Page 11
About 12.7mm (1/2) 76.2cm (30)~ 152.4cm (60) Awning Cooled airFence Over 50.8cm (20) Heat radiation 55.8cm (22) to 91.44cm (36) Offset12.7mm (1/2) to 31.8mm (11/4) Sill Exterior Interior wall 47cm (181/2) min.(Without frame curtain) Stool38cm (15) min (With frame curtain) 11 INSTALLATION Features and Installation 1. To prevent vibration and noise, make sure the unit is installed securely and firmly 2. Install the unit where the sunlight does not shine directly on the unit. 3. The outside of the cabinet...
Page 12
9 10 9 5 5 5 11 11 (Type A) (Type A) 13 1234 813 14 10 765 9 12 11 Shipping Screws PREPARATION OF CHASSIS 1. Remove the screws which fasten the cabinet at both sides and at the back. 2. Slide the unit from the cabinet by gripping the base pan handle and pulling while bracing the cabinet. 3. Cut the window sash seal to the proper length. Peel off the backing and attach the FOAM-PE to the underside of the window sash. 4. Remove the backing from the top upper guide FOAM-PE and attach it to the bottom of...
Page 13
13 Features and Installation Upper Guide Window SashWindow sill Front Angle Upper guide 9 Frame Curtain1 Foam-pe10 Foam-pe13 Cabinet INDOOR OUTDOOR INDOOR OUTDOOR Sash track Front AngleCabinet About 12.7mm ( 1/2) About 12.7mm ( 1/2) Sill Support2 Nut4Bolt3 Frame Guide11 Screw (Type B)6 Screw (Type B)6 Sill support2 Sill support2 Screw (Type A)5 1. Open the window. Mark a line on center of the window sill (or desired air conditioner location). Carefully place the cabinet on the window sill and align the...
Page 14
Type C7 Screw (Type A) Screw (Type A)Power cord Foam-Strip8 Window locking bracket12 14 Features and Installation 9. Attach each Frame curtain to the window sash using screws (Type C). (See Fig. 6) CAUTION: DO NOT DRILL A HOLE IN THE BOTTOM PAN. The unit is designed to operate with approximately 12.7mm ( 1/2) of water in bottom pan. 10. Slide the unit into the cabinet. (See Fig. 7) CAUTION: For security purposes, reinstall screws (Type A) at cabinets sides. 11. Cut the foam-strip to the proper length...
Page 15
15 Features and Installation Do not under any circumstances cut or remove the grounding prong from the plug. Line Cord Plug Use Wall Receptacle Power Supply Power supply cord with 3-prong grounding plugStandard 125V, 3-wire grounding receptacle rated 15A, 125V ACUse 15 AMP, time delay fuse or circuit breaker. Electrical Data USE OF EXTENSION CORDSBecause of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA...
Page 16
PREFERRED METHOD Ensure proper ground exists before use TEMPORARY METHOD Adapter plug Receptacle coverMetal screw 16 Electrical Safety (Applies to USA only) Features and Installation IMPORTANT (PLEASE READ CAREFULLY) FOR THE USERS PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with a standard three-slot (grounding) wall power outlet (Fig. 16) to minimize the hazard of electric shock. The customer should...
Page 17
17 Before you call for service... Before you call for service... Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service. Problem Possible Causes What To Do The air conditioner is unplugged. The fuse is blown/circuit breaker is tripped. Power failure. Airflow is restricted. The THERMOSTAT may not be set high enough. The air filter is dirty. The room may have been hot. Cold air is escaping. Cooling coils have iced up. Ice blocks...
Page 18
18 Instructions de fonctionnement Instructions dinstallation Conseils de dépannage Mesures de sécurité Mesures de sécurité Mesures de sécurité ........19 Instructions de fonctionnement Les commandes... .............21 Télécommande..................22 La ventilation .....................24 Ajuster la direction d’air .....24 Comment utiliser le tuyau d’évacuation ......................24 Nettoyage et entretien Nettoyage du filtre à air... ..25 Caractéristiques Caractéristiques ................26...
Page 19
Mesures de sécurité AVERTISSEMENT 19 Mesures de sécurité Les instructions ci-après doivent être observées dans le but de prévenir tout risque de dommages corporels ou matériels. Lutilisation non conforme, résultant de la négligence des instructions, est susceptible de provoquer des dommages corporels ou matériels dont la gravité est signalée par les indications suivantes : AVERTISSEMENT: Ce symbole signale un risque de blessure grave, voire mortelle. ATTENTION: Ce symbole signale un risque limité aux...
Page 20
20 Mesures de sécurité ATTENTION! Lorsque le filtre à air doit être retiré, ne pas toucher les parties métaliques de lappareil intérieur. • Vous risquez de vous blesser. Ne pas nettoyer le climatiseur à grande eau. • Leau peut sinfiltrer dans lappareil et affecter lisolement. Cela peut également provoquer une électrocution. Assurer une ample circulation dair dans la pièce si un appareil de chauffage est utilisé. • En effet, loxygène sappauvrit dans ces conditions dutilisation. Lorsque lappareil doit...