Have a look at the manual Panasonic Digital Disk Recorder Wj Hd616 Wj Hd716 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
81 Step 1 Select the desired day of the week. → The time table of the selected day of the week will be displayed. Step 2 Configure each setting item. There are 2 setup pages. To move to another page, select the [k] or [l] button. [Copy the other program] To copy a time table set for another day of the week, select the day of the week to be copied, and select the [Copy] but- ton. ■ New time table setup Configure the settings of the following item for each time zone. [Start] Set the start time of the time zone. [End] Set the end time of the time zone. Note: • The time can be set in 1-minute increments. However, the end time should be at least 15 minutes later than the start time. • It is impossible to set "23:46" or later for the start time. • Set "Start" and "End" in the 24-hour time display format. [Program] Select the desired program (PROG1 to 4). [Event] Select "On" or "Off" to determine whether or not to perform event actions at an event occurrence. [Alarm message] Select "On" or "Off" to determine whether or not to display the pop-up window that notify of an event occurrence with a message on the screen of the PC. [FTP image transmission by alarm] Select "On" or "Off" to determine whether or not to transmit the alarm image to the FTP server according to the settings of "Image transmission by alarm" (+ page 96) on the "Server" page - the [FTP] tab. Assign a program after setting the time zone [Time table] Select the [Time table] tab on the "Schedule" page. (+ Page 60) A time table for program actions can be created for each day of the week, and programs can be assigned to each time table. Up to 6 time tables can be created for each day of the week. When a signal is supplied from the ALARM/CONTROL connector (external recording changeover, pin no. 24), the recorder will work with the set timetable for "Ext." regardless of the days of the week. At the default, 0:00 to 24:00, PROG1 has been set for "Daily".
82 [Panasonic alarm protocol] Select "On" or "Off" to determine whether or not to automati- cally notify the PC of the event information by Panasonic alarm protocol at an event occurrence. [Mail] Select "On" or "Off" to determine whether or not to transmit the alarm mail according to the settings of the "Server" page - the [Mail] tab (+ page 97) at an event occurrence. [Back] button Closes the time table of the selected day of the week and returns to the [Time table] tab. Set the following items for desired special days [Date] Enter the desired date to be set as a special day. [Mode] Select the day of the week to which the desired schedule is assigned. Note: • Only the days of the week to which programs have been assigned on the [Time table] tab will be displayed. It is impossible to select this item when there are no available days of the week. Configure the settings of recording programs for special days [Special days] Select the [Special days] tab on the "Schedule" page. (+ Page 60) It is possible to assign timetables to special days aside from other days of the week. Time tables for special days can be set for up to 30 days. The settings are configured by specifying dates as special days and by applying a schedule to the\ specified special days.
83 Configure the settings relating to display [Display] The settings relating to the display on Monitor 1 and Monitor 2 connected to the recorder and the display on a PC monitor con- nected to the recorder via a network can be configured on the "Display" page. The settings relating to display switching patterns such as multi screen display and sequential display of live images can also be configured on this page. The "Display" page has [Common], [Monitor 1], [Monitor 2], [Camera title\ ], [Network] and [Cascade] tabs. Common settings for monitors [Common] Select the [Common] tab on the "Display" page. (+ Page 60) The common display settings for Monitor 1 and Monitor 2 such as the sett\ ings of camera titles or the settings of the time display position can be configured on this tab. The settings relating to the multi screen display can also be configured on this tab. [Time & date display position] Select the position to display the time & date. When setting the time & date to be recorded together with images, the time display will be recorded in the selected position. Refer to "Embedded Rec (Time & date)" (+ page 68) of the "Basic" page - the "Recording" tab for how to record the time & date together with the images. L-Upper: Displays the time & date on the upper left cor- ner on the screen. R-Upper: Displays the time & date on the upper right corner on the screen. L-Lower: Displays the time & date on the lower left cor- ner on the screen. R-Lower: Displays the time & date on the lower right corner on the screen. Default: L-Upper Note: • Determine whether or not to display the time & date on Monitor 1 on the [Monitor 1] tab. (+ Page 86) [Camera title display position] Select the position to display the camera title. When the settings are configured to record images together with a camera title, the camera title position will be deter- mined on this setting. Refer to "Embedded Rec (Title)" (+ page 67) of the "Basic" page - the "Recording" tab for how to record the camera title together with the images. L-Upper: Displays the camera title on the upper left cor- ner on the screen. R-Upper: Displays the camera title on the upper right corner on the screen. L-Lower: Displays the camera title on the lower left cor- ner on the screen. R-Lower: Displays the camera title on the lower right corner on the screen. Default: R-Upper: Note: • Determine whether or not to display the camera title on Monitor 1 on the [Monitor 1] or [Monitor 2] tab. (+ Pages 86 and 88) [Line color on the multi screen] Select a parting line color from the following. White: Displays white parting lines. Gray: Displays grey parting lines. Black: Displays black parting lines. Default: White [Multi screen setup] Configures the multi screen display pattern and assigns camera channels to each multi screen segment. Select the [Setup] button to configure the settings. (+ Page 84)
84 Configure the multi screen display pattern and assign camera channels to each multi screen segment Select the display pattern when switching to the multi screen display. In addition, assign the camera channels to each multi screen segment. When selecting the [Setup] button of "Multi screen setup" on the [Common] tab, the setup page for camera channel alloca\ tion will be displayed. To configure the settings, do the following. Step 1 Check the desired multi screen display pattern of the param- eters of "Use". The desired display pattern can be selected while moving to the previous or next page by selecting "Prev page or Next page". To return to the [Common] tab, select the [Back] but- ton. 4Screen-A: Displays images from camera channels 1 - 4 on a 4-split screen. 4Screen-B: Displays images from camera channels 5 - 8 on a 4-split screen. 4Screen-C: Displays images from camera channels 9 - 12 on a 4-split screen. 4Screen-D: Displays images from camera channels 13 - 16 on a 4-split screen. 4Screen (WD): Displays images from camera channels on a 4-split screen. Images from any camera chan- nels can be selected. 7Screen (WD): Displays images from camera channels on a 7-split screen. Images from any camera chan- nels can be selected. 8Screen: Displays images from camera channels on a 8-split screen. Images from any camera channels can be selected. 9Screen-A: Displays images from camera channels 1 - 9 on a 9-split screen. 9Screen-B: Displays images from camera channels 10 - 16 on a 9-split screen. 9Screen (WD): Displays images from camera channels on a 9-split screen. Images from any camera chan- nels can be selected. 12Screen (WD)-A: Displays images from camera chan- nels 1 - 12 on a 12-split screen. 12Screen (WD)-B: Displays images from camera chan- nels 13 - 16 on a 12-split screen. 16Screen: Displays images from camera channels 1 - 16 on a 16-split screen.
85 Step 2 Select the desired camera channels to display on the multi screen. Select the [Setup] button of "Camera setup". → The setup page for camera channel allocation will be displayed. Note: • The [Setup] button is displayed on "Camera setup" for multi screen display patterns for which any camera channels can be selected. The [Setup] button is not dis- played for multi screen display patterns for which any camera channels cannot be selected. Step 3 Select the desired camera channels to display on each seg- ment on the multi screen. To return to the [Common] tab, select the [Back] button. Note: • It is impossible to select the same channel to display images from it on multiple segments on the multi screen. • When configuring from a PC (web browser), images from cameras will not be displayed.
86 Configure the display settings for Monitor 1 [Monitor 1] Select the [Monitor 1] tab on the "Display" page. (+ Page 60) Select "On" or "Off" to determine whether or not to display the time, camera title and ala\ rm display on Monitor 1. The settings relating to the sequence display on Monitor 1 can also be configured on this tab. [Time & date display] Select "On" or "Off" to determine whether to enable or dis- able the time display. [Camera title display] Select "On" or "Off" to determine whether to enable or dis- able the camera title display. [Alarm display] Select "On" or "Off" to determine whether to enable or dis- able the alarm display. [Login screen] Select a camera image to be displayed during the login pro- cedure. --: No camera image will be displayed. (Black screen) Cam. 1 to Cam. 16: Displays an image from the select-ed camera channel on a single screen. 4Screen-A/4Screen-B/4Screen-C/4Screen-D/ 4Screen(WD)/7Screen(WD)/8Screen/9Screen-A/ 9Screen-B/9Screen(WD)/12Screen(WD)-A/ 12Screen(WD)-B/16Screen/SEQ Refer to page 84 for further information about each multi screen display pattern, and refer to page 87 for further information about the sequential display. Default: -- [Secret view] The secret view is a function that skips camera images dis- played with a single screen display on Monitor 2 when dis- playing with the sequential display on Monitor 1. Select "On" or "Off" to determine whether to enable or disable the secret view function. On: Enables the secret view function. (Camera images displayed with a single screen display on Monitor 2 is displayed as a black screen. ) However, when recorded images are displayed on Monitor 2, the black screen is not displayed. Off: Disables the secret view function. [Live sequence] Configure the sequential display settings of camera images. Select the [Setup] button to configure the settings. (+ Page 87) [Sequence timing] Determine how to switch camera images. Int: Switches images according to the settings of the "Dwell time" of "Live Sequence". Ext: Switches images by signals from an external device. Mon2: Switches images according to the sequence tim- ing of Monitor 2. Note: • "Ext" is selected when an external device is connected to output the sequence signals • Pin No. 21 (Sequence Switching) of the ALARM/ CONTROL connector on the rear panel of the recorder works as an input terminal when "Int" is set for "Sequence timing", and works as an output terminal when "Ext" is set. (+ Page 44)
87 Configuring the sequence display settings Configure the sequential display settings of camera images. When selecting the [Setup] button of "Live sequence" on the [Monitor 1] \ tab, the setup page for live sequence will be displayed. (+ Page 86) Configure the following setting items for each step of sequential display. Up to 16 steps can be registered. [Cam.] Select a camera image to be displayed at each step from the following. Cam. 1 to Cam. 16: Displays an image from the select-ed camera channel on a single screen. 4Screen-A/4Screen-B/4Screen-C/4Screen-D/ 4Screen(WD)/7Screen(WD)/8Screen/9Screen-A/ 9Screen-B/9Screen(WD)/12Screen(WD)-A/ 12Screen(WD)-B/16Screen Refer to page 84 for further information about each set- ting value. [Preset position] Select a camera preset position (---, 1 to 256). When "---" is selected, the camera does not move to any preset position. [Dwell time] Select an interval time to go to the next sequential step. 2s/3s/5s/10s/20s [Back] button Closes the setup page for live sequence and returns to the [Monitor 1] tab.
88 Configure the display settings for Monitor 2 [Monitor 2] Select the [Monitor 2] tab on the "Display" page. (+ Page 60) Set the position to display the status bar and select "On" or "Off" to determine whether or not to display the camera title. The settings relating to the sequence display on Monitor 2 can also be configured on this tab. [Status display] Select the position to display the status bar. Upper: Displays the status bar on the top of the screen. Low: Displays the status bar on the bottom of the screen. Default: Low: [Camera title display] Select "On" or "Off" to determine whether to enable or dis- able the camera title display. [Login screen] Select a camera image to be displayed during the login pro- cedure. Available setting values are the same as Monitor 1. Refer to page 86. [Live sequence] Configure the sequential display settings of camera images. The setup procedure is the same as Monitor 1. Refer to page 86. [Sequence timing] Determine how to switch camera images. Int: Switches images according to the settings of the "Dwell time" of "Live sequence". Ext: Switches images by signals from an external device. Note: • "Ext" is selected when an external device is connected to output the sequence signals • Pin No. 21 (Sequence Switching) of the ALARM/ CONTROL connector on the rear panel of the recorder works as an input terminal when "Int" is set for "Sequence timing", and works as an output terminal when "Ext" is set. Configuring the sequence display settings Configure the sequential display settings of camera images. When selecting the [Setup] button of "Live Sequence" on the [Monitor 2] \ tab, the setup page for live sequence will be displayed. The setup procedure is the same as Monitor 1. Refer to page 87.
89 Configure the camera title [Camera title] Select the [Camera title] tab on the "Display" page. (+ Page 60) The camera title can be configured on this tab. [Display] Enter a camera title to be displayed on Monitor 2. Enter up to 14 alphanumeric characters for the camera title. Note: • Available characters: !"#$%&'( )*+,-./:;?@[\]^_`{|}~ (space) [Embedded Rec] Enter the camera title to be recorded together with the imag- es. The setting is also applied to the camera title to be displayed on Monitor 1. Enter up to 14 alphanumeric characters for the camera title. Important: • To record the camera title together with the images, it is necessary to select "On" for "Embedded Rec (Title)" (+ page 68) of the "Basic" page - the "Recording" tab. Note: • Available characters: "#&( )*+,-./:;? (space)
90 Configure the settings relating to the sequential display on a PC monitor [Network] Select the [Network] tab on the "Display" page. (+ Page 60) The settings for the sequential display when displaying images on a moni\ tor of a PC connected to this recorder via a network can be configured on this tab. [The method of sequence] Select the desired sequential display pattern from the follow- ing. 1-screen: Displays images with the sequential display on a 1-split screen. 4-screen: Displays images with the sequential display on a 4-split screen. Default: 1-screen [1-screen live sequence] Configure the settings for the sequential display when dis- playing images with the sequential display on a 1-split screen. When the [Setup] button is selected, the following setup page will be displayed to configure each setting item. • [Cam.] Select a camera image (---, Cam.1 - Cam.16) to be dis- played at each step. When "---" is selected, the step will be skipped. • [Preset position] Select a camera preset position (---, 1 to 256). When "---" is selected, the camera does not move to any pre- set position. • [Dwell time] Select an interval time to go to the next sequential step. 2s/3s/5s/10s/20s • [Back] button Closes the setup page for 1-screen live sequence and returns to the [Network] tab.