10 Installation Instructions Required tools forInstallationWorks 1.Philips screw driver5.Spanner9.Gas leak detector13.Multimeter 2.Level gauge6.Pipe cutter10.Measuring tape14.Torque wrench 18 N.m (1.8 kgf.m) 42 N.m (4.2 kgf.m) 55 N.m (5.5 kgf.m) 3.Electric drill, hole core drill (ø70 mm)7.Reamer11.Thermometer15.Vacuum pump 4.Hexagonal wrench (4 mm)8.Knife12.Megameter16.Gauge manifo ld 10.1. Safety Precautions • Read the following “SAFETY PRECAUTIONS” carefully before installation. • Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be installed. • The caution items stated here must be followed because theseimportant contents are related tosafety. The meaningof each indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the seriousness is classified bythe following indications. This indication shows the possibility of causing death or serious injury. This indication shows the possibility of causing injury or damage to properties only. The items to be followed are classified by the symbols: Symbol with background white denotesitem that is PROHIBITED from doing. • Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference. 1.Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 2.Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 3.Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock. 4.Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. 5.For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 6.Use the specified cable (1.5 mm2) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection. 7.Wirerouting must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock. 8.Whencarrying out piping connection, take care notto let air substances other than the specified refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury. 9.Do not damage or use unspecified power supply cord.Otherwise, it will cause fire or electrical shock. 10.Do not modify the length of thepower supply cord oruse of the extension cord, and do not share the single outlet with other electrical applian ces. Otherwise, it will cause fire or electrical shock. 45 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
1.The equipment must be earthed. It may cause electrical shock if grounding is not perfect. 2.Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire. 3.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture. 1.Selection of the installation location. Select a installation location which is rigid and strong enough to support or hold the unit, and select alocation for easy maintenance. 2.Power supply connectionto the room air conditioner. Connect the power supply cordof the room air conditioner to the mains using one of the following method. Power supply point shall be theplace where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this roomair conditioner to thepower supply is prohibited. 1. Power supply connection to the receptacle using a power plug. Use an approved 15A/16A power plug with earth pin for the connection to the socket. 2. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3 mm contact gap. 3.Do not release refrigerant. Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the liquid refrigerant, it may cause frostbite. 4.Installation work. It may need two people to carry out the installation work. 5.Do not install this applian ce in a laundry room or other location where water may drip from the ceiling, etc. 46 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
Applicable piping kit CZ-3F5, 7AEN (C7DK, C9DK, A7DK, A9DK, ) CZ-4F5,7, 10AN (C12DK, A12DK) 10.3. Select the best location INDOOR UNIT • There should not be any heat source or steam near the unit. • There should not be any obstacles blocking the air circulation. • A place where air circulation in the room is good. • A place where drainage can be easily done. • A place where noise prevention is taken into consideration. • Do not install the unit near the doorway. • Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles. • Recommended installation height for indoor unit shall be at least 2.3 m. OUTDOOR UNIT • If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not obstructed. • There should not be any animal or plant which could be affected by hot air discharged. • Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles. • Do not place any obstacles which may cause a short circuit of the discharged air. • If piping length is over the common length, additional refrigerant should be added as shown in the table. 10.4. Indoor/Outdoor Unit Installation Diagram • This illustration isfor explanationpurposesonly. The indoor unit will actually face a differentway. 10.2. Attached accessories 47 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
10.5.1. SELECT THE BEST LOCATION (Refer to “Select the best location” section) 10.5.2. HOW TO FIX INSTALLATION PLATE The mounting wall is strong and solid enough to prevent it from the vibration. The centre of installation plate should be at more than 450 mm at right and left of the wall. The distance from installation plate edge to ceiling should more than 67 mm. From installation plate left edge to unit’s left side is 74 mm. From installation plate right edge to unit’s right is 94 mm. : : :For left side piping, piping connection for liquid should be about 15 mm from this line. For left side piping, piping connection for gas should be about 45 mm from this line. For left side piping, piping connecting cable should be about 800 mm from this line. 1. Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the concrete wall consider using anchor bolts.) • Always mountthe installation plate horizontally by aligning the marking-off line with the thread and using a level gauge. 2. Drill the piping plate hole with ø70 mm hole-core drill. • Line according to the arrows marked on the lower left and right side of the installation plate. The meeting point of the extended line is the centre of the hole. Another method is by putting measuring tape at position as shown in the diagram above. The hole centre is obtained by measuring thedistance namely 150 mm and 125 mm for left and right hole respectively. • Drill the piping hole at either the right or the left and the hole should be slightly slanted to the outdoor side. 10.5.3. TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING 1. Insert the piping sleeve to the hole. 2. Fix the bushing to the sleeve. 3. Cut the sleeve until it extrudes about 15 mm from the wall. CautionWhen the wall ishollow, please be sure to use the sleeve for tubeass’y to prevent dangers caused by mice biting the connecting cable. 4. Finish by sealing the sleeve with putty or caulking compound at the final stage. 10.5.4. INDOOR UNIT INSTALLATION 1. For the right rear piping 2. For the right and right bottom piping 10.5. Indoor unit 48 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
3. For the embedded piping (This can be used for left rear piping & left bottom piping also.) 49 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /
10.5.5. CONNECT THE CABLE TO THE INDOOR UNIT 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 3 (C7DK, C9DK, C12DK) or 5 (A7DK, A9DK, A12DK) × 1.5 mm 2 flexible cord, typedesignation 245 IEC 57 or heavier cord. • Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively. • Earth lead wire shall be longer than the other lead wires as shown in the figure forthe electrical safetyin case of the slipping out of the cord from the anchorage. • Secure the cable onto the control board with the holder (clamper). INSTALLATION OFSUPER ALLERU-BUSTER FILTER 1. Open the front panel. 2. Remove the air filters. 3. Remove Supersonic air purifying device. 4. Open the Supersonic airpurifying device frame. 5. Insert the super alleru-buster filter and close the Supersonic air purifying device frame as shown in illustration at below. HOW TO TAKE OUT FRONT GRILLE Please follow the steps below to take out front grille if necessary such as when servicing. 1. Open the intake grille and remove the screw at the front of the front grille. 50 CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12D KD CU-A12D KD /