Have a look at the manual Panasonic Digital Disk Recorders Wj Hd500a Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
21 Connection with the Extension Units SCSI Connection The Digital Disk Recorder WJ-HD500A controls the extension units through the SCSI chain. 1. Connect the supplied SCSI cable between the EXT STORAGE port on the WJ-HD500A and the EXT IN port on the 1st extension unit. 2. Connect the supplied SCSI cable between the EXT OUT port on the 1st extension unit and the EXT IN port on the 2nd extension unit. Repeat connections in the same manner for all additional extension units. 3. The 3rd extension unit must be a WJ- HDE505if a further extension unit is con- nected. Use WJ-HDE500 if the 3rd unit is located at the end of the SCSI chain. Up to 6 extension units can be added. Switch Setting Data termination and SCSI number settings are required, as shown below. 1. Set the MODE switch #2 on the rear of the WJ-HD500A to ON when connecting with an extension unit. 2. Set the SCSI ID number for each unit by pressing the [–] or [+] button on the rear of the Extension Unit. 0 to 5 are applicable to the extension units. Note:SCSI ID 6 and 7 are reserved for WJ-HD500A Disk Recorder. 3. Set the termination switches on the rear of the Extension Units to ON or OFF. ON:Is applied to the extension unit located at the end of the SCSI chain. OFF:Is used for units other than the end unit. EXT STORAGE SIGNAL GNDSIGNAL GNDPOPOWERWERAC INC INSCSI IDSCSI IDEXT OUTEXT OUTEXT INEXT IN TERMINATERMINATORORGNDGNDTHERMAL ERRTHERMAL ERROR OUTOR OUTNCNC+ –OFFOFFONONONONOFFOFF SIGNAL GNDSIGNAL GNDPOPOWERWERAC INC INSCSI IDSCSI IDEXT OUTEXT OUTEXT INEXT IN TERMINATERMINATORORGNDGNDTHERMAL ERRTHERMAL ERROR OUTOR OUTNCNC+ –OFFOFFONONONONOFFOFF SIGNAL GNDSIGNAL GNDPOPOWERWERAC INC INSCSI IDSCSI IDEXT OUTEXT OUTEXT INEXT IN TERMINATERMINATORORGNDGNDTHERMAL ERRTHERMAL ERROR OUTOR OUTNCNC+ –OFFOFFONONONONOFFOFF SIGNAL GNDSIGNAL GNDPOPOWERWERAC INC INSCSI IDSCSI IDEXT OUTEXT OUTEXT INEXT IN TERMINATERMINATORORGNDGNDTHERMAL ERRTHERMAL ERROR OUTOR OUTNCNC+ –OFFOFFONONONONOFFOFF SIGNAL GNDSIGNAL GNDPOPOWERWERAC INC INSCSI IDSCSI IDEXT OUTEXT OUTEXT INEXT IN TERMINATERMINATORORGNDGNDTHERMAL ERRTHERMAL ERROR OUTOR OUTNCNC+ –OFFOFFONONONONOFFOFFSIGNAL GNDSIGNAL GNDPOPOWERWERAC INC INSCSI IDSCSI IDEXT OUTEXT OUTEXT INEXT IN TERMINATERMINATORORGNDGNDTHERMAL ERRTHERMAL ERROR OUTOR OUTNCNC+ –OFFOFFONONONONOFFOFF 16 1615 1514 1413 1312 1211 1110 109 98 87 76 65 54 432 2 31 1SIGNAL GND 10/100BASE-TSPOT OUTIN EXT STORAGE COPY CONTROL ALARM VIDEOMODED ATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL POWERON AC IN OFFINOUT OUTMULTI SCREEN OUTAUDIO Digital Disk Recorder WJ-HD500A SCSI ID = 6 and 7 Extesion Unit #1 WJ-HDE500 SCSI ID = 5 Extesion Unit #2 WJ-HDE500 SCSI ID = 4 Extesion Unit #3 WJ-HDE500 or WJ-HDE 505* SCSI ID = 3Extesion Unit #4 WJ-HDE500 SCSI ID = 2 Extesion Unit #5 WJ-HDE500 SCSI ID = 1 Extesion Unit #6 WJ-HDE500 SCSI ID = 0 SCSI Cable SCSI Cable SCSI Cable SCSI Cable SCSI Cable SCSI Cable * Use a WJ-HDE505 for the 3rd unit position if additional units are installed. Use a WJ-HDE500 if the 3rd position is the end of the SCSI chain. 1 +– SCSI ID TERMINATOR ON OFF 1 2 3 4 MODE ON
22 Switch Settings 1. Set MODE switch #2 on the rear of the WJ-HD500A to OFF when connecting a DVD Extension Unit without an optional HDD. Set the MODE switch to ON if other Extension Units are installed in the system. 2. Set the SCSI ID and TERMINATION of the Extension Units as required. Connection with the DVD Extension Unit The WJ-HD500A Digital Disk Recorder controls the WJ- HDE510 DVD Extension Unit through the SCSI chain. The figure shows a WJ-HDE510 without an HDD. The DVD-RAM is used for backup of the data recorded on the WJ-HD500A Digital Disk Recorder. 1. Connect between the COPY port on the WJ-HD500A and the COPY IN port on the 1st DVD Extension Unit with the supplied (WJ-HDE510) SCSI cable. Plug the cable end with magnetic core into the COPY port, and the other ends into the COPY IN port. 2. Connect between the EXT STORAGE port on the WJ- HD500A and the EXT IN port on the 2nd Extension Unit with the supplied (WJ-HDE510) SCSI cable. Plug the cable end with magnetic core into the EXT STORAGE port, and the other ends into the EXT IN port. The system can be expanded by up to 6 Extension Units. To connect the other Extension Units, refer to the operating instructions of each unit for further informa- tion. SCSI IDTERMINATOR-+1GNDON OFFSIGNAL AC IN POWEREXT IN COPY IN EXT OUT G NC THERMAL ERROR OUT ON OFFHDDINSTALLED NOT INSTALLED COPY port CONTROL port EXT IN SIGNAL GND POWER AC IN SCSI ID EXT OUTEXT INTERMINATORGNDTHERMAL ERROR OUTNC+ –OFF ONON OFF Terminal boardDVD Extension Unit #1 WJ-HDE510 SCSI ID= not set SCSI cable (supplied with Extension Unit) SCSI cable (supplied) Extension Unit #2 WJ-HDE500/HDE505 SCSI ID=0 to 5 Digital Disk Recorder WJ-HD500A SCSI ID=6 and 7 COPY IN EXT STORAGE 16 1615 1514 1413 1312 1211 1110 109 98 87 76 65 54 432 2 31 1 SIGNAL GND 10/100BASE-TSPOT OUTIN EXT STORAGE COPY CONTROL ALARM VIDEOMODED ATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL POWER ON AC IN OFFINOUT OUTMULTI SCREEN OUTAUDIO 1 2 3 4 MODE ON
23 The figure shows the WJ-HDE510 with an HDD. The DVD-RAM is used for backup of the data recorded on the WJ-HD500A Digital Disk Recorder as well as for storing the data of the extension hard disk drive units in the system. 1. Connect between the COPY port on the WJ-HD500A and the COPY IN port on the 1st DVD Extension Unit with the supplied (WJ-HDE510) SCSI cable. Plug the cable end with magnetic core into the COPY port, and the other ends into the COPY IN port. 2. Connect between the EXT STORAGE port on the WJ-HD500A and the EXT IN port on the 1st DVD Extension Unit with the supplied (WJ-HDE510) SCSI cable. Plug the cable end with magnetic core into the EXT STORAGE port, and the other ends into the EXT IN port. Repeat the connection steps for any subsequent extension units. The system can be expanded by up to 6 Extension Units. To connect the other Extension Units, refer to the operating instructions of each unit for further information. Switch Settings 1. Set MODE switch #2 on the rear of the WJ-HD500A to ON when connecting a DVD Extension Unit with an optional HDD. 2. Set the SCSI ID for the DVD Extension Unit and each subsequent Extension Unit with the – or + selector on the rear of each Unit. 0 to 5:IDs for Extension Units. Note:SCSI ID 6 and 7 are reserved for the WJ-HD500A Digital Disk Recorder. 3. Set the termination switches on the rear of the Extension Units to ON or OFF. ON:Is applied to the extension unit located at the end of the SCSI chain. OFF:Is used for units other than the end unit. SCSI IDTERMINATOR-+1GNDON OFFSIGNAL AC IN POWEREXT IN COPY IN EXT OUT G NC THERMAL ERROROUT ON OFFHDDINSTALLED NOT INSTALLED COPY port CONTROL port SIGNAL GND POWER AC IN SCSI ID EXT OUTEXT INTERMINATORGNDTHERMAL ERROR OUTNC+ –OFF ONON OFF Terminal board SCSI cable (supplied) SCSI cable (supplied) Extension Unit #2 WJ-HDE500/HDE505 SCSI ID=0 to 5 Digital Disk Recorder WJ-HD500A SCSI ID=6 and 7 COPY IN EXT STORAGE EXT IN EXT OUTEXT IN SCSI cable (supplied with Extension Unit) DVD Extension Unit #1 WJ-HDE510 SCSI ID=0 to 5 16 1615 1514 1413 1312 1211 1110 109 98 87 76 65 54 432 2 31 1 SIGNAL GND 10/100BASE-TSPOT OUTIN EXT STORAGE COPY CONTROL ALARM VIDEOMODED ATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL POWER ON AC IN OFFINOUT OUTMULTI SCREEN OUTAUDIO 1 +– SCSI ID ON OFF 1 2 3 4 MODE ON
24 Connection to PS•Data Compatible Equipment Note the following when connecting the Disk Recorder to equipment with PS•Data capability. qConnect the controller and PS •Data equipment at the ends of the PS•Data line. wSet the termination to ON for the units at both ends of the PS •Data line. Use the MODE selector on the rear of the WJ-HD500A Disk Recorder to set the termination. eUse the optional RS-485 cable for connection. Note:To be able to use PS •Data mode, the communication functions need to be set up in the PS•Data SETUP menu. MODE Selector Setting • Set DIP switch 4 of the MODE selector as follows for data termination. ON:If the disk recorder is connected at the end of the PS •Data line. OFF:If the Disk Recorder is not connected at the end of the PS •Data line. Example: • If the optional WJ-HDB502 Network Board is installed as a controller in the Disk Recorder, the system can be controlled from a PC through the Disk Recorder. Set DIP switch 3 of the MODE selector as follows for data termination. ON:If the Network Board is connected at the end of the PS •Data line. OFF:If the Network Board is not connected at the end of the PS •Data line. For a system that has no system controller and is controlled through the Disk Recorder, for example, set DIP switch 3 of the MODE selector to ON position. Note:If the system has a system controller, set DIP switch 3 to OFF position. RS-485 Cable POWER ON OFFALARMData Multiplex Unit WJ-MP204ALARM SUSPEND1234ESC SET RESETSUSPEND SET UPALARM UNIT 0987654321POWER ON OFFALARMData Multiplex Unit WJ-MP204ALARM SUSPEND1234ESC SET RESETSUSPEND SET UPALARM UNIT 0987654321 RS-485 Cable (3 : ON, 4 : OFF) 1234ON ↑ MODE Selector Disk Recorder Data Multiplex Unit Termination : OFFData Multiplex Unit Termination : ON 16 1615 1514 1413 1312 1211 1110 109 98 87 76 65 54 432 2 31 1SIGNAL GND 10/100BASE-TSPOT OUTIN EXT STORAGE COPY CONTROL ALARM VIDEOMODED ATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL POWERONAC INOFFINOUT OUTMULTI SCREEN OUTAUDIO RS-485 Cable POWER ON OFFALARMData Multiplex Unit WJ-MP204ALARM SUSPEND1234ESC SET RESETSUSPEND SET UPALARM UNIT 0987654321 RS-485 Cable System Controller Disk Recorder 16 1615 1514 1413 1312 1211 1110 109 98 87 76 65 54 432 2 31 1SIGNAL GND 10/100BASE-TSPOT OUTIN EXT STORAGE COPY CONTROL ALARM VIDEOMODEDATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL POWERONAC INOFFINOUT OUTMULTI SCREEN OUTAUDIO(3 : OFF, 4 : OFF) 1234ON ↑ MODE Selector System Controller Termination : ONData Multiplex Unit Termination : ON
25 Connection with the PC There are two options to communicate with the PC, the first is using Serial Port and the second is via Ethernet, when the speci- fied Network Board is installed in the Disk Recorder. Serial Port Connection The SERIAL Port on the rear of the Disk Recorder conforms to RS-232C, and it can communicate with the PC by connecting as shown in the figure. 10/100BASE-T Port Connection If the optional Network Board is installed in the WJ-HD500A Disk Recorder, it is enabled control from the PC via Ethernet. Shown in the figure is an example for connection. Hub Personal Computer LAN Hub Digital Disk Recorder 10/100BASE-T Cable (Locally Procured) 16 1615 1514 1413 1312 1211 1110 109 98 87 76 65 54 432 2 31 1 SIGNAL GND 10/100BASE-TSPOT OUTIN EXT STORAGE COPY CONTROL ALARM VIDEOMODED ATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL POWER ON AC IN OFFINOUT OUTMULTI SCREEN OUTAUDIO Personal Computer Digital Disk Recorder D-sub9 D-sub9 or D-sub25 16 1615 1514 1413 1312 1211 1110 109 98 87 76 65 54 432 2 31 1 SIGNAL GND 10/100BASE-TSPOT OUTIN EXT STORAGE COPY CONTROL ALARM VIDEOMODED ATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL POWER ON AC IN OFFINOUT OUTMULTI SCREEN OUTAUDIO4 (ER) 5 (GND) 3 (TXD) 6 (DR) 7 (RTS) 8 (CTS) 2 (RXD) 6 (DR) 7 (GND) 3 (RXD) 20 (ER) 5 (CTS) 4 (RTS) 2 (TXD)PC DB25 WJ-HD500A DB9 1 2 3 4 5 6 7 81 2 3 4 5 6 7 8 WJ-HD500A DB9PC DB9
28 POWER UP PROCEDURE Before operating the Disk Recorder, confirm that the cam- eras and peripherals are connected correctly and securely and all system components are turned on. 1. Turn on the Disk recorder by pressing the POWER switch located on the rear of the Disk Recorder. Make sure that the OPERATE indicator on the front panel is illuminated. 2. After you completed the start, the Disk Recorder will run through a series of instructions for the system on the Multiscreen Monitor. 3. If the Disk Recorder is powered up successfully, the display as shown below appears, then the camera images appear on the monitor screen. [ SYSTEM CHECK ] PLEASE WAIT Note: If during a system check the display shown below appears on the monitor screen, it will be followed by the DISK MENU after five seconds. The DISK MENU-Display indicates the status of the hard disks, and shows the causes why this menu was called up. • Optional Extension Unit is installed [ADD] Requires disk formatting in the Extension Unit. • Replaced Hard Disk [✽] Requires disk formatting for a replaced Hard Disk. • Detached Hard Disk [LOST] Requires disk relocation in the system. • Hard Disk malfunctions [✽] Refer servicing to qualified service per- sonnel. ¢¢GB indicates the hard disk capacity. Note: If the Disk Recorder is left in this state for about five minutes, it will automatically restart by reconfiguring the system (disk remove). Normal camera images will appear on the monitor screen. [ SYSTEM CHECK ] SYSTEM CHECK DONE! PLEASE WAIT DISK MENU: [SETUP] KEY [ SYSTEM CHECK ] YOU HAVE TO CONFIGURE DISKS PLEASE WAIT DISK MENU MAIN 1: ¢¢GB 2:¢¢GB EXT5 1:¢¢GB 2:¢¢GB 3:¢¢GB 4:¢¢GB EXT4 1: * 2: * 3:ADD 4:ADD EXT3 1:LOST 2:LOST 3:LOST 4:LOST EXT2 1:LOST 2:LOST 3:LOST 4:LOST EXT1 1:- 2:- 3:- 4:- EXT0 1:- 2:- 3:- 4:- EXT DVD:- REMOVE FORMAT RESTART SELECT ITEM AND PRESS [SET] KEY
29 FORMATTING THE HARD DISK The Hard Disk requires formatting before it can be used for storing images, as shown below. • When the Hard Disk in the Disk Recorder is replaced. (Disk formatting is required for the replaced Hard Disk.) • When the optional extension units are operated for the first time after installation. (Disk formatting is required for the Hard Disk in the Extension Unit.) Notes: • Remember that by formatting the hard disk all previ- ously recorded data on the disk will be erased. • If the Disk Recorder is set up with the mirroring function, the replaced Hard Disk is automatically copying the data from the other disk of the pair after the disk was formatted. Copying data will take about two hours for a disk with a capacity of 30 GB. Follow the procedures described below to format the Hard Disk in the unit. 1. Power up the Disk Recorder by pressing the POWER switch. 2. The Disk Recorder will run through a series of instruc- tions for the system on the Multiscreen Monitor. The display as shown below appears on the monitor, then the DISK MENU shown below will be displayed after five seconds. [ SYSTEM CHECK ] YOU HAVE TO CONFIGURE DISKS PLEASE WAIT 3. Move the cursor to FORMAT in the menu by pressing the Aor Bbutton, then press the SETbutton. The FORMAT MENU shown below appears on the mon- itor screen. 4. Select the ALL password (5-digit) by pressing the Numeric buttons (1 - 10). Refer to the password setup in the SYSTEM SETUP menu for further details. The factory default setting is 12345. • To select 0 for numeric input, press the numeric 10 button. • Entering an input will automatically check the pass- word. If the password is not correct, PASSWORD ERROR! is displayed on the monitor screen and the display returns to step 2. To enter the password again, repeat procedures 3 and 4. • To quit entering the password, press the SETUP/ ESC button. 5. If the password is correct, the instructions shown below appear in the lower-left corner of the menu. FORMAT MENU MAIN 1: ¢¢GB 2:¢¢GB EXT5 1:¢¢GB 2:¢¢GB 3:¢¢GB 4:¢¢GB EXT4 1:ADD 2:ADD 3:ADD 4:ADD EXT3 1:- 2:- 3:- 4:- EXT2 1:- 2:- 3:- 4:- EXT1 1:- 2:- 3:- 4:- EXT0 1:- 2:- 3:- 4:- EXT DVD:- PASSWORDB----- FORMAT MENU MAIN 1: ¢¢GB 2:¢¢GB EXT5 1:¢¢GB 2:¢¢GB 3:¢¢GB 4:¢¢GB EXT4 1:ADD 2:ADD 3:ADD 4:ADD EXT3 1:- 2:- 3:- 4:- EXT2 1:- 2:- 3:- 4:- EXT1 1:- 2:- 3:- 4:- EXT0 1:- 2:- 3:- 4:- EXT DVD:- 1DISK ALL ALL MIRROR RESTART SELECT ITEM AND PRESS [SET] KEY DISK MENU MAIN 1: ¢¢GB 2:¢¢GB EXT5 1:¢¢GB 2:¢¢GB 3:¢¢GB 4:¢¢GB EXT4 1:ADD 2:ADD 3:ADD 4:ADD EXT3 1:- 2:- 3:- 4:- EXT2 1:- 2:- 3:- 4:- EXT1 1:- 2:- 3:- 4:- EXT0 1:- 2:- 3:- 4:- EXT DVD:- REMOVE FORMAT RESTART SELECT ITEM AND PRESS [SET] KEY
30 6. Select either 1DISK or ALL by pressing the Aor B button, then press the SETbutton. 1DISK:Enables formatting only a specified Hard Disk. ALL: Enables formatting all Hard Disks. If the 1DISK is selected in the menu, move the cursor to the Hard Disk number to be formatted by pressing the A, B, Dor Cbutton, then press the SETbutton. The instructions appear in the lower-left corner of the menu, as shown below. 7. Select YES in the menu by pressing the Aor B but- ton, then press the SETbutton to start formatting. 8. When the formatting is completed, FORMAT DONE! appears in the lower center of the menu. • Then the menu display will return to step 6 for for- matting another Hard Disk. Repeat the procedure 6 to 8 to format the another disk. • To quit formatting, move the cursor to RESTART in the menu by pressing the A, B, Dor Cbutton, then press the SETbutton to restart the Disk Recorder. Normal camera images will appear on the monitor. • Normal camera images will appear on the monitor after five seconds. 1DISK FORMAT MAIN 1: ¢¢GB 2:¢¢GB EXT5 1:¢¢GB 2:¢¢GB 3:¢¢GB 4:¢¢GB EXT4 1:ADD 2:ADD 3:ADD 4:ADD EXT3 1:- 2:- 3:- 4:- EXT2 1:- 2:- 3:- 4:- EXT1 1:- 2:- 3:- 4:- EXT0 1:- 2:- 3:- 4:- EXT DVD:- EXECUTE? YES NO SELECT YES/NO AND PRESS [SET] KEY 1DISK FORMAT MAIN 1: ¢¢GB 2:¢¢GB EXT5 1:¢¢GB 2:¢¢GB 3:¢¢GB 4:¢¢GB EXT4 1:ADD 2:ADD 3:ADD 4:ADD EXT3 1:- 2:- 3:- 4:- EXT2 1:- 2:- 3:- 4:- EXT1 1:- 2:- 3:- 4:- EXT0 1:- 2:- 3:- 4:- EXT DVD:- FORMAT DONE!
31 4. Select DVD FORMAT in the menu by pressing the Dor Cbutton, then press the SET button. The DVD FORMAT menu as shown below appears on the monitor. 5. Select YES in the menu by pressing the Aor Bbut- ton, then press theSETbutton to start formatting. 6. When the formatting is completed, COMPLETED! appears in the center of the menu. 7. To exit from the menu, press and hold the SETUP/ESC button for two seconds or more. FORMATTING THE DVD-RAM DISK The DVD-RAM Disk requires formatting before it can be used for storing images when the DVD Extension Unit is installed in the system for backup of the recording data. Notes: • Remember that by formatting the DVD-RAM disk all previously recorded data on the disk will be erased. • Confirm that the AUTO COPY (EVENT) and AUTO COPY (EMERGENCY) parameters in the DVD menu are set to OFF. Otherwise disk formatting is disabled. Follow the procedures described below to format the DVD- RAM Disk in the unit. 1. Insert the DVD-RAM disk into the DVD Extension Unit. 2. Press and hold the SETUP/ESCbutton for two seconds or more to display the WJ-HD500 SETUP menu on the screen of the Multiscreen Monitor. 3. Select DVD in the menu by pressing the Dor Cbutton, then press the SETbutton. The DVD menu as shown below appears on the moni- tor. WJ-HD500 SETUP *.** TIMER OFF REC SETUP COMMON SETUP *MANUAL WITHOUT AUDIO *TIMER WITHOUT AUDIO *EMERGENCY WITHOUT AUDIO MULTIPLEXER SETUP ALARM SETUP DISPLAY SETUP COMMUNICATION SETUP SYSTEM SETUP DVD 10 DVD DVD FORMAT *AUTO COPY(EVENT) OFF AUTO COPY(EMERGENCY) OFF DVD DISKEND STOP DVD FULL 1% 10-1 DVD FORMAT EXECUTE? YES NO 10-1 DVD FORMAT COMPLETED! 10-1 DVD FORMAT FORMATTING! DONT TURN OFF THE POWER