Panasonic Cs A9ekh Cu A9ekh Cs A12ekh Cu A12ekh Repair Manual
Here you can view all the pages of manual Panasonic Cs A9ekh Cu A9ekh Cs A12ekh Cu A12ekh Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 51
51 • How to remove PCBs from the control board - Pull the hook then remove the particular piece. (Fig. 4) - Remove connector red and blue from the terminal board. (Fig. 4) - Release CN-DISP. (Fig. 4) - Release CN-STM. (Fig. 4) - Release CN-TH. (Fig. 4) - Release CN-SONIC. (Fig. 4) - Release CN-FB. (Fig. 4) - Release CN-DATA. (Fig. 4) - Release CN-FM. (Fig. 4) - Remove RY-PWR connector (black and brown) and AC-WHT connector from power PCB. - Pull the hooks and remove the PCBs. Fig. 4
Page 52
52 14.2. Indoor Fan Motor and Cross Flow Fan Removal Procedures • Pull down the Discharge Grille Complete. (Fig. 5) Fig. 5• Remove the earth wire from the evaporator. (Fig. 6) • Remove 2 screws on the right and 1 screw at the left side of control board. (Fig. 6) • Then pull out the control board from the unit. (Fig. 6) Fig. 6• Remove the cross flow fan bushing from the chassis. (Fig. 7) • Loosen the fan boss screw at the cross flow fan. Fig. 7
Page 53
53 • Pull the hook at the left side of evaporator. (Fig. 7) • Then push up the evaporator and remove cross flow fan by pulling both cross flow fan and fan motor. (Fig. 8) Fig. 8