Panasonic Cs Kexxnb4x Cz 18bt1u Service Manual
Have a look at the manual Panasonic Cs Kexxnb4x Cz 18bt1u Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Indoor UnitCS-KE18NB4UW & CZ-18BT1U Outdoor UnitCU-KE18NKU < 208V >2-1-3. Vertical dB-A dB-A Indoor : Hi/Me/Lo Outdoor : Hi Air Filter Compressor Refrigerant / Amount charged at shipment Ibs (g) Refrigerant Control9.1 1,860( 1.2 to 9.1 ) ( 250 to 1,860 ) 17,500 5.15( 4,000 to 17,500 ) ( 1.2 to 5.15 )Cooling 10,600 6,900208V Single-Phase 60Hz 187 to 253 Refrigerant Tubing Connections Operation Sound Electrical Rating Sensible Capacity Latent Capacity W Power InputV A Available Voltage Range Running Amperes Narrow tube Wide tube Refrigerant inch (mm) Tube Diameter inch (mm)1/4 (6.35) 1/2 (12.7) ft (m) Max. allowable tubing length at shipmentFlare Type 25 (7.5) 44 / 40 / 36 5144 / 40 / 36 52 R410A / 2.87 (1,300) Electric Expansion ValveWashable, Anti-Mold DC Twin Rotary (Inverter)- Auto Timer Indoor / Outdoor Fan Speeds 24-Hour ON or OFF Timer, 1-Hour OFF Timer Auto and 3 steps / Auto (Hi, Me, Lo) Airflow Direction (Indoor) Horizontal Controls / Temperature Control Control UnitMicroprocessor / I.C. Thermister Wireless Remote Control Unit Features Compressor Locked Rotor AmperesBTU/h Performance % Power Factor 98 A 17.5 Voltage Rating BTU/hkW Total Capacity BTU/h SEER BTU/Wh 16 341(579) / 294(500) / 253(430) Air Circulation (Hi/Me/Lo) ft3/min (m3/h) 4.8920,400 6.0( 4,400 to 20,400 ) ( 1.3 to 6.0 )Heating - - 383(651) / 324(551) / 265(450) - Moisture Removal (High) Pints/h HSPF BTU/Wh - COP W/W - EER BTU/h/W 9.41 Fuse or Circuit Breaker Capacity A 1511.5 2,340( 1.3 to 11.5 ) ( 270 to 2,340 ) 98 - 8.5 2.56- Wired Remote Controller (Option) CZ-RD515U 11
Indoor UnitCS-KE18NB4UW & CZ-18BT1U Outdoor UnitCU-KE18NKU DATA SUBJECT TO CHANGE WITHOUT NOTICE. Shipping VolumeNet Shipping Weight Ib. (kg) Ib. (kg) cu.ft (m3) inch (mm) Dimensions & Weight (Indoor Unit) Unit Dimensions Height Width DepthIndividual Unit Body (CS-KE18NB4UW) Panel (CZ-18BT1U) Indoor Unit(CZ-KE18NB4UW & CZ-18BT1U) inch (mm) inch (mm) inch (mm) Package Dimensions Height Width Depthinch (mm) inch (mm) Shipping VolumeNet Shipping Weight Ib. (kg) Ib. (kg) cu.ft (m3) inch (mm) Dimensions & Weight (Outdoor Unit) Unit Dimensions Height Width DepthOutdoor Unit (CU-KE18NKU) inch (mm) (670)26-3/8 (880) 34-21/32 (285) 11-7/32 (1,012) 39-27/32 (44.0) 97.0 (48.0) 105.8 (0.28) 9.88 inch (mm) inch (mm) Package Dimensions Height Width Depthinch (mm) inch (mm) < 208V > - -(313) 12-5/16 (625) 24-19/32 (625) 24-19/32 (18.7) 41.3- - -22-5/8 (575) 35.3 (16) 11-5/32 (283) 22-5/8 (575) 28-1/8 (714) 11-13/32 (290) 24-13/16 (630) 41.9 (19) 4.59 (0.13)24-19/32 (625) 6.0 (2.7) 1-9/16 (40) 24-19/32 (625) 26-11/16 (678)4-1/8 (105) 26-3/16 (665) 7.7 (3.5) 1.65 (0.04) (733) 28-27/32 (379) 14-29/32 Remarks:Rating conditions are: Cooling: Indoor air temperature 80 °F DB / 67 °F WB Outdoor air temperature 95 °F DB / 75 °F WBHeating: Indoor air temperature 70 °F DB Outdoor air temperature 47 °F DB / 43 °F WB 12
Indoor Unit (Body)CS-KE12NB41 Indoor Unit (Panel)CZ-18BT1U 2-2. Major Component Specifications 2-2-1. Indoor Unit MPZN-12V ... 2 Flap Motor TypeStepping Motor Rating Model ... Q'ty Coil Resistance Ohm (Ambient Temp. 77 °F (25 °C))Each Pair of Terminal : 380 +/- 7%DC 12V PLD-12115ST-1 ... 1 AC115V, 60Hz 10.8 101 +/- 10% Coil Resistance Model ... Q'ty Rating Voltage, Hz Input Drain Pump OhmW DATA SUBJECT TO CHANGE WITHOUT NOTICE. Thermal Fuse 293 (145) (Ambient Temp. 68 °F (20 °C)) Safty Device Open Type °F (°C) Aluminum Plate Fin / Copper Tube 2 18.1 2.94 (0.273) Face Area Coil Rows Fins per inch Heat Exchanger Coil ft 2 (m2) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Ye s Control PCB Control Circuit Fuse ControlsPart No. Microprocessor 250V 3A CB-CS-KE12NB4U 1 ... D12-5/8 / L5-3/4 (D322/L147)Turbo DC Motor SIC-62FW-D866-2 ... 1 8 - DC160V / 23W470 / 520 Internal Controller Ye s - - Fan Q'ty ... Dia. and Length Type inch (mm) Fan Motor Rating Voltage / Nominal Output Coil ResistanceRough Measure RPM (Cool / Heat)Type Model ... Q'ty No. of Poles Safety Device Type Over- Current Protection Over- Heat Protection (Ambient Temp. 68 °F (20 °C)) Run Capacitor Micro F VAC Ohm 13
Indoor Unit (Body)CS-KE18NB4UW Indoor Unit (Panel)CZ-18BT1U MP24ZN-12V ... 2 Flap Motor TypeStepping Motor Rating Model ... Q'ty Coil Resistance Ohm (Ambient Temp. 77 °F (25 °C))Each Pair of Terminal : 380 +/- 7%DC 12V Aluminum Plate Fin / Copper Tube 2 18.1 2.94 (0.273) Face Area Coil Rows Fins per inch Heat Exchanger Coil ft 2 (m2) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Control PCB Control Circuit Fuse ControlsPart No. Microprocessor 250V 3A CB-CS-KE18NB4U 1 ... D12-5/8 / L5-3/4 (D322/L147)Turbo DC Motor SIC-62FV-D866-2 ... 1 8 - 650 / 720 Thermal Fuse - - Fan Q'ty ... Dia. and Length Type inch (mm) Fan Motor Coil ResistanceRough Measure RPM (Cool / Heat)Type Model ... Q'ty No. of Poles Safety Device Type (Ambient Temp. 68 °F (20 °C)) Run Capacitor Micro F VAC Ohm PLD-12230ST-1 ... 1 AC208 to 240V, 60Hz 10.8 333 +/- 10% Coil Resistance Model ... Q'ty Rating Voltage, Hz Input Drain Pump OhmW Thermal Fuse 293 (145) (Ambient Temp. 68 °F (20 °C)) Safty Device Open Type °F (°C) DATA SUBJECT TO CHANGE WITHOUT NOTICE.Ye s Ye s Over- Current Protection Over- Heat ProtectionDC340V / 20W Rating Voltage / Nominal Output 14
2-2-2. Outdoor Unit Control PCB Control Circuit Fuse ControlsPart No. Microprocessor 125V 25A CB-CU-KE12NK1 DATA SUBJECT TO CHANGE WITHOUT NOTICE. Pints (cc) WHT - BLU : BLU - RED : RED - WHT : 77.5 77.5 77.5 Micro F VAC External FinishAcrylic baked-on enamel finishFV50S ... 0.68 (320) - - Internal Controller Ye s Aluminum Plate Fin / Copper Tube 2 18.1 Face Area ft 2 (m2)3.95 (0.367) Coil Rows Fins per inch Heat Exchanger Coil SIC-67FV-F460-1... 1 Compressor Oil ... Amount 8 50 750 / 750 OhmDC Motor Type Compressor Model / Nominal Output Compressor Coil Resistance (Ambient Temp. 68 °F (20 °C)) OhmDC Rotary (Hermetic) G4C090LU1ER / 900W U - V : V - W : W - U :0.81 0.81 0.81 CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Safety Device Micro F VAC Run Capacitor Crankcase HeaterYe s Ye s Ye s Overload Relay CS-7L115 Model Operation Temp. Open : 239 °F (115 °C), Close : 203 °F (95 °C) - - 115V 20W 1 ... D15-3/4 (D400) Fan Propeller Q'ty ... Dia. inch (mm) Type Type Over- Current Protection (Ambient Temp. 68 °F (20 °C)) Fan Motor Nominal Output Coil Resistance Safety DeviceRough Measure RPM (Cool / Heat) Run Capacitor Type Model ... Q'ty No. of Poles W Outdoor UnitCU-KE12NK1 15
Outdoor UnitCU-KE18NKU Control PCB Control Circuit Fuse ControlsPart No. Microprocessor 250V 25A CB-CU-KE18NKU DATA SUBJECT TO CHANGE WITHOUT NOTICE. Pints (cc) WHT - BLU : BLU - RED : RED - WHT : 77.5 77.5 77.5 Micro F VAC External FinishAcrylic baked-on enamel finishFV50S ... 0.74 (350) - - Internal Controller Ye s Aluminum Plate Fin / Copper Tube 2 21.2 Face Area ft 2 (m2)5.49 (0.510) Coil Rows Fins per inch Heat Exchanger Coil SIC-67FV-F460-1 ... 1 Compressor Oil ... Amount 8 50 820 / 850 OhmDC Motor Type Compressor Model / Nominal Output Compressor Coil Resistance (Ambient Temp. 68 °F (20 °C)) OhmDC Twin Rotary (Hermetic) C-6RVN93H0M / 1,050W R - S : S - T : T - R :0.482 0.482 0.482 CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Safety Device Micro F VAC Run Capacitor Crankcase HeaterYe s Ye s Ye s Overload Relay CS-7L115 Model Operation Temp. Open : 239 °F (115 °C), Close : 203 °F (95 °C) - - - 1 ... D16-17/32 (D420) Fan Propeller Q'ty ... Dia. inch (mm) Type Type Over- Current Protection (Ambient Temp. 68 °F (20 °C)) Fan Motor Nominal Output Coil Resistance Safety DeviceRough Measure RPM (Cool / Heat) Run Capacitor Type Model ... Q'ty No. of Poles W 16
2-3. Other Component Specifications Indoor Unit CS-KE12NB41 & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U Outdoor Unit CU-KE12NK1 CU-KE18NKU 0 32 50 68 86 104 122 140 158 176 194 (0) (10) (20) (30) (40) (50) (60) (70) (80) (90) 40 60 80 100 120 140 160 180 200 20 50 1 0 2 3 4 5 6 7 8 9 10 59 68 77 86 95 104 (10) (15) (20) (25) (30) (35) (40) • Indoor air temp sensor (Model:KTEC-35-S98)• Indoor heat exchanger sensor (Model:PT2M-51H-S3) • Compressor temp sensor (CU-KE12NK1... Model:DTN-TKS274Y TH2) (CU-KE18NKU... Model:DTN-TKS293B) Resistance (k ohm)Resistance (k ohm) Temperature °F (°C) • Outdoor air temp sensor (CU-KE12NK1... Model:DTN-TKS269B) (CU-KE18NKU... Model:TKS295B) • Outdoor heat exchanger sensor (CU-KE12NK1... Model:DTN-TKS274Y TH1) (CU-KE18NKU... Model:TKS292B) 40 35 30 25 20 15 10 5 0 -4 5 14 23 32 41 50 59 68 ( -20)(-15)(-10) (-5) (0) (5) (10) (15) (20) Resistance (k ohm) Temperature °F (°C) Temperature °F (°C) 17
3. DIMENSIONAL DATA Indoor Unit CS-KE12NB41 & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U 6-5/16 6-11/16 1-3/16 (30) 4-19/32 1-25/32 1-25/32 2-3/32 8-15/32 22-5/8 (575) 11-5/32 (283) 3 65 Less than 31/32 Less than 31/32 3-5/8 22-5/8 (575) 12-7/8 Suspension bolt pitch Suspension bolt pitch21-1/32 (534) 21-1/32 (534) 12-7/16 23-5/8 (600) Ceiling opening dimensions 23-5/8 (600) Ceiling opening dimensions 7 Center of panel 24-19/32 (625) 24-19/32 (625)13-5/32 (334) 14-3/32 (358) 12 2 2 2 7-11/16 4-29/32 A View 8 1-3/16 21/32 3-1/8 The length of the suspension bolts should be selected so that there is a gap of 1-3/16" or the ceiling (21/32" or more below the lower surface of the main unit), as shown in the figure at right. If the suspension bolts is too long, it will contact the ceiling panel and the unit cannot be installed. A A Air intake Discharge outlet Refrigerant tubing (liquid tube) dia. 1/4" (flared) Refrigerant tubing (gas tube) dia. 1/2" (flared) Drain tube connection port VP20 (outer dia. 1") Power supply port Suspension bolt hole (4 - 1/2" x 1-1/8" hole) Fresh air intake duct connection port (dia. 3-7/8") 1 2 3 4 5 6 7 8 7-23/321-27/32 1-3/322-3/32 2-3/4 1-9/32 5-9/16 25/32 Unit : inch (mm) 18
10-13/16 3-19/32 ID:23/324-ID:15/16 21-3/16 6-3/32 4-9/32 2-5/32 Narrow tube service valve dia.1/4" (6.35) Wide tube service valve dia.3/8" (9.52) 3-19/32 15/32 10-7/16 (265) 11-13/32 12-7/16 Outdoor Unit CU-KE12NK1 Unit : inch (mm) (852-0-0010-12700-0) 28-11/32 (720) 2-1/8 21-9/16 (548) 5/8 19
Narrow tube service valve dia.1/4" (6.35)Wide tube service valve dia.1/2" (12.70) 4-3/8 2-5/326-17/32 5-23/32 3/32 26-3/8(670) 23/32 1-13/16 34-21/32(880)23-15/16 5-11/32 15/32 11-7/32(285) 12-7/32 13-5/32 11-17/32 ID:23/324-ID:15/161-3/8 2-17/32 2-13/32 Outdoor Unit CU-KE18NKU Unit : inch (mm) (852-0-0010-13200-0) 20