Panasonic Cw Xc71ya Cw Xc91ya Repair Manual
Have a look at the manual Panasonic Cw Xc71ya Cw Xc91ya Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
8.5. Fan Speed Control • • • • Manual Fan Speed Control Basic fan speed adjustment (2 setting, from Lo to Hi) can be carried out by using the Fan Speed Selection Button/Pad at the Remote Control or Main Unit (Touch Control Panel). 8.6. Airflow Direction Control 8.6.1. Horizontal Airflow Direction When AirSwing Button/Pad is pressed with Remote Control or Main Unit (Touch Control Panel) in the Auto Airflow, the airflow direction louver swings side to side within the full swing range as shown in the “Diagram”. The louver can be adjusted by pressing the Button/Pad again at the Remote Control or Main Unit (Touch Control Panel) to the desired louver position . Whenstopped with Remote Control or Main Unit (Touch Control Panel), the louver vane is reset, and stopped at the closing position . “Diagram” 8.6.2. Vertical Airflow Direction • • • • The upward and downward airflow direction vane can be adjusted manually by hand. 8.7. Remote Control Signal Receiving Sound • • • • To switch off the beep sound. Press the “Operation OFF/ON Button/Pad“continuou sly for 10 second or more. Repeat the above if you want to switch ON the beep sound or switch OFF and ON back the Power Switch at the Main Unit. *However, if the “Operation OFF/ON Button/Pad” have been pressed, the previous operation mode will be activated. If you do not require this operation, you may change it by using the Remote Control or Main Unit (Touch Control Panel). 11 CW-XC71YA / CW-XC91YA
9.1. Parts Identification. 9.1.1.1. Vertical Airflow Direction Vane. Airflow direction adjustment Up-and-Down. • • • • The vertical airflow direction vane may be positioned to deflect the air upward, downward or straight on. 9.1.1.2. Ventilation Lever. When theslide lever is in the: • • • • “OPEN” position, the ventilation door opens to allow air, smoke and odors to be expelled from the room. • • • • “CLOSE” position, the ventilation door is closed and the air inside the room is circulated and conditioned. 9 Operating Instructions 9.1.1. Main Unit. 9.1.1.3. Touch Control Panel. 9.1.1.4. Types of Signal Sound. • • • • One long “Beep” and one short “Beep” (Sound from the main unit). 12 CW-XC71YA / CW-XC91YA
Ensure that the power plug is securely inserted. • • • • A loose plug may cause a fire or an electric shock. (1) Insert the power plug securely. 9.2.2. Operating Conditions. Use the air conditio ner under the followin g conditio ns: • • • • Operating temperature range. Indoor sideIndoor sideOutdoor sideOutdoor side D.B.T.W.B.T.D.B.T.W.B.T. Maximum Temperature32°C23°C43°C26°C Minimum Temperature16°C11°C16°C11°C D.B.T.: Dry Bulb Temperature W.B.T.: Wet Bulb Temperature Note: Humidity may exceed 90%. − − − − Continuous operation at over 90% high humidity may create condensation and result in water drops on the intake and outlet vanes. 9.2.3. Notes • • • • If the unit is not going to be used for an extended period of time, turn off the power switch. if it is left in the ON position , approximately2.5W ofelectricity will be used even if the Main Unit has been turned off by the remote control. • • • • If operation is stopped, and to be restarted immediately, the unit will resume operationonly after 3 minutes. Be sure to observe the following: • • • • Aim at the signal receptor at the room air conditioner when operating. • • • • Do not drop or throw the remote control. • • • • Do not place the remote control in a location that is exposed to direct sunlight or next to a heating unit or other heat sources. 9.2.4. How to Insert Batteries. (1) Open the compartment cover. (2) Be sure that the polaritie s are correct. (3) Close the compartment cover. 9.2.5. About theBatteries. • • • • The batteries can be used for approximately one year. • • • • Do not use rechargeable (Ni-Cd) batteries because such batteries differ from the standard drycell batteries in shape, dimension and performance. • • • • Be sure to replace the batteries with two new identica l batteries. • • • • Remove the batteries if the air conditio ner is not going to be used for an extended period of time. 9.1.2. Remote Control. 9.2. Preparation Before Operating. 9.2.1. Before Operate the Air Conditioner. 13 CW-XC71YA / CW-XC91YA
9.3. Air Conditioner Operation. 9.3.1. Operating the Unit. Touch Control PanelRemote ControlDisplay (1) Start operation by pressing OFF/ON. • • • • The operation will turn on and the display panel will light up. (2) To stop the operation, press the OFF/ON again. • • • • The unit will stop operating and the display panel light will turn off. 9.3.2. Adjusting Operation Mode. Touch Control PanelRemote ControlIndicator (1) Press MODE to select the desired operation. • • • • The indicator will light up and a “beep” sound will indicate changing setting. − − − − COOL mode: To set room temperature to your preference of cooling comfort. − − − − FAN mode: To provide air circulation without cooling the room. During Fan operation, temperature setting cannot be selected. 9.3.3. Setting Display Temperature. Touch Control PanelRemote ControlDisplay (1) Press TEMP/TIME R “Upward” or “Downward” to set the room temperature. • • • • The temperature can be set between 16°C and 30°C. Recommended temperature: 26°C ~ 28°C. − − − − “Upward”: Press to increase temperature by 1°C. − − − − “Downward”: Press to decrease temperature by 1°C. Note: The latest temperature setting will be memorized and will appear on the display the next time it’s turned on. The display temperature selection is for display purpose only and does not indicates actual room setting temperatures. Your room temperature may not necessarily match the displayed temperature. 9.3.4. Selecting Fan Speed. Touch Control PanelRemote ControlIndicator (1) Press FAN SPEED to choose the speed level of the fan. • • • • The indicator will light up and the “beep” sound will indicate changing setting. Note: The latest fan speed setting will be memorized and the indicator will light up the next time the unit is turned on. 14 CW-XC71YA / CW-XC91YA
9.3.5. Adjusting Horizontal Airflow Direction. Touch Control PanelRemote ControlIndicator No indication will appear.(1) Press to select AIR SWING. • • • • The air circulation will automatically move the horizontal louvers left and right for better air distribution around the room. Note: Using your hands to adjust the direction may cause the louvers to malfunction. If this happens, stop operation immediately and restart. 9.3.6. POWERFUL Operation. Touch Control PanelRemote ControlDisplay (1) To obtain set temperature quickly: • • • • Press POWERFUL. • • • • To cancel this operation, press once more. • • • • After POWERFUL is selected, the operation will go on for 15 minutes under Super High Fan Speed, after that it will shift back to previous operation mode. • • • • W hen the POWERFUL is set during Cooling Operation, the set temperature will be automatically decreased 3°C against the present setting temperature (Lowest limit temperature:16°C). Note: Sound emitted by the unit will be increased during POWERFUL operation due to increased of air volume. 9.3.7. Setting Delay Stop TIMER. Touch Control PanelRemote ControlDisplay (1) Press the TIMER button. • • • • The SET/CANCEL indicator light will blink, indicating an entry is required. (2) Press the TEMP/TIME R “Upward” or “Downward” button. • • • • Press “Upward” or “Downward” button until the preferred hour of operation is reached. (3) Press the SET/CANCEL button to complete the setting. • • • • At this time, the SET/CANCEL indicator light willstay “on” instead of blinking. Note: The hour reading will change back to the set temperature reading after 10 seconds (You can also revert to temperature setting immediately by pressing the TEMP/TIME R “Upward” or “Downward” button again). 9.3.7.1. Timer Details. • • • • The timer is fordelay stop only. • • • • The unit will turn off automatically according to your specified setting. • • • • Timer duration can be set from a minimum of 1 hour to a maximum of 12 hours. • • • • W hen power failure occurs, the timer setting is cancelled. Once power is resumed, reset the timer. Note: The last timer settingwill bememorized and will appear on the display the nexttime you operate the unit with the Timer function . 15 CW-XC71YA / CW-XC91YA
9.3.8. Check TIMER setting. Touch Control PanelRemote ControlDisplay (1) Press the TIMER button to check the timer. • • • • The figure will be displayed for 10 seconds then will automatically switch back to temperature setting. Note: The timer figure will change according to the time remaining (if you set it to turn off 3 hours from now, the timer will show “2” when you check the timer an hour later). 9.3.9. Cancel TIMER. Touch Control PanelRemote ControlDisplay (Cancellation within 10 seconds) (1) Press the SET/CANCEL button to cancel the timer setting. • • • • The temperature reading and SET/CANCEL indicator light will turn off simultaneously. Figures will be displayed again 10 seconds later to show the temperature (or, press the TEMP/TIME R “Upward” or “Downward” button to have the temperature reading immediately). (Cancellation after 10 seconds) (1) Press the SET/CANCEL button to cancel the timer setting. • • • • The SET/CANCEL indicator light will turn off. However the temperature remains displayed. 16 CW-XC71YA / CW-XC91YA
10.1.1. Electrical Work. • • • • Always use at the rated voltage and with a specific air conditio ning circuit. • • • • Some installation location s may require installation of a short-circuit breaker. • • • • A 16 Ampere timedelay fuse or circuit breaker is required. • • • • Nominal cross sectional area of power supply wire must be 3 core x 1.5 mm 2or above. • • • • Power supplymust be from an indepe ndent circuit. • • • • All electrical installation must be made in accordance with local wiring and safety regulations wherever applica ble. • • • • There must be a double pole switch with minimum of 3 mm contact gap in the fixed installation circuit (Applicable for models without power supply plug only). • • • • Please consult your dealer concerning installation requirements. 10.1.2. Select the Best Location. • • • • Install the unit at the nearest power outlet. • • • • Power supply point shall be the place where there is ease for the power disconn ection in case of emergency. • • • • The air conditio ner should be installed in a dry place where there are no draughts. • • • • Condensation from the air conditio ner must be drained into an appropriate location . • • • • Do not install in a location where flammable gas leaks is a possibility. • • • • Usage in location s where the air is salty such as coastal areas or near hot spas, or where sulphurous gas is generated, may lead to a malfun ction of the unit. Please consult your dealer. • • • • Select an installation location which is rigid and strong enough to support or hold the unit and select a location for easy maintenance. 10 How To Install 10.1. Before installing air conditioner, please read the following: 10.2. Preparation before Installation. • • • • There should not be any obstacles surrounding the unit. • • • • Prepare an installation hole that is only slightly bigger than the cabinet size. • • • • Left and right side of the unit should be at least 150 mm awayfrom the wall. 17 CW-XC71YA / CW-XC91YA
10.3.1. Remove the Front Intake Grille. 1. Push on the indication. Front Intake Grille will be automatically released. 2. Pull up the Front Intake Grille about 90° and slide it slightly to the left to unhook the tabs. 10.3.2. Remove the Air Filter. • • • • Tilt up and pull out the air filter by the holder. 10.3.3. Remove the Front Grille. 1. Remove the adhesive tapes from all sides of the Front Grille. 2. At the bottom right side of the Front Grille, press inward on the Cabine t near the Power Cord and pull the grille outward to the right until the right tab releases. 3. At the bottom left side, push inward on the Cabine t and pull the grille outward to the left to release the left tab. Do not pull the bottom edge toward you more than 3 inches as to prevent top two tabs from damage. 4. Slide the Front Grille upward to free the two top tabsfrom slots at the top of the Cabine t. 10.3.4. Remove the Chassis from the Cabinet. 1. Unscrew and remove the Chassis Locking Bracket. 2. Unscrew and remove from rearCabine t. 10.3.5. Slide the Chassis out from the Cabinet. 10.3. Installation Procedure. 18 CW-XC71YA / CW-XC91YA
10.3.6. Place Cabinet into the installation hole, then secure it by wood screws or nails. 10.3.7. Slide the Chassis back into the Cabinet. 10.3.8. Lock the Chassis back to the Cabinet by reusing back the Chassis Locking Brackets. 10.3.9. Reattach the Front Grille to the Cabinet and secure it with screws. • • • • Note: Depend ing upon the location of the AC outlet, route the AC cord to either the left or right side while installin g the Front Grille. 10.3.10. Insert the Air Filter. 10.3.11. Reattach the Front Intake Grille. • • • • Slide the Front Intake Grille slightly to the right to reattach the tabs and then push down to close tight. Note: A ”Click” sound can be heard when the Front Intake Grille is pushed down. 19 CW-XC71YA / CW-XC91YA
10.4. Condensed Water Drainage. This air conditio ner employ s a “Slinger-Up System” which is designe d to splash the condensed water on the condenser coil for maximum cooling efficiency, thus producing a splashing sound. However, due to the humidity variance and drainage possibilities in the area, customer can choose these drainage options. (1) At ex-factory conditio n, a rubber drain cap with hole has been attached. This will allow condensed water to be formed up till a certain level for the “Slinger-Up System” and the excess to be drained out. Install a drain pan for drainage. This setting will cause some splashing sound. (2) However if circumstances are not suitable for drainage, customers may use the supplie d rubber drain cap without hole. This will however cause a louder splashing sound but better cooling efficiency as to the “Slinger-Up System”. • • • • Drain cap without hole is packed together with Operating Instruction bag complete. (3) If customer do not want any splashing sound at all and if circumstances permit drainage, remove the drain cap in order for the condensed water to be drained out totally. Install a drain pan for drainage. However, this will cause a small loss of performance. 10.5. Drain Pan Installation and Drain Hose Connection. (1) Install the Drain Pan at the right corner of the Cabine t with 2 screws. (2) Connec t the drain hose to the outlet of Drain Pan bottom. 20 CW-XC71YA / CW-XC91YA