Page 11
11 Multi-unit Connection (PS•Data) A maximum of four units can be connected in a daisy fashion, from SPOT OUT to SPOT IN and so on, and finally from SPOT OUT to the monitor. SD RD IN IN CAMERA RS485 A B A B G VS/VD SPOT DATAALARM / REMOTE MODE SIGNAL GND 43 21 OUT OUT INOUT 43 21 TR IN IN CAMERA RS485 A B A B G VS/VD SPOT DATAALARM / REMOTE MODE SIGNAL GND 43 21 OUT OUT INOUT 43 21 SD RD IN IN CAMERA RS485 A B A B G VS/VD SPOT DATAALARM / REMOTE MODE SIGNAL GND 43 21 OUT OUT INOUT 43 21 TR IN IN CAMERA...
Page 12
12 SD RD IN IN CAMERA RS485 A B A B G VS/VD SPOT DATAALARM / REMOTE MODE SIGNAL GND 43 21 OUT OUT IN OUT43 21 TR IN IN CAMERA RS485 A B A B G VS/VD SPOT DATAALARM / REMOTE MODE SIGNAL GND 43 21 OUT OUT IN OUT43 21 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8 ch System Controller WV-CU360C Branch Connector Unit Address 1 Unit Address 2 VS/VD INPUT VD OUT Termination ON MODE VS/VD OUTPUT 4-Line SIGNAL GNDALARM/REMOTEOUT IN VIDEO 16 15 14 13 12 11 10 9 8 16 15 14 13 12 11 10 9 87654 21 765433 21 PLAY INREC OUTSPOT...
Page 13
13 ON OFFPOWER REMOTO TIMER OPERATE FULL HDD SEQUENCESET LOCK ALARM ALARM RESET ALARM SUSPENDMULTISCREEN SELECT SET UP /ESCGROUP SELECT SPOTMULTISCREEN DAYLIGHT SAVINGSEL-ZOOM COPYREC PREVIEWINDEXSTOP PLAY/ PAUSE REC FWD REV ALARM SEARCH DISPLAYREC STOP1234 1314151691011125678 Digital Disk Recorder WJ-HD FS16 ON OFFPOWER Spot Monitor Multiscreen Monitor Digital Disk Recorder WJ-HD500A Extension Unit WJ-HDE500 (with optional HDs) Remote Controller WV-CU50 8 Camreras HDD 1HDD 2HDD 3HDD 4Extension Unit...
Page 14
14 Matrix Switcher Connection (Camera Communication) The WJ-SX350 and WV-CU360C are typically combined with the WJ-MP204C when using the Camera Communication Protocol. Ordinary cameras are connected directly with the Matrix Switcher, different from cameras having control functions. TR IN IN CAMERA RS485 A B A B G VS/VD SPOT DATAALARM / REMOTE MODE SIGNAL GND 43 21 OUT OUT IN OUT43 21 TR IN IN CAMERA RS485 A B A B G VS/VD SPOT DATAALARM / REMOTE MODE SIGNAL GND 43 21 OUT OUT IN OUT43 21 OFFONPOWER...
Page 15
15 OFFSW position VS/VD Unit Number Setting A rotary switch is placed on the front panel. It specifies the WJ-MP204C unit number in a PS•Data protocol system, or camera unit numbers in a Camera Communication Protocol system. 8Setting the unit number 1 Turn off the power switch of the unit. 2 Use a screw driver to rotate the UNIT switch so that the arrow comes to the number you wish. 3 Turn on the power switch. Notes: • The unit number can be specified in the setup menu when the UNIT switch is set to...
Page 16
16 8PS•Data Address Assignment 8Camera Communication Protocol As shown in the table, the UNIT switch determines the camera unit numbers. Address Assignment Alarm/Remote Terminal Setting The rear of the unit is provided with an 11-pin terminal, ALARM/REMOTE. Pins from #1 to #5 perform as follows. Pin #1 supplies an active output for the duration specified by the ALARM OUTPUT in the setup. The output type is a low-active open collector with a capacity of 16 V DC, 100 mA maximum. Pin #2 accepts an alarm...
Page 17
17 8Alarm input Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in the setup, and the internal connector remains in the default position (CN703, ALM IN): Pin #6 accepts CH 1 alarm input from the connected sensor. Pin #7 accepts CH 2 alarm input from the connected sensor. Pin #8 accepts CH 3 alarm input from the connected sensor. Pin #9 accepts CH 4 alarm input from the connected sensor. 8Alarm output Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in the setup,...
Page 18
18 •Basic Connection •Daisy Connection RS-485 Terminal Connection (Camera Communication) These terminals are connected with system devices using the Camera Communication Protocol in 4-line full duplex or 2-line half duplex mode specified with the DIP switch set- ting. Notes: • Use a data grade, shielded and twisted cable suited to RS-485. The maximum allowable cable length is 4 000 ft (1 200m). • Termination should be made at both ends of the data line, while being open at intermediate devices....
Page 19
19 Prior to setup Confirmation 1. Connections and switch settings are complete. 2. Switch on the power of the connected system devices including the monitor that displays the menus. 3. Turn on the power of the WJ-MP204C. 4. When setting at the camera site, remove the front cover from the unit to make access possible to the buttons on the front panel. 5. When setting with use of a WV-CU360C System Controller, confirm that the OPERATE indicator is lit on the Controller, meaning that the unit is ready...
Page 20
20 Setup menus There are two setup menu groups depending on the communication protocol used in the system, menus for PS•Data and for the Camera Communication Protocol. MODE DIP switch # 3 on the rear of the unit is set to the position of the used protocol, and it specifies what menu group is displayed on the monitor. Menu trees are shown below for two protocols. COMMUNICATION UNIT ADDRESS BAUD RATE DATA BIT PARITY CHECK STOP BIT WAIT TIME SYSTEM ALARM MODE MONITOR SPOT...