Have a look at the manual Panasonic Digital Disk Recorders Wj Hd316 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
71 ■ Connections with DVD-RAM, CD-R, and DVD-R drives This is an example of connection when the unit is used together with the designated DVD-RAM, DVD-R and CD-R drive. Connect the designated DVD-RAM, DVD-R and CD-R drive and the COPY1 port on the rear panel or the COPY2 port inside the connectors cover on the front panel of this unit using an USB cable (not included). Important: •Use an appropriate USB cable compatible with the USB2.0 standard. •Fix the cables with the cable clamp (provided with this unit) to prevent disconnection or unstable connections that may cause recording failures or an unstable system. ALARMTIMER HDD 2 ERROR HDD 1 ALARM SUSPEND OPERATE LOGOUT MONITOR1 MONITOR2 5 9 2 6 10 / 0 14 13 3 7 11 SHIFT SEQ COPYDISK SELECT EL-ZOOM TEXT LOGOUT 4 8 12 OSD MARK 1 15 16BUSY REV FWDSTOPPLAY PAUSEREC - REC STOP SEARCH SETUP /ESCPA N / T I LTSLOWA-B REPEATGOTO LAST LISTED ZOOM/ FOCUS IRIS PRESET /AUTO SET – +ALARM RESET S-VIDEO COPY 2VIDEO OUT AUDIO OUT 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 PA N / TILT Rear Front Designated DVD-RAM drive, etc. USB cable (Locally procured) Designated DVD-RAM drive, etc.USB cable (Locally procured) ROM ROM Cable Clamp Fixing screw 2 21 1 COPY EXIT STORAGE 10/100BASE-T How to fix the cable clamp
72 ■ Connections with the VCR When it is necessary to copy the recorded images to a video tape using a VCR, connect the VCR to the S-VIDEO connector (or the VIDEO OUT connector) and the AUDIO OUT connector inside the connectors cover on the front panel of this unit as below. Note:The same video signal supplied to the MONITOR1 connector and to the MONITOR2 (VGA) connector will be supplied to the S-VIDEO connector and the VIDEO OUT connector inside the connectors cover. The same audio signal supplied to the AUDIO OUT connector on the rear panel of this unit will be supplied to the AUDIO OUT connector inside the connectors cover on the front panel. VCR Open the terminal cover. ALARMTIMER HDD 2 ERROR HDD 1 ALARM SUSPEND OPERATE LOGOUT MONITOR1 MONITOR2 5 9 2 6 10 / 0 14 13 3 7 11 SHIFT SEQ COPYDISK SELECT EL-ZOOM TEXT LOGOUT 4 8 12 OSD MARK 1 15 16BUSY REV FWDSTOPPLAY PAUSEREC - REC STOP SEARCH SETUP /ESCPA N / T I LTSLOWA-B REPEATGOTO LAST LISTED ZOOM/ FOCUS IRIS PRESET /AUTO SET – +ALARM RESET S-VIDEO COPY 2VIDEO OUT AUDIO OUTPA N / TILT AUDIO IN S-IN terminalOrdinary audio cable (with a RCA pin plug) Ordinary audio cable (with a RCA pin plug) VIDEO IN
73 ■ Connections with PS·Data systems This is an example of connection when the unit is used together with the PS·Data devices. If a connected system controller is PS·Data compatible, it is possible to operate this unit or connected devices using the sys- tem controller. Use the RS485 cable provided with the system controller. Important: •Terminate both devices on both ends of the connection. Refer to the respective operating instructions for the descriptions of how to terminate. Termination of this unit can be set with the mode switch on the rear panel. (See below.) •When connecting a PS·Data compatible device, it is necessary to set each item of PS·Data Setup of Comm on the SETUP MENU according to the system configuration. •The PS·Data is our exclusive protocol. Contact dealer about devices that can be connected. ● When this unit is installed between the controller and the system device (when this unit is used as a receiver) System Controller Controller Termination: ON Unit Address : 1RS485 cable (provided with the controller) Mode switch (No. 8: ON) 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 PS·Data setup of Comm on the SETUP MENU • Unit Address (System) : 1 • Unit Address (Controller) : 2 678 12345 ON
74 ● When this unit is connected with the system device (when this unit is used as a controller) POWER ON OFFALARM Data Multiplex Unit WJ-MP204 ALARM SUSPEND1234ESC SET RESETSUSPEND SET UPALARM UNIT 0987654321 System Controller Controller Termination: ON Unit Address : 2RS485 cable Mode switch (No.8 : OFF) Coaxial communication unit Termination: ON Unit Address : 1 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 678 12345 ON PS·Data setup of Comm on the SETUP MENU • Unit Address (System) : 1 • Unit Address (Controller) : 2 POWER ON OFFALARM Data Multiplex Unit WJ-MP204 ALARM SUSPEND1234ESC SET RESETSUSPEND SET UPALARM UNIT 0987654321 POWER ON OFFALARM Data Multiplex Unit WJ-MP204 ALARM SUSPEND1234ESC SET RESETSUSPEND SET UPALARM UNIT 0987654321RS485 cable Mode switch (No. 7: ON) 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 678 12345 ON Coaxial communication unit Termination: ON Unit Address : 3 Coaxial communication unit Termination: OFF Unit Address : 2 PS·Data setup of Comm on the SETUP MENU • Unit Address (System) : 1 • Unit Address (Controller) : 1
75 ■ Cascade connection of multiple units Up to of four units can be connected. For the cascade connection, connect the CASCADE IN connector and the CASCADE OUT connector on the rear panel of each unit as below. Important: •When connecting the unit in the cascade connection, set Cascade of PS·Data Setup in Comm on the SETUP MENU to ON. (Page 115) •It is impossible to use this connector when connecting the unit in the cascade connection. ● When no PS·Data compatible device is connected to the system Monitor 1 First unit (this unit) System : 1 Controller : 1 Second unit System : 2 Controller : 2 Third unitSystem : 3 Controller : 3 Monitor 2 Mode switch (No. 7: ON) 678 12345 ON Mode switch (No. 8: OFF) 678 12345 ON Mode switch (No. 8: ON) 678 12345 ON 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 Unit Address settings of PS·Data Setup of Comm on the SETUP MENU RS485 Cable BNC Cable (Locally procured)BNC Cable (Locally procured) BNC Cable (Locally procured)RS485 Cable
76 ● When the PS·Data compatible device is connected to the first unit (when this unit is used as a receiver) 12 IN OUT CASCADE OUT 16 16 3 15 15 1414 132 1 13 1212 1111 1010 99 88 77 66 55 44 33 22 11 VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 1 2 IN OUT CASCADE OUT 16 16 3 15 15 1414 132 1 13 1212 1111 1010 99 88 77 66 55 44 33 22 11 VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 1 2 IN OUT CASCADE OUT 16 16 3 15 15 1414 132 1 13 1212 1111 1010 99 88 77 66 55 44 33 22 11 VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 System ControllerMonitor 1 First unit (this unit) System : 1 Controller : 2 Second unit System : 2 Controller : 3 Third unit System : 3 Controller : 4Monitor 2 Mode switch (No. 8: OFF) 678 12345 ON Mode switch (No. 8: OFF) 678 12345 ON Mode switch (No. 8: ON) 678 12345 ON Controller Termination: ON Unit Address : 1 RS485 cable RS485 cable RS485 cable Unit Address settings of PS·Data Setup of Comm on the SETUP MENU BNC Cable (Locally procured) BNC Cable (Locally procured) BNC Cable (Locally procured)(provided with the controller)
77 ● When the PS·Data compatible device is connected to the third unit (when this unit is used as a receiver) 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 Monitor 1 First unit (this unit) System : 1 Controller : 1 Second unit System : 2 Controller : 2 Third unit System : 3 Controller : 3 PS · Data Compatible Monitor 2 Mode switch (No. 7: ON) 678 12345 ON Mode switch (No. 8: OFF) 678 12345 ON Mode switch (No. 8: OFF) 678 12345 ON POWER ON OFFALARM Data Multiplex Unit WJ-MP204 ALARM SUSPEND1234ESC SET RESETSUSPEND SET UPALARM UNIT 0987654321 Coaxial communication unit Termination: ON Unit Address settings of PS·Data Setup of Comm on the SETUP MENU RS485 cable RS485 cable RS485 cable BNC Cable (Locally procured) BNC Cable (Locally procured)BNC Cable (Locally procured) BNC Cable (Locally procured)
78 ● When the PS·Data compatible devices are connected to the first and third units (when this unit is used as a receiver) 12 IN OUT CASCADE OUT 16 16 3 15 15 1414 132 1 13 1212 1111 1010 99 88 77 66 55 44 33 22 11 VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 1 2 IN OUT CASCADE OUT 16 16 3 15 15 1414 132 1 13 1212 1111 1010 99 88 77 66 55 44 33 22 11 VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 1 2 IN OUT CASCADE OUT 16 16 3 15 15 1414 132 1 13 1212 1111 1010 99 88 77 66 55 44 33 22 11 VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 POWER ON OFFALARM Data Multiplex Unit WJ-MP204 ALARM SUSPEND1234ESC SET RESETSUSPENDSET UPALARM UNIT 0987654321 Monitor 1 First unit (this unit) System : 1 Controller : 2 Second unit System : 2 Controller : 3 Third unit System : 3 Controller : 4Monitor 2 Mode switch (No. 8: OFF) 678 12345 ON Mode switch (No. 8: OFF)678 12345 ON Mode switch (No. 8: OFF)678 12345 ON Coaxial communication unit Termination: ON System Controller RS485 cable Controller Termination: ON Unit Address: 1 PS · Data Compatible PS · Data application RS485 cable RS485 cable RS485 cableUnit Address settings of PS·Data Setup of Comm on the SETUP MENU BNC Cable (Locally procured)BNC Cable (Locally procured) BNC Cable (Locally procured) BNC Cable (Locally procured)(provided with the controller)
79 ■ Connection with the RS485 camera This is an example of connection when the unit is used together with the RS485 devices. Up to eight cameras can be connected using a single RS485 (CAMERA) port. Important: •Terminate both devices on both ends of the connection. Refer to the respective operating instructions for the descriptions of how to terminate. Termination of this unit can be set with the mode switch on the rear panel. •When connecting an RS485 camera, it is necessary to set each item of RS485 Setup of Comm on the SETUP MENU according to the RS485 settings of the camera. (Refer to page 116.) •The total length of the RS485 cable from this unit is 1 200 meters at the maximum. ● 1:1 connection Connect a camera to the RS485 (CAMERA) port. Example: When the RS485 cameras are connected to the CAMERA IN connectors 9 and 13: IN OUT CASCADE OUT 16 16 415 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1CAMERA AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY MODEEXIT STORAGE 10/100BASE-T RS-485(CAMERA)PS·DATA AC IN SIGNAL GND1 32 RS485 cable RS485 cable Mode switch (No. 1, No. 4 : ON) 678 12345 ON Combination Camera Connect the RS485 camera to Switches required to be set 4-wire communication 2-wire communication RS485 (1) RS485 (2)No.2 No.3 No.5 No.6OFF OFF OFF OFFON ON ON ON
80 ● Daisy connection Multiple cameras can be connected to the RS485 (CAMERA) port. Example: When cameras 1 - 4 are connected to one of the RS485 (CAMERA) port and cameras 9 - 12 are connected to the other RS485 (CAMERA) port. 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATA AC IN SIGNAL GND1 42 RS485 cable Mode switch Nos. 1,2,3,4,5,6 : ON 67 8 12345 ON Unit No. 10 Termination: OFF Unit No. 11 Termination: OFF Unit No. 12 Termination: ONUnit No. 9 Termination: OFF Unit No. 2 Termination: OFF Unit No. 3 Termination: OFF Unit No. 4 Termination: ONUnit No. 1 Termination: OFF Connect the RS485 camera to Switches required to be set 4-wire communication 2-wire communication RS485 (1) RS485 (2)No.2 No.3 No.5 No.6OFF OFF OFF OFFON ON ON ON