© 2006 Panasonic HA Air-Conditioning (M) Sdn.
Bhd. (11969-T). All rights reserved. Unauthorized
copying and distribution is a violation of law.
Order No. MAC0612065C3
Air Conditioner
CS-C9GKV CU-C9GKV
CS-C12GKV CU-C12GKV
TABLE OF CONTENTS
PA G E PA G E
1 Safety Precautions-----------------------------------------------3
2 Specifications-----------------------------------------------------5
2.1. CS-C9GKV CU-C9GKV---------------------------------- 5
2.2. CS-C12GKV CU-C12GKV ------------------------------...

Page 2

2 11 Installation Instruction----------------------------------------20
11.1. Select The Best Location ------------------------------ 20
11.2. Indoor Unit ------------------------------------------------- 21
11.3. Outdoor Unit ----------------------------------------------- 23
12 Operation and Control-----------------------------------------26
12.1. Cooling Operation ---------------------------------------- 26
12.2. Soft Dry Operation --------------------------------------- 27
12.3. Automatic...

Page 3


 6DIHW\3UHFDXWLRQV

Page 4

4
4. Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70qF (30 - 40qC) higher. Please use
a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20qF (370 ± 10qC).
Pb free solder will tend to splash when heated too high (about 1100qF / 600qC).
5. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare
may break and...

Page 5

5
2 Specifications
2.1. CS-C9GKV CU-C9GKV
1. Cooling capacities are based on indoor temperature of 27qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air
temperature of 35qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.)
ItemUnit Indoor unit Outdoor unit
Performance Test Condition JIS
Capacity kW 2.65
BTU/h 9040
*kJ/h 9540
EER W/W 3.19
BTU/hW 10.9
Noise Level dB (A) High: 36 Low: 26 High: 48
Power level dB High: 49 High: 63
Moisture Removal l/h 1.6
(pt/h) 3.4
Air Volume Lo
m
3/m (ft3/m)5.2 (183)...

Page 6

6 Note:
 Specification are subjected to change without prior notice for further improvement.
 Item Unit
Power Source (Phase, Voltage, Cycle) ø Single
V 220
Hz 60
Input power W 830
Starting Current A 23.0
Running Current Cooling A 3.9
Power Factor Cooling A 93
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord Number of core 3 (1.5mm)
Length m (ft) 2 (6)
Thermostat—
Protection Device2 Stage Overload Protector 

Page 7

7
2.2. CS-C12GKV CU-C12GKV
1. Cooling capacities are based on indoor temperature of 27qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air
temperature of 35qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.)
ItemUnit Indoor unit Outdoor unit
Performance Test Condition JIS
Capacity kW 3.56
BTU/h 12140
*kJ/h 12820
EER W/W 3.21
BTU/hW 10.9
Noise Level dB (A) High: 39 Low: 29 High: 48
Power level dB High: 52 High: 63
Moisture Removal l/h 2.1
(pt/h) 4.4
Air Volume Lo
m
3/m (ft3/m)6.0 (211) —
Me
m3/m...

Page 8

8 Note:
 Specification are subjected to change without prior notice for further improvement.
 Item Unit
Power Source (Phase, Voltage, Cycle) ø Single
V 220
Hz 60
Input power kW 1.11
Starting Current A 33
Running Current Cooling A 5.3
Power Factor Cooling A 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord Number of core 3 (1.5mm)
Length m (ft) 2 (6)
Thermostat—
Protection Device2 Stage Overload Protector 

Page 9

9
3Features
• High Efficiency
 Compact Design
 Wider range of horizontal discharge air
 Air Filter with function to reduce dust and smoke
 Automatic air swing and manual adjusted by Remote
Control for vertical airflow
Long Installation Piping
-CS/CU-C9GK, long piping up to 10 meter
-CS/CU-C12GK, long piping up to 15 meter
 e-ion Air Purifying System with Patrol Sensor
- Discharged Active e-ions capture dust particles and
bring it back with a boomerang-like mechanism
Quality Improvement
-Random...

Page 10

10
4 Location of Controls and Components
4.1. Product Overview
4.1.1. Indoor Unit
4.1.2. Outdoor Unit
4.1.3. Remote Control 