    Have a look at the manual Panasonic Data Multiplex Unit Wj Mp204c Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11
    Multi-unit Connection (PS•Data)
    A maximum of four units can be connected in a daisy fashion, from SPOT OUT to SPOT IN and so on, and finally from SPOT
    OUT to the monitor.
    SD RD
    IN IN
    CAMERA RS485
    A B A B G
    VS/VD SPOT DATAALARM / REMOTE
    MODE
    SIGNAL GND
    43 21
    OUT OUT
    INOUT
    43 21
    TR
    IN IN
    CAMERA RS485
    A B A B G
    VS/VD SPOT DATAALARM / REMOTE
    MODE
    SIGNAL GND
    43 21
    OUT OUT
    INOUT
    43 21
    SD RD
    IN IN
    CAMERA RS485
    A B A B G
    VS/VD SPOT DATAALARM / REMOTE
    MODE
    SIGNAL GND
    43 21
    OUT OUT
    INOUT
    43 21
    TR
    IN IN
    CAMERA RS485
    A B A B G
    VS/VD SPOT DATAALARM / REMOTE
    MODE
    SIGNAL GND
    43 21
    OUT OUT
    INOUT
    43 21
    5 ch
    6 ch
    7 ch 8 ch
    1 ch
    2 ch
    3 ch
    4 ch
    System Controller WV-CU360C
    Unit Address 2 Unit Address 1
    VS/VD OUT
    SPOT IN
    SPOT
    OUT
    Termination OFFMODE
    VS/VD IN VS/VD OUT
    SPOT IN
    4-Line
    Termination ON
    Controller No. 1
    4-Line
    Termination OFF
    Panasonic Security 
    Data mode Monitor
    MODE
    Panasonic Security 
    Data mode
    OPERATELOGIN ALARM
    CAM SETUPPROGRAM
    PROGRAM
    PRESETUNIT AIRISCLOSE OPEN
    NEAR FAR
    WIDE TELEFOCUSZOOM AUTO FOCUSIRIS RESET
    AUTO SETUPALM SUSPENDFUNCTIONCAM FUNCTIONMULTI SCREEN SELECTDEF
    WIPEREL-ZOOMSHIFTALM RESETVTR   CAM
    STILL
    –+ALM RECALL
    PATROL
    LEARN PATROL
    STOPAUX 1AUX 2B/W
    UNIT
    SEQ PAUSE
    SLOWSEQUENCE
    PATROL PLAY
    HOME/PRESETUNIT B
    MONCAM
    LOGOUT
    ESC SET
    UP
    LRDOWN
    BUSY PROHIBITED
    MONITOR
    UNITCAMERA
    System Controller
    WV-CU360
    Video signalRS485 signal
    (Panasonic Security Data mode)
    Camera Site
    Control SiteVD OUT
    13 ch
    14 ch
    15 ch 16 ch
    9 ch
    10 ch
    11 ch
    12 ch
    Unit Address 4 Unit Address 3
    VS/VD IN VS/VD OUT
    SPOT IN
    SPOT OUTSPOT OUT
    SPOT SW OUT IN OUT IN SPOT SW IN OUT
    Termination OFFMODE
    VS/VD IN
    4-Line
    4-Line
    Termination ON
    Panasonic Security 
    Data mode
    MODE
    Panasonic Security 
    Data mode
    SPOT OUT
    0987654321
    UNIT #1
    0987654321
    UNIT #2
    0987654321
    UNIT #3
    0987654321
    UNIT #4 
    						
    							12
    SD RD
    IN IN
    CAMERA RS485
    A B A B G
    VS/VD SPOT DATAALARM / REMOTE
    MODE
    SIGNAL GND
    43 21
    OUT OUT
    IN
    OUT43 21
    TR
    IN IN
    CAMERA RS485
    A B A B G
    VS/VD SPOT DATAALARM / REMOTE
    MODE
    SIGNAL GND
    43 21
    OUT OUT
    IN
    OUT43 21
    1 ch
    2 ch
    3 ch 4 ch
    5 ch
    6 ch
    7 ch
    8 ch
    System Controller WV-CU360C
    Branch Connector
    Unit Address 1 Unit Address 2 VS/VD INPUT
    VD OUT
    Termination ON
    MODE
    VS/VD OUTPUT
    4-Line
    SIGNAL
    GNDALARM/REMOTEOUT
    IN
    VIDEO 16 15 14 13 12 11 10 9 8
    16 15 14 13 12 11 10 9 87654 21
    765433
    21
    PLAY INREC OUTSPOT OUT DATA
    INCAMERA
    SW INMULTI
    SCREEN OUT
    Video Multiplexer WJ-FS316/416 8 Cameras
    Termination ON
    Controller No. 1
    4-Line
    Termination OFF
    Panasonic Security 
    Data mode
    MonitorMODE
    Panasonic Security 
    Data mode
    OPERATELOGIN ALARM
    CAM SETUPPROGRAM
    PROGRAM
    PRESET
    UNIT AIRISCLOSE OPEN
    NEAR FAR
    WIDE TELEFOCUS
    ZOOM AUTO FOCUSIRIS RESET
    AUTO SETUPALM SUSPENDFUNCTIONCAM FUNCTION
    MULTI SCREEN SELECTDEF
    WIPEREL-ZOOM
    SHIFTALM RESETVTR   CAM
    STILL
    –
    +
    ALM RECALL
    PATROL
    LEARN PATROL
    STOPAUX 1AUX 2B/WUNIT
    SEQ PAUSE
    SLOWSEQUENCEPATROL PLAYHOME/PRESET
    UNIT B
    MONCAM
    LOGOUT
    ESC SET
    UP
    LR
    DOWN
    BUSY PROHIBITEDMONITOR
    UNITCAMERASystem ControllerWV-CU360
    Video signal
    RS485 signal
    (Panasonic Security Data mode)
    Camera Site
    Control Site
    0987654321UNIT0987654321UNIT
    Video Multiplexer Connection (PS•Data)
    To connect with ordinary cameras that do not have camera control functions, a Video Multiplexer is installed with the WJ-
    MP204C units at the camera site. 
    						
    							13
    ON
    OFFPOWER
    REMOTO
    TIMER
    OPERATE
    FULL
    HDD
    SEQUENCESET LOCK
    ALARM
    ALARM
    RESET
    ALARM
    SUSPENDMULTISCREEN
    SELECT
    SET UP
    /ESCGROUP
    SELECT
    SPOTMULTISCREEN
    DAYLIGHT SAVINGSEL-ZOOM
    COPYREC PREVIEWINDEXSTOP PLAY/    PAUSE REC
    FWD REV
    ALARM SEARCH
    DISPLAYREC STOP1234
    1314151691011125678
    Digital Disk
    Recorder
    WJ-HD
    FS16
    ON
    OFFPOWER
    Spot Monitor
    Multiscreen Monitor
    Digital Disk Recorder WJ-HD500A
    Extension Unit WJ-HDE500
    (with optional HDs) Remote Controller
    WV-CU50
    8 Camreras
    HDD 1HDD 2HDD 3HDD 4Extension Unit  WJ-HDEOPERATE
    System Controller
    POWER
    ON
    OFFALARM
    Data Multiplex Unit WJ-MP204
    ALARM
    SUSPENDPOWER
    ON
    OFFALARM
    Data Multiplex Unit WJ-MP204
    ALARM
    SUSPEND
    System Controller
    WV-CU360C
    LAN Ethernet
        10 Base-T or
    100 Base-TX WJ-HDB502
    Network
    Interface
    BoardPS
    •Data WJ-MP204C WJ-MP204CA
    Digital Disk Recorder Connection (PS•Data)
    To connect with ordinary cameras that do not have camera control functions, a Digital Disk Recorder is installed with the WJ-
    MP204C units at the camera site. When an optional Network Interface Board is installed in the recorder, monitoring via the
    Internet is available. For more information, refer to the manual included with the recorder. 
    						
    							14
    Matrix Switcher Connection (Camera Communication)
    The WJ-SX350 and WV-CU360C are typically combined with the WJ-MP204C when using the Camera Communication
    Protocol. Ordinary cameras are connected directly with the Matrix Switcher, different from cameras having control functions.
    TR
    IN IN
    CAMERA RS485
    A B A B G
    VS/VD SPOT DATAALARM / REMOTE
    MODE
    SIGNAL GND
    43 21
    OUT OUT
    IN
    OUT43 21
    TR
    IN IN
    CAMERA RS485
    A B A B G
    VS/VD SPOT DATAALARM / REMOTE
    MODE
    SIGNAL GND
    43 21
    OUT OUT
    IN
    OUT43 21
    OFFONPOWER
    SIGNAL
    GND1
    3
    2
    4
    1
    1
    2
    2
    3
    3
    4
    4
    5
    5
    6
    6
    7
    7
    8
    8
    9
    9
    10
    10
    11
    11
    12
    12
    13
    13
    14
    14
    15
    15
    16
    16
    MONITOR OUT CAMERA  IN
    5
    7
    6
    8
    17
    17
    18
    18
    19
    19
    20
    20
    21
    21
    22
    22
    23
    23
    24
    24
    25
    25
    26
    26
    27
    27
    28
    28
    29
    29
    30
    30
    31
    31
    32
    32
    MONITOR OUT CAMERA  IN
    ALARM OUT 5-8ALARM OUT 1-4ALARM IN RS-232C DATA IN RS485
    234 G
    N
    DBAG
    N
    DBA1
    System Controller WV-CU360CMatrix Switcher
    WJ-SX350
    Data Multiplex Unit 
    WJ-MP204CData Multiplex Unit
    WJ-MP204C
    Camera Camera
    Monitor
    Unit Address 1
    Unit Address 2
    Termination
    ON
    MODE
    2-Line
    Camera communi-
    cation mode
    1 ch
    2 ch
    3 ch 4 ch 5 ch
    6 ch
    7 ch
    8 ch
    Video signal
    RS485 signal (camera site)
    RS485 signal (controller site)
    OPERATE LOCKALARM
    AUTO/+IRIS
    CLOSE OPEN
    NEAR FAR
    TELE WIDEFOCUS
    ZOOM SPOTMULTI SELECTVTR
    CAMALT
    FUNCTIONALM RESETALM SUSPENDALL RESETSEQUENCE
    PRE-POSIEL-ZOOMMULTI
    SCREEN
    IRIS RESET
    CAMERA  SET SET UPSTILL
    ON/OFF OFF ONAUTO
    FOCUS HOME/-UNITCAM
    ESC SET
    CAMERA SITE CONTRIL
    UP
    LR
    DOWN
    CAMERAUNITSystem ControllerFor  MultiplexerWV-CU
    AUX  2
    AUX  1
    T/L MODE
    0987654321
    0987654321
    UNITUNIT
    8 Cameras
    Termination
    OFF
    MODE
    VD OUT
    2-Line
    Camera communi-
    cation mode
    Notes:
    • Unstable camera response may occur in a daisy-chain connection.
    • For setting up the WV-CU360C and other units, refer to the manual included with the units. 
    						
    							15
    OFFSW position
    VS/VD
    Unit Number Setting
    A rotary switch is placed on the front panel. It specifies the WJ-MP204C unit number in a PS•Data protocol system, or camera
    unit numbers in a Camera Communication Protocol system.
    8Setting the unit number
    1  Turn off the power switch of the unit.
    2  Use a screw driver to rotate the UNIT switch so that the arrow comes to the number you wish.
    3  Turn on the power switch.
    Notes:
    • The unit number can be specified in the setup menu when the UNIT switch is set to 0.
    • Position #9 is not allowed to be set, because it is reserved.
    • Specify a unique number for each unit when connecting more than one unit in a data communication chain.
    DIP Switch Setting
    A 6-bit DIP switch mounted on the rear panel specifies communication mode and sync setup. The default position is marked
    with an asterisk * in the table below.
    Bit 1 specifies the setup for synchronization. Refer to page 23 VS/VD IN and OUT for details. 
    Bit 2 is reserved.
    Bit 3 specifies the communication protocol used in the system.
    Bit 4 is reserved.
    Bit 5 specifies the termination in the communication chain. 
    Bit 6 specifies RS-485 communication mode conducted via DATA port or RS-485 terminal. Set it to 4-line when PS
    •Data is
    used.
    1OFF
    ON23456
    Function
    ON
    Bit 6 Bit 5
    Bit 4
    Bit 3
    Bit 2
    Bit 1
    RS-485 mode Line termination
    Reserved
    Protocol
    Reserved
    Sync setup
    4-line full duplex* Off
    Fixed to OFF*
    PS
    •Data* Fixed to OFF*
    THROUGH*
    2-line half duplex On*
    Not used
    Camera Communication
    Not used
    0987654321
    UNIT 
    						
    							16
    8PS•Data
    Address Assignment
    8Camera Communication Protocol
    As shown in the table, the UNIT switch determines the camera unit numbers. 
    Address Assignment
    Alarm/Remote Terminal Setting
    The rear of the unit is provided with an 11-pin terminal, ALARM/REMOTE.
    Pins from #1 to #5 perform as follows.
    Pin #1 supplies an active output for the duration specified by the ALARM OUTPUT in the setup. 
    The output type is a low-active open collector with a capacity of 16 V DC, 100 mA maximum.
    Pin #2 accepts an alarm reset pulse (input) that makes the unit reset the alarm mode. 
    A no-voltage make-contact is accepted.
    Pin #3 supplies an alarm reset pulse (output) when the unit resets the alarm mode.
    The output type is 0 V (active)/5 V for the default setting, or a low-active open collector with controllable capacity of 16 V
    DC, 100 mA maximum after changing an internal switch (SW 704).
    Pin #4 accepts a spot switching pulse (input) from other units in a multi-unit connection.
    A no-voltage make-contact is accepted.
    Pin #5 supplies a spot switching pulse (output) to other units when the unit selects a new camera channel in a multi-unit
    connection. 
    The output type is a low-active open collector with a capacity of 16 V DC, 100 mA maximum.
    Pins #6 to #9 are used in many ways depending on the menu settings and the internal connector settings. If internal adjust-
    ments are required, please refer to the Service Manual available for this unit.
    Unit address 
    given to WJ-MP204CUNIT Switch Position
    1
    1 0Set the
    number in
    Setup
    menu
    9
    Do not 
    use,
    reserved
    2
    23
    34
    45
    56
    67
    78
    8
    1
    2
    3
    4 Connector 
    CAMERA IN/OUTUNIT Switch Position
    8 7 6 5 4 3 2 1
    1
    2
    3
    4 0Set the
    number in
    Setup
    menu5
    6
    7
    89
    10
    11
    1213
    14
    15
    1617
    18
    19
    2021
    22
    23
    2425
    26
    27
    2829
    30
    31
    329
    Do not 
    use,
    reserved
    ALARM / REMOTE
    GND GND
    9876 54321 
    						
    							17
    8Alarm input 
    Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in the setup, and the internal connector remains in
    the default position (CN703, ALM IN): 
    Pin #6 accepts CH 1 alarm input from the connected sensor.
    Pin #7 accepts CH 2 alarm input from the connected sensor.
    Pin #8 accepts CH 3 alarm input from the connected sensor.
    Pin #9 accepts CH 4 alarm input from the connected sensor.
    8Alarm output
    Available when TERMINAL is set to ALARM and TERM. ALARM is set to ON in the setup, and the internal connector is
    changed to CN702 (ALM OUT): 
    Pin #6 supplies CH 1 alarm output when the connected camera detects video motion (VMD) in the image. 
    Pin #7 supplies CH 2 alarm output as above.
    Pin #8 supplies CH 3 alarm output as above.
    Pin #9 supplies CH 4 alarm output as above.
    8Spot switching input
    Available when TERMINAL is set to REMOTE in the setup, and the internal connector remains in the default position (CN703,
    ALM IN):
    Pin #6 accepts the switching signal that changes the spot output image to CH 1.
    Pin #7 accepts the signal to switch image to CH 2.
    Pin #8 accepts the signal to switch image to CH 3.
    Pin #9 accepts the signal to switch image to CH 4.
    8Spot switching output
    Available when TERMINAL is set to REMOTE in the setup, and the internal connector is changed to CN702 (ALM OUT):
    Pin #6 supplies a tally output while CH 1 is selected.
    Pin #7 supplies a tally output while CH 2 is selected.
    Pin #8 supplies a tally output while CH 3 is selected.
    Pin #9 supplies a tally output while CH 4 is selected.
    Internal Setting
    The following functions can be set with internal connectors and switches when you need to change default settings marked
    with *. Refer to the Service Manual for internal settings.
    • ALARM/REMOTE terminal definition (In*/Out) ............... CN702, CN703
    • Alarm reset signal input (0V-5V*/O.C) ........................................ SW704
    • Setup menu to CAM OUT (ON*/OFF) ......................................... SW702
    RS-485 DATA Port Connection (PS•Data)
    Data ports are connected with RS-485 cables among devices using PS•Data protocol as follows.
    •Internal Diagram
    1
    6
    1
    6
    No.No.NameData Flow
    11GND–
    22RX(B)WJ-MP204C ← WV-CU360C
    33RX(A)WJ-MP204C ← WV-CU360C
    44TX(B)WJ-MP204C → WV-CU360C
    55TX(A)WJ-MP204C → WV-CU360C
    66GND–
    Controller endRX (A)
    TX (B) 
    TX (A)
    RX (B) 
    						
    							18
    •Basic Connection
    •Daisy Connection
    RS-485 Terminal Connection (Camera
    Communication)
    These terminals are connected with system devices using
    the Camera Communication Protocol in 4-line full duplex or
    2-line half duplex mode specified with the DIP switch set-
    ting.
    Notes:
    • Use a data grade, shielded and twisted cable suited to
    RS-485. The maximum allowable cable length is 4 000
    ft (1 200m).
    • Termination should be made at both ends of the data
    line, while being open at intermediate devices.
    8Internal Diagram84-line Full Duplex
    82-line Half Duplex
    D ATA
    Data Multiplex Unit
    WJ-MP204CSystem Controller
    WV-CU360C
    D ATA
    RS-485 Cable
    Termination:
    ONTermination:
    ON
    D ATA
    Data Multiplex Unit
    WJ-MP204C
    Branch
    Cable Termination:
    OFF Termination:
    ONSystem Controller
    WV-CU360C
    D ATA  D ATA
    Video Multiplexer
    WJ-FS309 (WJ-FS316)
    RS-485
    CableTermination:
    ON
    RS-485
    Cable
    RA  TB  4
    3
    2
    1
    TA 
    RB 
    WJ-MP204C
    SYSTEM
    UNITR TA B A B G
    R TA B A B G
    RS485 RS485
    Termination ON
    (at the end position)
    Camera communication modeMODE
    4-Line
    (Full duplex)
    SYSTEM
    UNITWJ-MP204C
    RS485
    R TA B A B G
    R TA B A B G
     Termination ON 
     (at the end position)
    Camera communication modeMODE
    2-Line
    (Half duplex)
    RS485 
    						
    							19
    Prior to setup
    Confirmation
    1. Connections and switch settings are complete.
    2. Switch on the power of the connected system devices
    including the monitor that displays the menus.
    3. Turn on the power of the WJ-MP204C. 
    4. When setting at the camera site, remove the front cover
    from the unit to make access possible to the buttons on
    the front panel.
    5. When setting with use of a WV-CU360C System
    Controller, confirm that the OPERATE indicator is lit on
    the Controller, meaning that the unit is ready for opera-
    tion. 
    To open or close the setup menu 
    1. Hold down the SETUP/ESC button on the front panel for
    2 seconds. Image display will change to the menu win-
    dow on the monitor, or vice versa. 
    2. When using a WV-CU360C, hold down the SETUP but-
    ton on the controller for 2 seconds. The setup menu will
    open or close.On the window, you can select and enter the parameter
    using buttons. A sub menu will open when a line having
    a [return  ] mark at its end is selected. 
    Buttons used in the setup
    The following buttons are used in the setup. Operations on
    the following pages are explained on the assumption that
    the front panel buttons on the WJ-MP204C are used. Check
    below which WJ-MP204C front panel buttons are equivalent
    to the buttons on the WV-CU360C.
    •Data Multiplex Unit WJ-MP204C
    [C] button:Moves the cursor downward.
    [D]:Moves the cursor upward.
    [–]:Decreases the parameter value.
    [+]:Increases the parameter value.
    [SET]:Validates the selected parameter, or opens a
    sub menu when [ ] appears.
    [ESC]:Returns the menu to a higher layer.
    •System Controller WV-CU360C
    SETUP PROCEDURES
    WJ-MP204C SETUP MENUX.XX
       COMMUNICATION
       SYSTEM
    OPERATELOGIN ALARM
    CAM SETUPPROGRAM
    PROGRAM
    PRESET
    UNIT AIRIS
    CLOSE OPEN
    NEAR FAR
    WIDE TELE
    FOCUS
    ZOOM AUTO FOCUSIRIS RESET
    AUTO SETUPALM SUSPENDFUNCTIONCAM FUNCTION
    MULTI SCREEN SELECTDEF
    WIPER
    EL-ZOOM
    SHIFTALM RESET
    VCR   CAM
    STILL
    –
    +
    ALM RECALL
    PATROL
    LEARN PATROL
    STOP
    AUX 1
    AUX 2
    B/WUNIT
    SEQ PAUSE
    SLOWSEQUENCEPATROL PLAYHOME/PRESET
    UNIT B
    MONCAM
    LOGOUT
    ESC SET
    UP
    LR
    DOWN
    BUSY PROHIBITEDMONITOR
    UNITCAMERASystem ControllerWV-CU360C
    ALARM
    Data Multiplex Unit WJ-MP204C
    ALARM
    SUSPEND
    12 34ESC SET RESET
    SUSPEND SET UPALARM UNIT 0987654321
    :  Moves the cursor up and down.
    :  Increases or decreases the parame-
    ter value.
    :  Validates the selected parameter, or
    opens a sub menu when [ ]
    appears.
    :  Returns the menu to a higher layer.
    DOWN LR
    UP
    LR
    STILL
    –
    EL-ZOOM
      +
    MON
    CAM
    ESCSET 
    						
    							20
    Setup menus
    There are two setup menu groups depending on the communication protocol used in the system, menus for PS•Data and for
    the Camera Communication Protocol.  MODE DIP switch # 3 on the rear of the unit is set to the position of the used protocol,
    and it specifies what menu group is displayed on the monitor. Menu trees are shown below for two protocols. 
    COMMUNICATION
    UNIT ADDRESS
    BAUD RATE
    DATA BIT
    PARITY CHECK
    STOP BIT
    WAIT TIME 
    SYSTEM
    ALARM MODE
    MONITOR SPOT
                                                                    MONITOR SPOT
    ALARM DISPLAY
    SITE ALARM
    TERM. ALARM
    ALARM OUTPUT
    ALARM DATA
    COMP/VD2/DATA
    CAMERA IN
    COMP
    VD2
    D ATA
    VS/VD INPUT
    CAMERA CONFIG
    CAMERA CONFIG
    DAISY MODE
    TERMINAL
     Setup menus for PS•Data
    COMMUNICATION
    CAM ADDRESS
    CAM ADDRESS
    BAUD RATE
    DATA BIT
    PARITY CHECK
    STOP BIT
    WAIT TIME 
    DELAY TIME 
    XON/XOFF 
    SYSTEM
    ALARM MODE
    MONITOR SPOT
    ALARM DISPLAY
    SITE ALARM
    TERM. ALARM
    ALARM OUTPUT
    ALARM DATA
    COMP/VD2/DATA
    CAMERA IN
    COMP
    VD2
    D ATA
    VS/VD INPUT
    DAISY MODE
    TERMINAL
     Setup menus for Camera Communication 
        Protocol 
    						
    All Panasonic manuals Comments (0)