Panasonic Cs W18bd3n Cs W24bd3n Cs W28bd3n Series Repair Manual
Panasonic Cs W18bd3n Cs W24bd3n Cs W28bd3n Series Repair Manual
Here you can view all the pages of manual Panasonic Cs W18bd3n Cs W24bd3n Cs W28bd3n Series Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
1 SERVICE INFORMATION 2 2 FEATURES 3 3 SPECIFICATION (HEAT PUMP TYPE) 9 4 TECHNICAL DRAWING 15 5 CIRCUITDIAGRAM 23 6 OPERATING INSTRUCTION 34 7 REFRIGERATION CYCLE 36 8 OPERATIO N RANGE 38 9 PIPE LENGTH 39 10 OPERATING CHARACTERISTIC 41 11 FAN PERFORMANCE 42 12 SAFETYDEVICE 46 13 COMPONENT SPECIFICATION 47 14 CAPACITY AND POWERCONSUMPTION 49 © 2002 Matsushita Industrial Corporation Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a...
Page 2
1 SERVICE INFORMATION Caution: !Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). !Pb free solder will tend to splash when heated too high (about 1100° F/600°C). Notice of Address setting for NEW Hide-away / NEW Outdoor Unit. The new Hide-away / New Outdoor models are possible to have...
Page 3
2.1. Variety of excellent features 2.1.1. Compact design, height 27 cm • • • • The height has been reduced to 27 cm (for 2.5HP to 5.0HP), the equipment can be installe d in limited spaces. 2.1.2. Versatile installation • • • • The indoor unit is designed in order that air will also enter from below, for easier installa tion under different conditions. • • • • The equipment has two drain outlets on the right and left side for adoption to the installa tion conditions in the...
Page 4
[Product features] 2.2.1. Low-noise design improves in surrounding areas 1. The noise-suppressing winglet fan is a result of new research into vane design theory. The unique curved shape suppresses the generation of vortexes, thus reduces air flow noise. 2. The adoption of double -orifice rings reduces air passage resistance. 3. Strengthening of the noise insulation materials in the compressor and the sealing-in of mechanical noise allows vibration noise to be greatly enclosed and suppressed. 4. The...
Page 5
2.3.1. Additional refrigerant charging unnecessary for 30 m • • • • All models do not require any additio nal charging of refrigerant for 30 m of pipe length. This makes installa tion much easier. 2.3.2. Drain water dripping-prevention structure • • • • The base of the outdoo r unit is provided with a single drain hole in order to prevent drain water from leaking out of the unit. Body connecting a drain elbow and a discharge pipe, water leakages can be prevented even when the unit is...
Page 6
2.4.2. Separate indoor/outdoor unit power supplies The power supply can be connected to (1) just the outdoo r 2.4.5. Twin operation • • • • Simultaneous air conditioning of wide spaces and corners is possible. Indoor units of different horsepowers and models can even be used in combination. • • • • Master unit and slave-units can be set automatically in twin systems. No address setting is necessary. • • • • Multiple indoor units can be operated simultaneousl y with a single...
Page 7
2.5.2. Installation and precautions 2.5.2.1. Before installation 1. Determine the installa tion division. 2. Check the refrigerant to be used. • • • • Check that the refrigerant is R407C . • • • • Check that the gauge pressure is at a maximum of 3.3 MPa. 3. Make a drawing of the Installation. 2.5.2.2. Installation 1. Install the sleeve and the insert. 2. Install the indoor unit. 3. Install the refrigerant piping. • • • • Pipe materials (Phosphorus Deoxid ization Seamless...
Page 8
(It is recommended that a manifo ld with sight glass be used.) Boiling point at normal atmospheric pressure (reference) RefrigerantHFC32HFC125HFC134a Boiling point-52°C-49°C-26°C • • • • Use a special gauge manifo ld and charging hose. • • • • If refrigerant leaks occur, replace all of the refrigerant (same as for R22). • • • • Note that a R22 leak detector cannot be use to detect leaks. • • • • Refer to the Installation Instructions include d for the correct charging...
Page 9
3 SPECIFICATION (HEAT PUMP TYPE) 3.1. CS-W18BD3N / CU-W18BBN5 ITEM / MODELIndoor UnitOutdoor unit Main BodyCS-W18BD3NCU-W18BBN5 Cooling CapacitykW5.10 (BTU/h)(17,400) Heating CapacitykW5.60 (BTU/h)(19,100) Refrigerant Charge-lessm30 Standard Air Volume for High Speedm3/minHi 17 cfmHi 600 External Static PressuremmAqHi 7- PaHi 69 Air InletBackward SuctionBack sided Suction Air OutletFront blow-outFront blow-out Outside Dimension (H x W x D)mm270 x (780 + 100) x 650900 x 900 x 320 Net Weightkg (lbs)34...
Page 10
3.2. CS-W24BD3N / CU-W24BBN5 ITEM / MODELIndoor UnitOutdoor unit Main BodyCS-W24BD3NCU-W24BBN5 Cooling CapacitykW6.30 (BTU/h)(21,500) Heating CapacitykW7.10 (BTU/h)(24,200) Refrigerant Charge-lessm30 Standard Air Volume for High Speedm3/minHi 20 cfmHi 706 External Static PressuremmAqHi 7- PaHi 69 Air InletBackward SuctionBack sided Suction Air OutletFront blow-outFront blow-out Outside Dimension (H x W x D)mm270 x (1000 + 100) x 650900 x 900 x 320 Net Weightkg (lbs)40 (88)81 (179) Piping...