    Have a look at the manual Panasonic Digital Disk Recorder Wj Hd616 Wj Hd716 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							91
    [4-screen	live	sequence]
    Configure the settings for the sequential display when dis-
    playing images with the sequential display on a 4-split 
    screen. 
    When the [Setup] button is selected, the following setup 
    page will be displayed to configure each setting item. 
    	 •	 [Cam.]
       Select a camera image to be displayed at each step 
    from the following. 
        --: Skips the selected step. 
    Quad1 - 4: Displays images from camera channels 1 - 4  on a 4-split screen. 
    Quad5 - 8: Displays images from camera channels 5 - 8  on a 4-split screen. 
    Quad9 - 12: Displays images from camera channels 9 -  12 on a 4-split screen. 
    Quad13 - 16: Displays images from camera channels  13 - 16 on a 4-split screen. 
    	 •	 [Dwell	time]
        Select an interval time to go to the next sequential step. 
        2s/3s/5s/10s/20s
    	 •	 [Back]	button
        Closes the setup page for 4-screen live sequence and 
    returns to the [Network] tab. 
    Note:
    	 •	 Depending	on	the	network	traffic,	the	sequential	display	 may not work exactly with the set interval time for [Dwell 
    time]. 
     
        
    Configure	the	settings	relating	to	the	cascade	connection	[Cascade]
    Select the [Cascade] tab on the "Display" page. (+ Page 60)
    The settings relating to the cascade connection to use two or more recorders can be configured on this tab. 
        
    [Cascade]
    Select "On" or "Off" to determine whether to enable or dis-
    able the cascade connection to use two or more recorders. 
    Select "On" when using two or more recorders for the cas-
    cade connection.
        
    Note:
        When "On" is selected for "Cascade", the time of the 
    recorders whose "Unit address (system)" (+  page 93) is 
    set to "002" to "004" are periodically adjusted to that of 
    the recorder whose "Unit address (system)" is set to 
    "001". (Cascade time adjustment)
        However, when "On" is set for "Time adjustment"  
    (+ page 95), the time will be adjusted according to the 
    NTP server.
    [Cascade	sequence]
    Select "On" or "Off" to determine whether or not to perform 
    the sequential display when the recorders are connected in 
    the cascade connection. 
    It is possible to perform the sequential display in the order of 
    cascade connection of the recorders.  
    						
    							92
    Configure the settings relating to communication with other devices 
    [Communication]
    It is necessary to apply the same settings such as the communication spe\
    ed and the communication protocol to the recorder 
    and the external devices such as a controller connected to the DATA port on the rear panel of the recorder 
    The settings relating to the communication method to control cameras and to communicate with external devices can be config-
    ured on the "Communication" page. 
    The "Communication" page has [Camera control], [PS
    ·Data setup] and [RS485 setup] tabs.
    Configure the communication settings for camera control [Camera con-
    trol]
    Select the [Camera control] tab on the "Communication" page. (+ Page 60)
    The communication settings for each camera channel to control cameras can be configured on this tab. 
        
    [Comp]
    It is possible to compensate for the video signal transmission 
    loss from the camera. For HD616K, the setting is available 
    for Camera 1 to 8. For HD716K, the setting is available for 
    Camera 1 to 16. Select the setting value in accordance with 
    the cable length. For HD616K, the setting is available for 
    Camera 1 to 8. For HD716K, the setting is available for 
    Camera 1 to 16.S: When the length of cable used is shorter than 500 m {2 953 ft}
    M: When the length of cable used is longer than 500 m  {1 640 ft} and shorter than 900 m {2 953 ft}
    L: When the length of cable used is longer than 900 m  {2 953 ft} and shorter than 1 200 m {3 937 ft}
    Default: S
    [Type]
    Configure the communication settings for each camera 
    channel to control cameras.  COAX: Controls cameras with coaxial communication. For HD616K, the setting is available for Camera 1 to 
    8. For HD716K, the setting is available for Camera 1 
    to 16.
    PSD: Controls cameras with PS·Data communication. 
    RS485: Controls cameras with RS485 communication. 
    Off: Not controls cameras. 
    Default:   Camera 1 to 18: COAX, Camera 9 to 16: PS·Data 
    (COAX for HD716K) :
        
    Note:
    	 •	 Configure	the	settings	in	accordance	with	cameras	con- nected to the reorder. 
    	 •	 To	control	cameras	with	the	coaxial	cable,	connect	cam- eras to the video input connectors 1 to 8 (compatible 
    with coaxial cable communication). Use a Panasonic 
    data multiplex unit to control cameras connected to 
    other camera channels with coaxial cables. In this case, 
    select "PSD" for the communication method of the cam-
    era to be controlled via the data multiplex unit.
    	 •	 For	HD716K,	it	is	possible	to	control	cameras	connected	 to the video input connectors 1 to 16 with the coaxial 
    communication. 
    	 •	 Set	the	unused	camera	channels	to	"Off".	
     
         
    						
    							93
    [Unit	address	(system)]
    A unit address is a unique number to be assigned to each 
    PS·Data compatible device. Each address of the system 
    devices must be unique to identify them when connecting 
    two or more PS·Data compatible devices.
    For example, numbers "001" - "099" are assigned to unit 
    addresses for system devices.
    [Unit	address	(controller)]
    The unit address (controller) is used to control a PS·Data 
    device connected to this unit. Assign a number from "001" - 
    "099" for a unit address.
    [Baud	rate]
    Select a communication speed for data transmission with a 
    connected device from the following:
       2 400/4 800/9 600/19 200/38 400 (bps)
    Default: 9 600
    [Data	bit]
    The data length for communication will be displayed. 
    It is impossible to change the setting value. 
    [Parity]
    Methods of error check for a transmission at communication 
    will be displayed. 
    It is impossible to change the setting value. 
    [Stop	bit]
    Stop bit types will be displayed. 
    It is impossible to change the setting value. 
    [Retry	timing]
    When data reception is not confirmed, the interval to retrans-
    mit the same data is displayed. 
    It is impossible to change the setting value. 
         [Alarm	data]
    The method to notify the connected controller of an event 
    occurrence is displayed. 
    It is impossible to change the setting value. 
    [Camera	number	setup]
    Configure the settings for each camera channel to control 
    cameras using the PS·Data compatible controller. 
    When the [Setup] button is selected, the following page will 
    be displayed. 
    	 •	 [No.]
       
    Select the desired camera number (1 to 999) for each 
    camera channel. 
    	 •	 [Back]	button
        Closes the setup page and returns to the [PS.Data 
    Setup] tab. 
        
    Configure	the	settings	relating	to	PS·Data	[PS·Data	setup]
    Select the [PS·Data setup] tab on the "Communication" page. (+ Page 60)
    The settings for PS·Data can be configured on this tab. 
         
    						
    							94
    Configure	the	settings	relating	to	RS485	[RS485	setup]
    Select the [RS485 setup] tab on the "Communication" page. (+ Page 60)
    The settings for RS485 can be configured on this tab. 
        
    [Protocol]
    Select the protocol used for RS485 communication. 
       Panasonic/Pelco-D
    Default: Panasonic
    [Baud	rate]
    Select a communication speed for data transmission with a 
    connected device from the following:
        2 400/4 800/9 600/19 200/38 400 (bps)
    Default: 19 200
    [Control	camera	ch]
    Allocate the RS485 port 1 and port 2 to camera channels. 
    When the [Setup] button is selected, the following page will 
    be displayed. 
    	 •	 [TERM]
        Select a port to be controlled from the following for each 
    camera channel. 
        PORT1: Controls from the RS485 port 1. 
        PORT2: Controls from the RS485 port 2. 
    	 •	 [Back]	button
        Closes the setup page and returns to the [RS485 setup] 
    tab. 
         [Data	bit]
    The data length for communication will be displayed. 
       
    7/8 (bit)
    Default: 8
    [Parity]
    Methods of error check for a transmission at communication 
    will be displayed.  NONE: No parity check
    EVEN: Even parity
    ODD: Odd parity
    Default: NONE
    [Stop	bit]
    Stop bit types will be displayed. 
        1/2 (bit)
    Default: 1 
    						
    							95
    Configure	the	settings	relating	to	the	server	[Server]
    The settings relating to the NTP server, the FTP server and the mail server can be configured on the "Server" page. 
    The "Server" page has [NTP], [FTP] and [Mail] tabs. 
    Configure	the 	settings 	relating 	to 	time 	adjustment 	according 	to 	the 	NTP	
    server	[NTP]
    Select the [NTP] tab on the "Server" page. (+ Page 60)
    The settings when time is adjusted according to the NTP (Network Time Protocol) server can be configured on this tab. 
        
    [Time	adjustment]
    Select "On" or "Off" to determine whether or not to adjust 
    the time according to the NTP server. 
    [NTP	server	address]
    Enter the NTP server address when adjusting the time using 
    the NTP server.
    The name of the NTP server is available only when selecting 
    "Manual" or "Auto" for the "Network" page - the [DNS] tab. 
    Enter up to 255 alphanumeric characters including hyphens 
    (-) and periods (.). 
    Important:
    	 •	 When	"On"	is	selected	for	the	DHCP	setting	of	the	 recorder, the setting for "Time adjustment" will not be 
    activated in case the time of recorder is ±1 000 seconds 
    or more different from that of the NTP server. 
     
         
    						
    							96
    Configure	the	settings	relating	to	the	FTP	server	[FTP]
    Select the [FTP] tab on the "Server" page. (+ Page 60)
    The basic settings such as the FTP server address, user name and password and the setting to transmit alarm images at an 
    event occurrence can be configured on this tab. 
        
    [FTP	server	address]
    Enter an address or name of the FTP server to transmit 
    images. 
    The name of the FTP server is available only when selecting 
    "Manual" or "Auto" for the "Network" page - the [DNS] tab. 
    Enter up to 255 alphanumeric characters including hyphens 
    (-) and periods (.). 
    [User	name]
    Enter a user name (login name) to access the FTP server. 
    Enter up to 32 alphanumeric characters excluding (&) listed 
    as follows. Note:
    	 •	 Available	characters:
        A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a 
    b c d e f g h i j k l m n o p q r s t u v w x y z 0 1 2 3 4 5 6 
    7 8 9 ! " # $ % ' ( ) * + , - . / :; < = > ? @ [  ] ^ _ ` { | } ~
     
    [Password]
    Register a password to be entered when transmitting imag-
    es to the FTP server. Enter up to 32 alphanumeric characters 
    excluding "&" listed in the description of "Available charac-
    ters". An entered character for the password will be dis-
    played as "∗" or "·". 
    [Mode]
    Select the mode to transmit images to the FTP server. 
    Change to "Passive" when sending images is difficult with 
    "Active". Change to "Passive" when sending images is diffi-
    cult with "Sequencial".
        ■  Image transmission by alarm
    [Server	directory]
    Enter a directory of the server. Enter up to 128 alphanumeric 
    characters (excluding "& *: < > ?  ~") listed in the description 
    of "Available characters". Enter up to 255 alphanumeric 
    characters excluding "& * : < > ?  | ~ " listed in the descrip-
    tion of "Available characters". 
    [Duration-pre]
    Select the duration of the images recorded by pre-event 
    recording to be transmitted from the following. 
        Off/1 s - 10 s (in 1 second intervals)
    Default: Off
    Important:
    	 •	 The	setting	for	"Duration-pre"	is	the	shortest	duration	to	 transmit images recorded by pre-event recording. The 
    actual duration of the recorded images to be transmitted 
    will be longer than the setting.
    	 •	 Images	recorded	by	pre-event	recording	will	not	be	 transmitted when pre-event recording is not to be per-
    formed. Configure the setting to perform pre-event 
    recording to transmit images recorded by pre-event 
    recording. Refer to page 80 for further information on 
    how to configure the settings relating to the pre-event 
    recording.
     
    [Duration-post]
    Select the duration of the transmitted images for the post-
    event recording.
        Off/1 s - 10 s (in 1 second intervals)
    Default: 5 s
    [Alteration	detection]
    Select "On" or "Off" to determine whether or not to attach an 
    alteration detection code to recorded images to be transmit-
    ted using the viewer software when an alarm occurs. 
         
    						
    							97
    Configure	the	settings	relating	to	the	mail	notification	[Mail]
    Select the [Mail] tab on the "Server" page. (+ Page 60)
    The settings of alarm mail notice, the settings of error report mail (+ Operating Instructions (PDF)) and the settings to use the mail 
    functions can be configured on this tab. 
        
    [SMTP	server	address]
    Enter an IP address or a name of the SMTP server to send 
    e-mails. The name of the SMTP server is available only when 
    selecting "Manual" or "Auto" for the "Network" page - the 
    [DNS] tab. Enter up to 255 alphanumeric characters includ-
    ing hyphens (-) and periods (.). The name of the SMTP server 
    is available only when selecting "Manual" or "Auto" for the 
    "Network" page - the [DNS] tab. Enter up to 255 alphanu-
    meric characters including hyphens (-) and periods (.). 
    [SMTP	port	number]
    Enter the port number of the SMTP server. 
       1 - 65535
    Default: 25
    [POP	server	address]
    Enter an IP address or name of the POP server to be used 
    for POP before SMTP authentication.
    The name of the POP server is available only when selecting 
    "Manual" or "Auto" for the "Network" page - the [DNS] tab.
    Enter up to 255 alphanumeric characters including hyphens 
    (-) and periods (.).
    [Type]
    Select the authentication method to send e-mails from the 
    following. 
        None /POP before SMTP/SMTP
    Default: None
    [Type	-	User	name]
    Enter the user name to be required for the authentication. 
    Enter up to 32 alphanumeric characters excluding "&" listed 
    in the description of "Available characters". (+ Page 96) 
         [Type	-	Password]
    Enter the password to be required together with the user 
    name for the authentication. Enter up to 32 alphanumeric 
    characters excluding "&" listed in the description of 
    "Available characters". An entered character for the pass-
    word will be displayed as "∗" or "·". Enter up to 32 alphanu-
    meric characters excluding "&" listed in the description of 
    "Available characters" (+ page 96). An entered character for 
    the password will be displayed as "∗" or "·". 
    [Sender's	address]
    Enter the mail address of a sender. Entered mail addresses 
    will be displayed in the "From" (sender) line. Enter up to 255 
    alphanumeric characters including hyphens (-), periods (.), 
    underscore marks (_) and @. Entered address will be dis-
    played in the sender's line ("From" field) of the received mail. 
    Enter up to 127 alphanumeric characters including hyphens 
    (-), periods (.), underscore marks (_) and @. 
    ■
     Destination address
    [Address	1]
    Enter the mail addresses of the recipients of the alarm mail 
    (+ Operating Instructions (PDF)) and the warning mail (+ 
    Operating Instructions (PDF)). Enter up to 255 alphanumeric 
    characters including hyphens (-), periods (.), underscore 
    marks (_) and @. 
    Check the desired mail type (warning/alarm) to be sent. 
    Up to 4 destinations can be registered. To add destinations, 
    select the [Setup] of "Other destinations". 
         
    						
    							98
    [Other	destinations]
    Add other destinations. When the [Setup] button is selected, 
    the following page will be displayed. When the [Setup] but-
    ton is selected, the following page will be displayed. 
    Enter the desired mail address and mail type for "Address 1" 
    - "Address 4". 
    The setup procedure is the same as [Address 1]
    When the [Back] button is selected, the setup page will be 
    closed, and the display will return to the [Mail] tab.  
    						
    							99
    Configure	the	settings	relating	to	network	[Network]
    The basic network settings required to operate this unit using a PC via a network such as a LAN can be co\
    nfigured on the 
    "Network" page. The settings relating to the Panasonic alarm protocol and the settings relating to the resolution and rate to 
    transmit live images can also be configured on this page. 
    The "Network" page has [Basic], [DNS], [DDNS], [SNMP], [Panasonic alarm \
    protocol] and [Transmission] tabs. 
    Configure	the	basic	settings	relating	to	a	network	[Basic]
    Select the [Basic] tab on the "Network" page. (+ Page 60)
    The basic settings relating to a network can be configured on this tab. 
        
    [HTTP	port	number]
    Specify the HTTP port number to be used to send images 
    from the unit. 
    It is unnecessary to change it for normal use. 
       1 - 65535
    Default: 80
    Note:
    	 •	 Depending	on	the	network	settings,	network	communi- cation may not be established if the http port number 
    has been changed. In this case, refer to the administra-
    tor of each network. In this case, refer to the administra-
    tor of the network.
    	 •	 The	following	numbers	and	the	FTP	port	number	are	 unavailable for the HTTP port number. 
        20, 21, 23, 25, 42, 53, 67, 68, 69, 79, 105, 110, 123, 
    161, 162, 546, 547, 995, 10001, 10002, 10003, 10004, 
    10005, 10006, 10007
     
    [FTP	port	number]
    Designate the FTP port number of the recorder. 
    It is unnecessary to change it for normal use. 
        1 - 65535
    Default: 21
        Note:
    	 •	 The	following	numbers	and	the	HTTP	port	number	are	 unavailable for the FTP port number. 
        20, 23, 25, 42, 53, 67, 68, 69, 79, 80, 105, 110, 123, 
    161, 162, 546, 547, 995, 10001, 10002, 10003, 10004, 
    10005, 10006, 10007
     
    ■  Network Port
    The setting for the network port on the rear panel of the 
    recorder is configured. 
    This setting is required to operate the recorder from a PC 
    connected via a network using the network ports. 
    [DHCP]
    Select "On" or "Off" to determine whether or not to use the 
    DHCP server. 
    Select "On" to obtain an IP address, a subnet mask and a 
    gateway address from the DHCP server. 
    Set to "Off" when entering the addresses above manually. 
    The IP address, subnet mask and default gateway obtained 
    from the DHCP server are displayed on each setting area. 
    Default: Off
    Note:
    	 •	 When	the	setting	of	DHCP	is	changed	from	"On"	to	 "Off", the setting of DNS will be automatically changed 
    to "Off".
         
    						
    							100
    [IP	address]
    When "Off" is selected for "DHCP", enter an IP address. 
    Enter 4 units from the decimal numbers (0-255). 
    Default: 192.168.0.250
    [Subnet	mask]
    Enter a subnet mask according to the network environment 
    when "Off" is selected for "DHCP". Enter 4 units from the 
    decimal numbers (0-255). 
    Default: 255.255.255.0
    [Default	gateway]
    Enter the IP address of the gateway according to the net-
    work environment when "Off" is selected for "DHCP". Enter 
    4 units from the decimal numbers (0-255). 
    Default: 192.168.0.1
    [Line	speed]
    Specify the line speed for data transmission. Auto: Line speed will be applied automatically. 
    10M-Half: 10 Mbps half-duplex
    10M-Full: 10 Mbps full-duplex
    100M-Half: 100 Mbps half-duplex
    100M-Full: 100 Mbps full-duplex
    Default: Auto
    ■ 	Maintenance	port
    The setting for the maintenance port behind the front cover 
    of the recorder is configured. 
    This setting is required to maintain and support the recorder 
    from a PC connected via a network using the maintenance 
    port. 
    [IP	address]
    When "Off" is selected for "DHCP", enter an IP address. 
    Enter 4 units from the decimal numbers (0-255).
    Default: 192.168.2.250
    [Subnet	mask]
    Enter a subnet mask according to the network environment 
    when "Off" is selected for "DHCP". Enter 4 units from the 
    decimal numbers (0-255). 
    Default: 255.255.255.0
    Important:
    	 •	 The	settings	of	"Network	Port"	and	"Maintenance	Port"	 should be on a different subnet.
    [Line	speed]
    Displays the line speed for data transmission. 
    It is impossible to change the setting value. 
         
    						