Home > Panasonic > Air Conditioner > Panasonic Cs C9gkv Cs C12gkv Cu C9gkv Cu C12gkv Repair Manual

Panasonic Cs C9gkv Cs C12gkv Cu C9gkv Cu C12gkv Repair Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cs C9gkv Cs C12gkv Cu C9gkv Cu C12gkv Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							© 2006 Panasonic HA Air-Conditioning (M) Sdn.
    Bhd. (11969-T). All rights reserved. Unauthorized
    copying and distribution is a violation of law.
    Order No. MAC0612065C3
    Air Conditioner
    CS-C9GKV CU-C9GKV
    CS-C12GKV CU-C12GKV
    TABLE OF CONTENTS
    PA G E PA G E
    1 Safety Precautions-----------------------------------------------3
    2 Specifications-----------------------------------------------------5
    2.1. CS-C9GKV CU-C9GKV---------------------------------- 5
    2.2. CS-C12GKV CU-C12GKV ------------------------------ 7
    3 Features-------------------------------------------------------------9
    4 Location of Controls and Components------------------10
    4.1. Product Overview-----------------------------------------10
    5Dimensions--------------------------------------------------------11
    5.1. Indoor Unit & Remote Control ------------------------- 115.2. Outdoor Unit ----------------------------------------------- 12
    6 Refrigeration Cycle Diagram--------------------------------13
    7 Block Diagram---------------------------------------------------14
    8 Wiring Connection Diagram---------------------------------15
    8.1. CS-C9GK CU-C9GK / CS-C12GK CU-C12GK --- 15
    9 Electronic Circuit Diagram-----------------------------------16
    10 Printed Circuit Board------------------------------------------17
    10.1. Indoor Unit ------------------------------------------------- 17
    10.2. Indicator ---------------------------------------------------- 19 
    						
    							2 11 Installation Instruction----------------------------------------20
    11.1. Select The Best Location ------------------------------ 20
    11.2. Indoor Unit ------------------------------------------------- 21
    11.3. Outdoor Unit ----------------------------------------------- 23
    12 Operation and Control-----------------------------------------26
    12.1. Cooling Operation ---------------------------------------- 26
    12.2. Soft Dry Operation --------------------------------------- 27
    12.3. Automatic Operation------------------------------------- 28
    12.4. Operation Control ---------------------------------------- 29
    12.5. Indoor Fan Speed Control ----------------------------- 32
    12.6. Outdoor Fan Speed Control --------------------------- 33
    12.7. Vertical Airflow Direction Control --------------------- 34
    12.8. Horizontal Airflow Direction Control ----------------- 34
    12.9. Powerful Operation -------------------------------------- 34
    12.10. Quiet Operation ------------------------------------------- 35
    12.11. Timer Control ---------------------------------------------- 36
    12.12. Random Auto Restart Control------------------------- 36
    12.13. Remote Control Signal Receiving Sound ---------- 36
    12.14. Patrol Operation ------------------------------------------ 37
    12.15. e-ion Operation ------------------------------------------- 40
    13 Servicing Mode--------------------------------------------------43
    13.1. Auto OFF/ON Button ------------------------------------ 43
    13.2. Select Remote Control Transmission Code ------- 43
    13.3. Remote Control Button --------------------------------- 44
    14 Troubleshooting Guide----------------------------------------45
    14.1. Refrigeration cycle system----------------------------- 45
    15 Disassembly and Assembly Instructions---------------47
    15.1. Indoor Electronic Controllers and Control
    Board Removal Procedures --------------------------- 47
    15.2. Indoor Fan Motor and Cross Flow Fan
    Removal Procedures ------------------------------------ 49
    16 Technical Data----------------------------------------------------51
    16.1. Thermostat Characteristics ---------------------------- 51
    16.2. Operation Characteristics ------------------------------ 52
    17 Exploded View and Replacement Parts List-----------56
    17.1. Indoor Unit ------------------------------------------------- 56
    17.2. Outdoor UnitCU-C9GKV ------------------------------- 58
    17.3. Outdoor UnitCU-C12GKV ------------------------------ 59 
    						
    							
     6DIHW\3UHFDXWLRQV
    
    						
    							4
    4. Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70qF (30 - 40qC) higher. Please use
    a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20qF (370 ± 10qC).
    Pb free solder will tend to splash when heated too high (about 1100qF / 600qC).
    5. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare
    may break and cause refrigerant gas leakage.
    6. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury.
    AT T E N T I O N
    1. Selection of the installation location. Select an installation location which is rigid and strong enough to support or hold the unit, and select a
    location for easy maintenance.
    2. Power supply connection to the conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following
    methods.
    Power supply point shall be the place where there is ease for ease for access for the power disconnection in case of emergency.
    In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
    1. Power supply connection to the receptacle using a power plug. Use an approved power plug with earth pin for the connection to the
    socket.
    2. Power supply connection to a circuit breaker for the permanent connection. Use an approved circuit breaker for the permanent
    connection. It must be a double pole switch with a minimum 3.5 mm contact gap.
    3. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigeration parts. Take care of
    the liquid refrigerant, it may cause frostbite.
    4. Installation work. It may need two people to carry out the installation work.
    5. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc. 
    						
    							5
    2 Specifications
    2.1. CS-C9GKV CU-C9GKV
    1. Cooling capacities are based on indoor temperature of 27qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air
    temperature of 35qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.)
    ItemUnit Indoor unit Outdoor unit
    Performance Test Condition JIS
    Capacity kW 2.65
    BTU/h 9040
    *kJ/h 9540
    EER W/W 3.19
    BTU/hW 10.9
    Noise Level dB (A) High: 36 Low: 26 High: 48
    Power level dB High: 49 High: 63
    Moisture Removal l/h 1.6
    (pt/h) 3.4
    Air Volume Lo
    m
    3/m (ft3/m)5.2 (183) —
    Me
    m3/m (ft3/m)7.1 (251) —
    Hi
    m3/m (ft3/m)8.6 (300) 29.2 (1030)
    SHi
    m3/m (ft3/m)9.2 (326) —
    Refrigerant Control Device — Capillary Tube
    Refrigerant Oil (Charged)
    cm
    3— ATMOS M60 or
    SUNISO 4GDID (350cm3)
    Refrigerant (Charged) R22 kg (oz) — 0.59 (20.8)
    Dimension Height mm (inch) 280 (11 - 1/32) 510 (20 - 3/32)
    Width mm (inch) 799 (31 - 15/32) 650 (25 - 19/32)
    Depth mm (inch) 183 (7 - 7/32) 230 (9 - 1/16)
    Net Weight kg (lbs) 9 (20) 23 (51)
    Pipe Diameter Gas mm (inch) 9.52 (3/8”)
    Liquid mm (inch) 6.35 (1/4”)
    Height Difference m (ft) 5 (16.4)
    Pipe Length Range m (ft) 3 (9.8) - 10 (32.8)
    Additional Gas Amount g/m (oz/ft) 10 (0.1)
    Refrigeration Charge Less m (ft) 7.5 (24.6)
    Drain Hose Inner diameter mm 16 —
    Length mm 650 —
    Compressor Type — Rotary (1 cylinder)
    rolling piston type
    Motor Type — Induction (2-poles)
    Rated Output W — 600
    Fan Type Cross-flow Fan Propeller Fan
    Material ASG20K1 PP Resin
    Motor Type Induction (4-poles) Induction (6-poles)
    Input power W 55.0 74.0
    Output power W 15 30
    Fan Speed Lo (Cool) rpm 730 —
    Me (Cool) rpm 1000 —
    Hi (Cool) rpm 1210 810
    SHi (Cool) rpm 1300 —
    Heat Exchanger Fin material Aluminium (Pre Coat) Aluminium (Blue Coat)
    Fin Type Slit Fin Louver Fin
    Rowu Stage u FPI 2 u 15 u 19 1 u 19 u 17
    Size (W u H u L) mm (inch) 610 u 315 u 25.4 25.4 u 483 u 576
    Air Filter Type Material Polypropelene —
    Style One-touch — 
    						
    							6 Note:
     Specification are subjected to change without prior notice for further improvement.
     Item Unit
    Power Source (Phase, Voltage, Cycle) ø Single
    V 220
    Hz 60
    Input power W 830
    Starting Current A 23.0
    Running Current Cooling A 3.9
    Power Factor Cooling A 93
    Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    Power Cord Number of core 3 (1.5mm)
    Length m (ft) 2 (6)
    Thermostat—
    Protection Device2 Stage Overload Protector 
    						
    							7
    2.2. CS-C12GKV CU-C12GKV
    1. Cooling capacities are based on indoor temperature of 27qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air
    temperature of 35qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.)
    ItemUnit Indoor unit Outdoor unit
    Performance Test Condition JIS
    Capacity kW 3.56
    BTU/h 12140
    *kJ/h 12820
    EER W/W 3.21
    BTU/hW 10.9
    Noise Level dB (A) High: 39 Low: 29 High: 48
    Power level dB High: 52 High: 63
    Moisture Removal l/h 2.1
    (pt/h) 4.4
    Air Volume Lo
    m
    3/m (ft3/m)6.0 (211) —
    Me
    m3/m (ft3/m)7.9 (280) —
    Hi
    m3/m (ft3/m)9.5 (340) 32.4 (1140)
    SHi
    m3/m (ft3/m)9.9 (349) —
    Refrigerant Control Device — Capillary Tube
    Refrigerant Oil (Charged)
    cm
    3— ATMOS M60 or
    SUNISO 4GDID (350cm3)
    Refrigerant (Charged) R22 kg (oz) — 0.77 (27.2)
    Dimension Height mm (inch) 280 (11 - 1/32) 540 (21 - 1/4)
    Width mm (inch) 799 (31 - 15/32) 780 (30 - 23/32)
    Depth mm (inch) 183 (7 - 7/32) 289 (11 - 3/8)
    Net Weight kg (lbs) 9 (20) 33 (73)
    Pipe Diameter Gas mm (inch) 12.70 (1/2”)
    Liquid mm (inch) 6.35 (1/4”)
    Height Difference m (ft) 5 (16.4)
    Pipe Length Range m (ft) 3 (9.8) - 15 (49.2)
    Additional Gas Amount g/m (oz/ft) 10 (0.1)
    Refrigeration Charge Less m (ft) 7.5 (24.6)
    Drain Hose Inner diameter mm 16 —
    Length mm 650 —
    Compressor Type — Rotary (1 cylinder)
    rolling piston type
    Motor Type — Induction (2-poles)
    Rated Output W — 850
    Fan Type Cross-flow Fan Propeller Fan
    Material ASG20K1 PP Resin
    Motor Type Induction (4-poles) Induction (6-poles)
    Input power W 55.0 74.0
    Output power W 15 30
    Fan Speed Lo (Cool) rpm 800 —
    Me (Cool) rpm 1060 —
    Hi (Cool) rpm 1270 835
    SHi (Cool) rpm 1320 —
    Heat Exchanger Fin material Aluminium (Pre Coat) Aluminium (Blue Coat)
    Fin Type Slit Fin Louver Fin
    Rowu Stage u FPI 2 u 15 u 21 1 u 20 u 19
    Size (W u H u L) mm (inch) 610 u 315 u 25.4 22.0 u 508 u 823
    Air Filter Type Material Polypropelene —
    Style One-touch — 
    						
    							8 Note:
     Specification are subjected to change without prior notice for further improvement.
     Item Unit
    Power Source (Phase, Voltage, Cycle) ø Single
    V 220
    Hz 60
    Input power kW 1.11
    Starting Current A 33
    Running Current Cooling A 5.3
    Power Factor Cooling A 95
    Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    Power Cord Number of core 3 (1.5mm)
    Length m (ft) 2 (6)
    Thermostat—
    Protection Device2 Stage Overload Protector 
    						
    							9
    3Features
    • High Efficiency
     Compact Design
     Wider range of horizontal discharge air
     Air Filter with function to reduce dust and smoke
     Automatic air swing and manual adjusted by Remote
    Control for vertical airflow
    Long Installation Piping
    -CS/CU-C9GK, long piping up to 10 meter
    -CS/CU-C12GK, long piping up to 15 meter
     e-ion Air Purifying System with Patrol Sensor
    - Discharged Active e-ions capture dust particles and
    bring it back with a boomerang-like mechanism
    Quality Improvement
    -Random auto restart after power failure for safety restart
    operation
    - Gas leakage protection
    - Prevent compressor reverse cycle
    - Inner protector to protect Compressor
    - Noise prevention during soft dry operation
    -Blue Coated Condenser for high resistance to corrosion
     Operation Improvement
    -Quiet mode to provide quiet operation
    - Powerful mode to reach the desired room temperature
    quickly
    - 24-hour timer setting
     Serviceability Improvement
    -Removable and washable front panel 
    						
    							10
    4 Location of Controls and Components
    4.1. Product Overview
    4.1.1. Indoor Unit
    4.1.2. Outdoor Unit
    4.1.3. Remote Control 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cs C9gkv Cs C12gkv Cu C9gkv Cu C12gkv Repair Manual