© 2006 Panasonic HA Air-Conditioning (M) Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. Order No. MAC0612065C3 Air Conditioner CS-C9GKV CU-C9GKV CS-C12GKV CU-C12GKV TABLE OF CONTENTS PA G E PA G E 1 Safety Precautions-----------------------------------------------3 2 Specifications-----------------------------------------------------5 2.1. CS-C9GKV CU-C9GKV---------------------------------- 5 2.2. CS-C12GKV CU-C12GKV ------------------------------...
Page 2
2 11 Installation Instruction----------------------------------------20 11.1. Select The Best Location ------------------------------ 20 11.2. Indoor Unit ------------------------------------------------- 21 11.3. Outdoor Unit ----------------------------------------------- 23 12 Operation and Control-----------------------------------------26 12.1. Cooling Operation ---------------------------------------- 26 12.2. Soft Dry Operation --------------------------------------- 27 12.3. Automatic...
Page 4
4 4. Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70qF (30 - 40qC) higher. Please use a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20qF (370 ± 10qC). Pb free solder will tend to splash when heated too high (about 1100qF / 600qC). 5. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and...
Page 5
5 2 Specifications 2.1. CS-C9GKV CU-C9GKV 1. Cooling capacities are based on indoor temperature of 27qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air temperature of 35qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.) ItemUnit Indoor unit Outdoor unit Performance Test Condition JIS Capacity kW 2.65 BTU/h 9040 *kJ/h 9540 EER W/W 3.19 BTU/hW 10.9 Noise Level dB (A) High: 36 Low: 26 High: 48 Power level dB High: 49 High: 63 Moisture Removal l/h 1.6 (pt/h) 3.4 Air Volume Lo m 3/m (ft3/m)5.2 (183)...
Page 6
6 Note: Specification are subjected to change without prior notice for further improvement. Item Unit Power Source (Phase, Voltage, Cycle) ø Single V 220 Hz 60 Input power W 830 Starting Current A 23.0 Running Current Cooling A 3.9 Power Factor Cooling A 93 Power factor means total figure of compressor, indoor fan motor and outdoor fan motor. Power Cord Number of core 3 (1.5mm) Length m (ft) 2 (6) Thermostat— Protection Device2 Stage Overload Protector
Page 7
7 2.2. CS-C12GKV CU-C12GKV 1. Cooling capacities are based on indoor temperature of 27qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air temperature of 35qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.) ItemUnit Indoor unit Outdoor unit Performance Test Condition JIS Capacity kW 3.56 BTU/h 12140 *kJ/h 12820 EER W/W 3.21 BTU/hW 10.9 Noise Level dB (A) High: 39 Low: 29 High: 48 Power level dB High: 52 High: 63 Moisture Removal l/h 2.1 (pt/h) 4.4 Air Volume Lo m 3/m (ft3/m)6.0 (211) — Me m3/m...
Page 8
8 Note: Specification are subjected to change without prior notice for further improvement. Item Unit Power Source (Phase, Voltage, Cycle) ø Single V 220 Hz 60 Input power kW 1.11 Starting Current A 33 Running Current Cooling A 5.3 Power Factor Cooling A 95 Power factor means total figure of compressor, indoor fan motor and outdoor fan motor. Power Cord Number of core 3 (1.5mm) Length m (ft) 2 (6) Thermostat— Protection Device2 Stage Overload Protector
Page 9
9 3Features • High Efficiency Compact Design Wider range of horizontal discharge air Air Filter with function to reduce dust and smoke Automatic air swing and manual adjusted by Remote Control for vertical airflow Long Installation Piping -CS/CU-C9GK, long piping up to 10 meter -CS/CU-C12GK, long piping up to 15 meter e-ion Air Purifying System with Patrol Sensor - Discharged Active e-ions capture dust particles and bring it back with a boomerang-like mechanism Quality Improvement -Random...
Page 10
10 4 Location of Controls and Components 4.1. Product Overview 4.1.1. Indoor Unit 4.1.2. Outdoor Unit 4.1.3. Remote Control