Page 81

2. When defrosting is complete
 1. Start
Hot start control commences when defrosting is complete.
 2. Operation
PREHEAT appears on the remote controldisplay . (Other display s remain unchanged.)
At the indoor unit, the indoor unit fan stops. In additio n, during hot starting, the louvre stays at the horizon tal position (angle
0°).
 3. Cancelling
Hot starting is cancelled when the temperature detected by the indoor unit pipe temperature sensor is 18°C or higher, or
after a maximum 1 minute has passed...

Page 82

24.6. Excess heat dissipation for indoor unit
The indoor unit fan continues operating for 30 seconds after heating mode operation turns off in order to dissipa te excess heat.
 1. Whenheating mode operation has stopped
(LOWoperation for 30 seconds)
 2. Whenoperation is set to a mode other than heating by means of the OPERATION MODE switch
 3. If operation starts again during the 30 seconds mentioned in (1) above
(The fan operates at LOW speed for the remainder of the 30 seconds in (1), and then hot start...

Page 83

24.8. Indoor thermostat characteristic
 1. Thermostat characteristic during cooling and heating modes
83 

Page 84

84 

Page 85

85 

Page 86

24.9. Indoor unit fan control
 1. Fixing at LO, MED or HI
When LO, MED or HI isset, the relay switches and operation is carried out at that setting.
 2. Automatic fan speed
When set toAUTO, the indoor unit fan operation changes as shown in the table below.
24.10. Forced operation during restart
The compressor will not stop operating for 3 minutes after cooling mode or heating mode operation starts, even if the indoor unit
thermostat turns off. (However, the compressor will stop operating during this time...

Page 87

24.14. DIP switch settings
 
    • 
• •  • 
Indoor unit printed circuit board (DSW1)
87 

Page 88

25 INSTALLATION (INDOOR UNIT)
88 

Page 89

89 

Page 90

90 
Start reading Panasonic Cs W18bd3n Cs W24bd3n Cs W28bd3n Series Repair Manual