Page 41
installation, Section 300 Cabinet Installation Issue 2 August 16, 1993 Test Phone Guidelines . . . A DSS/72 can be connected to the display phone for text entry. installation 1. 2. 3. The test terminal (CN3) on the DBS Connector Panel can be used to connect a display phone for programming. The test terminal can be used for initial programming before extension cabling is completed. The test terminal is turned on by flipping SW 1 on the Connector Panel to the “Test” position. When SW 1 is...
Page 42
Installation, Section 300 Cabinet Installation Issue 2 August l6, 1993 rigwe 3-18.Test telephone connection Test Phone for Prcgramrm vwo-Conduclar Cable (Port 7 SW1 ST-TEST ST-Pans 7 and 8 are mnneclod through the MDF CN3 / Q To the DSS To the telephone
Page 43
installation, Section 300 Issue 2 Chapter 4. Trunks and Lines Trunks and Lines August 16, 1993 This chapter describes trunk and line installation. Some peripheral equipment also requires trunk and/or line interfaces (door phones or power failure units, for example). See Chapter 5 for instructions on connecting peripheral equipment through trunks or lines. 4-l
Page 44
Installation, Section 300 Issue 2 Trunks and Lines August 16, 1993 Trunks Trunk Connectors Each DBS cabinet is provided with one main trunk connector, which is labeled CN 1. In addition, a trunk expansion connector (VB-43 120) can be added to the DBS to provide eight additional trunk connections. (The trunk expansion connector is also labeled CN 1.) Figure 4- 1 shows the maximum number of trunks that can be connected when both trunk connectors are used with a DBS 96. Figure 4-1. DBS trunk...
Page 45
Installation, Section 300 Issue 2 Trunks and Lines August 16,1993 The number of trunks that can be connected through the main trunk connector depends on the type of system you have and the number of trunk cards installed. Table 4-l shows the main trunks and expansion trunks available with each system type. Chapter 6 includes trunk maximums for two-cabinet systems. Table 4-1. Main trunks and expansion trunks provided with each system type System Type Main Trunk Numbers Expansion Trunk Numbers DBS...
Page 46
Installation, Section 300 Trunks and Lines Issue 2 August 16, J993 Table 4-2. Pinouts and trunk numbers for the main Table 43. Pinouts and trunk numbers for trunk trunk connector. expansion connector CNI _ RI,-HL 31 6T HL-RI) 6 6R RD-OR 32 7T ()R-RI) 7 7R RIM iN 33 8T (;N-RI) x 8R lRK2 RI)-BR 34 9T Fun&on Trunk I Trunk 2 Trunk 3 Trunk 4 Ttunk .s Tnmk 6 Trunk 7 ‘Trunl: [I)HS 72. l)HS Oh) Trunk Color SM (‘ode t EC ‘fi-RK WH-BL BL-WH WH-OR OR-WH WH-(;N CiN-WH WH-BR BR-WH...
Page 47
Installation, Section 300 Issue 2 Trunks and Lines August 16, 1993 LooMtart Trunks Guidelines . . Installation 1. 2. Two versions of the loop-start trunk are available: the four-port version (VB- 435 IO) and the eight-port version (VB-435 11). The following procedure covers loop-start trunk installation using the main trunk connector. For instructions on using the expansion trunk connector, see “Trunk and Line Expansion” on page 4-41 For pinouts and color codes for the main trunk...
Page 48
Installation, Section 300 Issue 2 Trunks and Lines August 16,1993 l Both ground start and DID trunks requirF!!n external -4XV power supply. The following table shows -4XV power consumption for one- and two-cabinet systems. Table 4-4. -48V current consumption for ground-start and DID trunks Current Consumption (Output voltage = 48 k 4 V System Size Ripple voltage = k500 m VP-p) One-cabinet system 1 Amp Two-cabinet system 2 Amps l The following -4XV power supplies have been tested with DBS...
Page 49
Installation, Section 300 Trunks and Lines issue 2 August 16,1993 4-2. -48Vpower supply installation CN2 RG -48V SG SYN RG +24V GND C B M ZO Zl 22 23 24 RE2 REl 3. 4. 5. 6. Ground the positive side of the -48V power supply to the building ground. Note: Resistance to ground must be 10 Ohms or less, and the ground cable must be 18 AWG or larger. Install power-surge protectors between the wall outlet and the -48V power supply. Use a standard 50-pin cable to connect the trunks from the MDF to...
Page 50
Installation, Section 300 Issue 2 Trunks and Lines August 16,1993 Tl Interface Guidelines Read the following guidelines before beginning Tl installation. Installation instructions begin on page 4-1X. Hardware Requirements l The Tl requires the following DBS hardware. Tab!e 4-6. TI Hardware requi:emenb for single-cabinet systems CPC-B 4.0 SCC-B Tl Trunk Card Tl MDF Card Sync Unit (VB-43411) (VB-43421) (VB-43561) (VB-43562) (VB-43563) I 1 1 1 (See Note 1.) (See Noted; 2 and 3.) Notes: 1....