Home > Panasonic > Air Conditioner > Panasonic Cs A9ekh Cu A9ekh Cs A12ekh Cu A12ekh Repair Manual

Panasonic Cs A9ekh Cu A9ekh Cs A12ekh Cu A12ekh Repair Manual

Here you can view all the pages of manual Panasonic Cs A9ekh Cu A9ekh Cs A12ekh Cu A12ekh Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 1

1
Order No. MAC0601006C3
Air Conditioner
CS-A9EKH CU-A9EKH
CS-A12EKH CU-A12EKH
TABLE OF CONTENTS
PA G E PA G E
1 Safety Precautions-----------------------------------------------3
2 Specifications------------------------------------------------------5
2.1. CS-A9EKH CU-A9EKH -----------------------------------5
2.2. CS-A12EKH CU-A12EKH ------------------------------- 7
3Features--------------------------------------------------------------9
4 Location of Controls and Components------------------10
4.1....

Page 2

2 12.3. Test Mode Timer Table---------------------------------- 47
13 Troubleshooting Guide----------------------------------------48
13.1. Refrigeration Cycle System --------------------------- 48
13.2. Relationship Between The Condition of The
Air Conditioner and Pressure and Electric
Current ------------------------------------------------------ 49
13.3. Diagnosis Methods Of A Malfunction Of A
Compressor And 4-way Valve ------------------------ 49
14 Disassembly and Assembly...

Page 3

3
1 Safety Precautions
• Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.
• Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and
main circuit for the model installed.
• The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below. Incorrect installation or servicing due to ignoring of the instruction will cause...

Page 4

4 AT T E N T I O N
1. Selection of the installation location. Select an installation location which is rigid and strong enough to support or hold the unit, and select a
location for easy maintenance.
2. Power supply connection to the conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following
methods.
Power supply point shall be the place where there is ease for ease for access for the power disconnection in case of emergency.
In some countries, permanent...

Page 5

5
2 Specifications
2.1. CS-A9EKH CU-A9EKH
Unit Indoor unit Outdoor unit
Power Source (Phase, Voltage, Cycle) ø, V, Hz Single, 220 - 240, 50
Cooling Capacity kW (BTU/h) 2.65 - 2.65 (9,040 - 9,040)
Heating Capacity kW (BTU/h) 2.80 - 2.85 (9,550 - 9,720)
Moisture Removal l/h (Pint/h) 1.6 (3.4)
Airflow Method OUTLET SIDE VIEW TOP VIEW
INTAKE
Air Volume Lo
m
3/min (cfm)Cooling; 6.4 (228) - 6.4 (228)    
Heating; 6.7 (237) - 6.7 (237)—
Me
m
3/min (cfm)Cooling; 7.8 (274) - 7.8 (274)    
Heating; 7.5 (266) - 7.5...

Page 6

6 Note:
• Specifications are subject to change without notice for further improvement.
Fan Motor Description Cross-flow Fan Propeller Fan
Material ASG32K1 PP Resin
Motor Type Induction (4-poles) Induction (6-poles)
Input W 60.5 - 66.0 66 - 74.8
Rated Output W 15 30
Fan Speed Low rpm Cooling; 830 - 830
Heating; 890 - 890—
Medium rpm Cooling; 1000 - 1000
Heating; 1000 - 1000—
High rpm Cooling; 1210 - 1210
Heating; 1300 - 1300800 - 830
SuperHigh rpm Cooling; 1300 - 1300
Heating; ——
Heat Exchanger...

Page 7

7
2.2. CS-A12EKH CU-A12EKH
Unit Indoor unit Outdoor unit
Power Source (Phase, Voltage, Cycle) ø, V, Hz Single, 220 - 240, 50
Cooling Capacity kW (BTU/h) 3.52 - 3.57 (12,000 - 12,200)
Heating Capacity kW (BTU/h) 3.90 - 4.00 (13,300 - 13,640)
Moisture Removal l/h (Pint/h) 2.1 (4.4)
Airflow Method OUTLET SIDE VIEW TOP VIEW
INTAKE
Air Volume Lo
m
3/min (cfm)Cooling; 6.1 (215) - 6.1 (215)
Heating; 6.5 (230) - 6.5 (230)—
Me
m
3/min (cfm)Cooling; 8.5 (301) - 8.5 (301)
Heating; 8.5 (300) - 8.5 (300)—
Hi
m
3/min...

Page 8

8 Note:
• Specifications are subject to change without notice for further improvement.
Fan Motor Description Cross-flow Fan Propeller Fan
Material ASG32K1 PP Resin
Motor Type Induction (4-poles) Induction (6-poles)
Input W 60.5 - 66.0 71.5 - 80.3
Rated Output W 15 31
Fan Speed Low rpm Cooling; 800 - 800
Heating; 860 - 860—
Medium rpm Cooling; 1,120 - 1,120
Heating; 1,120 - 1,120—
High rpm Cooling; 1300 - 1300
Heating; 1320 - 1320845 - 860
SuperHigh rpm Cooling; 1320 - 1320
Heating; ——
Heat Exchanger...

Page 9

9
3Features
• High Efficiency
• Compact Design
• Wider range of horizontal discharge air
• Air Filter with function to reduce dust and smoke
• Automatic air swing and manual adjusted by Remote
Control for vertical airflow
•Long Installation Piping
-CS/CU-A9EK, long piping up to 10 meter
-CS/CU-A12EK, long piping up to 15 meter
• Supersonic Air Purifying Device with SUPER alleru-
buster
- Inactivate various harmful airborne elements including
allergens, viruses and bacteria
- Generated supersonic waves...

Page 10

10
4 Location of Controls and Components
4.1. Product Overview
4.1.1. Indoor Unit
4.1.2. Outdoor Unit
4.1.3. Remote Control 
Start reading Panasonic Cs A9ekh Cu A9ekh Cs A12ekh Cu A12ekh Repair Manual