Home
>
Panasonic
>
Recording Equipment
>
Panasonic Digital Disk Recorder Wj Hd616 Wj Hd716 Installation Guide
Panasonic Digital Disk Recorder Wj Hd616 Wj Hd716 Installation Guide
Have a look at the manual Panasonic Digital Disk Recorder Wj Hd616 Wj Hd716 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
91 [4-screen live sequence] Configure the settings for the sequential display when dis- playing images with the sequential display on a 4-split screen. When the [Setup] button is selected, the following setup page will be displayed to configure each setting item. • [Cam.] Select a camera image to be displayed at each step from the following. --: Skips the selected step. Quad1 - 4: Displays images from camera channels 1 - 4 on a 4-split screen. Quad5 - 8: Displays images from camera channels 5 - 8 on a 4-split screen. Quad9 - 12: Displays images from camera channels 9 - 12 on a 4-split screen. Quad13 - 16: Displays images from camera channels 13 - 16 on a 4-split screen. • [Dwell time] Select an interval time to go to the next sequential step. 2s/3s/5s/10s/20s • [Back] button Closes the setup page for 4-screen live sequence and returns to the [Network] tab. Note: • Depending on the network traffic, the sequential display may not work exactly with the set interval time for [Dwell time]. Configure the settings relating to the cascade connection [Cascade] Select the [Cascade] tab on the "Display" page. (+ Page 60) The settings relating to the cascade connection to use two or more recorders can be configured on this tab. [Cascade] Select "On" or "Off" to determine whether to enable or dis- able the cascade connection to use two or more recorders. Select "On" when using two or more recorders for the cas- cade connection. Note: When "On" is selected for "Cascade", the time of the recorders whose "Unit address (system)" (+ page 93) is set to "002" to "004" are periodically adjusted to that of the recorder whose "Unit address (system)" is set to "001". (Cascade time adjustment) However, when "On" is set for "Time adjustment" (+ page 95), the time will be adjusted according to the NTP server. [Cascade sequence] Select "On" or "Off" to determine whether or not to perform the sequential display when the recorders are connected in the cascade connection. It is possible to perform the sequential display in the order of cascade connection of the recorders.
92 Configure the settings relating to communication with other devices [Communication] It is necessary to apply the same settings such as the communication spe\ ed and the communication protocol to the recorder and the external devices such as a controller connected to the DATA port on the rear panel of the recorder The settings relating to the communication method to control cameras and to communicate with external devices can be config- ured on the "Communication" page. The "Communication" page has [Camera control], [PS ·Data setup] and [RS485 setup] tabs. Configure the communication settings for camera control [Camera con- trol] Select the [Camera control] tab on the "Communication" page. (+ Page 60) The communication settings for each camera channel to control cameras can be configured on this tab. [Comp] It is possible to compensate for the video signal transmission loss from the camera. For HD616K, the setting is available for Camera 1 to 8. For HD716K, the setting is available for Camera 1 to 16. Select the setting value in accordance with the cable length. For HD616K, the setting is available for Camera 1 to 8. For HD716K, the setting is available for Camera 1 to 16.S: When the length of cable used is shorter than 500 m {2 953 ft} M: When the length of cable used is longer than 500 m {1 640 ft} and shorter than 900 m {2 953 ft} L: When the length of cable used is longer than 900 m {2 953 ft} and shorter than 1 200 m {3 937 ft} Default: S [Type] Configure the communication settings for each camera channel to control cameras. COAX: Controls cameras with coaxial communication. For HD616K, the setting is available for Camera 1 to 8. For HD716K, the setting is available for Camera 1 to 16. PSD: Controls cameras with PS·Data communication. RS485: Controls cameras with RS485 communication. Off: Not controls cameras. Default: Camera 1 to 18: COAX, Camera 9 to 16: PS·Data (COAX for HD716K) : Note: • Configure the settings in accordance with cameras con- nected to the reorder. • To control cameras with the coaxial cable, connect cam- eras to the video input connectors 1 to 8 (compatible with coaxial cable communication). Use a Panasonic data multiplex unit to control cameras connected to other camera channels with coaxial cables. In this case, select "PSD" for the communication method of the cam- era to be controlled via the data multiplex unit. • For HD716K, it is possible to control cameras connected to the video input connectors 1 to 16 with the coaxial communication. • Set the unused camera channels to "Off".
93 [Unit address (system)] A unit address is a unique number to be assigned to each PS·Data compatible device. Each address of the system devices must be unique to identify them when connecting two or more PS·Data compatible devices. For example, numbers "001" - "099" are assigned to unit addresses for system devices. [Unit address (controller)] The unit address (controller) is used to control a PS·Data device connected to this unit. Assign a number from "001" - "099" for a unit address. [Baud rate] Select a communication speed for data transmission with a connected device from the following: 2 400/4 800/9 600/19 200/38 400 (bps) Default: 9 600 [Data bit] The data length for communication will be displayed. It is impossible to change the setting value. [Parity] Methods of error check for a transmission at communication will be displayed. It is impossible to change the setting value. [Stop bit] Stop bit types will be displayed. It is impossible to change the setting value. [Retry timing] When data reception is not confirmed, the interval to retrans- mit the same data is displayed. It is impossible to change the setting value. [Alarm data] The method to notify the connected controller of an event occurrence is displayed. It is impossible to change the setting value. [Camera number setup] Configure the settings for each camera channel to control cameras using the PS·Data compatible controller. When the [Setup] button is selected, the following page will be displayed. • [No.] Select the desired camera number (1 to 999) for each camera channel. • [Back] button Closes the setup page and returns to the [PS.Data Setup] tab. Configure the settings relating to PS·Data [PS·Data setup] Select the [PS·Data setup] tab on the "Communication" page. (+ Page 60) The settings for PS·Data can be configured on this tab.
94 Configure the settings relating to RS485 [RS485 setup] Select the [RS485 setup] tab on the "Communication" page. (+ Page 60) The settings for RS485 can be configured on this tab. [Protocol] Select the protocol used for RS485 communication. Panasonic/Pelco-D Default: Panasonic [Baud rate] Select a communication speed for data transmission with a connected device from the following: 2 400/4 800/9 600/19 200/38 400 (bps) Default: 19 200 [Control camera ch] Allocate the RS485 port 1 and port 2 to camera channels. When the [Setup] button is selected, the following page will be displayed. • [TERM] Select a port to be controlled from the following for each camera channel. PORT1: Controls from the RS485 port 1. PORT2: Controls from the RS485 port 2. • [Back] button Closes the setup page and returns to the [RS485 setup] tab. [Data bit] The data length for communication will be displayed. 7/8 (bit) Default: 8 [Parity] Methods of error check for a transmission at communication will be displayed. NONE: No parity check EVEN: Even parity ODD: Odd parity Default: NONE [Stop bit] Stop bit types will be displayed. 1/2 (bit) Default: 1
95 Configure the settings relating to the server [Server] The settings relating to the NTP server, the FTP server and the mail server can be configured on the "Server" page. The "Server" page has [NTP], [FTP] and [Mail] tabs. Configure the settings relating to time adjustment according to the NTP server [NTP] Select the [NTP] tab on the "Server" page. (+ Page 60) The settings when time is adjusted according to the NTP (Network Time Protocol) server can be configured on this tab. [Time adjustment] Select "On" or "Off" to determine whether or not to adjust the time according to the NTP server. [NTP server address] Enter the NTP server address when adjusting the time using the NTP server. The name of the NTP server is available only when selecting "Manual" or "Auto" for the "Network" page - the [DNS] tab. Enter up to 255 alphanumeric characters including hyphens (-) and periods (.). Important: • When "On" is selected for the DHCP setting of the recorder, the setting for "Time adjustment" will not be activated in case the time of recorder is ±1 000 seconds or more different from that of the NTP server.
96 Configure the settings relating to the FTP server [FTP] Select the [FTP] tab on the "Server" page. (+ Page 60) The basic settings such as the FTP server address, user name and password and the setting to transmit alarm images at an event occurrence can be configured on this tab. [FTP server address] Enter an address or name of the FTP server to transmit images. The name of the FTP server is available only when selecting "Manual" or "Auto" for the "Network" page - the [DNS] tab. Enter up to 255 alphanumeric characters including hyphens (-) and periods (.). [User name] Enter a user name (login name) to access the FTP server. Enter up to 32 alphanumeric characters excluding (&) listed as follows. Note: • Available characters: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z 0 1 2 3 4 5 6 7 8 9 ! " # $ % ' ( ) * + , - . / :; < = > ? @ [ ] ^ _ ` { | } ~ [Password] Register a password to be entered when transmitting imag- es to the FTP server. Enter up to 32 alphanumeric characters excluding "&" listed in the description of "Available charac- ters". An entered character for the password will be dis- played as "∗" or "·". [Mode] Select the mode to transmit images to the FTP server. Change to "Passive" when sending images is difficult with "Active". Change to "Passive" when sending images is diffi- cult with "Sequencial". ■ Image transmission by alarm [Server directory] Enter a directory of the server. Enter up to 128 alphanumeric characters (excluding "& *: < > ? ~") listed in the description of "Available characters". Enter up to 255 alphanumeric characters excluding "& * : < > ? | ~ " listed in the descrip- tion of "Available characters". [Duration-pre] Select the duration of the images recorded by pre-event recording to be transmitted from the following. Off/1 s - 10 s (in 1 second intervals) Default: Off Important: • The setting for "Duration-pre" is the shortest duration to transmit images recorded by pre-event recording. The actual duration of the recorded images to be transmitted will be longer than the setting. • Images recorded by pre-event recording will not be transmitted when pre-event recording is not to be per- formed. Configure the setting to perform pre-event recording to transmit images recorded by pre-event recording. Refer to page 80 for further information on how to configure the settings relating to the pre-event recording. [Duration-post] Select the duration of the transmitted images for the post- event recording. Off/1 s - 10 s (in 1 second intervals) Default: 5 s [Alteration detection] Select "On" or "Off" to determine whether or not to attach an alteration detection code to recorded images to be transmit- ted using the viewer software when an alarm occurs.
97 Configure the settings relating to the mail notification [Mail] Select the [Mail] tab on the "Server" page. (+ Page 60) The settings of alarm mail notice, the settings of error report mail (+ Operating Instructions (PDF)) and the settings to use the mail functions can be configured on this tab. [SMTP server address] Enter an IP address or a name of the SMTP server to send e-mails. The name of the SMTP server is available only when selecting "Manual" or "Auto" for the "Network" page - the [DNS] tab. Enter up to 255 alphanumeric characters includ- ing hyphens (-) and periods (.). The name of the SMTP server is available only when selecting "Manual" or "Auto" for the "Network" page - the [DNS] tab. Enter up to 255 alphanu- meric characters including hyphens (-) and periods (.). [SMTP port number] Enter the port number of the SMTP server. 1 - 65535 Default: 25 [POP server address] Enter an IP address or name of the POP server to be used for POP before SMTP authentication. The name of the POP server is available only when selecting "Manual" or "Auto" for the "Network" page - the [DNS] tab. Enter up to 255 alphanumeric characters including hyphens (-) and periods (.). [Type] Select the authentication method to send e-mails from the following. None /POP before SMTP/SMTP Default: None [Type - User name] Enter the user name to be required for the authentication. Enter up to 32 alphanumeric characters excluding "&" listed in the description of "Available characters". (+ Page 96) [Type - Password] Enter the password to be required together with the user name for the authentication. Enter up to 32 alphanumeric characters excluding "&" listed in the description of "Available characters". An entered character for the pass- word will be displayed as "∗" or "·". Enter up to 32 alphanu- meric characters excluding "&" listed in the description of "Available characters" (+ page 96). An entered character for the password will be displayed as "∗" or "·". [Sender's address] Enter the mail address of a sender. Entered mail addresses will be displayed in the "From" (sender) line. Enter up to 255 alphanumeric characters including hyphens (-), periods (.), underscore marks (_) and @. Entered address will be dis- played in the sender's line ("From" field) of the received mail. Enter up to 127 alphanumeric characters including hyphens (-), periods (.), underscore marks (_) and @. ■ Destination address [Address 1] Enter the mail addresses of the recipients of the alarm mail (+ Operating Instructions (PDF)) and the warning mail (+ Operating Instructions (PDF)). Enter up to 255 alphanumeric characters including hyphens (-), periods (.), underscore marks (_) and @. Check the desired mail type (warning/alarm) to be sent. Up to 4 destinations can be registered. To add destinations, select the [Setup] of "Other destinations".
98 [Other destinations] Add other destinations. When the [Setup] button is selected, the following page will be displayed. When the [Setup] but- ton is selected, the following page will be displayed. Enter the desired mail address and mail type for "Address 1" - "Address 4". The setup procedure is the same as [Address 1] When the [Back] button is selected, the setup page will be closed, and the display will return to the [Mail] tab.
99 Configure the settings relating to network [Network] The basic network settings required to operate this unit using a PC via a network such as a LAN can be co\ nfigured on the "Network" page. The settings relating to the Panasonic alarm protocol and the settings relating to the resolution and rate to transmit live images can also be configured on this page. The "Network" page has [Basic], [DNS], [DDNS], [SNMP], [Panasonic alarm \ protocol] and [Transmission] tabs. Configure the basic settings relating to a network [Basic] Select the [Basic] tab on the "Network" page. (+ Page 60) The basic settings relating to a network can be configured on this tab. [HTTP port number] Specify the HTTP port number to be used to send images from the unit. It is unnecessary to change it for normal use. 1 - 65535 Default: 80 Note: • Depending on the network settings, network communi- cation may not be established if the http port number has been changed. In this case, refer to the administra- tor of each network. In this case, refer to the administra- tor of the network. • The following numbers and the FTP port number are unavailable for the HTTP port number. 20, 21, 23, 25, 42, 53, 67, 68, 69, 79, 105, 110, 123, 161, 162, 546, 547, 995, 10001, 10002, 10003, 10004, 10005, 10006, 10007 [FTP port number] Designate the FTP port number of the recorder. It is unnecessary to change it for normal use. 1 - 65535 Default: 21 Note: • The following numbers and the HTTP port number are unavailable for the FTP port number. 20, 23, 25, 42, 53, 67, 68, 69, 79, 80, 105, 110, 123, 161, 162, 546, 547, 995, 10001, 10002, 10003, 10004, 10005, 10006, 10007 ■ Network Port The setting for the network port on the rear panel of the recorder is configured. This setting is required to operate the recorder from a PC connected via a network using the network ports. [DHCP] Select "On" or "Off" to determine whether or not to use the DHCP server. Select "On" to obtain an IP address, a subnet mask and a gateway address from the DHCP server. Set to "Off" when entering the addresses above manually. The IP address, subnet mask and default gateway obtained from the DHCP server are displayed on each setting area. Default: Off Note: • When the setting of DHCP is changed from "On" to "Off", the setting of DNS will be automatically changed to "Off".
100 [IP address] When "Off" is selected for "DHCP", enter an IP address. Enter 4 units from the decimal numbers (0-255). Default: 192.168.0.250 [Subnet mask] Enter a subnet mask according to the network environment when "Off" is selected for "DHCP". Enter 4 units from the decimal numbers (0-255). Default: 255.255.255.0 [Default gateway] Enter the IP address of the gateway according to the net- work environment when "Off" is selected for "DHCP". Enter 4 units from the decimal numbers (0-255). Default: 192.168.0.1 [Line speed] Specify the line speed for data transmission. Auto: Line speed will be applied automatically. 10M-Half: 10 Mbps half-duplex 10M-Full: 10 Mbps full-duplex 100M-Half: 100 Mbps half-duplex 100M-Full: 100 Mbps full-duplex Default: Auto ■ Maintenance port The setting for the maintenance port behind the front cover of the recorder is configured. This setting is required to maintain and support the recorder from a PC connected via a network using the maintenance port. [IP address] When "Off" is selected for "DHCP", enter an IP address. Enter 4 units from the decimal numbers (0-255). Default: 192.168.2.250 [Subnet mask] Enter a subnet mask according to the network environment when "Off" is selected for "DHCP". Enter 4 units from the decimal numbers (0-255). Default: 255.255.255.0 Important: • The settings of "Network Port" and "Maintenance Port" should be on a different subnet. [Line speed] Displays the line speed for data transmission. It is impossible to change the setting value.