For example, Start End 0:00 7:00 23:00 24:00 7. Move the cursor to the recording editing area for groups by pressing the Aor Bbutton, then select the recording mode for groups by pressing the +or - button. T/L:Time Lapse Recording M/S:Multi Shot Recording O/S:One Shot Recording —:Disables Recording Note:For further recording settings, refer to the record- ing mode selected described later. 3-5 TIMER SPECIAL DAY SETUP DATE ACT DATE ACT DATE ACT 1 JUL 4 SUN 11 ----- --- 21 ----- --- 2 ----- --- 12 ----- --- 22 ----- --- 3 ----- --- 13 ----- --- 23 ----- --- 4 ----- --- 14 ----- --- 24 ----- --- 5 ----- --- 15 ----- --- 25 ----- --- 6 ----- --- 16 ----- --- 26 ----- --- 7 ----- --- 17 ----- --- 27 ----- --- 8 ----- --- 18 ----- --- 28 ----- --- 9 ----- --- 19 ----- --- 29 ----- --- 10 ----- --- 20 ----- --- 30 ----- --- 3-1 PROG1(WITHOUT AUDIO) NO START END G1 G2 G3 G4 1 0:00 6:00 T/L T/L T/L T/L RATE 7.5 7.5 1 10 2 6:00 12:00 M/S - O/S O/S RATE 10 5 1 3 12:00 18:00 M/S M/S M/S M/S RATE 5 2 2 5 4 18:00 24:00 O/S M/S - M/S RATE 15 10 10 SET TOTAL REC RATE ON EACH TABLE G1+G2+G3+G4= UNDER 60FPS 3-1 PROG1(WITH AUDIO) NO START END G1 1 0:00 6:00 T/L RATE 7.5 2 6:00 12:00 M/S RATE 10 3 12:00 18:00 M/S RATE 5 4 18:00 24:00 O/S RATE 15
52 External Program Timer The internal timer can be changed to the specified timer previously programmed by the input from the external timer. This function is enabled, when a contact is connect- ed with pin 22 of the ALARM port. This item lets you enable or disable the external timer for recording. 1. Move the cursor to the EXT REC MODE parameter in the TIMER REC SETUP menu by pressing the Dor C button. 2. Select the desired program to be changed by pressing the +or -button. PROG1 - 4:Selects a timer assigned program number. ---:Disables the external program timer. The factory default setting is ---. 3. Press the SETbutton to display the assigned program number menu previously programmed. If the program number menu has not been edited previ- ously, edit the assigned program number menu as described before. 4. Press the SETUP/ESCbutton to return to the previous setup menu. Time Lapse Recording (Internal Timer) These items let you set the recording parameters for Time Lapse Recording assigned in the program number menu. (Continued from Program Timer) 1. Select the recording mode T/L in the program number menu by pressing the +or -button, then press the SETbutton. The selected Time Lapse Recording menu shown below appears on the monitor screen. 2. Move the cursor to the TIMER REC MODE parameter in the menu by pressing the Dor Cbutton.3. Select the recording time mode to be set by pressing the +or -button. OFF:Disables normal recording and enables only alarm recording. SF-✽✽H or SF-A*✽✽H:Selects the recording time mode in enhanced fine quality. FQ-✽✽H or FQ-A*✽✽H:Selects the recording time mode in fine quality. NQ-✽✽H or NQ-A*✽✽H:Selects the recording time mode in normal quality. EX-✽✽H or EX-A*✽✽H:Selects the recording time mode in extended quality. SP or SP-A*:Freely selectable ✽✽indicates the hours for recording time mode: 2, 12, 18, 24, 48, 72, 96, 120, 180, 240, 360, 480, 720, 960, 1200, 1440, 2160, 2880, 3600, 4320, 6480, 8640 (parameter A* indicates recording with audio) When the parameter SF/FQ/NQ/EX is selected for recording time, the recording rate and quality are auto- matically set according to the selected recording time. Note:It may not be possible to set the recording time, depending on the remaining storage capacity of the hard disk. The factory default setting is SF-24H. 4. If the parameter SP is selected for recording time, move the cursor to the REC RATE parameter by pressing the Dor Cbutton, then select a recording rate by pressing the +or -button. 1 - 60FPS:Records the selected number of freeze images every second. 0.5FPS:Records a freeze image every 2 seconds. 0.4FPS:Records a freeze image every 2.5 seconds. 0.3FPS:Records a freeze image every 3.3 seconds. 0.2FPS:Records a freeze image every 5 seconds. 0.1FPS:Records a freeze image every 10 seconds. Notes: • The maximum recording rate depends on the selected parameters in the COMMON SETUP menu as shown in the table. FIELD/FRAME CAMERA GENLOCK REC RATE FIELD ON 60FPS OFF 30FPS FRAME 3DIM ON 10FPS ON OFF 10FPS FRAME 3DIM ON 30FPS OFF OFF 15FPS 3-1-1-1 PROG1-NO1-G1 REC SETUP T/L(TIME LAPSE) TIMER REC MODE SF- 24H REC RATE 7.5FPS QUALITY SUPER FINE TRIGGER ACTION REC+ALM EVENT REC MODE SF- 24H REC RATE(MAX) 7.5FPS REC QUALITY SUPER FINE DURATION 10S DYNAMIC REC OFF REC RATE(BASE) 1FPS AUTO COPY OFF