Page 11

11
Multi-unit Connection (PS•Data)
A maximum of four units can be connected in a daisy fashion, from SPOT OUT to SPOT IN and so on, and finally from SPOT
OUT to the monitor.
SD RD
IN IN
CAMERA RS485
A B A B G
VS/VD SPOT DATAALARM / REMOTE
MODE
SIGNAL GND
43 21
OUT OUT
INOUT
43 21
TR
IN IN
CAMERA RS485
A B A B G
VS/VD SPOT DATAALARM / REMOTE
MODE
SIGNAL GND
43 21
OUT OUT
INOUT
43 21
SD RD
IN IN
CAMERA RS485
A B A B G
VS/VD SPOT DATAALARM / REMOTE
MODE
SIGNAL GND
43 21
OUT OUT
INOUT
43 21
TR
IN IN
CAMERA...

Page 12

12
SD RD
IN IN
CAMERA RS485
A B A B G
VS/VD SPOT DATAALARM / REMOTE
MODE
SIGNAL GND
43 21
OUT OUT
IN
OUT43 21
TR
IN IN
CAMERA RS485
A B A B G
VS/VD SPOT DATAALARM / REMOTE
MODE
SIGNAL GND
43 21
OUT OUT
IN
OUT43 21
1 ch
2 ch
3 ch 4 ch
5 ch
6 ch
7 ch
8 ch
System Controller WV-CU360C
Branch Connector
Unit Address 1 Unit Address 2 VS/VD INPUT
VD OUT
Termination ON
MODE
VS/VD OUTPUT
4-Line
SIGNAL
GNDALARM/REMOTEOUT
IN
VIDEO 16 15 14 13 12 11 10 9 8
16 15 14 13 12 11 10 9 87654 21
765433
21
PLAY INREC OUTSPOT...

Page 13

13
ON
OFFPOWER
REMOTO
TIMER
OPERATE
FULL
HDD
SEQUENCESET LOCK
ALARM
ALARM
RESET
ALARM
SUSPENDMULTISCREEN
SELECT
SET UP
/ESCGROUP
SELECT
SPOTMULTISCREEN
DAYLIGHT SAVINGSEL-ZOOM
COPYREC PREVIEWINDEXSTOP PLAY/    PAUSE REC
FWD REV
ALARM SEARCH
DISPLAYREC STOP1234
1314151691011125678
Digital Disk
Recorder
WJ-HD
FS16
ON
OFFPOWER
Spot Monitor
Multiscreen Monitor
Digital Disk Recorder WJ-HD500A
Extension Unit WJ-HDE500
(with optional HDs) Remote Controller
WV-CU50
8 Camreras
HDD 1HDD 2HDD 3HDD 4Extension Unit...

Page 14

14
Matrix Switcher Connection (Camera Communication)
The WJ-SX350 and WV-CU360C are typically combined with the WJ-MP204C when using the Camera Communication
Protocol. Ordinary cameras are connected directly with the Matrix Switcher, different from cameras having control functions.
TR
IN IN
CAMERA RS485
A B A B G
VS/VD SPOT DATAALARM / REMOTE
MODE
SIGNAL GND
43 21
OUT OUT
IN
OUT43 21
TR
IN IN
CAMERA RS485
A B A B G
VS/VD SPOT DATAALARM / REMOTE
MODE
SIGNAL GND
43 21
OUT OUT
IN
OUT43 21
OFFONPOWER...

Page 15

15
OFFSW position
VS/VD
Unit Number Setting
A rotary switch is placed on the front panel. It specifies the WJ-MP204C unit number in a PS•Data protocol system, or camera
unit numbers in a Camera Communication Protocol system.
8Setting the unit number
1  Turn off the power switch of the unit.
2  Use a screw driver to rotate the UNIT switch so that the arrow comes to the number you wish.
3  Turn on the power switch.
Notes:
• The unit number can be specified in the setup menu when the UNIT switch is set to...

Page 16

16
8PS•Data
Address Assignment
8Camera Communication Protocol
As shown in the table, the UNIT switch determines the camera unit numbers. 
Address Assignment
Alarm/Remote Terminal Setting
The rear of the unit is provided with an 11-pin terminal, ALARM/REMOTE.
Pins from #1 to #5 perform as follows.
Pin #1 supplies an active output for the duration specified by the ALARM OUTPUT in the setup. 
The output type is a low-active open collector with a capacity of 16 V DC, 100 mA maximum.
Pin #2 accepts an alarm...

Page 17

17
8Alarm input 
Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in the setup, and the internal connector remains in
the default position (CN703, ALM IN): 
Pin #6 accepts CH 1 alarm input from the connected sensor.
Pin #7 accepts CH 2 alarm input from the connected sensor.
Pin #8 accepts CH 3 alarm input from the connected sensor.
Pin #9 accepts CH 4 alarm input from the connected sensor.
8Alarm output
Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in the setup,...

Page 18

18
•Basic Connection
•Daisy Connection
RS-485 Terminal Connection (Camera
Communication)
These terminals are connected with system devices using
the Camera Communication Protocol in 4-line full duplex or
2-line half duplex mode specified with the DIP switch set-
ting.
Notes:
• Use a data grade, shielded and twisted cable suited to
RS-485. The maximum allowable cable length is 4 000
ft (1 200m).
• Termination should be made at both ends of the data
line, while being open at intermediate devices....

Page 19

19
Prior to setup
Confirmation
1. Connections and switch settings are complete.
2. Switch on the power of the connected system devices
including the monitor that displays the menus.
3. Turn on the power of the WJ-MP204C. 
4. When setting at the camera site, remove the front cover
from the unit to make access possible to the buttons on
the front panel.
5. When setting with use of a WV-CU360C System
Controller, confirm that the OPERATE indicator is lit on
the Controller, meaning that the unit is ready...

Page 20

20
Setup menus
There are two setup menu groups depending on the communication protocol used in the system, menus for PS•Data and for
the Camera Communication Protocol.  MODE DIP switch # 3 on the rear of the unit is set to the position of the used protocol,
and it specifies what menu group is displayed on the monitor. Menu trees are shown below for two protocols. 
COMMUNICATION
UNIT ADDRESS
BAUD RATE
DATA BIT
PARITY CHECK
STOP BIT
WAIT TIME 
SYSTEM
ALARM MODE
MONITOR SPOT...