Page 21
21 Setup Menus for PS•Data Communication setup (PS•Data) Communication parameters for a PS•Data protocol system are set in this menu. 1. Hold down the SETUP button for 2 seconds to open the setup menu. 2. Move the cursor to COMMUNICATION , then press SET. The communication setup appears. 8UNIT ADDRESS 1. Move the cursor to UNIT ADDRESS, then specify a number with the [–] or [+] button. The default setting is 1. Available numbers:1-99 Note:This setting takes effect only when the UNIT switch is set to 0...
Page 22
22 8Alarm mode setup 1. Move the cursor to ALARM MODE to select ON or OFF with the [–] or [+] button, then press SET. The default setting is ON. ON :Opens a submenu shown below. OFF:Alarm mode is disabled. The ALARM MODE sub menu appears. 1-1. Move the cursor to MONITOR SPOT to select ON or OFF with the [–] or [+] button, then press SET. The default setting is ON . This setting specifies whether to change the monitor image when an alarm operates. ON :Image display on the monitor changes to that of the...
Page 23
23 8Cable compensation/VD2 sync/data setup The COMP/VD2/DATA menu is displayed when you select it in the SYSTEM menu. In this menu, each camera is set up for cable compensa- tion, VD2 sync and data communication ON/OFF. 1. Move the cursor to CAMERA IN. Select a camera input channel with the [–] or [+] button. The default setting is 1CH. The camera channel to be set up is selected and the image of the channel is displayed in the background of the setup menu. Available channels:1CH, 2CH, 3CH, 4CH 2. Move...
Page 24
24 8Camera Configuration The CAMERA CONFIG menu is displayed when you select it in the SYSTEM menu. When more than one unit are used, each camera input is given a camera number in this menu. 1. Move the cursor to CAM NO. Select a number with the [–] or [+] button. The default setting is that both CAM- ERA IN and CAM NO. are given the same number. Available numbers:1-128 and – (not connected) 2. Repeat the above step until all CAMERA IN are assigned numbers. 3. Press ESC to return to the SYSTEM menu....
Page 25
25 8CAM ADDRESS Camera addresses are assigned to each of the units cam- era input. 1. Move the cursor to CAM ADDRESS , then press SET. The CAM ADDRESS window appears. 2. Specify a number with the [–] or [+] button. The default setting is 1. Available numbers:1-99, – (no assignment) Note:This setting takes effect only when the UNIT switch is set to 0 on the front panel. 3. Repeat the above step until all camera inputs are given addresses. 4. Press ESC to return to the communication setup. 8BAUD RATE 1....
Page 26
26 The ALARM MODE sub menu appears. 1. Move the cursor to MONITOR SPOT to select ON or OFF with the [–] or [+] button. The default setting is ON. This setting specifies whether to change the monitoring image when an alarm operates. ON:The image displayed on the monitor screen changes to that of the alarm activated channel. OFF:The image displayed will not change even when an alarm operates. 2. Move the cursor to ALARM DISPLAY. Select ON or OFF with the [–] or [+] button. The default setting is ON. Alarm...
Page 27
27 2. Move the cursor to COMP. Select a parameter with the [–] or [+] button. The default setting is S. The longer a coaxial cable is extended, the more the video signals attenuate. This setting is to compensate signal attenuation in 3 degrees. Select the best para- meter that optimizes the displayed image on the moni- tor while observing it. S:Short distance of less than 1 300 ft (400 m) M:Medium distance between 1 300 ft (400 m) and 2 300 ft (700 m) L:Long distance of less than 3 000 ft (900 m)...
Page 28
28 Camera selection and alarm operations are made on the front panel of the unit or WV-CU360C System Controller. Camera Selection Front Panel Operation • You need to remove the front cover loosening the screw with a screw driver before starting operation. • Press a camera number button. The selected camera picture is displayed on the moni- tor connected to the SPOT OUT terminal on the rear of the unit. WV-CU360C Operation • Enter a camera number with numeric buttons, then press the CAM/SET button....
Page 29
29 WJ-MP204CFunctionWV-CU360C Camera Selection Alarm Reset Alarms are reset according to the reset mode (EXT, auto (1S-5M) or OFF) selected in the ALARM OUTPUT setup. •Manual resetting Pressing the RESET button on the unit resets the activated alarm. Pressing the ALARM RESET button on the controller resets the activated alarm. •External resetting Input to the ALARM/REMOTE terminal resets the activated alarm when the terminal is set to the alarm input mode. •Auto resetting Elapsing of the preset time...
Page 30
30 SPECIFICATIONS Power Source : 120 V AC 60 Hz Power Consumption : 7 W Camera Input : 1 V[p-p]/75 Ω x 4 Spot Input : 1 V[p-p]/75 Ω x 1 VS/VD Input : VS (1 V[p-p]/75 Ω), or VD (4 V[p-p]/75 Ω) x1 Camera Output : 1 V[p-p]/75 Ω(Looped through) x4 Spot Output : 1 V[p-p]/75 Ωx1 (Changeable Output from camera input or Spot input) VS/VD Output : VS/VD IN (Looped through), or internal VD (4 V[p-p]/75 Ω) x 1 Data Communication Standard : Based on RS-485 (4-Line/2-Line* 1) Modular Jack x 1, or 5-pin terminal x...