Panasonic Cs C9gkq Cs C12gkq Cu C9gkq Cu C12gkq Repair Manual
Here you can view all the pages of manual Panasonic Cs C9gkq Cs C12gkq Cu C9gkq Cu C12gkq Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
© 2006 Panasonic HA Air-Conditioning (M) Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. Order No. MAC0610049C3 Air Conditioner CS-C9GKQ CU-C9GKQ CS-C12GKQ CU-C12GKQ TABLE OF CONTENTS PA G E PA G E 1 Safety Precautions-----------------------------------------------3 2 Specifications-----------------------------------------------------5 2.1. CS-C9GKQ CU-C9GKQ --------------------------------- 5 2.2. CS-C12GKQ CU-C12GKQ------------------------------ 7...
Page 2
2 12.14. Patrol Operation ------------------------------------------ 37 12.15. e-ion Operation ------------------------------------------- 40 13 Servicing Mode--------------------------------------------------43 13.1. Auto OFF/ON Button ------------------------------------ 43 13.2. Select Remote Control Transmission Code ------- 43 13.3. Remote Control Button --------------------------------- 44 14 Troubleshooting Guide----------------------------------------45 14.1. Refrigeration cycle...
Page 3
3 1Safety Precautions •Read the following “SAF ETY PRECAUTIONS” ca refully before pe rform any servicing. •Electrical wo rk mu st be installed or serviced by a licensed elec trician. Be sure to use the correct rating of the po wer plug and main circuit for the model installed. •The caution items stated here must be followed be cause these important contents are rela ted to safety. The me aning of each in d ication used is as be low. Incorrect installation or servicing due to igno ring of the...
Page 4
4 4. Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). Pb free solder will tend to splash when heated too high (about 1100°F / 600°C). 5. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and...
Page 5
5 2 Specifications 2.1. CS-C9GKQ CU-C9GKQ 1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.) 2. Heating capacities are based on indoor temperature of 20°C D.B. (80.6°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.), 6°C W.B. (42.8°F W.B.) ItemUnit Indoor unit Outdoor unit Performance Test Condition PNS Capacity kW 2.65 BTU/h 9040 *kJ/h 9540 EER W/W 3.19...
Page 6
6 Note: • Specification are subjected to change without prior notice for further improvement. Item Unit Power Source (Phase, Voltage, Cycle) ø Single V 230 Hz 60 Input power W 830 Starting Current A 23.0 Running Current Cooling A 3.9 Power Factor Cooling A 93 Power factor means total figure of compressor, indoor fan motor and outdoor fan motor. Power Cord Number of core 3 (1.5mm) Length m (ft) 2 (6) Thermostat— Protection Device2 Stage Overload Protector
Page 7
7 2.2. CS-C12GKQ CU-C12GKQ 1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.) 2. Heating capacities are based on indoor temperature of 20°C D.B. (80.6°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.), 6°C W.B. (42.8°F W.B.) ItemUnit Indoor unit Outdoor unit Performance Test Condition PNS Capacity kW 3.55 BTU/h 12100 *kJ/h 12780 EER W/W 3.09 BTU/hW 11.1 Noise...
Page 8
8 Note: • Specification are subjected to change without prior notice for further improvement. Item Unit Power Source (Phase, Voltage, Cycle) ø Single V 230 Hz 60 Input power kW 1.15 Starting Current A 33 Running Current Cooling A 5.1 Power Factor Cooling A 98 Power factor means total figure of compressor, indoor fan motor and outdoor fan motor. Power Cord Number of core Length m (ft) Thermostat— Protection Device2 Stage Overload Protector
Page 9
9 3Features • High Efficiency • Compact Design • Wider range of horizontal discharge air • Air Filter with function to reduce dust and smoke • Automatic air swing and manual adjusted by Remote Control for vertical airflow •Long Installation Piping -CS/CU-C9GK, long piping up to 10 meter -CS/CU-C12GK, long piping up to 15 meter • e-ion Air Purifying System with Patrol Sensor - Discharged Active e-ions capture dust particles and bring it back with a boomerang-like mechanism •Quality Improvement -Random...
Page 10
10 4 Location of Controls and Components 4.1. Product Overview 4.1.1. Indoor Unit 4.1.2. Outdoor Unit 4.1.3. Remote Control