Panasonic Cw Xc71ya Cw Xc91ya Repair Manual
Here you can view all the pages of manual Panasonic Cw Xc71ya Cw Xc91ya Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
ModelCW -XC71YACW -XC91YA PhaseSingleSingle Voltage220 V220 V Frequency50 Hz50 Hz Cooling Capacity2.06 kW 7,000 Btu/h2.64 kW 9,000 Btu/h Running Current3.1 A4.1 A Input Power650 W880 W EER3.17 W/W3.00 W/W Starting Current11 A18 A Compressor Output550 W750 W Noise LevelIndoor (High / Low): 45 dB(A) / 35 dB(A) Outdoor (High / Low): 55 dB(A) / 50 dB(A)Indoor (High / Low): 45 dB(A) / 37 dB(A) Outdoor (High / Low): 56 dB(A) / 53 dB(A) Moisture Removal1.3 Ltr/h 2.7 Pint/h1.6 Ltr/h 3.4 Pint/h © 2001 Matsushita...
Page 2
1 Functions 2 2 Dimensions 4 3 Refrigeration Cycle Diagram 5 4 Block Diagram 5 5 Wiring Diagram 6 6 Air Conditioner Performance Evaluation 7 7 Troubleshooting Guide 8 8 Operation Details 9 9 Operating Instructions 12 10 How To Install 17 11 Care and Maintenance 21 12 Service Information 22 13 Exploded View 23 14 Replacement Part List 24 15 Electronic Circuit / Indicator Complete 25 16 Electronic Circuit / Main 25 17 Technical Data 26 18 Electronic Circuit...
Page 4
2 Dimensions 2.1. CW-XC71YA CW-XC91YA 2.1.1. Top View, Front View and Side View. ItemUnit: Inch (mm) A - Width17-23/32” (450) B - Height13-5/8” (346) C - Depth22-27/32” (580) D21-1/4” (540) E5-21/32” (144) F6-1/32” (153) G1-31/32” (50) H3-27/32” (98) I1-3/16” (30) J3-27/32” (98) K1-9/16” (40) L9-7/32” (234) M3-27/32” (98) N2-31/32” (75) O1-11/16” (43) P3-17/32” (90) Q0-29/32” (23) R10-11/32” (263) 4 CW-XC71YA / CW-XC91YA
Page 5
3.1. CW-XC71YA CW-XC91YA3.2. CW-XC71YA ItemPressure (MPa)Temperature (°C) A1.91 ~ 2.1170 ~ 85 B1.86 ~ 2.0635 ~ 45 C0.60 ~ 0.668~14 D0.57 ~ 0.6310 ~ 18 Note: Indoor temperature at 27°C (DB), 19°C(WB) andOutdoor at 35°C (DB), 24°C(WB). 3.3. CW-XC91YA ItemPressure (MPa)Temperature (°C) A2.00 ~ 2.2072 ~ 87 B1.95 ~ 2.1535 ~ 45 C0.54 ~ 0.607~13 D0.51 ~ 0.579~17 Note: Indoor temperature at 27°C (DB), 19°C(WB) andOutdoor at 35°C (DB), 24°C(WB). 3 Refrigeration Cycle Diagram 4 Block Diagram 4.1. CW-XC71YA...
Page 6
5.2. Resistance of Fan Motor windings and the rated Capacitor. ModelCW-XC71YACW-XC91YA ConnectionCWA921085CWA921085 Blue - Yellow76.6Ω76.6Ω Yellow - Brown19.2Ω19.2Ω Brown - Orange133.3Ω133.3Ω Red - Yellow119.1Ω119.1Ω 5.3. Resistance of Compressor windings and the rated Capacitor. ModelCW-XC71YACW-XC91YA Connection2RS122D5AA042PS156D5CA02 C-R4.023Ω3.501Ω C-S8.803Ω3.405Ω CapacitorCWA312074 (15µF, 400VAC)DS371306CPNA (30µF, 370VAC) Note: Resistance at 20°C of Ambient Temperature. 5 Wiring Diagram 5.1....
Page 7
6 Air Conditioner Performance Evaluation Suction & Discharge Air Temperature DifferenceCurrentDeterminationRemedy • • • • 8°C and over (14.4°F) • • • • As specified. • • • • Nothing wrong. • • • • None. • • • • 8°C and over (14.4°F) • • • • Higher than specified. • • • • Nothing wrong, outdoor temperature is too high, heat radiation is not efficient. • • • • Improve heat radiation. • • • • Under 8°C (14.4°F) • • • • Higher than...
Page 8
7 Troubleshooting Guide Warning: Disconnect unit from electrical powersupply before making any electrical checks. TroubleCheckResultCauseRemedy Fan Motor and Compressor won’t run. • • • • Supply Voltage • • • • Fuse Box or Circuit Breaker. • • • • Power cord orWiring Harness. • • • • Temp. Setting. • • • • Less than 10% by Rated. • • • • Open Contacts. • • • • Pulled loose or Shorted. • • • • Higher than ROOM TEMP. • • • • Customer...
Page 9
8 Operation Details 8.1. Fan Mode Operation • • • • Fan operation only. Fan in operation according to Remote Control or Main Unit (Touch Control Panel) setting. 8.1.1. Manual Setting of Fan Speed • • • • Basic Fan Speed can be manually adjusted (Lo or Hi) by using the Fan Speed Selection Button/Pad at Remote Control or Main Unit (Touch Control Panel). 8.2. Cooling Mode Operation • • • • Cooling in operation according to Remote Control or Main Unit (Touch Control Panel) setting....
Page 10
8.2.6. Cooling Operation Time Diagram 8.3. Powerful Operation • • • • Purpose of this operation is to obtain the setting temperature quickly. • • • • W hen the Powerful is set during Cooling Operation, the set temperature will be automatically decreased 3°C against the present setting temperature (Lowest limit temperature: 16°C). • • • • This operation automatically will be running under Super High Fan Speed. • • • • Sound emitted by the unit will be increased during...