Home
>
Panasonic
>
Recording Equipment
>
Panasonic Digital Disk Recorders Wj Hd316 Operating Instructions
Panasonic Digital Disk Recorders Wj Hd316 Operating Instructions
Have a look at the manual Panasonic Digital Disk Recorders Wj Hd316 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
141 •When an ANSWER command is required The unit sends back the status or data, as shown in the figure. •About ACK code After receiving an command from the PC, the unit sends back the ACK code to the PC in 20 ms or less. [ACK] = Reception succeeded (ASCII code: 06H) After the ACK code sending back and the command processing has completed, the unit sends back the response com- mand to the PC. Example: These are examples for the following operations. 1. Login with the user name of ADMIN and with password of 12345. 2. Display images from the camera channel 1 on the monitor 2. 3. Start playback from the point of January 1 2003, 3:00 p.m. 4. Logout (1) (This unit -> PC) Login [STX]AD001;OLI:ADMIN[SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP]:12345[SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP][ETX] When receiving the command above, this unit will start the login procession of the user name of ADMIN. (2) (This unit -> PC) Response against (1). [STX]AD001;OLI:1[ETX] (3) (PC -> This unit) Select the monitor 2 [STX]AD001;OMS:001[ETX] (4) (This unit -> PC) Response against (3). [STX]AD001;OLI:1[ETX] (5) (PC -> This unit) Display images from the camera channel 1. [STX]AD001;OCS:00001[ETX] (6) (This unit - > PC) Response against (5). [STX]AD001;OCS:00002[ETX] (7) (PC -> This unit) Playback from the designated time point. [STX]AD001;ZTP:20030101150000[ETX] When receiving the command above, this unit will start playback from the point of January 1 2003, 3:00 p.m. (8) (This unit - > PC) Response against (7). [STX]AD001;ZTP: 200301011500000[ETX] [STX] [ETX]QOP Status inquiry command Status information command Transmission command (→ The unit) Response command (← The unit) [STX] [ETX]OPL [STX] [ETX]QRV Version inquiry command Sends back data. Transmission command (→ The unit) Response command (← The unit) [STX] [ETX]QRV:1.01:1.01:1.00:1.10
142 •Parameter error When the unit cannot properly process the received command, the unit sends back an error code to the PC. After clearing the receive buffer, the unit enters the wait state until receiving the following [STX] command. •If the unit receives another command during the response, the unit will respond to the command after processing the cur- rent response. •If the unit received the [STX] command again before receiving the [ETX] command, the unit will clear the internal buffer. Then, the unit will process the data following to the [STX] command. (The commands received before the second [STX] command will be canceled.) •The internal buffer will be cleared when it fills up.* Reason for the error 001: Command invalid (There is no associated command.) 002: Parameter invalid (The number, digit, or range of the command parameters is incorrect.) 003: Command invalid (The unit does not support the operation mode.) E: Command error (ASCII code: 45H) ERN[ETX] =Error (9) (PC -> This unit) Logout. [STX]AD001;OLO [ETX] When receiving the command above, the user logged in via SERIAL (RS232C) (ADMIN) will logout. ( 10)(This unit - > PC) Response against (9). [STX]AD001;OLO[ETX] Note: The character code of [STX], [ETX] and [SP] are as follows. [STX]: 02h [ETX]: 03h [SP] (space): 20h 3. Reception Error The response command differs between the reception error and parameter error. •Communication error (Reception error) When the unit cannot properly receive the command due to the communication error, the unit immediately sends back the NACK code to the PC. After clearing the receive buffer, the unit enters the wait state until receiving the following [STX] command. [NCK] = Reception failed (ASCII code: 15H) Reason for the communication error 1: Parity error (ASCII code: 31H) 2: Framing error (ASCII code: 33H) 3: Overrun error (ASCII code: 34H) N
143 1 2 IN OUT CASCADE OUT 16 16 315 1514 1413 2 113 12 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTOROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC IN SIGNAL GND1 42 D-sub Pin 9 (Female)D-sub Pin 9 (Female) This unitPersonal compute Pin No. Signal Name I/O 1CDIN 2TXD IN 3RXD OUT 4DTR OUT 5SG– 6DSR IN 7RTS OUT 8CTS IN 9RIIN WJ-HD316 Rear View 51 96 7 (RTS) 8 (CTS) 3 (TXD) 5 (GND) 2 (RXD)7 (RTS) 8 (CTS) 3 (TXD) 5 (GND) 2 (RXD) WJ-HD316 PC or another device Cross cable connection example 4. PC Connection Example RS232C crossing cable is used for connection between the unit and PC. (Refer to the following page for cable specification.)
144 Basic Operation Item Forward a field Rewind a field Pause during playback Play Manual recording Manual recording with text Stop Skip & play forward Skip&play reversely Record No. Search and playback Time & date search and playback Record skip LISTED Playback Playback latest image A - B repeat playback Display COPY SETUP MENU Display text Multi-screen switching Monitor selection Camera selection Transmission command (ASCII) OVF OVR OPA OPL ORC ZMR:nn:ddd... ddd OSP:n OSF:n OSR:n ZPR:rrrrrrrrrrrrrrrr:mm ZTP:yyyymmddhhnnss OSK:dnn ZLT:n ZPM ZRP:n ZPD:n ZDT:n OTC:m OMS:nnnn OCS:ccccc Response command (ASCII) OVF OVR OPA OPL ORC ZMR:nn OSP OSF OSR ZPR:rrrrrrrrrrrrrrrr ZTP:yyyymmddhhnnss OSK ZLT:n ZPM ZRP:n:yyyymmddhhnnss ZPD:n ZDT:n OTC:m OMS:nnnn OCS:ccccc Parameter (ASCII) nn=01~99 (Sequence number) ddd... ddd: text (200 bytes or less) n=P: Stops PLAY n=R: Stops REC no parameter stops PLAY and REC n=0F Normal speed n=1F x2 speed n=2F x5 speed n=3F x10 speed n=4F x20 speed n=5F x50 speed n=6F x100 speed n=0S Normal speed n=1S 1/2 speed n=0F Normal speed n=1F x2 speed n=2F x5 speed n=3F x10 speed n=4F x20 speed n=5F x50 speed n=6F x100 speed n=0S Normal speed n=1S 1/2 speed rrrrrrrrrrrrrrrr Record No. yyyymmddhhnnss:Time & date of playback image d=+ Forward – Backward nn=01 Number of skipped records: Fixed n=0 OFF n=1 ON n=0 A - B repeat playback OFF n=1 Set repeat start point (A point) n=2 Set repeat end point (B point) yyyymmddhhnnss: Date and time of A/B point n=0 COPY SETUP MENU OFF n=1 COPY SETUP MENU ON n=0 Text display OFF n=1 Text display ON m=0 4-split screen m=1 7-split screen m=2 9-split screen m=3 10-split screen m=4 13-split screen m=5 16-split screen nnnn=0001 Select MON 1 nnnn=0002 Select MON 2 ccccc: Camera CH ●Command Table
145 Item Start sequence Stop sequence Disk selection Marking Alarm Control Item Alarm input Alarm input with text Alarm reset Alarm suspension Alarm change information (LED indication) Alarm change information Setup Control Item Display SETUP MENU Transmission command (ASCII) MSU:n DCR:n1n2 TSU:yyyymmddhhnn MST:n MRM:n Response command (ASCII) MSU:n DCR TSU MST MRM Parameter (ASCII) n=0 SETUP MENU OFF n=1 SETUP MENU ON n1n2=A1 Right n1n2=C1 Upward n1n2=E1 Left n1n2=G1 Downward n1n2=+1 Increment parameter (+) n1n2=-1 Decrement parameter (–) n1n2=PD Move to virtual menu (SET) n1n2=P- Go back to an older page (BACK) n1n2=PU Move to upper layer (ESC) yyyymmddhhnn: Date and time n=0 Standard time n=1 Summer time n=0 Normal recording mode n=2 Continuous (External timer) recording mode Transmission command (ASCII) OQT:01F OQS:0 ZDS:k ZMP Transmission command (ASCII) OAI:b1b2b3a1a2a3a4 ZAI:b1b2b3a1a2a3a4: nn:ddd... ddd OAL;n MAD:n – – Response command (ASCII) OQT:01F:01 OQS ZDS:k ZMP Response command (ASCII) OAI ZAI:nn OAL MAD:n ALD:n ALM: b 1b2b3a1a2a3a4 Parameter (ASCII) b1b2b3: Head alarm CH information (binary) a 1a2a3a4: Alarm CH information (binary) b 1b2b3: Head alarm CH information (binary) a 1a2a3a4: Alarm CH information (binary) nn=01 - 99 (Sequence No) ddd... ddd: text (200 bytes or less) n=0 Alarm all reset n=1 Alarm reset n=0 Alarm suspension OFF n=1 Alarm suspension ON) n=0 LED OFF n=1 LED ON n=2 LED Blinking b1b2b3: Head alarm CH information (binary) a1a2a3a4: Alarm CH information (binary) Parameter (ASCII) k=0 HDD normal/event recording sector k=1 HDD copy sector k=2 Disk connected to COPY 1 k=3 Disk connected to COPY 2) Electronic zooming OZM:m OZM:n m=0 Electronic zooming OFF m=1 Electronic zooming ON m=> Switch x2 -> x4 m=< Switch x4 -> x2 m=+ Switch Electronic zooming OFF -> x2 -> x4 -> Electronic zooming OFF -> ... m=- Switch x4 -> x2 -> Electronic zooming OFF -> x4 -> ... n=0 Electronic zooming OFF n=2 x2 n=4 x4 term Move cursor Date & Time setup Summer time setup Recording mode setup Login/Logout Item Login Logout Transmission command (ASCII) OLI:uuu...uuu: ppp... ppp OLO Response command (ASCII) OLI:n OLO Parameter (ASCII) uuu...uuu: User name (32-byte fixed length) ppp...ppp: Password (32-byte fixed length) n=0 Error in user name/password n=1 Login succeeded n=2 Login failed
146 Data Control Item Copy by specifying record Copy by specifying date & time Data copy completed Cancel data copy Erase log Log data total number inquiry Log readout Record list acquisition Text acquisition Text writing Disk End Notification Item Disk end auto-notification setting Disk end auto-notification Transmission command (ASCII) MDE:n HDE:– Response command (ASCII) MDE:n HDE:p Parameter (ASCII) n=0 (Auto-notification OFF) n=1 (Auto-notification ON) p=1 (Normal recording sector) p=2 (Event recording sector) p=3 (Copy sector) Transmission command (ASCII) ZCR:rrrrrrrrrrrrrrrr:m ZCT:y 1y1y1y1m1m1d1d1h1h1n1n1:y2y2y2y2m2m2d2d2h2h2n2n2:s:ccc:m – ZDC ZLC:k ZLQ:k:y 1y1y1y1m1m1d1d1h1h1n1n1:y2y2y2y2m2m2d2d2h2h2n2n2 ZLR:yyyymmdd hhnn:mmmmmmmm ZGR:yyyymmddnn :nnnnnnnn ZGT:rrrrrrrrrrrrrrrr ZPT:rrrrrrrrrrrrrrrr: Response command (ASCII) ZCR ZCT ZEC:y 1y1y1y1m1m1d1d1h1h1n1n1: y 2y2y2y2m2m2d2d2h2h2n2n2:s:ccc:m ZDC ZLC:k ZLQ:k:y 1y1y1y1m1m1d1d1h1h1n1n1y2y2y2y2m2m2d2d2h2h2n2n2:dddddddd ZLR:k:s1:s2:... :sn ZGRs1:s2:... :sn ZGT:rrrrrrrrrrrrrrrr: ZPT:rrrrrrrrrrrrrrrr Parameter (ASCII) rrrrrrrrrrrrrrrr: Record No. m=0 Copy to HDD copy sector m=1 Copy to media connected to COPY 1 m=2 Copy to media connected to COPY 2 y 1y1y1y1m1m1d1d1h1h1n1n1: Start date & time of data copy y 2y2y2y2m2m2d2d2h2h2n2n2: End date & time of data copy s=0 Format to specify the camera CH. Fixed to 0 ccc: Camera CH No. of target for data copy m=0 Copy to HDD copy sector m=1 Copy to media connected to COPY 1 m=2 Copy to media connected to COPY 2 y 1y1y1y1m1m1d1d1h1h1n1n1 Start date & time of data copy y 2y2y2y2m2m2d2d2h2h2n2n2End date & time of data copy s=0 Format to specify the camera CH. Fixed to 0 ccc: Camera CH No. of target for data copy m=0 Copy to HDD copy sector m=1 Copy to media connected to COPY 1 m=2 Copy to media connected to COPY 2 k=1 Event input log k=2 Trouble log k=3 Access log k=0 Record list k=1 Event input log k=2 Trouble log k=3 (Access log) y 1y1y1y1m1m1d1d1h1h1n1n1: Start date & time of inquiry range y 2y2y2y2m2m2d2d2h2h2n2n2: End date & time of inquiry range dddddddd: Log data total number k=1 (Event input log) k=2 (Trouble log) k=3 (Access log) yyyymmddhhnn Start date & time of readout logs mmmmmmmm: Total number of acquired logs (00000000 - 00000050) : Log data sn: 0-9 Cyclic number yyyymmddhhnn: Start date & time of readout list mmmmmmmm: Total record number in the acquired list (00000001 - 00000050) : Log data sn: 0-9 Cyclic number rrrrrrrrrrrrrrrr: Record No. : text data rrrrrrrrrrrrrrrr: Record No. : text data 200 bytes or less
147 Search Operation Item Display search editing area Display Operation Item Switch display Inquiry Item Additional disk space inquiry ID request Interface ID request Production category request Alarm information request Software version inquiry Status inquiry Transmission command (ASCII) Transmission command (ASCII) QHR:p QID QIB QIC QLD:0 QRV QSR DIN:n Response command (ASCII) Response command (ASCII) QHR:p:sss QID:WJ-HD309 or QID:WJ-HD316 QIB:WJ-HD309 or QIB:WJ-HD316 QIC:2 QLD:n QRV:n.nn QSR:Status 1:Status 2...n=0 (No alarm) n=1 (Alarm end) n=2 (Under alarm operation) n.nn: Software version Following response commands are sends back for Status 1:Status 2... msu:0 Under normal operation msu:1 Under setting oms:0001 Monitor 1 oms:0002 Monitor 2 ocs:ccccc ccccc: Camera number otc:n Multiscreen segment display pattern n=0: 4 segments n=1: 7segments n=2: 9 segments n=3: 10 segments n=4: 13 segments n=5: 16 segments oqt: 01F Sequence activated ozm: 0 Zoom OFF ozm: 2 x2 zoom ozm: 4 x4 zoom mad: 0 Alarm suspension OFF mad: 1 Alarm suspension ON zcd: Cascade activated zqs: 1 CH recording activated:2 CH recording activated... 16 CH recording activated Recording status nn=00 (Recording stop) nn=01 (Manual recording activated) nn=02 (Event recording activated) nn=03 (Schedule recording activated) nn=04 (Emergency recording activated) DIN Parameter (ASCII) Parameter (ASCII) p=1 HDD normal recording sector p=2 HDD event recording sector p=3 HDD copy sector p=4 Disk connected to COPY 1 p=5 Disk connected to COPY 2 sss: Additional disk space (%) n=+ Transmission command (ASCII) ZTL:n Response command (ASCII) ZTL:n Parameter (ASCII) n=0 (Search editing area OFF) n=1 (Recording event search list ON) n=2 (Recording event search thumbnail ON) n=3 (VMD search list ON) n=4 (VMD Search Thumbnail OFF) n=5 (Marking search list ON) n=6 (Marking search thumbnail ON) n=7 (Search playback display ON)
148 zqm: Monitor status: camera CH: Playback time Monitor status n=0 Live n=1 Live sequence n=2 Playback n=3 Other statuses Camera CH Playback time: yyyymmddhhnnss ztl:n Search editing area ON n=0 Search editing area OFF n=1 Recording event search list ON n=2 Recording event search thumbnail ON n=3 VMD search list ON n=4 VMD search thumbnail ON n=5 Marking search list ON n=6 Marking search thumbnail ON n=7 Search playback display ON zdt:0 Text display OFF zdt:1 Text display ON Recording mode inquiry Monitor status inquiry Recording status inquiry Record number informa- tion Camera SYNC status inquiryQRM ZQM ZQS – QSY:a1a2a3a4a5 :b1b2b3b4b5QRM:n ZQM:m:a 1a2a3a4:yyyy mmddhhnnss ZQS:1 CH recording activated: 2 CH recording activated... 16 CH recording activated ZRN:sss:nn:rrrrrrrrrrrrrrrr :nnyyyymmddhhnnss: ccc:x;yyy:t QSY:a 1a2a3a4a5b1b2b3b4b5:s1s2s3... smn=0 Normal recording mode n=2 Continuous (External timer) recording mode m=0 Live m=1 Live sequence m=2 Playback m=3 Other statuses a 1a2a3a4: Camera CH information (binary) yyyymmddhhnnss: Playback time Recording status nn=00 (Recording stop) nn=01 (Manual recording activated) nn=02 (Event recording activated) nn=03 (Schedule recording activated) nn=04 (Emergency recording activated) sss: Unit address nn=Sequence number rrrrrrrrrrrrrrrr: Record number yyyymmddhhnnss: Recording event date and time ccc: Camera CH x=0 Manual recording x=1 Schedule recording x=2 VMD recording x=3 Alarm port recording x=4 Command alarm recording x=5 VIDEO LOSS recording x=6 Emergency recording yyy: Event-activated CH t=0 Text included t=1 Text not included nn=Sequence number a 1a2a3a4a5- b1b2b3b4b5: Range of camera CH to inquire SYNC status s 1s2s3... sm: SYNC status of each camera (s m=0: SYNC status not found s m=1: SYNC status found) Item Transmission command (ASCII) Response command (ASCII) Parameter (ASCII)
149 Communication Item Communication check Transmission command (ASCII) RCK Response command (ASCII) RCK Parameter (ASCII) Record information inquiryZGP:rrrrrrrrrrrrrrrr ZGP:rrrrrrrrrrrrrrrr: ccc:q:nnnn:yyyymmdd hhnnss:nnss:t:ssssssrrrrrrrrrrrrrrrr: Record number ccc: Camera CH q: picture quality (0 (Very Fine), 1 (Fine), 2 (Normal), 3 (Extended)) nnnn: Recording rate yyyymmddhhnnss: Recording start date and time nnss: Recording total time t=0 Text included t=1 Text not included ssssss: Record size [KB] Item Transmission command (ASCII) Response command (ASCII) Parameter (ASCII)
150 FLOWCHART OF THE SETUP MENU Recording Emergency REC Recording REC Setup Maintenance REC Rate Maintenance Disk Info Maintenance Version info Maintenance Disk End Mode Maintenance Disk Capacity Maintenance Disk Delete Maintenance Error Log Maintenance Access Log Maintenance Event LogEvent Event SetupSchedule Time Table Maintenance Monitor 1Display OSD Setup Comm Camera ControlSystem Basic Setup System Time & Date System User Regist. System User Edit System User Delete System Host Regist. System Host Edit System Host Delete System User Level System Save/Load Time & Date Summer Time (Day Light Saving) Ta b l e Comm PS·Data Setup Comm RS485 Setup Comm RS232 Setup Comm NW Setup 1 Comm NW Setup 2 Comm NTP SetupRS485 Setup Control Camera CH PS·Data Setup Camera Number Setup Display Monitor 1 Display Monitor 2 OSD Setup Camera Title Monitor 1 Live Sequence Maintenance Monitor 2 Monitor 2 Live Sequence Schedule REC PROGRAM Schedule EVENT PROGRAM Schedule Special Days REC PROGRAM Recording Program EVENT PROGRAM Event Program Event Program VMD Event Program Video Loss Event Program Terminal/Command Alarm Event Setup VMD Event Setup Video Loss Event Setup Terminal/Command Alarm VMD Area Setup For each camera Event VMD Setup Event Alarm Setup Event Terminal Setup